• Title/Summary/Keyword: early detection system

Search Result 609, Processing Time 0.035 seconds

A study on early faults detection of pressurizer pressure control system using MTS (MTS를 이용한 가압기 압력 제어 계통의 조기 고장 감지에 대한 연구)

  • Cha, Jae-Min;Kim, Joon-Young;Shin, Junguk;Yeom, Choongseob;Kang, Seong-Ki
    • The Korean Journal of Applied Statistics
    • /
    • v.29 no.7
    • /
    • pp.1385-1398
    • /
    • 2016
  • A pressurizer is a major equipment system in a nuclear power plant (NPP) and controls the reactor cooling system pressure within the allowable range. Faults in the pressurizer can be critical to the NPP; therefore, early fault detection in the pressurizer is significant for NPP safety. This study applies Mahalanobis Taguchi system (MTS), which is one of the promising pattern classification methods, based on the Mahalanobis distance concept and Taguchi quality engineering theory to the early fault detection problem of the pressurizer pressure control system. We conducted experiments using data from full scope NPP simulator based on a pressurizer pressure transmitter faults scenario to validate the faults detection performance of MTS. As a result, MTS can rapidly detect the faults compared to conventional faults detection based on single sensor monitoring.

BioMEMS-EARLY DISEASE DETECTION (BioMEMS 기반의 조기 질병 진단 기술에 관한 연구)

  • Singh, Kanika;Kim, Kyung-Chun
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2781-2784
    • /
    • 2007
  • Early detection of a disease is important to tackle treatment issues in a better manner. Several diagnostic techniques are in use, these days; for such purpose and tremendous research is going on to develop newer and newer methods. However, more work is required to be done to develop cheap and reliable early detection techniques. Micro-fluidic chips are also playing key role to deliver new devices for better health care. The present study focuses on a review of recent developments in the interrogation of different techniques and present state-of-the-art of microfluidic sensor for better, quick, easy, rapid, early, inexpensive and portable POCT (Point of Care testing device) device for a particular study, in this case, bone disease called osteoporosis. Some simulations of the microchip are also made to enable feasibility of the development of a blood-chip-based system. The proposed device will assist in early detection of diseases in an effective and successful manner.

  • PDF

Power Quality Early Warning Based on Anomaly Detection

  • Gu, Wei;Bai, Jingjing;Yuan, Xiaodong;Zhang, Shuai;Wang, Yuankai
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1171-1181
    • /
    • 2014
  • Different power quality (PQ) disturbance sources can have major impacts on the power supply grid. This study proposes, for the first time, an early warning approach to identifying PQ problems and providing early warning prompts based on the monitored data of PQ disturbance sources. To establish a steady-state power quality early warning index system, the characteristics of PQ disturbance sources are analyzed and summed up. The higher order statistics anomaly detection (HOSAD) algorithm, based on skewness and kurtosis, and hierarchical power quality early warning flow, were then used to mine limit-exceeding and abnormal data and analyze their severity. Cases studies show that the proposed approach is effective and feasible, and that it is possible to provide timely power quality early warnings for limit-exceeding and abnormal data.

Feasibility Study on the Landfill Monitoring and Leakage Detection System

  • Park, Jun-Boum;Kwon, Ki-Bum;Oh, Myoung-Hak;Mishra, Anil Kumar
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2007.09a
    • /
    • pp.558-569
    • /
    • 2007
  • It is important to obtain real-time data from long-term monitoring of landfills and develop leachate leakage detection system for the integrated management of landfills. A novel real time monitoring system and early leakage detection system was suggested in this study. The suggested monitoring system is composed of two parts; (1) a set of moisture sensors which monitor the areas surrounding the landfill, and (2) a set of moisture and temperature sensors which monitor the landfill inside. For the assessment for landfills stabilization, real-time monitoring system was evaluated in dry and wet cell of pilot-site. In addition, the grid-net electrical conductivity measurement system was also suggested as early leakage detection system. In this study, the field applicability of suggested systems was evaluated through pilot-scale field tests. The results of pilot-scale field model tests indicate that the grid-net electrical conductivity measurement method can be applicable to the detection of landfill leachate at the initial stage of intrusion, and thus has a potential for monitoring leachate leakage at waste landfills.

  • PDF

Development of a precision smoke particle detector to sense a fire in early state (초기화재 감지를 위한 정밀한 연기 입자 감지 장치 개발)

  • 김희식;김영재;이호재
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1734-1737
    • /
    • 1997
  • The conventional fire detection devices are operated after a processed fire phase, which are sensing only a high density of somke level or high temperature heat. They are not so precision to detect a fire in the early phase to protect the facility form the fire. We need to develope a new high precision smoke detection system to keep expensive industrial facilities most reliably form fire. A new optical precision smoke detection system was developed. It monitors very low level density of smoke particles in the air. It is operated continously through many years without a stop or any malfunction. The developed precision smoke detection system will be installed in important industrial facilities, such as power plants, underground common tunnel, main control rooms, computer rooms etc.

  • PDF

Methods for Early Fire Detection and Fire Position Determination Inside the Nacelle of Wind Turbine Generator System (풍력발전기 나셀 내부 화재 조기감지 및 화재 위치 판별 방법)

  • Kim, Da Hee;Lim, Jong Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.12
    • /
    • pp.935-943
    • /
    • 2015
  • This paper presents a method for early fire detection and fire position determination inside the nacelle of wind turbine generator system. The rising temperature and obscuration rates inside the nacelle were used as parameters for fire detection, which can minimize the possibility of a fire detection malfunction because these rising rates do not depend on the absolute values of temperature and obscuration. The fire position was determined using the time difference among various sensor positions for fire detection. The performance of the method was tasted using sets of experiments in a nacelle simulator.

Water Level Tracking System based on Morphology and Template Matching

  • Ansari, Israfil;Jeong, Yunju;Lee, Yeunghak;Shim, Jaechang
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.12
    • /
    • pp.1431-1438
    • /
    • 2018
  • In this paper, we proposed a river water level detection and tracking of the river or dams based on image processing system. In past, most of the water level detection system used various water sensors. Those water sensors works perfectly but have many drawbacks such as high cost and harsh weather. Water level monitoring system helps in forecasting early river disasters and maintenance of the water body area. However, the early river disaster warning system introduces many conflicting requirements. Surveillance camera based water level detection system depends on either the area of interest from the water body or on optical flow algorithm. This proposed system is focused on water scaling area of a river or dam to detect water level. After the detection of scale area from water body, the proposed algorithm will immediately focus on the digits available on that area. Using the numbers on the scale, water level of the river is predicted. This proposed system is successfully tested on different water bodies to detect the water level area and predicted the water level.

Extended Early-Late Phase Scheme using Combined Pseudo-Random Noise Signal to Detect GPS Repeat-Back Jamming Signals (GPS 재방송 재밍신호 검출을 위한 통합 의사잡음신호를 사용한 확장된 ELP 기법)

  • Yoo, Seungsoo;Yeom, Dong-Jin;Jee, Gyu-In;Kim, Sun Yong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.6
    • /
    • pp.483-489
    • /
    • 2016
  • This paper proposes a repeat-back jamming signal detection scheme that utilizes a combined pseudo random noise signal that is effective for processing a global positioning system (GPS) repeat-back jamming signal with the early minus late phase scheme to alleviate any existing multipath signal detection. The proposed scheme uses the combined pseudo random noise signal to treat repeat-back jamming signals like similar multipath signals and can effectively detect a repeat-back jamming signal by applying the early minus late phase scheme to a combined pseudo random noise signal. Through a Monte-Carlo simulation, the detection probability of the proposed scheme is better than the one of the conventional scheme under low jamming to signal power ratio.

A Study on the Satellite Launch Vehicle Separation Detection Interface to Improve the Reliability of the Launch and Early Operation Phase

  • Lee, Nayoung;Kwon, Dong-young;Jeon, Hyeon-Jin;Jeon, Moon-Jin;Cheon, Yee-Jin
    • Journal of Aerospace System Engineering
    • /
    • v.15 no.4
    • /
    • pp.57-63
    • /
    • 2021
  • The launch vehicle (LV) separation detection interface of the satellite, which is designed to initiate the launch and early operation phase (LEOP) for S-band data transmission and the solar array deployment after the LV separation, is one of the hazard items at the launch site. Therefore, this interface should satisfy the single-fault tolerance requirement for the range safety. In this paper, we discuss the LV separation detection interfaces for two different satellite launch configurations and propose a method to guarantee for the satellite to start the LEOP even under the emergency case such as a partial separation from the LV. Furthermore, the proposed method meets the range safety requirement of the launch site. As this method only changes the external harness configuration of the satellite, it increases the reliability of the satellite early operation without any modification of the existing internal logics to detect the separation event.

Prediction Principle and System Structure for the Detection of Incipient Electrical Fire (전기화재 예지원리 및 징후검출 시스템 구조)

  • 김창종
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.4
    • /
    • pp.71-77
    • /
    • 1995
  • Electrical fire in residential, commercial, and industrial areas occupies 40 percent of overall fire accidents as of the year of 1994. The causes of most electrical fires were studied and, based on this investigation, the principle of the early detection or prediction of the electrical fires is developed. The basic principle is to early detect electrical arcs or sparks caused by faulty connections and insulation failures. the structure of the prediction system based on microcontroller technique is presented.

  • PDF