• Title/Summary/Keyword: e-calipers

Search Result 8, Processing Time 0.022 seconds

An Implementation of Smart E-Calipers for Mobile Phones (모바일 폰을 이용한 스마트 E-캘리퍼스 구현)

  • Yun, Han-Kyung
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.5
    • /
    • pp.331-337
    • /
    • 2020
  • The study is underway with the goal of developing an app that will replace vernier calipers using a smartphone's high-performance camera. The specifications of the camera mounted on recent smart phones have evolved so that usually has a 12 Mpixels of image sensor and its size of the pixel is 1.4㎛ and the size of the image sensor is 1 / 2.55 in. The proposed algorithm will apply to develop a precision measuring application that will compete with the Vernier calipers. Most existing applications cannot guarantee an accuracy in scale because the scale of the ruler displayed on the image is unclear or the size of the measurement object varies depending on the distance between the camera and the measurement object. In addition, another accurate measuring tools using lasers are also available, but they are limited because they are expensive. Therefore, if easy-to-carry and precise applications are developed, it is possible to substitute existing measurement tools. The proposed correction algorithm is an algorithm that automatically corrects the distorted source image using the shape and size information of the known template. The e-calipers are applications that display the distance when the area to be measured is specified in the corrected image.

Development of the Vision System to Inspect the Inside of the Brake Calipers (브레이크 캘리퍼 내부 검사를 위한 비전시스템 개발)

  • Kwon, Gyoung Hoon;Chu, Hyung Gon;Kim, Jin Young;Kang, Joonhee
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.39-43
    • /
    • 2017
  • Development of vision system as a nondestructive evaluation system can be very useful in screening the defective mechanical parts before they are assembled into the final product. Since the tens of thousands of the mechanical parts are used in an automobile carefully inspecting the quality of the mechanical parts is very important to maximize the performance of the automobile. To sort out the defective mechanical parts before they are assembled, auto parts fabrication companies employ various inspection systems. Nondestructive evaluation systems are getting rapidly popular among various inspection systems. In this study, we have developed a vision system to inspect the inside of the brake caliper, a part that is used to compose a brake which is the most important to the safety of the drivers and the passengers. In a brake caliper, a piston is pushed against the brake disk by oil pressure, causing a friction to damp the rotation of the wheel. Inside the caliper, a groove is positioned to adopt an oil seal to prevent the oil leaks. Inspecting the groove with our vision system, we could examine the existence of the contaminants which are normally the residual tiny pieces from the machining process. We used a high resolution GigE camera, 360 degree lens to look in the inside view of the caliper at once, and a special illumination system in this vision system. We used the edge detection technique to successfully detect the contaminants which were in the form of small metal chips. Labview graphical program was used to process the digital data from the camera and to display the vision and the statistics of the contaminants. We were very successful in detecting the contaminants from the various size calipers. We think we are ready to employ this vision system to the caliper production factories.

Evaluating Accuracy according to the Evaluator and Equipment Using Electronic Apex Locators

  • Yu, Beom-Young;Son, Keunbada;Lee, Kyu-Bok
    • Journal of Korean Dental Science
    • /
    • v.13 no.2
    • /
    • pp.52-58
    • /
    • 2020
  • Purpose: Using two types of electronic apex locators, this study aimed to investigate the differences in accuracy according to the evaluator and equipment. Materials and Methods: Artificial teeth of the lower first premolars and two mandibular acrylic models (A and B) were used in this study. In the artificial teeth, the pulp chamber was opened and the access cavity was prepared. Using calibrated digital Vernier calipers, the distance from the top of the cavity and the root apex was measured to assess the actual distance between two artificial teeth. The evaluation was conducted by 20 dentists, and each evaluator repeated measurements for each electronic apex locator five times. The difference between the actual distance from the top of the cavity to the root apex and the distance measured using electronic measuring equipment was compared. For statistical analysis, the Friedman test the Mann-Whitney U-test were conducted and the differences between groups were analyzed (α=0.05). Result: As for the accuracy of measurement according to the two types of electronic apex locators, the value of the measurement error was 0.4753 mm in Dentaport ZX and 0.3321 mm in E-Cube Plus. Moreover, electronic apex locators Dentaport ZX and E-Cube Plus showed statistically significant differences (P<0.05). As for the difference in the accuracy of the two types of electronic apex locators according to the evaluator, the resulting values differed depending on the evaluator and showed a statistically significant difference (P<0.001). Conclusion: Electronic apex locator E-Cube Plus showed higher accuracy than did Dentaport ZX. Nevertheless, both types of electronic apex locators showed 100% accuracy in finding the region within root apex ±0.5 mm zone. Furthermore, according to the evaluator, the two electronic apex locators showed different resulting values.

Simultaneous Measurement of Ultrasonic Velocity and Thickness of Isotropic and Homogeneous Solids Using Two Transducers (두개의 탐촉자를 사용한 등방성 균일 고체의 초음파 속도 및 두께 동시 측정법)

  • Lee, Jeong-Ki;Kwon, Jin-O;Kim, Young-H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.5
    • /
    • pp.363-368
    • /
    • 1999
  • Ultrasonic pulse-echo methods measuring the transit time through specimens have been widely used in determination of ultrasonic velocity and thickness of specimens. Usually, to determine the velocity of the ultrasonic. the transit time of the ultrasonic pulse through specimen is measured by using the ultrasonic measuring equipment such as the oscilloscope including ultrasonic pulser/receiver and the thickness of the specimen is measured by using the length measuring instrument such as micrometer or vernier calipers etc., i. e. each parameter is measured by using each measuring method. In the case of the measuring the thickness of a specimen by using the ultrasonics. the ultrasonic equipments, which measure the thickness, such as the ultrasonic thickness gauge must be calibrated by using the reference block of which the ultrasonic velocity is known beforehand. In the present work, we proposed a new method for simultaneous measurement of ultrasonic velocity and thickness without reference blocks. Experimental results for several specimens show that proposed method have good agreements with those by traditional ultrasonic method.

  • PDF

Accuracy and reliability of measurements performed using two different software programs on digital models generated using laser and computed tomography plaster model scanners

  • Camardella, Leonardo T.;Ongkosuwito, Edwin M.;Penning, E. Willemijn;Kuijpers-Jagtman, Anne Marie;Vilella, Oswaldo V.;Breuning, K. Hero
    • The korean journal of orthodontics
    • /
    • v.50 no.1
    • /
    • pp.13-25
    • /
    • 2020
  • Objective: The aim of this study was to compare the accuracy and reliability of measurements performed using two different software programs on digital models generated using two types of plaster model scanners (a laser scanner and a computed tomography [CT] scanner). Methods: Thirty plaster models were scanned with a 3Shape laser scanner and with a Flash CT scanner. Two examiners performed measurements on plaster models by using digital calipers and on digital models by using Ortho Analyzer (3Shape) and Digimodel® (OrthoProof) software programs. Forty-two measurements, including tooth diameter, crown height, overjet, overbite, intercanine and intermolar distances, and sagittal relationship, were obtained. Results: Statistically significant differences were not found between the plaster and digital model measurements (ANOVA); however, some discrepancies were clinically relevant. Plaster and digital model measurements made using the two scanning methods showed high intraclass coefficient correlation values and acceptable 95% limits of agreement in the Bland-Altman analysis. The software used did not influence the accuracy of measurements. Conclusions: Digital models generated from plaster casts by using laser and CT scanning and measured using two different software programs are accurate, and the measurements are reliable. Therefore, both fabrication methods and software could be used interchangeably.

Associations Between Body Fat Percentage and Fitness among Police Officers: A Statewide Study

  • Violanti, John M.;Ma, Claudia C.;Fekedulegn, Desta;Andrew, Michael E.;Gu, Ja K.;Hartley, Tara A.;Charles, Luenda E.;Burchfiel, Cecil M.
    • Safety and Health at Work
    • /
    • v.8 no.1
    • /
    • pp.36-41
    • /
    • 2017
  • Background: Police work is generally sedentary although there may be situations that require physical endurance and strength, such as foot chases and arresting suspects. Factors such as excessive body fat can impede an officer's physical ability to deal with such occurrences. Our objective was to examine associations between officers' body fat percentage (BF%) and performance on a standardized fitness protocol. Methods: Data were obtained from fitness screening among 1,826 male and 115 female officers in a large US police agency. The screening consisted of a 2.4-km run, push-ups, sit-ups, and sit-and-reach test. Sex-specific body fat percentages were estimated from skinfold thickness measured using calipers. Linear regression models were used to examine unadjusted and adjusted mean scores of fitness tests across BF% tertiles. Results: The prevalence of overall fitness was 4.3 times greater in male officers and 3.6 times greater in female officers having the lowest BF% tertile compared with the highest tertile (30.3% vs 7.1% and 46.0% vs 12.8%, respectively). BF% was linearly and positively associated with the time of 2.4-km run (p < 0.001), and linearly and inversely associated with the number of push-ups (p < 0.001), sit-ups (p < 0.001), and the distance of sit-and-reach (p < 0.001) in men. Similar associations were observed in women with the exception of sit-and-reach (p = 0.122). Associations were independent of age, race/ethnicity, rank, and duty station. Conclusion: Overall, BF% was inversely associated with fitness levels in male and female officers. Future longitudinal studies should be initiated to explore the potentially causal relationship between BF% and fitness in law enforcement officers.

Measurement of Verticality and Joint Gaps of a Near-surface Disposal Facility Vault Through a Mock-up Test for Fill-up Stages (표층처분시설 처분고의 목업테스트를 통한 채움단계별 수직도 및 이음부 벌어짐 측정)

  • Choi, Dong-Ho;Ann, Ki-Yong;Choi, In-Yong;Lee, Hyuk-Jin
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.4
    • /
    • pp.537-544
    • /
    • 2021
  • In order to describe the fill-up stages of a near-surface disposal facility vault, a mock-up test is performed, and its behavior during the fil l -up stages is investigated. On an in-site concrete foundation with a l ength of 6600mm, a width of 6600mm and a thickness of 400mm, a reinforced concrete disposal vaul t is manufactured with 4 precast (PC) corner wal l s and 8 PC side wal l s. 36 wasted drums are pl aced on the 1st fl oor in 6 by 6, and then the empty space is fil l ed with grout fil l er. These processes are repeated up to the 5th floor, and the verticality and the joint gaps are measured for each fill-up stage. The verticality is measured using a level at 6 positions on each side wall (3 positions on the left and right sides, respectivel y), i.e. a total of 24 positions on the 4 side wal l s. The joint gaps are measured at 9 positions on each side wal l (3 positions on the left, center and right sides, respectively), I.e. a total 36 positions on the 4 side walls. To measure the joint gaps, crack tips are installed on the left and right sides of every joint gap, and vernier calipers are used. The measured verticality obtained through the mock-up test was found to be ±0.1° based on the initial stage (ST0), and the result of the joint gap was up to 0.38mm. This appears to have a negligible effect on the structure.

The Variation of Nutural Population of Pinus densiflora S. et Z. in Korea -Change of variance due to number of family as sample size to affirm the population and family variations- (소나무 천연집단(天然集團)의 변이(變異)에 관(關)한 연구(硏究)(IV) -집단간(集團間) 및 가계간분산(家系間分散) 추정(推定)에 영향하는 가계수(家系數)에 대하여-)

  • Yim, Kyong Bin;Kwon, Ki Won;Lee, Kyong Jae
    • Journal of Korean Society of Forest Science
    • /
    • v.35 no.1
    • /
    • pp.39-46
    • /
    • 1977
  • In the analysis of variance between population and between individual trees (families), the fluctuation of values of variances due to sample size, (number of family) was analysed by two different designs, i.e. 2-level nested design with equal sample size and randomized complete block design. The variables were seedling heights and root calipers of 1-0 and 1-1 seedlings of Pinus densiflora S. et Z. The details of three natural stands and their progeny characters were presented in previous reports. 1. In nested design analysis. increase of sample size resulted the decrease of F-values among families in general, however, the F-values among populations showen the increasing tendency. The smaller the sample size, the larger the F-values fluctuation was resulted in general. At the point of beyond sample size 10, however, the fluctuation become to be stabilized. The F-value fluctuation seemed to be more in the case of analysis with random sampling method than with sequentially accumulated sampling method. And also such a tendency was more obvious in smaller sample size than in large one. 2. In R.C.B.D. analysis, the sample size to affirm the family variation was smaller than that for population variations.

  • PDF