• Title/Summary/Keyword: dynamic unbalance

Search Result 188, Processing Time 0.023 seconds

A Study on the Vibration of 2-Stage Gear System Considering the Change of Gear Meshing Stiffness and Imbalance of Motor (기어 물림부의 스프링강성 변화와 구동기의 불균형을 고려한 2단 기어장치의 진동에 관한 연구)

  • 정태형;이정상;최정락
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.6
    • /
    • pp.8-14
    • /
    • 2001
  • We develop a method to analyze dynamic behavior off multi-stage gear train system. The example system consists of three shafts supported by ball bearings at the ends of them and two pairs of spur gear set. For exact analysis, the meshing tooth pair of gear set is modeled as spring and damper having time-dependent meshing stiffness and damping. The bearing is modeled as spring. The result of this analysis is compared to that of other model having mean mesh stiffness. The effect of the excitation force by the unbalance off rotor off motor is also analyzed. Finally, the change ova natural frequency of the whole system due to the change of an angle between three shafts is compared in each case, and from this analysis, the avoiding angle for design is advised.

  • PDF

Pareto Optimal Design of the Vehicle Body (차체의 팔렛토 최적 설계)

  • Kim, Byoung-Gon;Chung, Tae-Jin;Lee, Jeong-Ick
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.4
    • /
    • pp.67-74
    • /
    • 2008
  • The important dynamic specifications in the aluminum automobile body design are the vibrations and crashworthiness in the views of ride comforts and safety. Thus, considerable effort has been invested into improving the performance of mechanical structures comprised of the interactive multiple sub-structures. Most mechanical structures are complex and are essentially multi-criteria optimization problems with objective functions retained as constraints. Each weight factor can be defined according to the effects and priorities among objective functions, and a feasible Pareto-optimal solution exists for the criteria-defined constraints. In this paper, a multi-criteria design based on the Pareto-optimal sensitivity is applied to the vibration qualities and crushing characteristics of front structure in the automobile body design. The vibration qualities include the idle, wheel unbalance and road shake. The crushing characteristic of front structure is the axial maximum peak load.

Analysis of the Current-Fed DC-DC Converter with Energy-Storage Reactor Feeding the Input (전원에 에너지가 회생되는 전류형 DC-DC 콘버어터의 해석)

  • ;原田耕介
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.20 no.4
    • /
    • pp.41-46
    • /
    • 1983
  • The current-fed DC-DC converter has only one energy storage reactor in series with the input for any number of outputs and is insensitive to transformer volt-second unbalance. It is considered that these properties of the converter are considerable advantages over other maltiple-output circuits. The steady-state and dynamic characteristic and stability for the current-fed DC-DC con-verter are analyzed in detail. The analysis is carried out by the state-space averaging method for the operation with the duty ratio less than 50% and is confirmed by the experiment. From the evaluation of stability it is identified that the stability of this converter is excellent as compared with that of the conventional buck type converter.

  • PDF

Rotordynamic Design of the Micro Gas Turbine Supported by Air Foil Bearings (공기포일베어링에 지지된 마이크로가스터빈의 회전체동역학적 설계)

  • Kim, Young-Cheol;Han, Jung-Wan;Kim, Kyung-Woong;Kim, Soo-Yong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.662-667
    • /
    • 2003
  • This paper presents a performance analysis of the 1st generation bump foil journal bearings for the micro gas turbine TG75. Static performances such as load capacity and attitude angle are estimated by using soft elasto-hydrodynamic analysis technique, and dynamic performances such as stiffness and damping coefficients are estimated by perturbation method. Rotordynamic analysis for TG75 is performed by using the bearing analysis results. TG75 rotor has 2 horizontal and vertical directional natural modes due to the bearing stiffness characteristics. TG75 rotor will be stably operated between the 1st bending mode at 33000cpm and the 2nd bending mode at 85500cpm. Unbalance response analysis results satisfy the API vibration criteria.

  • PDF

Operation Analysis of UPQC(Unified Power Quality Conditioner) based on H-bridge Modules (H-브리지 모듈로 구성된 UPQC(Unified Power Quality Conditioner)의 동작 분석)

  • Lee Bum-Kyoo;Bae Byung-Yeol;Baek Seung-Tak;Han Byung-Moon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • This paper proposes a novel UPQC(unified power quality conditioner) based on H-bridge modules, isolated through single-phase multi-winding transformers. The dynamic performance of proposed system was analyzed by simulation with PSCAD/EMTDC, assuming that the UPQC is connected with the 22.9kV distribution line. The proposed system can be directly connected to the transmission line without series injection transformers. It has flexibility in expanding the operation voltage by increasing the number of H-bridge modules and can compensate reactive power, harmonics, voltage sag and swell, voltage unbalance. The proposing UPQC has the ultimate capability of improving power quality at the point of installation on power distribution systems.

Analysis of Operating Mode Characteristics of Dynamic UPS (다이나믹 UPS의 모드별 동작특성 분석)

  • Lee K.S.;Kim J.W.;Byeon W.Y.;Nho E.C.;Kim I.D.;Chun T.W.;Kim H.G.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1257-1259
    • /
    • 2004
  • This paper deals with the operation of a flywheel energy storage UPS. The operating principle of the UPS is analysed in each mode including charging, voltage compensation, discharging, and voltage unbalance compensation. The usefulness of the operation is proved through simulations.

  • PDF

A Study on the Dynamic Characteristics of a Shaft with Initial Deflection (초기변형을 갖고 있는 회전축의 동특성에 관한 연구)

  • Kim, Y.C.;Kim, B.K.;Kim, B.O.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.6
    • /
    • pp.80-87
    • /
    • 1998
  • In this study, the effects of residual shaft bow and flexible bearings of a single disk rotor are investigated. The stiffness coefficients of a shaft with initial deflection are different from those of a straight shaft. The stiffness coefficients are calculated using Castigliano theorem considering initial deflections. The stiffness coefficients, which are obtained in this study, are in good agreement with FEM results. The speed which causes zero amplitude is shown to be the square root of the ratio of residual bow amplitude to unbalance eccentricity in the case of rigid bearings and isotropic flexible bearings, but not in anisotropic bearings.

  • PDF

Rotordynamic Design and Analysis of the Rotor-Bearing System of a 600HP Gear Driven Turbo-Compressor (600HP급 기어구동형 터보 공기압축기 회전체계의 동역학적 설계 및 해석)

  • 최상규;김영철;권병수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.50-57
    • /
    • 1997
  • A 600HP class high-speed gear driven 3-stage turbo-compressor (IGCC : Integrally Geared Centrifugal Compressor) driven by a 3600 rpm AC induction motor has been designed, of which low speed pinion runs at 35000 rpm and high speed pinion at 50000 rpm nominally. Due to its high speed operation, the system requires very reliable bearing selection and design as well as accurate rotordynamic analysis and prediction of its dynamic behavior to secure the operating reliability. Rotordaynamic analyses of the IGCC rotor-bearing system predicted that the low speed pinion rotor mounted on 5-pad tilting pad bearings has two critical speeds before its design speed and high speed pinion rotor only one critical speed, and estimated critical speeds of both pinion shafts are away from the continuous operating speed enough to satisfy the corresponding API requirement. The forced response analysis with API specified maximum allowable unbalances also showed that unbalance responses are small enough for smooth operation of the system.

  • PDF

Vibration Analysis of Steam Turbine-Generator Rotor System Using Component Mode Synthesis Method (구분모드합성법을 이용한 증기터빈$\cdot$발전기축계의 진동해석)

  • Yang, B.S.;Kim, Y.H.;Choi, B.G.;Lee, H.
    • Journal of KSNVE
    • /
    • v.9 no.2
    • /
    • pp.401-408
    • /
    • 1999
  • A method is presented for the vibration analysis of steam turbine-generator rotor system based on the component mode synthesis method. The motion of each component of the system is described by superposing constraint mode associated with boundary coordinates and constrained normal modes associated with internal coordinates. This method using real fixed-interface modes allows for significant reduction in system model size while retaining the essential dynamic characteristics of the lower modes. The capability of this method is demonstrated in the natural frequency and unbalance response analysis of the steam turbine-generator rotor system in which the dynamics of the pedestal is considered. The results by the present method are compared with finite element method and trnasfer matrix method in terms of the accuracy and computing time.

  • PDF

Update Method based on Dynamic Access-Frequency Tree in Grid Database System (그리드 데이터베이스 환경에서 동적 접근 빈도를 이용한 갱신 기법)

  • Shin, Soong-Sun;Back, Sung-Ha;Lee, Yeon;Lee, Dong-Wook;Kim, Gyoung-Bae;Chung, Worn-Il;Bae, Hae-Young
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.9
    • /
    • pp.1191-1200
    • /
    • 2009
  • The replicas in the Grid database is utilized for a lot of application services. And for deferent services or for deferent information depends on location, the access frequency of each replica is dissimilar. When one replica is stored in many nodes, each replicas applies the week-consistency in the grid computing environment. Especially, when a node work load or operation capacity is varied from others, the replica management would cost expansive. Therefore, this paper proposed the Update Method based on Dynamic Access-Frequency Tree. The dynamic access-frequency tree is pre-constructed by grouping nodes based on each nodes access frequency to manage the replica efficiently and avoid unbalance replica tree. The performance evaluation shows the proposed methods support more quick update than current methods.

  • PDF