• 제목/요약/키워드: dynamic mechanical thermal analysis

검색결과 220건 처리시간 0.026초

에폭시 아크릴레이트의 전자선 영향 평가 (Characterization of Electron Beam Cured Epoxy Acrylate)

  • 신진욱;오병환;고금진;전준표;강필현
    • 방사선산업학회지
    • /
    • 제4권3호
    • /
    • pp.271-276
    • /
    • 2010
  • Epoxy resin has wide application in various industrial fields because of their good mechanical strength, superiority adhesion and low shrinkage etc. And the typical curing method for epoxy resins is thermal and press compaction. However, a curing method was used electron beam process in this study. Epoxy acrylate was fabricated from mixture of epoxy, acrylic acid, tetraphenylporphyrin (TPP) and hydroquinone monomethyl ether (MEHQ) with mole ratios. Then electron beam irradiation effect on the curing of the epoxy acrylate resin was investigated various absorption dose in nitrogen atmospheres at room temperature. The dynamic mechanical and thermal properties of the irradiated epoxy acrylate resins were characterized using dynamic mechanical analysis (DMA) and thermogravimetric analyzer (TGA). And the tensile and flexural strength were measured by an universal tensile machine (UTM).

부하 대응 제어방식을 적용한 축열식 히트펌프시스템의 성능 해석 (A Performance Analysis on a Heat pump with Thermal Storage Adopting Load Response Control Method)

  • 김동준;강병하;장영수
    • 설비공학논문집
    • /
    • 제30권3호
    • /
    • pp.130-142
    • /
    • 2018
  • We use heat pumps with thermal storage system to reduce peak usage of electric power during winters and summers. A heat pump stores thermal energy in a thermal storage tank during the night, to meet load requirements during the day. This system stabilizes the supply and demand of electric power; moreover by utilizing the inexpensive midnight electric power, thus making it cost effective. In this study, we propose a system wherein the thermal storage tank and heat pump are modeled using the TRNSYS, whereas the control simulations are performed by (i) conventional control methods (i.e., thermal storage priority method and heat pump priority method); (ii) region control method, which operates at the optimal part load ratio of the heat pump; (iii) load response control method, which minimizes operating cost responding to load; and (iv) dynamic programming method, which runs the system by following the minimum cost path. We observed that the electricity cost using the region control method, load response control approach, and dynamic programing method was lower compared to using conventional control techniques. According to the annual simulation results, the electricity cost utilizing the load response control method is 43% and 4.4% lower than those obtained by the conventional techniques. We can note that the result related to the power cost was similar to that obtained by the dynamic programming method based on the load prediction. We can, therefore, conclude that the load response control method turned out to be more advantageous when compared to the conventional techniques regarding power consumption and electricity costs.

Analysis on Ampacity of Overhead Transmission Lines Being Operated

  • Yan, Zhijie;Wang, Yanling;Liang, Likai
    • Journal of Information Processing Systems
    • /
    • 제13권5호
    • /
    • pp.1358-1371
    • /
    • 2017
  • Dynamic thermal rating (DTR) system is an effective method to improve the capacity of existing overhead line. According to the methodology based on CIGRE (International Council on Large Electric systems) standard, ampacity values under steady-state heating balance can be calculated from ambient environmental conditions. In this study, simulation analysis of relations between parameters and ampacity is described as functional dependence, which can provide an effective basis for the design and research of overhead transmission lines. The simulation of ampacity variation in different rating scales is described in this paper, which are determined from real-time meteorological data and conductor state parameters. To test the performance of DTR in different rating scales, capacity improvement and risk level are presented. And the experimental results show that the capacity of transmission line by using DTR has significant improvement, with low probability of risk. The information of this study has an important reference value to the operation management of power grid.

Mercaptan 경화제에 의한 저온속경화 에폭시의 열적 기계적 물성 (Mechanical Properties of Low Temperature and Fast Cure Epoxy with Various Mercaptans)

  • 김원영;엄세연;서상범;이기윤
    • 폴리머
    • /
    • 제37권5호
    • /
    • pp.557-562
    • /
    • 2013
  • 본 연구에서는 DGEBA(diglycidyl ether of bisphenol A)와 mercaptan 경화제계의 경화 후 열에 의한 팽창 특성과 역학 거동을 에폭시/아민 유도체형 경화제계와 비교하여 연구하였다. 열팽창계수와 역학거동은 각각 TMA(thermo mechanical analysis)와 역학 거동은 DMA(dynamic mechanical ananlysis)를 이용하여 분석하였다. 아민 유도체형 경화제를 사용한 에폭시 경화물의 유리전이온도와 열팽창계수는 각각 $82.6^{\circ}C$와 71.2 $ppm/^{\circ}C$의 값을 나타냈다. Mercaptan 경화제를 사용한 에폭시 경화물의 경우 -SH 관능기가 증가할수록 유리전이온도는 급격히 감소하였다가 점차 증가하여 약 $80^{\circ}C$ 이상의 값을 갖는 경향을 보였고, 유리전이온도 이하에서 열팽창률은 약 80 $ppm/^{\circ}C$에서 최대 200 $ppm/^{\circ}C$까지 증가하였다가 약 100 $ppm/^{\circ}C$로 다시 감소하는 경향을 보였다. 아민 유도체형 경화제를 사용한 에폭시 경화물은 약 1.5 $mol/cm^3$의 가교밀도를 나타냈고, mercaptan 경화제를 사용한 에폭시 경화물은 약 1.0 $mol/cm^3$에서 약 1.7 $mol/cm^3$로 관능기가 증가할수록 가교밀도가 증가했다. 또한 $30^{\circ}C$에서 2700 MPa 이상의 저장 탄성률을 가질 수 있음을 확인하였다.

화학-기계적 연마 공정의 물질제거 메커니즘 해석 Part II: 동적 시뮬레이션 (An Analysis on the Material Removal Mechanism of Chemical-Mechanical Polishing Process Part II: Dynamic Simulation)

  • 석종원;오승희
    • 반도체디스플레이기술학회지
    • /
    • 제6권3호
    • /
    • pp.1-6
    • /
    • 2007
  • The integrated thermal-chemical-mechanical (TCM) material removal model presented in the companion paper is dynamically simulated in this work. The model is applied to a Cu CMP process for the simulation and the results of the three individual ingredients composing the model are presented separately first. These results are then incorporated to calculate the total material removal rate (MRR) of the Cu CMP. It is shown that the non-linear trend of MRR with respect to the applied mechanical power (i.e., non-Prestonian behavior), which is not well explained with the models established in principle on conventional contact mechanics, may be due to the chemical reaction(s) varying non-linearly with the temperature in the wafer.

  • PDF

Thermal and Mechanical Properties of Epoxy/Micro- and Nano- Mixed Silica Composites for Insulation Materials of Heavy Electric Equipment

  • Park, Jae-Jun;Yoon, Ki-Geun;Lee, Jae-Young
    • Transactions on Electrical and Electronic Materials
    • /
    • 제12권3호
    • /
    • pp.98-101
    • /
    • 2011
  • A 10 nm nano-silica was introduced to a conventional 3 ${\mu}M$ micro-silica composite to develop an eco-friendly new electric insulation material for heavy electric equipment. Thermal and mechanical properties, such as glass transition temperature (Tg), dynamic mechanical analysis, tensile and flexural strength, were studied. The mechanical results were estimated by comparing scale and shape parameters in Weibull statistical analysis. The thermal and mechanical properties of conventional epoxy/micro-silica composite were improved by the addition of nano-silica. This was due to the increment of the compaction via the even dispersion of the nano-silica among the micro-silica particles.

Blends of Silicone Rubber and Liquid Crystalline Polymer

  • Shivakumar E.;Das C. K.;Pandey K. N.;Alam S.;N.Mathur G.
    • Macromolecular Research
    • /
    • 제13권2호
    • /
    • pp.81-87
    • /
    • 2005
  • Blends of silicone rubber (VMQ) and liquid crystalline polymer (LCP) were prepared by the melt mixing technique. Mechanical, XRD, thermal and dynamic mechanical investigations are reported for the pure silicone rubber and blends. The mechanical properties, viz. the tensile strength, tear strength and elongation at break, of the silicone rubber decreased with the addition of LCP. The SEM study on the tensile fractured surface of the blends revealed that they had a two phase structure, and that the failure was mainly due to fiber pull out, which suggests that the VMQ and LCP are incompatible in all of the proportions examined in this study. However, the FTIR study shows that there was a partial interaction between the VMQ and LCP, but which may not be sufficient to grip the fibrils under the applied load. In the XRD analysis, it was observed that the crystalline structure of the silicone rubber deteriorated in the presence of LCP. The DMA study suggested that the storage modulus of the silicone rubber was improved with the addition of LCP, due to the high modulus of the LCP phase. The thermal stability of the silicone rubber was greatly reduced by the addition of LCP, due to the latter having a thermal stability lower than that of silicone rubber.

120kW급 IGBT 인버터의 열 응답 특성 실시간 모델 (A Real Time Model of Dynamic Thermal Response for 120kW IGBT Inverter)

  • 임석연;차강일;유상석
    • 한국수소및신에너지학회논문집
    • /
    • 제26권2호
    • /
    • pp.184-191
    • /
    • 2015
  • As the power electronics system increases the frequency, the power loss and thermal management are paid more attention. This research presents a real time model of dissipation power with junction temperature response for 120kw IGBT inverter which is applied to the thermal management of high power IGBT inverter. Since the computational time is critical for real time simulation, look-up tables of IGBT module characteristic curve are implemented. The power loss from IGBT provides a clue to calculate the temperature of each module of IGBT. In this study, temperature of each layer in IGBT is predicted by lumped capacitance analysis of layers with convective heat transfer. The power loss and temperature of layers in IGBT is then communicated due to mutual dependence. In the dynamic model, PWM pulses are employed to calculation real time IGBT and diode power loss. Under Matlab/Simulink$^{(R)}$ environment, the dynamic model is validated with experiment. Results showed that the dynamic response of power loss is closely coupled with effective thermal management. The convective heat transfer is enough to achieve proper thermal management under guideline temperature.

노즐 형상변화에 따른 HVOF 용사총에서의 유동특성에 관한 수치적 연구 (A Numerical Study on Flow Characteristics in HVOF Thermal Spray with Various Torch Shapes)

  • 백재상;김윤제
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3062-3067
    • /
    • 2007
  • HVOF thermal spray guns are now being widely used to produce protective coatings, on the surfaces of engineering components. HVOF technology employs a combustion process to heat the gas flow and melt the coating materials which are particles of metals, alloys or cermets. Particle flow which is accelerated to high velocities and combustion gas stream are deposited on a substrate. In order to obtain good quality coatings, the analysis of torch design must be performed. The reason is that the design parameters of torch influence gas dynamic behaviors. In this study, numerical analysis is performed to predict the gas dynamic behaviors in a HVOF thermal spray gun with various torch shapes. The CFD model is used to deduce the effect of changes in nozzle geometry on gas dynamics. Using a commercial code, FLUENT which uses Finite Volume Method and SIMPLE algorithm, governing equations have been solved for the pressure, velocity and temperature distributions in the HVOF thermal spray torch.

  • PDF

고속전철용 디스크-패드 브레이크의 동적거동 특성에 관한 유한요소해석 (Finite Element Analysis on the Dynamic Behaviors of a Disk-Pad Brake in High-Speed Trains)

  • 김청균;조승현
    • Tribology and Lubricants
    • /
    • 제16권2호
    • /
    • pp.7-7
    • /
    • 2000
  • Using a coupled thermal-mechanical analysis, the dynamic distortion of the ventilated disk brakes has been presented for a high-speed train. The offset ratio between the maximum and minimum values of the thermal distortions has been analyzed as a function of a braking number. The computed FEM results show that the offset rations in radial direction are much greater than those of circumferentially distorted components. This means that the axial distortions in radial direction may dominantly produce thermally caused wears and cracks at the rubbing surfaces.