• 제목/요약/키워드: dynamic lab-test

검색결과 99건 처리시간 0.025초

진동시험에 기초한 액상화 상세예측법 개발 (A New Assessment of Liquefaction Potential Based on the Dynamic Test)

  • 김수일;최재순;강한수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.245-252
    • /
    • 2004
  • When some enormous earthquake hazards broke out in the neighboring Japan and Taiwan, many Korean earthquake engineers thought that seismic guidelines must be adjusted safely and economically to consider the moderate earthquake characteristics. In the present aseismic guideline for liquefaction potential assessment, a simplified method using SPT-N value and a detail method based on the dynamic lab-tests were introduced. However, it is said that these methods based on the equivalent stress concept to simplify an irregular earthquake are not reliable to simulate the kaleidoscopical characteristics of earthquake loading correctly. Especially, even though various data from the dynamic lab-test can be obtained, only two data, a maximum cyclic load and a number of cycle at an initial liquefaction are used to determine the soil resistance strength in the detailed method. In this study, a new assessment of liquefaction potential is proposed and verified. In the proposed assessment, various data from dynamic lab-tests are used to determine the unique soil resistance characteristic and a site specific analysis is introduced to analyze the irregular earthquake time history itself. Also, it is found that the proposed assessment is reasonable because it is devised to reflect the changeable soil behavior under dynamic loadings resulted from the generation and development of excess pore water pressure.

  • PDF

Flexural behavior of precast concrete wall - steel shoe composite assemblies with dry connection

  • Wu, Xiangguo;Xia, Xinlei;Kang, Thomas H.K.;Han, Jingcheng;Kim, Chang-Soo
    • Steel and Composite Structures
    • /
    • 제29권4호
    • /
    • pp.545-555
    • /
    • 2018
  • This study aimed to investigate the flexural behavior of precast concrete (PC) wall - steel shoe composite assemblies with various dry connection details at mid-span. Flexural tests were performed for five scenarios. Test parameters included the width of test specimens, arrangement of steel shoe connectors, and use of structural adhesive or waterproof tape at the mid-span joint. The test results showed that the PC wall - steel shoe composite assemblies joined at mid-span showed flexural damage patterns combined with rotational deformation, and the structural performance was satisfactory regardless of the arrangement of steel shoe connectors. Considering the two deformation components (flexural deformation by bending and rotational deformation due to joint opening), a theoretical model was proposed to analyze flexural strength and joint opening, and the simple model gave good predictions with acceptable accuracy.

Interface monitoring of steel-concrete-steel sandwich structures using piezoelectric transducers

  • Yan, Jiachuan;Zhou, Wensong;Zhang, Xin;Lin, Youzhu
    • Nuclear Engineering and Technology
    • /
    • 제51권4호
    • /
    • pp.1132-1141
    • /
    • 2019
  • Steel-concrete-steel (SCS) sandwich structures have important advantages over conventional concrete structures, however, bond-slip between the steel plate and concrete may lead to a loss of composite action, resulting in a reduction of stiffness and fatigue life of SCS sandwich structures. Due to the inaccessibility and invisibility of the interface, the interfacial performance monitoring and debonding detection using traditional measurement methods, such as relative displacement between the steel plate and core concrete, have proved challenging. In this work, two methods using piezoelectric transducers are proposed to detect the bond-slip between steel plate and core concrete during the test of the beam. The first one is acoustic emission (AE) method, which can detect the dynamic process of bond-slip. AE signals can be detected when initial micro cracks form and indicate the damage severity, types and locations. The second is electromechanical impedance (EMI) method, which can be used to evaluate the damage due to bond-slip through comparing with the reference data in static state, even if the bond-slip is invisible and suspends. In this work, the experiment is implemented to demonstrate the bond-slip monitoring using above methods. Experimental results and further analysis show the validity and unique advantage of the proposed methods.

Evaluation on bridge dynamic properties and VIV performance based on wind tunnel test and field measurement

  • Yang, Yongxin;Ma, Tingting;Ge, Yaojun
    • Wind and Structures
    • /
    • 제20권6호
    • /
    • pp.719-737
    • /
    • 2015
  • Full scale measurement on the structural dynamic characteristics and Vortex-induced Vibrations (VIV) of a long-span suspension bridge with a central span of 1650 m were conducted. Different Finite Element (FE) modeling principles for the separated twin-box girder were compared and evaluated with the field vibration test results, and the double-spine model was determined to be the best simulation model, but certain modification still needs to be made which will affect the basic modeling parameters and the dynamic response prediction values of corresponding wind tunnel tests. Based on the FE modal analysis results, small-scaled and large-scaled sectional model tests were both carried out to investigate the VIV responses, and probable Reynolds Number effects or scale effect on VIV responses were presented. Based on the observed VIV modes in the field measurement, the VIV results obtained from sectional model tests were converted into those of the three-dimensional (3D) full-scale bridge and subsequently compared with field measurement results. It is indicated that the large-scaled sectional model test can probably provide a reasonable and effective prediction on VIV response.

실험에 의한 방진고무의 동특성에 관한 연구 (An Experimental Study on the Dynamic Characteristics of Rubber Isolator)

  • 김완두;김기세;권재도;우창수
    • Elastomers and Composites
    • /
    • 제37권3호
    • /
    • pp.183-191
    • /
    • 2002
  • 우수한 신장성과 탄성복원 능력으로 여러 산업분야에 방진, 제진, 충격흡수 및 완충재료로 널리 사용되고 있는 고무재료에 대하여 주파수, 변형률 진폭 및 온도변화가 동특성에 미치는 영향을 실험을 통하여 검토하였다. 동특성 시험은 5종류의 경도에 대하여 인장.압축시험과 전단시험용의 천연고무 시험 편으로 비 공진법으로 수행하였다. 시험결과, 경도가 높을수록 동적 특성 값들이 크게 나타났으며 저장탄성계수와 손실계수는 주파수가 증가할수록 서서히 증가하였으며 변형률 진폭이 커질수록 감소하였다. 또한, 온도 특성을 $-50^{\circ}C$ 영역에서 저장탄성계수가 급격히 상승하며 손실계수가 최대로 나타나는 전이역임을 알 수 있었다.

Toughnening of Dielectric Material by Thermoplastic Polymer

  • Lee, Jung-Woo;Cho, Jae-Choon;Ra, Seung-Hyun
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.207-208
    • /
    • 2007
  • Recently, high performance microelectronic devices are designed in multi-layer structure in order to make dense wiring of metal conductors in compact size. Imprint lithography have received significant attention due to an alternative technology for photolithography on such devices. In this work, we synthesized dielectric composite materials based on epoxy resin, and investigated their thermal stabilities and dynamic mechanical properties for thermal imprint lithography. In order to enhance the mechanical properties and toughness of dielectric material, various modified polyetherimide(PEI) was applied in the resin system. Curing behaviours, thermal stabilities, and dynamic mechanical properties of the dielectric materials cured with various conditions were studied using dynamic differential scanning calorimetry (DSC), thermo gravimetric analysis (TGA), and Universal Test Method (INSTRON).

  • PDF

Pretest analysis of a prestressed concrete containment 1:3.2 scale model under thermal-pressure coupling conditions

  • Qingyu Yang;Jiachuan Yan;Feng Fan
    • Nuclear Engineering and Technology
    • /
    • 제55권6호
    • /
    • pp.2069-2087
    • /
    • 2023
  • In nuclear power plant (NPP) accidents, the containment is subject to high temperatures and high internal pressures, which may further trigger serious chain accidents such as core meltdown and hydrogen explosion, resulting in a significantly higher accident level. Therefore, studying the mechanical performance of a containment under high temperature and high internal pressure is relevant to the safety of NPPs. Based on similarity principles, the 1:3.2 scale model of a prestressed concrete containment vessel (PCCV) of a NPP was designed. The loading method, which considers the thermal-pressure coupling conditions, was used. The mechanical response of the PCCV was investigated with a simultaneous increase in internal pressure and temperature, and the failure mechanism of the PCCV under thermal-pressure coupling conditions was revealed.

Property improvement of natural fiber-reinforced green composites by water treatment

  • Cho, Dong-Hwan;Seo, Jeong-Min;Lee, Hyun-Seok;Cho, Chae-Wook;Han, Seong-Ok;Park, Won-Ho
    • Advanced Composite Materials
    • /
    • 제16권4호
    • /
    • pp.299-314
    • /
    • 2007
  • In the present study, natural fibers (jute, kenaf and henequen) reinforced thermoplastic (poly(lactic acid) and polypropylene) and thermosetting (unsaturated polyester) matrix composites were well fabricated by a compression molding technique using all chopped natural fibers of about 10 mm long, respectively. Prior to green composite fabrication, natural fiber bundles were surface-treated with tap water by static soaking and dynamic ultrasonication methods, respectively. The interfacial shear strength, flexural properties, and dynamic mechanical properties of each green composite system were investigated by means of single fiber microbonding test, 3-point flexural test, and dynamic mechanical analysis, respectively. The result indicated that the properties of the polymeric resins were significantly improved by incorporating the natural fibers into the resin matrix and also the properties of untreated green composites were further improved by the water treatment done to the natural fibers used. Also, the property improvement of natural fiber-reinforced green composites strongly depended on the treatment method. The interfacial and mechanical results agreed with each other.

아스팔트 긴급보수용 스프레이 패칭 장비 개발 및 현장 적용성 평가 (Development of a Spray-Injection Patching System and a Field Performance Evaluation of 100% RAP Asphalt Mixtures using a Rapid-Setting Polymer-Modified Asphalt Emulsion)

  • 한수현;이상염;이석근;권봉주
    • 한국도로학회논문집
    • /
    • 제20권1호
    • /
    • pp.77-85
    • /
    • 2018
  • PURPOSES : The purpose of this study was to develop an urgent road-repair system and perform a field applicability test, as well as discover the optimum mix design for machine applications compared to the optimum mix design for lab applications. METHODS : According to reviews of the patent and developed equipment, self-propelled and mix-in-place equipment types are suitable for urgent pavement repair, e.g., potholes and cracks. The machine-application mix design was revised based on the optimum lab-test mix design, and the field application of a spray-injection system was performed on the job site. The mixture from the machine application and lab application was subjected to a wet-track abrasion test and a wheel-tracking test to calibrate the machine application. RESULTS and CONCLUSIONS : This study showed that the binder content could differ for the lab application and the machine application in the same setting. Based on the wet-track abrasion test result, the binder contents of the machine application exceeded the binder contents of the lab application by 1-1.5% on the same setting value. Moreover, the maximum dynamic stability value for the machine application showed 1% lower binder contents than the maximum lab-application value. Collectively, the results of the two different tests showed that the different sizes and operating methods of the machine and lab applications could affect the mix designs. Further studies will be performed to verify the bonding strength and monitor the field application.

에틸렌-프로필렌-디엔 삼원 공중합 (EPDM) 발포체의 충격음 저감 특성에 관한 연구 (A Study on Impact Sound Insulation Properties of EPDM Micro Cellular Pad)

  • 이경원;이정희;손호성
    • Elastomers and Composites
    • /
    • 제35권2호
    • /
    • pp.138-148
    • /
    • 2000
  • EPDM 발포체의 정적/동적 특성을 측정하여 재료 특성과 진동 특성과의 연관성을 알아보고 이로부터 충격음 저감재로서의 적용 가능성을 검토하였다. 정적/동적 특성은 material test system (MTS)를 사용하여 시편의 형상, 두께, 초기하중, 발포도 등에 따라 정적 탄성계수, 동적 탄성계수, 전달율의 변화를 조사하였다. 정적 탄성계수와 동적 탄성계수의 경우, 형상이 단순하고 두께가 얇을수록 큰 값을 나타냈고, 전달율과 동적 탄성계수는 상호 비례 관계에 있음을 확인할 수 있었다. 특징적으로 동적 탄성계수가 증가하면, 전달율의 특성 피크치는 같은 주파수 영역에서의 증가 혹은 고주파수 영역으로의 전이의 형태로 일어나게 되는 것을 알 수 있었다. 실험실적 모사 시험장치를 통해 충격에 따른 주파수별 진동 속도측정과 유한 요소 해석 모델을 사용하여 mode shape에 의한 충격 해석 결과를 알아보았는데, EPDM 발포체를 사용함으로써 2.5-3.5배의 진동 속도 저감이 이루어짐을 알 수 있었고, mode shape의 경우 몰타르와 콘크리트만으로 구성된 구조물에 비해 진동 충격에 대한 변위가 급감함으로써 충격음 저감재로서의 EPDM 발포체의 적용 가능성은 상당히 높은 것을 확인할 수 있었다.

  • PDF