• Title/Summary/Keyword: dynamic interval

Search Result 335, Processing Time 0.027 seconds

Spectra of Road Surface Roughness on Bridges of Minor Road (지방도 도로교 노면조도의 스펙트럼)

  • Chung, Tae Ju;Cha, Bong Ki
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.757-767
    • /
    • 2016
  • The power spectral density (PSD) for the road surface roughness on the bridges of minor roads in Wonju city and Hoengseong-gun, Gangwon-do is presented. To obtain the PSD, the road surface roughness on 18 different bridges with various superstructure type and span is measured by GPS at every 10 to 30cm interval. Assuming the PSD as the stationary normal probability process with zero mean value, the PSD of measured road surface roughness is obtained by applying the Maximum Entropy Method (MEM). A simple formula in evaluating the PSD of RC slab bridge, Rahmen bridge and PSC I-girder bridge which is applicable to the dynamic response analysis of bridges considering the road surface roughness is proposed. Using the calculated PSD curves, the road surface conditions on the 18 bridges are evaluated. The statistical relationship between the PSD and the IRI is presented by applying linear regression and correlation analysis.

Resonance Fiber Bragg Grating Sensor system based on Fourier Domain Mode-locking Laser (분광 영역 모드록킹 레이저를 이용한 공진형 광섬유 격자 센서)

  • Choi, Byeong Kwon;Jeon, Min Yong
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.5
    • /
    • pp.211-216
    • /
    • 2012
  • We report a resonance fiber Bragg sensor interrogation based on a Fourier domain mode-locking (FDML) laser. The FDML laser is constructed based on a conventional ring laser cavity configuration with fiber Fabry-Perot tunable filter (FFP-TF). There are two sensor parts which are composed with two FBGs inside the laser cavity. Each sensor part provides a separate laser cavity for the FDML laser. The resonance frequencies of the laser cavities are 46.687 kHz and 44.340 kHz, respectively. We applied a static and a dynamic strain on the FBG sensor system. The slope coefficients of the measured relative wavelength shift and relative time interval from the static strain are found to be $0.61pm/{\mu}{\epsilon}$ and $0.8ns/{\mu}{\epsilon}$, respectively.

Research about Hyperspectral Imaging System for Pre-Clinical testing of Small Animal (소형동물 전임상실험을 위한 하이퍼스펙트럼 영상장비 연구)

  • Lee, kyeong-Hee;Choi, Young-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2208-2213
    • /
    • 2007
  • In this study we have developed a hyperspectrum imaging system for highly sensitive and effective imaging analysis. An optical setup was designed using acoustic optical tunable filter (AOTF) for high sensitive hyperspectrum imaging. Light emitted by mercury lamp gets split in to diffracted and undiffracted beams while passing though AOTF. GFP transfected HEK-293 cell line was used as a model for in vitro imaging analysis. Cells were first, analyzed by fluorescence microscope followed by flow cytometric analysis. Flow cytometric analysis showed 66.31% transfection yield in GFP transfected HEK-293 cells. Various images of GFP transfected HEK-293 cell were grabbed by collecting the diffracted light using a CCD over a dynamic range of frequency of 129-171 MHz with an interval of 3 MHz. Subsequently, for in vivo image analysis of GFP transfected cells in mouse, a whole-body-imaging system was constructed. The blue light of 488 nm wavelength was obtained from a Xenon arc lamp using an appropriate filter and transmitted through an optical cable to a ring illuminator. To check the efficacy of the newly developed whole-body-imaging system, a comparative imaging analysis was performed on a normal mouse in presence and absence of Xenon arc irradiation. The developed hyperspectrum imaging analysis with AOTF showed the highest intensity of green fluorescent protein at 153 MHz of frequency and 494 nm of wavelength. However, the fluorescence intensity remained same as that of the background below 138 MHz (475 nm) and above 162 MHz (532 nm). The mouse images captured using the constructed whole-body-imaging system appeared monochromatic in absence of Xenon arc irradiation and blue when irradiated with Xenon arc lamp. Nevertheless, in either case mouse images appeared clearly.

Optimization of Radiation Protection Using Markov Model (마코프 모델을 이용한 방사선 방어의 최적화)

  • Chung, Jin-Yop;Lee, Kun-Jai
    • Journal of Radiation Protection and Research
    • /
    • v.14 no.2
    • /
    • pp.1-9
    • /
    • 1989
  • An analytic method for quantitative comparisions between the alternatives for radiation protection optimization is required to aid the decision making process. This paper introduces the dynamic Markov model to evaluate the effect of inservice inspection, testing, and repair activities of the plant on radiation protection. In the example to put the Markov model into practice, the steam generator inspection intervals which minimize expected cost and total exposure dose were determined using the data for Kori-2 unit and foreign plants. The results show that the effect of the radiation exposure on the steam generator inspection interval is determined by the cost rather than the radiation exposure. The Markov model used in the example can be applied easily to the domestic NPPs by replenishing the data and also can be used in evaluating the comparative priority between various alternatives for radiation protection optimization.

  • PDF

Effect of Peripheral Administration of Kisspeptin-10 on Dynamic LH Secretion in Prepubertal Ewes

  • Wang, Jun;Sun, Lei;Zhang, Tao;Zhou, Haizhu;Lou, Yujie
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.25 no.6
    • /
    • pp.785-788
    • /
    • 2012
  • The aim of the present study was to clarify the effect of kisspeptin-10 on LH secretion in prepubertal ewes. In experiment 1, prepubertal ewes fitted with indwelling jugular catheters were randomly assigned to receive 0, 0.5, 1 or 2 mg of kisspeptin-10 dissolved in saline, and serial blood samples were collected at 15-min intervals for 180 min to analyze the response curves of LH after injection. In experiment 2, prepubertal ewes fitted with indwelling jugular catheters were injected with 0 or 1 mg of kisspeptin-10 dissolved in saline and the injection was repeated 3 times at 1 h interval and serial blood samples were collected at 15-min intervals for 210 min to analyze the response curves of LH after injection. The results showed that single intravenous administration of 0.5, 1 and 2 mg of kisspeptin-10 all could significantly increased LH secretion in prepubertal ewes, and the effect of 1 and 2 mg of kisspeptin-10 on LH secretion was higher than that of 0.5 mg group. The results also showed that repeated intravenous administration of kisspeptin-10 could effectively increase LH secretion and repeated administration did not influence the effect of kisspeptin-10 on LH secretion in prepubertal ewe. In conclusion, the present study indicated that single or repeated intravenous administration of kisspeptin-10 could effectively increase LH secretion in prepubertal ewes.

Lateral Control of High Speed Flight Based on Type-2 Fuzzy Logic (Type-2 Fuzzy logic에 기반 한 고속 항공기의 횡 운동 제어)

  • Song, Jin-Hwan;Jeon, Hong-Tae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.23 no.5
    • /
    • pp.479-486
    • /
    • 2013
  • There exist two major difficulties in developing flight control system: nonlinear dynamic characteristics and time-varying properties of parameters of aircraft. Instead of the difficulties, many high reliable and efficient control methodologies have been developed. But, most of the developed control systems are based on the exact mathematical modelling of aircraft and, in the absence of such a model, it is very difficult to derive performance, robustness and nominal stability. From these aspects, recently, some approaches to utilizing the intelligent control theories such as fuzzy logic control, neural network and genetic algorithm have appeared. In this paper, one advanced intelligent lateral control system of a high speed fight has been developed utilizing type-2 fuzzy logic, which can deduce the uncertainty problem of the conventional fuzzy logic. The results will be verified through computer simulation.

Syllable Recognition of HMM using Segment Dimension Compression (세그먼트 차원압축을 이용한 HMM의 음절인식)

  • Kim, Joo-Sung;Lee, Yang-Woo;Hur, Kang-In;Ahn, Jum-Young
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.40-48
    • /
    • 1996
  • In this paper, a 40 dimensional segment vector with 4 frame and 7 frame width in every monosyllable interval was compressed into a 10, 14, 20 dimensional vector using K-L expansion and neural networks, and these was used to speech recognition feature parameter for CHMM. And we also compared them with CHMM added as feature parameter to the discrete duration time, the regression coefficients and the mixture distribution. In recognition test at 100 monosyllable, recognition rates of CHMM +${\bigtriangleup}$MCEP, CHMM +MIX and CHMM +DD respectively improve 1.4%, 2.36% and 2.78% over 85.19% of CHMM. And those using vector compressed by K-L expansion are less than MCEP + ${\bigtriangleup}$MCEP but those using K-L + MCEP, K-L + ${\bigtriangleup}$MCEP are almost same. Neural networks reflect more the speech dynamic variety than K-L expansion because they use the sigmoid function for the non-linear transform. Recognition rates using vector compressed by neural networks are higher than those using of K-L expansion and other methods.

  • PDF

Development of Chair Backrest for Non-intrusive Simultaneous Measurement of ECG and BCG (심전도와 심탄도의 무구속적 동시 측정을 위한 의자 등받이 개발)

  • Lim, Yong-Gyu
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.19 no.3
    • /
    • pp.104-109
    • /
    • 2018
  • A non-intrusive ECG and BCG measurement system is introduced. The system is built on a auxiliary backrest of a chair. The developed system is aimed to non-intrusive assessment of cardiovascular dynamic indices such as pulse arrival time(PAT) and pre-ejection period (PEP). In the system, capacitive active electrodes and capacitive grounding were used for the non-intrusive indirect-contact ECG measurement, and EMFi pressure sensor was used for the non-intrusive BCG measurement. The capacitive active electrodes and the EMFi sensor were attached on the backrest. Using the system, ECG and BCG were successfully acquired. The measured BCG showed peaks that following ECG R peaks. It was shown that the time interval between Q wave in ECG and first peak in BCG correlates Pre-ejection period measured by impedance-cardiogram. The results showed that the introduced system can be used for the non-intrusive various cardiovascular information including ECG, PAT, PEP.

Reliability and Responsiveness of the Korean Version of the Trunk Impairment Scale for Stroke Patients

  • Ko, Jooyeon;You, Youngyoul
    • The Journal of Korean Physical Therapy
    • /
    • v.27 no.4
    • /
    • pp.175-182
    • /
    • 2015
  • Purpose: The purposes of this study were to develop the Korean version of the trunk impairment scale (K-TIS) and to examine reliability and responsiveness of the K-TIS in patients with stroke. Methods Subjects of the study were 51 stroke patients (mean age: 57.78 years) recruited from two stroke clinics. For the interrater and test-retest reliability, two raters measured the K-TIS two times using video clips with an interval of 2 weeks. For the responsiveness, intensive physical therapy training was provided to all participants 2 times a day for one month or three months depending on the onset of the stroke and the admission rules of the two clinics. Inter-rater reliability and test-retest reliability of the K-TIS three subscales (static sitting balance, dynamic sitting balance, and coordination) scores and total scores were examined using intra-correlation coefficient ($ICC_{3,1}$) and Pearson's correlation coefficient (r). To examine responsiveness, the minimally important difference (MID) was calculated with effect size. Results: Inter-rater reliability of the K-TIS subscales and total scores were all high (ICC3,1=0.920-0.983 and r=0.924-0.984). For the test-retest reliability, $ICC_{3,1}$=0.805-0.901 and r=0.806-0.903, and the MID for acute and post-acute as well as chronic stroke patients remained in the mean change range. Conclusion: It is suggested that the K-TIS might be used for clinical and research purposes as a standardized tool for stroke patients. In addition, it can also be useful in establishment of treatment goal(s) and planning treatment program(s) for patients with stroke.

The Allocation Methods for Economical Efficiency Using an Optimized Model (최적화 모델을 이용한 경제적인 총량관리 할당기법 연구)

  • Choi, In Uk;Shin, Dong Seok;Kim, Hong Tae;Park, Jae Hong;Ahn, Ki Hong;Kim, Yong Seok
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.3
    • /
    • pp.295-303
    • /
    • 2015
  • In Korea, Total Maximum Daily Loads(TMDLs) has been enforced to restore and manage water quality in the watersheds. However, some assesment of implementation plan of TMDLs showed that the achievement of the target water quality is not related to the proper allocation loads because difference of flow duration interval. In the United States, the discharge loads are determined by water quality modeling considering standard flow conditions according to purpose. Therefore, this study tried to develop the allocation method considering economical efficiency using water quality model. For this purpose, several allocation methods being used in the management of TMDLs is investigated and develope an allocation criteria considering regional equality and uniformity. Since WARMF(Watershed Analysis Risk Management Framework) model can simulate the time varying behavior of a system and the various water quality variables, it was selected for a decision support system in this study. This model showed fairly good performance by adequately simulating observed discharge and water quality in Miho watershed. Furthermore, the scenario simulation results showed that the effect of annual average water quality improvement to remove 1kg BOD is more than 25 times, even if point pollutants treatment facility is six times more expensive to operate than non-point pollutants treatment facility.