• 제목/요약/키워드: dynamic compensator

검색결과 234건 처리시간 0.019초

동적 와인드엎 방지법에 기초한 상태 제한이 존재하는 시스템의 제어 방법 (Control Method for State Constrained Control Systems: Dynamic Anti-Widup Based Approach)

  • 박종구
    • 제어로봇시스템학회논문지
    • /
    • 제6권8호
    • /
    • pp.672-681
    • /
    • 2000
  • Based on the dynamic anti-windup strategy a novel control methodology for state constrained control systems is presented. First a linear controller is designed for an open-loop stable plant to show a desirable nominal performance by ignoring state constraints. And then an additional dynamic compensator is introduced to preserve the nominal performance as closely as possible int he face of state constraints. This paper focuses on the second step under the assumption that a linear controller has already been designed appropriately by using an effective controller design method. By minimizing a reasonable performance index the dynamic compensator is derived explicitly which is expressed int he plant and controller parameters. the proposed method not only guarantees the total stability of the overall resulting systems but also provides desirable output performance because it solves the state-positioning problem completely.

  • PDF

Mismatching Problem between Generic Pole-assignabilities by Static Output Feedback and Dynamic Output Feedback in Linear Systems

  • Kim Su-Wood
    • International Journal of Control, Automation, and Systems
    • /
    • 제3권1호
    • /
    • pp.56-69
    • /
    • 2005
  • In this paper, it is clearly shown that the two well-known necessary and sufficient conditions mp n as generic static output feedback pole-assignment and mp + d(m+p) n+d as generic minimum d-th order dynamic output feedback pole-assignment on complex field, unbelievably, do not match up each other in strictly proper linear systems. For the analysis, a diagram analysis is newly created (which is defined by the analysis of 'convoluted rectangular/dot diagrams' constructed via node-branch conversion of the signal flow graphs of output feedback gain loops). Under this diagram analysis, it is proved that the minimum d-th order dynamic output feedback compensator for pole-assignment in m-input, p-output, n-th order systems is quantitatively decomposed into static output feedback compensator and its associated d number of arbitrary 1st order dynamic elements in augmented (m+d)-input, (p+d)-output, (n+d)-th order systems. Total configuration of the mismatched data is presented in a Table.

제주-해남 HVDC 시스템에 STASTCOM 적용 타당성 분석 (Feasibility Analysis of STATCOM Application for Jeiu-Haenam HVDC System)

  • 백승택;추원교;한병문;장길수
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권8호
    • /
    • pp.401-409
    • /
    • 2005
  • This paper describes a feasibility analysis result of STATCOM application for the Jeju-Haenam HVDC system. The Jeju-Haenam HVDC system is one of the typical HVDC system interconnected with the low short-circuit-ratio AC system, which is vulnerable to the commutation failure due to the AC voltage variation. STATCOM has been considered as an effective reactive-power compensator to increase short-circuit-ratio of the interconnected AC system. In this study, a simulation model of Jeju-Hacnam HVDC system with STATCOM was developed using PSCAD/EMTDC. The developed simulation model was utilized to analyze the dynamic performance analysis of Jeju-Haenam HVDC system with STATCOM. The analysis results show that STATCOM can improve the dynamic performance of Jeju-Haenam HVDC system, such as load-change recovery performance and fault recovery performance.

Slewing maneuver control of flexible space structure using adaptive CGT

  • Shimada, Yuzo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1995년도 Proceedings of the Korea Automation Control Conference, 10th (KACC); Seoul, Korea; 23-25 Oct. 1995
    • /
    • pp.47-50
    • /
    • 1995
  • This paper concerns an adaptive control scheme which is an extension of the simplified adaptive control. Originally, the SAC approach was developed based on the command generator tracker (CGT) theory for perfect model tracking. An attractive point of the SAC is that a control input can be synthesized without any prior knowledge about plant structure. However, a feedforward dynamic compensator of the CGT is removed from the basic structure of the SAC. This deletion of the compensator makes perfect model tracking difficult against even a step input. In this paper, an adaptive control system is redesigned to achieve perfect model tracking for as long as possible by reviving the dynamic compensator of the CGT. The proposed method is applied to slewing control of a flexible space structure and compared to the SAC responses.

  • PDF

An Enhanced Harmonic Voltage Compensator for General Loads in Stand-alone Distributed Generation Systems

  • Trinh, Quoc-Nam;Lee, Hong-Hee;Chun, Tae-Won
    • Journal of Power Electronics
    • /
    • 제13권6호
    • /
    • pp.1070-1079
    • /
    • 2013
  • This paper develops an enhanced harmonic voltage compensator which is implemented with the aid of two repetitive controllers (RCs) in order to improve the output voltage performance of stand-alone distributed generation (DG) systems. The proposed harmonic voltage compensator is able to maintain the DG output voltage sinusoidal regardless of the use of nonlinear and/or unbalanced loads in the load side. In addition, it can offer good steady-state performance under various types of loads and a very fast dynamic response under load variations to overcome the slow dynamic response issue of the traditional RC. The feasibility of the proposed control strategy is verified through simulations and experiments.

Fuzzy Control with Feedforward Compensator of Superheat in a Variable Speed Refrigeration System

  • Hua, Li;Lee, Dong-Woo;Jeong, Seok-Kwon;Yoon, Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권3호
    • /
    • pp.252-262
    • /
    • 2007
  • In this paper, we suggest fuzzy control with feedforward compensator of superheat to progress both energy saving and coefficient of performance(COP) in a variable speed refrigeration system. The capacity and superheat are controlled simultaneously and independently by an inverter and an electronic expansion valve respectively for saving energy and improving COP in the system. By adopting the fuzzy control. the controller design for the capacity and superheat is possible without depending on a dynamic model of the system. Moreover, the feedforward compensator of the superheat can eliminate influence of the interfering loop between capacity and superheat. Some experiments are conducted to design the appropriate fuzzy controller by an iteration manner. The results show that the proposed fuzzy controller with the compensator can establish good control performances for the complicated refrigeration system with inherent strong non-linearity.

Sliding Mode Control with Fuzzy Adaptive Perturbation Compensator for 6-DOF Parallel Manipulator

  • Park, Min-Kyu;Lee, Min-Cheol;Yoo, Wan-Suk
    • Journal of Mechanical Science and Technology
    • /
    • 제18권4호
    • /
    • pp.535-549
    • /
    • 2004
  • This paper proposes a sliding mode controller with fuzzy adaptive perturbation compensator(FAPC) to get a good control performance and reduce the chatter, The proposed algorithm can reduce the chattering because the proposed fuzzy adaptive perturbation compensator compensates the perturbation terms. The compensator computes the control input for compensating unmodeled dynamic terms and disturbance by using the observer-based fuzzy adaptive network(FAN) The weighting parameters of the compensate. are updated by on-line adaptive scheme in order to minimize the estimation error and the estimation velocity error of each actuator. Therefore, the combination of sliding mode control and fuzzy adaptive network gives the robust and intelligent routine to get a good control performance. To evaluate the control performance of the proposed approach, tracking control is experimentally carried out for the hydraulic motion platform which consists of a 6-DOF parallel manipulator.

약한 AC 계통에서 동기조상기용 여자 시스템 특성에 따른 HVDC 과도 특성 (Dynamic Performance of HVDC According to Excitation System Characteristics of Synchronous Compensator in a Weak AC System)

  • 김찬기;김정부;심응보
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권6호
    • /
    • pp.431-440
    • /
    • 2000
  • This paper analyses the dynamic performance of HVDC System connected to a weak AC system for various exciter characteristics of synchronous machines connected at the converter bus. Conventionally capacitors are used to supply reactive power requirement at a strong converter bus. But the installation of synchronous machine is essential in a isolated weak network to re-start after a shutdown of HVDC and to increase system strength. The dynamic performance of a synchronous machine depends on the characteristics depends of its exciter. In this paper, several exciter types are used to investigate their effect on the dynamic performance of the HVDC system and modifications to standard exciter topologies are suggested to mitigate observed problems.

  • PDF

Modeling and Control of VSI type FACTS controllers for Power System Dynamic Stability using the current injection method

  • Park, Jung-Soo;Jang, Gil-Soo;Son, Kwang-M.
    • International Journal of Control, Automation, and Systems
    • /
    • 제6권4호
    • /
    • pp.495-505
    • /
    • 2008
  • This paper describes modeling Voltage Sourced Inverter (VSI) type Flexible AC Transmission System (FACTS) controllers and control methods for power system dynamic stability studies. The considered FACTS controllers are the Static Compensator (STATCOM), the Static Synchronous Series Compensator (SSSC), and the Unified Power Flow Controller (UPFC). In this paper, these FACTS controllers are derived in the current injection model, and it is applied to the linear and nonlinear analysis algorithm for power system dynamics studies. The parameters of the FACTS controllers are set to damp the inter-area oscillations, and the supplementary damping controllers and its control schemes are proposed to increase damping abilities of the FACTS controllers. For these works, the linear analysis for each FACTS controller with or without damping controller is executed, and the dynamic characteristics of each FACTS controller are analyzed. The results are verified by the nonlinear analysis using the time-domain simulation.

무효전력 보상 용량 증대 및 DC 링크 전압 저감을 위한 SVC 결합형 UPQC (SVC coupled UPQC for reactive power compensation capacity increase and DC link voltage reduction)

  • 표수한;박장현;오정식;박태식
    • 전기전자학회논문지
    • /
    • 제23권1호
    • /
    • pp.99-106
    • /
    • 2019
  • 본 논문에서는 UPQC 시스템과 SVC를 결합한 새로운 형태의 보상장치를 제안하고자 한다. 기존의 UPQC는 직렬형 인버터, 병렬형 인버터, DC 링크로 구성되어 있어있으며 우수한 전력품질 보상 성능을 보이지만 높은 인버터 정격을 요구한다. 제안된 방식은 직렬형 인버터, 병렬형 인버터와 DC 링크 그리고 병렬형 인버터의 출력단에 결합된 SVC로 구성되어 있으며, 기존 UPQC에 비해 넓은 무효전력 보상 범위와 낮은 DC 링크 전압의 장점을 가지고 있다. 또한, SVC가 결합된 새로운 UPQC의 구성은 Matlab 시뮬레이션을 통해 성능을 검증하였다.