• Title/Summary/Keyword: dynamic compensator

Search Result 234, Processing Time 0.026 seconds

Sag Voltage Compensator using Diode Rectifier and Series Inverter (다이오드 정류기와 인버터를 이용한 순간 전압 강하 보상기)

  • 이준기;박덕희;김희중;한병문;소용철
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.448-451
    • /
    • 1999
  • This paper describes controller development for a dynamic voltage compensator using a shunt diode converter and series inverter. The control system was designed using 1/4 period integrator and vector relationship between the supply voltage and load voltage. A simulation model and scaled hardware model were developed for analyzing performance of the controller and the whole system. Both results confirm that the dynamic compensator can restore the load voltage under the fault of the distribution system.

  • PDF

Speed Control of DC Motor by a Nonlinear Compensator Describing the CDIDF (CDIDF로기전된 비선형신형기에 의한 직유전동기의 속도제어)

  • Hyoung-Ki Lee;Hong-Gon Ha;Byung-Do Yoon
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.37 no.2
    • /
    • pp.130-137
    • /
    • 1988
  • The technique of dual-input describing function's synthesis is introduced and the construction of a nonlinear compensator, based on this technique, is proposed. A nonlinear compensator, describing a complex DIDF depending upon amplitude of the second sinusoidal input signal only, is also proposed, where the second sinusoidal input signal is supplied to the nonlinear compensator by external generator. This compensator, connected in a closed loop of the PI speed control of DC motor, can improve the speed response in view instability limit cycle, low speed response and disturbance of the dynamic shift of the Nyquist's critical point -1 + j O. It is verified theoretically that the improvement of speed response of DC motor using the proposed compensator is achieved by means of the dynamic shift of the Nyquist's critical point on the complex plane, and the speed characterstics of DC motor is to be tested through experiment for its performance.

Design of active power factor control AC/DC converter having current control loop with no compensator (전류 제어 루프에 보상을 행하지 않는 능동 역률 제어 AC/DC 컴버터의 제어기 설계)

  • 이인호;김성환;유지윤;박귀태
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.2
    • /
    • pp.216-223
    • /
    • 1996
  • The active power factor control AC/DC converter needs a current loop compensator to obtain better dynamic characteristics and power factor performance, but the optimal design of a current loop compensator is difficult because the AC/DC converter is a nonlinear system having periodically varying poles and zeros. The predictive current control scheme generates a control input using the dynamic equations of the AC/DC converter so that the dynamic of the AC/DC converter is included in the controller and the necessary bandwidth and the gain characteristics of the current control loop are satisfied. And as a result, a compensator becomes unnecessary and the current loop shows the improved current loop characteristics. In this paper, a power factor controller without current loop compensator by adopting a predictive current control scheme is designed and the designed power factor controller is modelled by using a small signal perturbation modelling technique, and simulated to investigate its small signal characteristics. A 200 W power factor control AC/DC converter is built to verify the effectiveness of the proposed power factor controller.

  • PDF

Robust regulator design for an interval plant (구간 플랜트에 대한 견실한 레귤레이타 설계)

  • 김기두;김석중
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.173-178
    • /
    • 1993
  • In this paper, we present an algorithmic technique for determining a feedback compensator which will stabilize the interval dynamic system, specifically, the robust regulator design for interval plants. The approach taken here is to allow the system parameters to live within prescribed intervals then design a dynamic feedback compensator which guarantees closed-loop system stable. The main contribution of this paper is the idea of introducing a "simplified Kharitonov's result" for low order polynomials to search for suitable compensator parameters in the compensator parameter space to make the uncertain syste robust. We also design the robust regulator which will D-stabilize (have the closed-loop poles in the left sector only) the dynamic interval system while having good performance. The nuerical examples are given to show the substantially improved robustness which results from our approach. approach.

  • PDF

Robust Regulator Design for an Interval Plant (구경 플랜트에 대한 강건한 레귤레이터의 설계)

  • 김기두;김석중;조한유
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.8
    • /
    • pp.64-73
    • /
    • 1994
  • In this paper we present an algorithmic technique for determining a feedback compensator which will stabilize the interval dynamic system specifically the robust regulator design for interval plants. The approach taken here is to allow the system parameters to live within prescribed intervals then design a dynamic feedback compensator which guarantees closed-loop system stable. The main contribution of this paper is the idea of introducting a "simplified Kharitonov`s results" for low order polynomials to search for suitable compensator parameters in the compensator parammeter space to make the uncertain system robust. We also design the robust regulator which will $D_{\phi}$ -stabilize (have the closed-loop poles in the left sector only) the dynamic interval system while having good performance. the numerical examples are given to show the substantially improved robustness which results from our approach.

  • PDF

Dynamic Compensation Method for State Delayed Control Systems with Input Saturation (입력제한이 존재하는 상태지연 시스템의 동적보상방법)

  • Park, Jong-Koo
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.7
    • /
    • pp.325-331
    • /
    • 2001
  • A dynamic anti-windup method for state delayed control systems with input saturation is considered. Under the assumption that a linear controller has been designed for a state delayed control system based on the existing design technique which shows desirable nominal performance, an additional compensator is incorporated to provide a graceful performance degradation despite of input saturation. By regarding the difference of the controller states in the absence and presence of input saturation as an objective function, the dynamic compensator which minimizes it is determined explicitly. The proposed dynamic compensator is the closed form of plant and controller parameters. The proposed method not only provides graceful performance degradation, but it also guarantees the total stability of resulting systems. An illustrative example is provided to show the effectiveness of the proposed method.

  • PDF

Position Control of a Pneumatic Cylinder with a Nonlinear Compensator and a Disturbance Observer (비선형 보상기와 외란관측기를 이용한 공기압 실리더의 위치제어)

  • Jang, Ji-Seong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.9
    • /
    • pp.1795-1805
    • /
    • 2002
  • A position controller which can achieve a specified dynamic performance irrespective of the different operating position of the pneumatic cylinder is proposed. The position controller developed in this paper is composed of a nonlinear compensator and a disturbance observer. The nonlinear compensator which feeds back position, velocity and acceleration is derived from the nonlinear dominating equations of the position control system to compensate for variation of dynamic characteristics of a pneumatic cylinder according to the change of the operating position. The disturbance observer including a simplified linear model is designed to reduce the effect of model discrepancy in the low frequency range which cannot be suppressed by the nonlinear compensator. The results of the experiments show that the position control performance maintains a designed performance regardless of the variations of an operating position of the pneumatic cylinder.

Algebraic compensator design for dynamic systems using a novel BPF transformation method (새로운 BPF 변환식을 이용한 동적 시스템의 대수적 보상기 설계)

  • Ahn, P.;Kim, M.H.;Kim, J.B.;Lee, J.C.;Oh, M.H.;Ahn, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07b
    • /
    • pp.595-597
    • /
    • 1998
  • This paper deals with an algebraic compensator design for dynamic systems using a novel BPF transformation method. To obtain an algebraic compensator for the system, block pulse function's differential operation is used. Compare to unalgebraic compensator, proposed algebraic compensator is less sensitive to the measurement noise.

  • PDF

A Dynamic Anti-windup Scheme for Input-constrained Feedback Linearizable Nonlinear Systems (궤환선형화 가능한 비선형 시스템의 입력제한을 고려한 동적 와인드엎 방지)

  • 윤성식;박종구;윤태웅
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.534-534
    • /
    • 2000
  • This paper proposes a dynamic compensation scheme for input-constrained feedback linearizable nonlinear systems to cope with the windup phenomenon. Given a feedback linearizing controller for such a nonlinear system designed without considering its input constraint, an additional dynamic compensator is proposed to account for the constraint. This dynamic anti-windup is based on the minimization of a reasonable performance index, and some stability properties of the resulting closed-loop are presented.

  • PDF

Dynamic Voltage Compensator using Series and Shunt Inverters (직.병렬 인버터를 이용한 동적전압보상기)

  • Park, Deok-Hui;Lee, Jun-Gi;Han, Byeong-Mun;So, Yong-Cheol;Kim, Hyeon-U
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.11
    • /
    • pp.655-662
    • /
    • 1999
  • This paper describes controller design and simulation-model development of a dynamic voltage compensator using series and shunt inverters. The control system was designed using PI controller and vector relationship between the supply voltage and load voltage. A simulation model with EMTP was developed to analyze performance of the controller and the whole system. The simulation and experiment results confirm that the dynamic compensator can restore the load voltage under the fault of the distribution system, such as single-line-ground fault, three-line-to-ground fault, and line-to-line fault.

  • PDF