• Title/Summary/Keyword: dynamic building simulation

Search Result 239, Processing Time 0.025 seconds

Investigation on damage development of AP1000 nuclear power plant in strong ground motions with numerical simulation

  • Chen, Wanruo;Zhang, Yongshan;Wang, Dayang;Wu, Chengqing
    • Nuclear Engineering and Technology
    • /
    • v.51 no.6
    • /
    • pp.1669-1680
    • /
    • 2019
  • Seismic safety is considered to be one of the key design objectives of AP1000 nuclear power plant (NPP) in strong earthquakes. Dynamic behavior, damage development and aggravation effect are studied in this study for the three main components of AP1000 NPP, namely reinforced concrete shield building (RCSB), steel vessel containment (SVC) and reinforced concrete auxiliary building (RCAB). Characteristics including nonlinear concrete tension and compressive constitutions with plastic damage are employed to establish the numerical model, which is further validated by existing studies. The author investigates three earthquakes and eight input levels with the maximum magnitude of 2.4 g and the results show that the concrete material of both RCSB and RCAB have suffered serious damage in intense earthquakes. Considering RCAB in the whole NPP, significant damage aggravation effect can be detected, which is mainly concentrated at the upper intersection between RCSB and RCAB. SVC and reinforcing bar demonstrate excellent seismic performance with no obvious damage.

Optimal Scheduling for Dynamic Ice Storage System with Perfectly Predicted Cooling Loads (동적제빙형 빙축열시스템에 대한 최적운전계획)

  • Lee, Kyoung-Ho;Lee, Sang-Ryoul;Choi, Byoung-Youn;Kwon, Seong-Chul
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.286-291
    • /
    • 2001
  • This paper describes an optimal scheduling for ice slurry systems for energy cost saving. The optimization technique applied in the study is the dynamic programming method, for which the state variable is the storage in the ice storage tank and the control variable is the state of chiller's on-off switching. Though the costs during charge period is included in optimization by taking the average cost of ice per hour for slurry making, the time horizon for the simulation is limited building cooling period because accurate charge rate from the ice maker into the ice storage tank cannot be estimated during the charge period. In the operating simulation after optimizing procedure, energy consumption and operating cost for the optimal control are calculated and compared with them for a conventional control with one case of cooling load profile.

  • PDF

A methodology for development of seismic fragility curves for URBM buildings

  • Balasubramanian, S.R.;Balaji, Rao K.;Meher, Prasad A.;Rupen, Goswami;Anoop, M.B.
    • Earthquakes and Structures
    • /
    • v.6 no.6
    • /
    • pp.611-625
    • /
    • 2014
  • This paper presents a simple methodology that integrates an improved storey shear modelling, Incremental Dynamic Analysis and Monte Carlo Simulation in order to carryout vulnerability analysis towards development of fragility curves for Unreinforced Brick Masonry buildings. The methodology is demonstrated by developing fragility curves of a single storey Unreinforced Brick Masonry building for which results of experiment under lateral load is available in the literature. In the study presented, both uncertainties in mechanical properties of masonry and uncertainties in the characteristics of earthquake ground motion are included. The research significance of the methodology proposed is that, it accommodates a new method of damage grade classification which is based on 'structural performance characteristics' instead of 'fixed limiting values'. The usefulness of such definition is discussed as against the existing practice.

The Control of Temperature of Green Roof System with the Roof Slab Insulation Method (옥상슬래브 단열조건에 따른 옥상녹화의 열환경 조정효과)

  • Yeo, In-Ae;Cho, Hong-Je;Yoon, Seong-Hwan
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.869-872
    • /
    • 2008
  • On this study, the Control of Temperature is specified on the view of indoor comfort and building energy consumption. It is estimated by Dynamic heat load simulation which has the factors of insulation method and the soil thickness of the green roof system. The fact that the model which has no insulation has the greatest effect of dropping high temperature and the cooling load decrease is confirmed.

  • PDF

Enabling role of hybrid simulation across NEES in advancing earthquake engineering

  • Gomez, Daniel;Dyke, Shirley J.;Maghareh, Amin
    • Smart Structures and Systems
    • /
    • v.15 no.3
    • /
    • pp.913-929
    • /
    • 2015
  • Hybrid simulation is increasingly being recognized as a powerful technique for laboratory testing. It offers the opportunity for global system evaluation of civil infrastructure systems subject to extreme dynamic loading, often with a significant reduction in time and cost. In this approach, a reference structure/system is partitioned into two or more substructures. The portion of the structural system designated as 'physical' or 'experimental' is tested in the laboratory, while other portions are replaced with a computational model. Many researchers have quite effectively used hybrid simulation (HS) and real-time hybrid simulation (RTHS) methods for examination and verification of existing and new design concepts and proposed structural systems or devices. This paper provides a detailed perspective of the enabling role that HS and RTHS methods have played in advancing the practice of earthquake engineering. Herein, our focus is on investigations related to earthquake engineering, those with CURATED data available in their entirety in the NEES Data Repository.

Simulation and Verification Experiment of Cooling and Heating Load for a Test Space with Forced Ventilation (강제환기가 적용된 시험공간에서 냉난방부하의 시뮬레이션 및 실증실험)

  • Kim, Dong-Hyuk;Hong, Hi-Ki;Yoo, Ho-Seon;Kim, Ook-Joong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.12
    • /
    • pp.947-954
    • /
    • 2006
  • Building energy consumption according to the ventilation has been considered to be an important subject. The purpose of this study is to investigate the cooling and heating loads in a test space with a forced ventilating system. In the test space, on/off controlled air-conditioning and forced ventilating facility were operated between 8 : 30 to 21 : 00 during 4 days and some important data like temperatures and energy consumption were measured to obtain actual thermal loads. The simulation was carried out in a mode of temperature level control using a TRNSYS 15.3 with a precisely measured air change amount and performance data of air-conditioner. Heating load and cooling load including sensible and latent were compared between by experiment and by simulation. Both of thermal loads associated with ventilation show a close agreement within an engineering tolerance.

Aerodynamic and Flow Characteristics of Tall Buildings with Various Unconventional Configurations

  • Tanaka, Hideyuki;Tamura, Yukio;Ohtake, Kazuo;Nakai, Masayoshi;Kim, Yong Chul;Bandi, Eswara Kumar
    • International Journal of High-Rise Buildings
    • /
    • v.2 no.3
    • /
    • pp.213-228
    • /
    • 2013
  • Tall buildings have been traditionally designed to be symmetric rectangular, triangular or circular in plan, in order to avoid excessive seismic-induced torsional vibrations due to eccentricity, especially in seismic-prone regions like Japan. However, recent tall building design has been released from the spell of compulsory symmetric shape design, and free-style design is increasing. This is mainly due to architects' and structural designers' challenging demands for novel and unconventional expressions. Another important aspect is that rather complicated sectional shapes are basically good with regard to aerodynamic properties for crosswind excitations, which are a key issue in tall-building wind-resistant design. A series of wind tunnel experiments and numerical simulation have been carried out to determine aerodynamic forces and wind pressures acting on tall building models with various configurations: corner cut, setbacks, helical and so on. Dynamic wind-induced response analyses of these models have also been conducted. The results of these experiments have led to comprehensive understanding of the aerodynamic characteristics of tall buildings with various configurations.

A genetic algorithm with uniform crossover using variable crossover and mutation probabilities (동적인 교차 및 동연변이 확률을 갖는 균일 교차방식 유전 알고리즘)

  • Kim, Sung-Soo;Woo, Kwang-Bang
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.3 no.1
    • /
    • pp.52-60
    • /
    • 1997
  • In genetic algorithms(GA), a crossover is performed only at one or two places of a chromosome, and the fixed probabilities of crossover and mutation have been used during the entire generation. A GA with dynamic mutation is known to be superior to GAs with static mutation in performance, but so far no efficient dynamic mutation method has been presented. Accordingly in this paper, a GA is proposed to perform a uniform crossover based on the nucleotide(NU) concept, where DNA and RNA consist of NUs and also a concrete way to vary the probabilities of crossover and mutation dynamically for every generation is proposed. The efficacy of the proposed GA is demonstrated by its application to the unimodal, multimodal and nonlinear control problems, respectively. Simulation results show that in the convergence speed to the optimal value, the proposed GA was superior to existing ones, and the performance of GAs with varying probabilities of the crossover and the mutation improved as compared to GAs with fixed probabilities of the crossover and mutation. And it also shows that the NUs function as the building blocks and so the improvement of the proposed algorithm is supported by the building block hypothesis.

  • PDF

A framework for distributed analytical and hybrid simulations

  • Kwon, Oh-Sung;Elnashai, Amr S.;Spencer, Billie F.
    • Structural Engineering and Mechanics
    • /
    • v.30 no.3
    • /
    • pp.331-350
    • /
    • 2008
  • A framework for multi-platform analytical and multi-component hybrid (testing-analysis) simulations is described in this paper and illustrated with several application examples. The framework allows the integration of various analytical platforms and geographically distributed experimental facilities into a comprehensive pseudo-dynamic hybrid simulation. The object-oriented architecture of the framework enables easy inclusion of new analysis platforms or experimental models, and the addition of a multitude of auxiliary components, such as data acquisition and camera control. Four application examples are given, namely; (i) multi-platform analysis of a bridge with soil and structural models, (ii) multiplatform, multi-resolution analysis of a high-rise building, (iii) three-site small scale frame hybrid simulation, and (iv) three-site large scale bridge hybrid simulation. These simulations serve as illustrative examples of collaborative research among geographically distributed researchers employing different analysis platforms and testing equipment. The versatility of the framework, ease of including additional modules and the wide application potential demonstrated in the paper provide a rich research environment for structural and geotechnical engineering.

Analysis of PCM Wallboards Design Parameters using Dynamic Energy Simulation (동적 에너지 시뮬레이션을 이용한 PCM보드의 설계변수 분석에 관한 연구)

  • Lee, Jin-Uk;An, Sang-Min;Kim, Taeyeon;Lee, Seung-Bok
    • KIEAE Journal
    • /
    • v.12 no.4
    • /
    • pp.97-104
    • /
    • 2012
  • A phase-change material is a substance with a high heat of fusion which, melting and freezing at a certain temperature, is capable of storing and releasing large amounts of energy. Heat is absorbed or released when the material changes from solid to liquid. Therefore, PCMs are classified as latent heat storage (LHS) units. The purpose of this study is to analyze PCM wallboard design parameters using dynamic energy simulation. Among the factors of PCM, melting temperature, latent heat, phase change range, thermal conductivity are very important element to maximize thermal energy storage. In order to analyze these factors, EnergyPlus which is building energy simulation provided by department of energy from the U.S is used. heat balance algorithm of energy simulation is conduction finite difference and enthalpy-temperature function is used for analyzing latent heat of PCM. The results show that in the case of melting temperature, the thermal energy storage could be improved when the melting temperature is equal to indoor surface temperature. It seems that when the phase change range is wide, PCM can store heat at a wide temperature, but the performance of heat storage is languished.