• 제목/요약/키워드: dynamic SPECT

검색결과 23건 처리시간 0.029초

공정 내 기포가 산업용 SPECT의 성능에 미치는 영향 (Influence of Void on Performance of Industrial SPECT System)

  • 박장근;정성희;김종범;문진호;김찬형
    • 방사선산업학회지
    • /
    • 제8권1호
    • /
    • pp.23-27
    • /
    • 2014
  • Industrial single photon emission computed tomography (SPECT) is an useful technique to investigate the dynamic behavior of process flow. In the present study, to evaluate the influence of a void on the performance of industrial SPECT, industrial SPECT with various radioisotope sources and gas holdups was modeled by the Monte Carlo simulation. The results are very encouraging; that is, the void little influences the performance of industrial SPECT, which means that industrial SPECT could be a suitable tool to investigate the dynamic characteristics of the flow in a water-air phase process.

범용 신틸레이터 감마카메라와 심근전용 반도체 감마카메라의 성능 비교 연구 (Compared Performance of Semiconductor SPECT in Myocardial Perfusion SPECT: Phantom study)

  • 반영각;황동훈;김정열;강천구;김재삼
    • 핵의학기술
    • /
    • 제20권2호
    • /
    • pp.49-53
    • /
    • 2016
  • 최근 Cadmium-zinc-telluride (CZT) 반도체를 이용한 심장전용 감마카메라가 심장 핵의학 검사에 사용되고 있다. 본 연구는 기존 NaI(Tl) 신틸레이터를 사용한 감마카메라와 성능을 비교해 보고자 한다. CZT반도체를 사용한 심장전용 감마카메라(DSPECT, Spectrum-dynamic)와 범용 신틸레이터 SPECT 감마카메라(Infinia, GE)를 사용하여 연구를 진행했다. 방사성 동위원소는 $^{99m}TcO^{-4}$를 사용하고, 일반 임상 심장핵의학 검사에 사용된 조건을 실험 조건으로 설정 했다. NEMA 2001, 3 line phantom을 사용하여 반치폭(full width at half maximum, FWHM)을 측정하여 공간분해능(Spatial resolution)을 비교했다. 심장 팬텀을 사용하여 대조도대잡음비(Contrast to noise, CNR)를 비교하여 영상을 평가했다. 그리고 팬텀의 시간 당 MBq당 계수를 측정하여 민감도도 평가했다. NaI (Tl) 신틸레이터를 사용한 범용SPECT 감마카메라와 CZT 반도체를 사용한 심장 전용 감마카메라의 영상평가에서 감도는 $52.83counts{\cdot}sec^{-1}{\cdot}MBq^{-1}$$195.83counts{\cdot}sec^{-1}{\cdot}MBq^{-1}$로 나왔고, 공간분해능은 16.90 mm과 9.47 mm로 나왔다. 그리고 대조도대 잡음비는 3.6 과 4.2 로 나왔다. 기존 카메라를 이용한 심장 핵의학 영상과 비교하여 CZT를 사용한 심장 전용 감마카메라는 감도 및 공간분해능, 대조도대잡음비가 기존 감마카메라와 비교하여 월등하여 임상에서 환자의 피폭선량 저감과 검사 시간 단축, 높은 분해능의 영상으로 환자 만족도에 큰 영향을 줄 것으로 사료 된다.

  • PDF

Brain SPECT 검사 시 Dynamic Continuous Mode의 유용성 평가 (The Evaluation of Dynamic Continuous Mode in Brain SPECT)

  • 박선명;김수영;최성욱
    • 핵의학기술
    • /
    • 제21권1호
    • /
    • pp.15-22
    • /
    • 2017
  • 본원에서 시행하는 Brain SPECT 검사는 $^{99m}Tc-ECD$ 또는 $^{99m}Tc-HMPAO$를 주사 한 후 뇌 영상을 얻어 뇌 관류상태를 평가하는 검사이다. 하지만 검사 중 일부 환자 상태가 불안정할 경우 움직임이 발생하여 재촬영이나 검사실패로 이어지는 경우가 발생 된다. 이에 현재의 Step and Shoot Mode(SSM)이 아닌 움직임이 발생되더라도 재구성을 통해 영상 구현이 가능한 Dynamic Continuous Mode(DCM)를 적용하여 환자의 재촬영과 피폭선량을 감소시키고 검사실에 운영 효율성을 높이고자함에 있다. Deluxe PET/SPECT Phantom과 Hoffman 3D Brain Phantom으로 Filtered Back Projection(FBJ)과 Iterated Reconstruction(IR)으로 재구성하여 영상을 구현하였다. 이미지를 가지고 핵의학과 5년이상의 임상경력이 있는 의사 5명과 방사선사 5명을 대상으로 리커트 5점 척도(Likert 5 Scale)와 블라인드 판독 테스트를 실시 하였다. 판독의 블라인드 테스트 결과 최소 DCM 3Repeat (30%)에서 7Repeat (50%)까지 판독에 영향을 주지 않는다고 답해 주었다. DCM으로 검사 시 환자 움직임이 발생되면 불필요한 부분을 제거하여 재촬영, 재주사의 감소를 가져올 수 있고, 장비 오류 시 영상을 재구성 후 구현 할 수 있어 검사실 운영 효율도 높을 수 있을 것으로 기대된다. 또한 SPECT검사뿐 만 아니라 SPECT/CT검사 에서도 활발한 연구가 적용 될 거라 기대 되며 마지막으로 실제 환자 적용은 환자 데이터의 충분한 수집 후 병원 판독 실정에 맞게 도입이 필요 하리라 사료된다.

  • PDF

동적 심근관류 SPECT에서 심장의 위치 측정방법에 대한 고찰 (An Optimization Method of Measuring Heart Position in Dynamic Myocardial Perfusion SPECT with a CZT-based camera)

  • 성지혜;이동훈;김은혜;정우영
    • 핵의학기술
    • /
    • 제23권1호
    • /
    • pp.75-79
    • /
    • 2019
  • 관상동맥 혈류예비능(CFR)은 관상동맥 협착에 대한 기능적 평가를 하는데 중요한 지표로 사용되고, 허혈성 심장질환(IHD)의 발생을 조기에 진단할 수 있다. 최근 도입된 Discovery NM 530c (D530c) 장비의 구조적 특성으로 인해 동적인 영상 획득이 가능해졌고, 심근 혈류 및 관상동맥 혈류예비능의 측정을 할 수 있게 되었다. D530c 19개 CZT 검출기의 FOV가 교차되는 영역을 QFOV라고 하며, 영상의 질을 위해 QFOV 중앙으로부터 2 cm 이내 심장을 위치시키고 촬영할 것을 권고하고 있다. 동적 심근관류 SPECT 시에 심장의 위치를 선정하기 위한 최적화된 방법을 연구하였다. 심장의 위치를 측정하기 위한 도구로 이동형 초음파를 이용하였다. 환자는 parasternal long-axis view (PLAX) 스캔하였고, 심장 내 구조물이 잘 보이는 탐촉자 지점에 위치를 표시하였다. 환자의 신체에 표시한 지점과 D530c 검출기에 표시된 기준점을 서로 일치시킨 상태에서 약물부하(stress)를 하였고, 방사성동위원소를 순간주사(bolus injection) 하면서 동적 촬영을 시행하였다. 3시간 경과 후, 휴지기(rest) 촬영 시 QFOV 중앙에 심장이 위치하도록 조정하였다. 테이블 및 검출기 위치에 대하여 이동형 초음파를 이용한 dynamic stress와 QFOV 중앙에 위치시킨 rest의 좌표를 비교 분석한 결과, 모든 항목에서 통계적으로 유의한 차이가 없었다(P > 0.05). 이동형 초음파의 이용은 비교적 사용이 간편하면서 시간 단축과 함께 공간의 제약이 없었고, 심장의 정확한 위치 선정에 도움이 되었다. 이는 영상의 질향상과 환자의 불필요한 방사선 피폭을 최소화하고, 심근혈류 및 관상동맥 혈류예비능의 정량적 평가에 도움을 줌으로써 임상적 진단에 효과적일 것으로 사료된다.

초음파상 비전형적 소견을 보이는 간혈관종의 적혈구 표지 스캔소견 ($^{99m}Tc-Red$ Blood Cell Scintigraphy of Sonographically Atypical Hemangioma)

  • 이경수;이지영;김찬수;김창근;최시성;원종진
    • 대한핵의학회지
    • /
    • 제26권2호
    • /
    • pp.338-345
    • /
    • 1992
  • We evaluated the scintigraphic findings of sonographically atypical hemangioma, that is, a hypoechoic or heterogeneously hypoechoic nodule which contains hypoechoic areas more than 40% of the volume, and compared it with those of sonographically typical hemangioma in 26 patients with 31 nodules. Sonographically atypical hemangioma were 13 in 11 patients and sonographically typical hemangioma were 18 the 15 patients. Dynamic blood flow, planar and SPECT blood pool imaging was performed. In atypical hemangioma, increased blood pool activity was seen in 11 of 13 nodules on SPECT and in 10 of 13 nodules on planar image and increased blood flow was seen in 4 of 13 nodules on dynamic blood flow study. No significant difference in detecting increased blood pool activity between sonographically atypical and typical hemangioma. In conclusion, $^{99m}Tc-red$ blood cell SPECT is as useful in diagnosis of sonographically atypical hemangioma as in typical hemangioma and can be used as a confirmatory or complementary study.

  • PDF

[Tc-99m]TRODAT-1과 [I-123]IPT SPECT를 이용한 도파민 운반체의 영상화 및 정량분석 비교 (Comparison Studies of SPECT Dopamine Transporter Imaging and Noninvasive Quantification using [Tc-99m]TRODAT-1 and [I-123]IPT)

  • 김희중;봉정균;이희경
    • 대한핵의학회지
    • /
    • 제32권1호
    • /
    • pp.10-19
    • /
    • 1998
  • The SPECT radiopharmaceuticals labeled with I-123 for dopamine transporter imaging have been used to measure dopamine transporters in patients with movement disorders. However, a cyclotron produced I-123 limits its availiability and ease of use as a radioisotope to be labeled with pharmaceuticals in routine clinical diagnostic procedures. Recently, new radiophannaceuticals for Tc-99m which has optimal characteristic for SPECT imaging have been developed to overcome the limits of using I-123. The purpose of this study was to compare the quality of [Tc-99m]TRODAT-1 with [I-123]IPT SPECT data and then to evaluate the usefulness of [Tc-99m]TRODAT-1 SPECT by using three noninvasive simplified quantitative methods. TRODAT-1 labeled with Tc-99m($15.93{\pm}0.82mCi$) and IPT labeled with I-123($6.60{\pm}0.11mCi$) were injected into five normal controls. Dynamic [Tc-99m]TRODAT-1 SPECT scans of brain were performed for 10 minutes each over 180 minnutes, and for 20 minutes at 4 hrs and 5 hrs. [I-123]IPT SPECT scans were performed for 5 minutes each over 120 minutes. Time activity curves were generated for the left basal ganglia(LBG), right basal ganglia(RBG), and occipital cortex(OCC). Dopamine transporter parameters were ohtained using (BG-OCC)/OCC, graphical method($R_V$), and area ratio method($R_A$). TRODAT-1 and IPT SPECT imaging showed high uptake at the level of the basal ganglia. (BG-OCC)/OCC ratios for TRODAT-1 and IPT were $0.80{\pm}0.14$, and $3.22{\pm}0.81$, $R_Vs$ were $0.62{\pm}0.12$, and $2.30{\pm}0.35$, and $R_As$ were $0.37{\pm}0.08$ and $1.73{\pm}0.31$, respectively. In conclusion, further improvement of [Tc-99m]TRODAT-1 imaging characteristics may be required to estimate the dopamine transporter concentrations in human brains although it shows clear BG localization.

  • PDF

두경부 혈관종 진단시 $^{99m}Tc$-RBC Scan and SPECT 검사의 유용성 (Usefulness of $^{99m}Tc$-labeled RBC Scan and SPECT in the Diagnosis of Head and Neck Hemangiomas)

  • 오신현;노동욱;안샤론;박훈희;이승재;강천구;김재삼;이창호
    • 핵의학기술
    • /
    • 제12권1호
    • /
    • pp.39-43
    • /
    • 2008
  • 혈관종의 진단에 초음파(US), 전산화단층촬영영상(CT), 자기공명영상(MRI), 핵의학 검사 등 다양한 검사방법이 사용 될 수 있지만 $^{99m}Tc$ 표지 적혈구를 이용한 혈액풀 영상검사는 단일광자단층촬영(SPECT)의 발달로 혈관종을 확진하고 배제할 수 있는 가장 경제적일 뿐 아니라 비침습적이고 시행 하기도 쉬운 확실한 방법으로 사용되고 있다. 본 연구에서는 간 혈관종 외 두경부 (head and neck) 혈관종 진단시 $^{99m}Tc$-RBC scan and SPECT 검사의 유용성에 대하여 알아보고자 한다. 혈관종의 진단을 위해 본원 핵의학과에 내원한 6명의 환자를 대상으로 하였다. 6명의 환자 중 두부 부위 4명, 경부 부위 1명은 혈관종이라 추정하였고, 1명은 혈관종으로 의심되었다. 변형 체내 표지법(modified in vivo method)을 사용하여 표지하고 원심침전시켜 혈장을 제거한 다음 $^{99m}Tc$-RBC를 순 간주사하였다. 혈류기 영상을 얻은 후 즉시 전면상, 후면상, 양측면상의 혈액풀 영상을 얻었고 4시간 후 동일한 지연 영상을 얻었다. SPECT 영상은 이중 검출기(dual head detector)를 이용하여 64 projections ($180^{\circ}$)을 시행하였고 각 projection당 30초간 집적하였다. 모든 영상을 재구성한 후에 3명의 핵의학과 전문의, 핵의학과 전공의 및 핵의학과 방사선사가 특별한 정보없이 영상을 검토하였다. 혈관종으로 추정된 5명의 환자는 혈류기 영상에서 방사능은 증가하지 않았고 혈액풀 영상에서 증가하였으며 지연 영상과 SPECT 영상에서 증가된 소견을 보여 전형적인 혈관종 소견을 보였다. 혈관종이 아닌 1명의 환자는 혈류기 영상과 혈액풀 영상에서 방사능 증가를 보였고, 지연 영상과 SPECT 영상에서 감소된 소견을 보여 혈관종이 아닌 것으로 판정되었다. 5명의 혈관종 환자의 병소 크기는 모두 2 cm 이상이었고 SPECT 영상이 지연영상과 비교하여 뚜렷하게 병소 감별을 할 수 있었다. 간혈관종뿐만 아니라 두경부 혈관종이 의심되는 경우에는 비교적 경제적이고 비침습적이며 쉽게 시행할 수 있는 $^{99m}Tc$-RBC scan and SPECT 검사를 시행함으로써 초음파, 전산화 단층촬영영상, 자기공명영상 검사와 같은 다른 영상진단법과 함께 혈관종을 확진하고 배제하는데 의미있는 영상의학적 정보를 제공할 수 있다고 사료된다.

  • PDF

동적 $H_2^{15}O$ PET에서 앙상블 독립성분분석법을 이용한 심근 혈류 정량화 방법 개발 (Development of Quantification Methods for the Myocardial Blood Flow Using Ensemble Independent Component Analysis for Dynamic $H_2^{15}O$ PET)

  • 이병일;이재성;이동수;강원준;이종진;김수진;최승진;정준기;이명철
    • 대한핵의학회지
    • /
    • 제38권6호
    • /
    • pp.486-491
    • /
    • 2004
  • 목적: 요소분석법. 독립성분분석법 등이 PET을 이용하여 심근혈류를 비침습적으로 측정하기 위하여 사용되어 왔다. 이론적으로 뛰어나고 새로운 방법인 앙상블 독려성분분석법을 이용하여 $H_2^{15}O$ 동적 심근 PET데이터의 정량분석방법을 개발하였다. 이 연구에서 사용한 앙상블 독려성분분석법을 이용하여 환자의 혈류를 정량화 하였다. 대상 및 방법: 관동맥질환이 의심되어 관류 SPECT를 시행한 환자 20명을 대상으로 $H_2^{15}O$ 동적 심근 PET을 시행한 후 앙상블 독립성분분석법을 이용하여 심근 독립성분영상을 추출하였으며, 좌심실영역과 심근영역에 대한 영상대조도를 조사하였다. 앙상블 학습은 독립성분과 가중치 행렬에 대한 확률분포를 가정하고 베이지안 이론에 의해서 혼합자료에 대한 확률분포를 추정한다. 이렇게 추정한 혼합자료의 확률분포와 실제 분포간의 차이인 Kullback-Leibler 발산치가 최소가 되도록 독립성분과 가중치 행렬을 순차적으로 변화시켜가며 최종 해를 찾는 방식이다. 이 연구에서 사후확률분포는 동적 핵의학 영상에 적합한 비음성제약조건과 함께 수정된 가우시안 분포를 이용하여 최적화 하였다. 혈류량은 심첨부, 중벽 네 부분, 하벽 네 부분의 9개 영역으로 나누어 측정하였으며, 측정결과에 대해 관류 SPECT 소견과 관동맥조영술의 소견과 비교하였다. 결과: 전체 20명의 휴식기 및 부하기 영상에서 5명을 제외한 15명의 데이터에 대해 심근혈류를 측정할 수 있었다. $H_2^{15}O$ 동적 심근 PET에서 앙상블 독립성분분석법을 이용하여 정량화한 휴식기 혈류량은 $1.2{\pm}0.40$ ml/min/g, 부하기 혈류량은 $1.85{\pm}1.12$ml/min/g이었다. 같은 영역에 대해 두 번 측정했을 때 측정된 심근혈류값의 상관계수는 0.99로 재현성이 높았다. 분리된 독립성분영상에서 영상대조도는 좌심실에 대한 심근영역의 비는 평균 1:2.7이었다. 관동맥 조영술을 시행한 9명에서 협착이 없는 분절과 협착이 있는 분절의 혈류예비능에 유의한 차이가 있었다(P<0.01). 또한, 관동맥조영술에서 협착이 확인된 66분절의 심근관류 SPECT 소견에서 가역적 혈류감소를 보인 분절의 혈류예비능이 더 많이 감소되는 경향을 보였으나 통계적 유의성을 보이지는 않았다. 결론: 앙상블 학습을 이용한 독립성분분석방법을 이용하여 심근혈류가 측정이 되었다. 앙상블 독립성분분석법을 이용한 $H_2^{15}O$ 동적 심근 PET 분석방법이 관상동맥 질환의 분석 및 동적 핵의학 영상 데이터의 연구에 도움이 될 것으로 기대된다.

[I-123]IPT SPECT를 이용한 정상인과 파킨슨 환자의 도파민 운반체의 영상화 및 단순화된 정량분석 방법들의 비교연구 (A Study of Dopamine Transporter Imaging and Comparison of Noninvasive Simplified Quantitative Methods in Normal Controls and Parkinson's Patients)

  • 봉정균;김희중;임주혁;양승오;문대혁;류진숙;남기표;천준홍;권수일;이희경
    • 대한핵의학회지
    • /
    • 제30권3호
    • /
    • pp.315-324
    • /
    • 1996
  • 목적 : 정상인과 파킨슨 환자의 [I-123]IPT SPECT 데이터를 이용하여 그래픽 분석방법과 축적된 특이결합과 비특이결합의 면적에 대한 비율을 이용한 분석방법으로 얻은 $k_3/k_4$와 조직방사능비를 비교하고 [I-123]IPT SPECT의 유용성을 알아보기 위한 것이다. 방법 : [I-123]IPT($6.5{\pm}1.1$ mCi)를 6명의 정상인(나이:$45{\pm}13$)과 17명의 파킨슨 환자(나이:$55{\pm}8$)에게 순간 정맥주사하였다. SPECT 데이터는 5분 간격으로 2시간 동안 얻어졌다. 운반체 매개변수 $k_3/k_4$는 동적 IPT SPECT 데이터를 이용 혈액 표본이 사용되지 않는 Ichise의 그래픽분석방법($R_v$)과 Lassen의 면적비율방법($R_A$)를 이용하여 얻어졌다. 운반체 매개변수 $R-v,\;R_A$ 그리고 115분에서 얻은(BG-OCC)/OCC비 사이의 관계들은 선형회귀분석을 사용하였다. 결과 : 정상인과 파킨슨 환자에 대한 $R_v$ 값은 각각 $2.08{\pm}0.29$$0.78{\pm}0.31$이었다. 그리고 $R_A$ 값은 정상인과 파킨슨 환자에 대해 각각 $1.48{\pm}0.16$$0.65{\pm}0.24$이었다. (BG-OCC)/OCC와 $R_v$,(BG-OCC)/OCC와 $R_A$ 그리고 $R_v$$R_A$ 사이의 상관계수들은 각각 0.93, 0.90, 0.99이었고, 그것들에 대응하는 기울기들은 각각 0.54, 0.34, 0.65이었다. 정상인의 $R_v$$R_A$는 파킨슨 환자의 것보다 높았다. 즉, 정상인의 $k_3/k_4$는 파킨슨 환자의 것과 뚜렷이 구분되었다. 그리고 그래픽 분석방법과 면적비율 분석방법에 의한 $k_3/k_4$는 조직방사능비와 좋은 상관관계를 보여주었다. 결론 : 비침습성 단순화된 정량분석 방법들은 매개변수 $k_3/k_4$를 측정하는데 유용할 것이다. 그리고 특이결합비율 분석방법은 [I-123]IPT SPECT를 이용한 사람뇌의 도파민 운반체의 정량분석연구에 대해 유용하게 사용될 것이라고 생각된다.

  • PDF