• Title/Summary/Keyword: duty efficiency

Search Result 448, Processing Time 0.027 seconds

Output improvement on human power generator (휴먼파워 제너레이터에 관한 출력 개선)

  • Han, Seok-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2016.11a
    • /
    • pp.204-205
    • /
    • 2016
  • Human power is not dependent on other energy sources, but rather is a source of power for ourselves. Human power, the cleanest energy in the world, can be our future. Therefore, we should be interested in sustainable alternative energy. This paper solves the uneven power generation by utilizing the energy storage capability of the flywheel. Therefore, it improved the efficiency by 5% compared to the existing generation method. DC generators produce power at variable speed operation. The constant voltage was generated from the DC-DC converter to the duty ratio control. Therefore, the charging efficiency is improved by 5% by the constant voltage charging of the battery. And it can suppress the decrease of the output due to the circulation current due to the deviation of the output voltage in parallel operation of the pedal generator.

  • PDF

A Study on the Duty of the Business Owner in the Contents(Casino) Corporation related with the Commercial Law - In the case of claim for damages of the gambler against the Kangwon Land(Supreme Ct. 2014.8.21, 2010다92438 case) (상법상 유기장콘텐츠 영업주(카지노영업주)의 주의의무에 관한 연구 -강원랜드 카지노 이용자의 손해배상청구의 경우 (대판 2014.8.21., 2010다92438 전원합의체 판결))

  • Chun, Woo-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.12
    • /
    • pp.180-190
    • /
    • 2017
  • This is Kangwon Land casino case due to the damages of betting money, which is likely to affect the contents industry in the future. The reason why the gambler and his family's suit is that why the manager did not control their own access or did not supervise the wagering rules. The provisions of the "Restriction on the amount of money to be paid to the casino" in the Article 14 of the Enforcement Decree of the Act on the Support for the Development of the Abandoned Mine Area are not intended to increase the duty of the casino managers. It is just one of many public regulations imposed. No matter what legislation is made for public interest, it can not be considered equally in the private duty. If so, too much effort will be required to enact or amend the public law and this makes the legislative activity impossible. The Act on the Restriction on Access to the Casino shall be construed accordingly. From the point of view of economic efficiency theory, if we overestimate statutory duties (liability for compensation) excessively, the price goes up on the market, and the volume of transaction decreases drastically. This reduces the economic utility of resources in the society as a whole (total output, foreign currency acquisition amount, etc.).

A Study on the Site Acceptance Test(SAT) Evaluation Algorithm of Energy Storage System using Li-ion Battery (리튬이온전지를 이용한 전기저장장치의 SAT용 성능평가 알고리즘에 관한 연구)

  • Park, Jea-Bum;Kim, Byung-Ki;Kim, Mi-Sung;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.26-37
    • /
    • 2019
  • Recently, standardization of installation progress and technology of site acceptance test(SAT) for energy storage system(ESS) are being required due to performance of ESS depending on working condition and environment even though the quality and safety of each component of ESS is guaranteed. And also, it has been required to perform not only performance testing by H/W equipments but also performance verification by S/W tool, in order to more accurately and reliably validate the performance of the ESS in advanced countries. Therefore, this paper proposes evaluation algorithm for SAT to evaluate performance of ESS and presents modeling of SAT test equipment for ESS by using PSCAD/EMTDC. Furthermore, 30[kW] scaled portable test equipments is implemented based on the proposed algorithm and modeling. From the various simulation and test results, it is confirmed that performance of ESS related to characteristics of capacity and Round-trip efficiency, Duty-cycle efficiency, low voltage ride through(LVRT) and Anti-islanding can be accurately evaluated and that the simulation results of PSCAD/EMTDC are identical to test results of 30[kW] test equipment.

Fabrication and Characterization of Wavelength Conversion Device with Periodically Poled Ridge-type Waveguide in MgO:LiNbO3 (주기적으로 분극 반전된 MgO:LiNbO3를 이용한 리지형 광도파로 파장가변 소자 제작 및 특성)

  • Lee, H.M.;Yang, W.S.;Kim, W.K.;Lee, H.Y.;Jeong, W.J.;Kwon, S.W.;Koo, K.H.;Song, M.G.
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.3
    • /
    • pp.199-207
    • /
    • 2008
  • Wavelength converting devices with a ridge-type waveguide in periodically poled $MgO:LiNbO_3$ are made and characterized. The experimental results are compared with theoretical analysis on the effects of waveguide dimension and duty ratio of the periodically poled structure. To show the relationship of the conversion efficiency to those factors, a new measurement system is configured. That experimental results show that the center wavelength, normalized conversion efficiency and full width half maximum of the conversion efficiency curve are 1067.45 nm, 90.7%/$Wcm^2$ and 0.17 nm, respectively. Also, the estimated results of the duty period and full width half maximum of the conversion efficiency from theoretical calculations agreed well with experimental results with the errors of 0.016 ${\mu}m$ and 0.01 nm.

Comparison on Nano-particle Number Measurement Characteristics for Different Particle Generators between Spray type and Soot Type (Spray type과 Soot type 입자발생기별 나노입자 개수농도분포 측정특성 비교)

  • Kim, M.S.;Kwon, J.W.;Chung, M.C.;Lee, J.W.
    • Journal of ILASS-Korea
    • /
    • v.17 no.4
    • /
    • pp.185-191
    • /
    • 2012
  • Particulate matters (PM) that is generated by most diesel engine is regulated by the mass concentration measured by the conventional method it had been. Recently, Europe PMP (Particle Measurement Program) decided to start the regulation of vehicle's nano-sized particle number (PN) from the year of 2011 because of nano-particle's higher degree of harm to the human body. So firstly, the standard level of PN emission is introduced in the Euro 5/6 emissions regulation with a limit of $6{\times}10^{11}$ per km for light duty vehicle. Also KPMP(Korea Particle Measurement Program) was organized to copy quickly international technical trend. In this paper, it was investigated the nano-sized PN measurement characteristics for different particle generators between spray type and soot type. And the difference ratio between particle generators, the characteristic of PN concentration, counting efficiency and linearity was analyzed. Then, we make conclusions as followed. When particle diameter is increased, counting efficiency of two generators is decreased. Also Secondary calibration method is more higher 3% than Primary calibration method. Finally, SOF which is included in soot particles is not totally removed so it have great influence on test result of counting efficiency and linearity.

A Feasibility Study on Adopting Sliding Pressure Operation for Drum Type Boiler

  • Baek, SeHyun;Kim, HyunHee;Park, SangBin;Kim, YoungJoo;Park, Hoyoung
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.3
    • /
    • pp.403-407
    • /
    • 2016
  • In general, drum-type boilers are designed for base load duty and applied under constant pressure operation mode. Recently, however conditions often occur that even drum-type boilers have to operate at partial load conditions. A feasibility study on adopting the sliding pressure operation for drum-type boiler was conducted, and corresponding performance changes and effects on the equipment were analyzed by utilizing a process simulation model. As a result, the conclusion was reached that drum type boilers are able to adopt the sliding pressure operation and can improve of net efficiency at part load operation in spite of the Rankine cycle efficiency reduction due to the decreases in main steam pressure. Because of thank to improvement of high pressure turbine stage-1 internal efficiency and power savings of boiler feed water pump. The sliding pressure operation is advantageous in terms of stress level relief for boiler tube as well as maintaining the rating steam temperature at part load condition. However, cautions are required because the drum boilers have poor dynamic response characteristics which may get worse during the sliding pressure operation.

High Power Buck-boost DC-DC Converter of Soft Switching for Photovoltaic Power Generation (태양광 발전을 위한 대용량 소프트 스위칭 승강압 DC-DC 컨버터)

  • 김영철;김재준;이종근;전중함;곽동걸;이현우
    • Proceedings of the KIPE Conference
    • /
    • 1996.06a
    • /
    • pp.117-120
    • /
    • 1996
  • Power conversion system must be increased switching frequency in order to achieve a small size, a light weight and a low noise. However, the switches of converter are subjected to high switching power losses and switching stresses. As a result of those, the power system brings on a low efficiency. In this paper, the authors propose a DC-DC boost converter of high power by partial resonant switch method (PRSM). The switching devices in a proposed circuit are operated with soft switching and the control technique of those is simplified for switch to drive in constant duty cycle. The partial resonant circuit makes use of a inductor using step up and a condenser of loss-less snubber. Also the circuit has a merit which is taken to increase of efficiency, as it makes to a regeneration at input source of accumulated energy in snubber condenser without loss of snubber in conventional circuit. The result is that the switching loss is very low and the efficiency of system is high. The proposed converter is deemed the most suitable for high power applications where the power switching devices are used.

  • PDF

A High-Efficiency High-Power Step-Up Converter with Low Ripple Content

  • Kang Jeong-il;Roh Chung-Wook;Moon Gun-Woo;Youn Myung-Joong
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.708-712
    • /
    • 2001
  • A new phase-shifted parallel-input/series-output (PI SO) dual inductor-fed push-pull converter for high-power step­up applications is proposed. This converter is operated at a constant duty cycle and employs an auxiliary circuit to control the output voltage with a phase-shift between the two modules. It features a voltage conversion characteristic which is linear to changes in the control input, and high step-up ratio with a greatly reduced switch turn-off stress resulting in a significant increase in the converter efficiency. It also shows a low ripple content and low root-mean-square (RMS) current in the output capacitor. The operational principle is analyzed and a comparative analysis with the conventional pulse-width-modulated (PWM) PISO dual inductor-fed push-pull converter is presented. A 50kHz, 800W, 350Vdc prototype with an input of 20-32Vdc has also been constructed to validate the proposed converter. The proposed converter compares favorably with the conventional counterpart and is considered well suited to high-power step-up applications.

  • PDF

A Study on the Design Criteria of Photobioreactor for the Efficiency of Light-Utilization (빛 이용효율 향상을 위한 광생물반응기 설계 기준에 관한 연구)

  • 류현진;이진석;오경근
    • KSBB Journal
    • /
    • v.19 no.4
    • /
    • pp.257-262
    • /
    • 2004
  • Recently, there is a growing interest in microalgae and the use of microalgae focused on the production of various high value metabolite used in food, pharmaceuticals and cosmetics. The key limiting factor in high density algal cultivation is the light and algal growth is defined by light intensity and light penetration depth into the culture medium. The effect of light with various light paths, S/V ratios, light intensities, and 50% duty cycle on the growth of microalgae was examined to enhance microalgal biomass productivity and photosynthetic efficiency. We confirmed that the utilization of efficient light energy was obtained from 4 cm of diameter, 57.6% of S/V ratio, 62 ${\mu}$mol/㎡/s of light intensity.

High Efficiency and Low Device Stress Voltage and Current Clamping ZVS PWM Asymmetrical Half Bridge Converter

  • Han Sang Kyoo;Moon Gun-Woo;Youn Myung Joong
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.341-345
    • /
    • 2004
  • A high efficiency and low device stress voltage and current clamping BVS PWM asymmetrical half bridge converter is proposed in this paper. To achieve the ZVS of power switches along the wide load range, the transformer leakage inductor $L_{Ikg}$ is increased. Then, to solve the problem related to ringing in the secondary rectifier caused by the resonance between $L_{Ikg}$ and rectifier junction capacitors, the proposed converter employs a voltage and current clamping cell, which helps voltages and currents of rectifier diodes to be clamped at the output voltage and output current, respectively. Therefore, no RC-snubber for rectifier diodes is needed and a high efficiency as well as low noise output voltage can be realized. In addition, since all energy stored in $L_{Ikg}$ is transferred to the output side, the circulating energy problem can be effectively solved and duty loss does net exist. The operational principle, theoretical analysis, and design considerations are presented. To confirm the operation, validity, and features of the proposed circuit, experimental results from a 425W, 385-170Vdc prototype are presented.

  • PDF