• Title/Summary/Keyword: dust pollution

Search Result 512, Processing Time 0.031 seconds

Study on Wet Electric Precipitation with Electrospray for Removal of PM1.0 in Exhaust Gas (배가스 내 PM1.0 미세먼지 제거를 위한 정전분무 습식 전기집진기에 대한 연구)

  • Cho, Yeonjoo;Lim, Hyunjeong;Kim, Soyeon;Choi, Sangmi;Jeong, Min Kyu;Kim, Minsung
    • Plant Journal
    • /
    • v.16 no.1
    • /
    • pp.34-37
    • /
    • 2020
  • The need to improve the performance of the dust collector by increasing the fine dust pollution in Korea is eminent. In this study, electrostatic spray wet electrostatic precipitator is used to remove Particulate Matter (PM). In order to enter the Cone-jet mode, which is the most stable spray mode among the various modes of electrostatic spraying, an appropriate voltage-flow condition must be satisfied, and a voltage-flow interval enabling this can be expressed as Stability Island. The voltage at which the conduit mode starts in the Stability Island section is referred to as the electrostatic spray minimum voltage (Onset Voltage). However, the conventional electrostatic spray is uses a very low flowrate, at most few millilitres per minute. The use of much higher flowrates has introduced different patterns of electrospray modes. In this study, the different spray modes will be studied in detail.

Effects of Korean Medicine Respiratory Management Program in Public Health Center (보건소 한의약 호흡기관리 프로그램의 효과)

  • Jang, Soobin;Lee, Ju Eun;Kim, Kyeong Han;Park, Sunju;Jang, Bo-Hyoung;Shin, Yong-Cheol;Ko, Seong-Gyu
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.20 no.2
    • /
    • pp.69-75
    • /
    • 2016
  • Objectives : The aim of this study is to introduce the Korean medicine respiratory management program in public health center and to analyze the effects of that program. Methods : The respiratory management program was targeted on 22 soldiers during March 2016. The interventions of this program were herbal medicines (Gilgyung-tang and so on), aromatherapy, peppermint tea, fine dust mask, and health education. Data were collected by retrospective reviewing medical chart and analyzed using SPSS 18.0. Results : Total symptoms scores were measured by 4-point likert scale. Total score was $5.50{\pm}4.848$ at 1st week and $3.27{\pm}3.058$ at 4th week (p=0.008). The severity of respiratory discomfort reduced by $-1.14{\pm}2.46$ compared with last year. The satisfaction score was $7.82{\pm}4.16$. The most hoping program was muscular skeletal disease management program. Conclusions : This study suggests that Korean medical world should prepare countermeasures to cope with diseases caused by air pollution.

Economical Ventilation Effectiveness to Reduce Hazardous Chemical Emissions for a Nail-Salon Worker

  • KWON, Woo-Taeg;JUNG, Min-Jae;LEE, Woo-Sik;KWON, Lee-Seung;SO, Young-Jin
    • Journal of Distribution Science
    • /
    • v.17 no.7
    • /
    • pp.65-76
    • /
    • 2019
  • Purpose - The purpose of this study is to investigate economical ventilation effectiveness to reduce hazardous materials exposure and damage of workers by analyzing exposure amount of noxious substances under various ventilation conditions of nail salon for indoor environments. Research design, data, and methodology - This study was carried out with cooperation of Nail shop located in SeongNam city to involve an analysis of the environmental impact indoor air quality, pollutant exposure and economical cost-effectiveness in the nail workplace. The hazardous substances were PM-10(Particulate Matter-10㎛), VOCs(Volatile Organic Compounds) and Formaldehyde, which are the major materials of nail workplace. Results - PM-10 is reduced by about 60% with air cleaner, forced artificial ventilation by 32%, and natural ventilation by about 12%. TVOCs and Formaldehyde showed similar efficiency (80~100%) after natural ventilation and ventilation after 60 minutes. The removal efficiencies of VOCs and formaldehyde were similar to those of natural ventilation and mechanical ventilation system. However, in case of dust, natural ventilation was reduced by artificial ventilation system due to inflow of external dust during natural ventilation. Conclusions - If the pollution degree of outdoor air is not high, air volume is high, and natural ventilation is performed when the air conditioning and heating system is not operated. Even at the end of the work, it keeps operating for 60 minutes to remove the pollutants generated. Results of this analysis demonstrated that the worker environment can be improved by adopting institutional legislation and guidelines for ventilation.

A Study for Development the Air Cleaner Using Air Ionizing Phenomena and Optical Catalizer (공기전리 현상과 광촉매를 이용한 공기정화 장치 개발에 관한 연구)

  • Shim, Chung-Han;Lee, Won-Dae;Lee, Dong-Hoon;Jung, Yong-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.5 s.77
    • /
    • pp.28-33
    • /
    • 2006
  • The rapidly advanced industrial society takes advantage of high-technology, but it also suffered from the side effects such as various diseases by contamination. Of these problems, air pollution is considered as the most important problem nowadays. Air contamination is not only limited outdoors, but it also causes more serious effect in our indoor air environment. Depending on the notion that indoor air effects physical health seriously, the needs of the air cleaner is more earnest. Therefore, the main purpose of this study is to develop the air cleaner to meet the standard and get rid of poisonous and harmful material from the atmosphere by using a Corona Discharge. According to the purpose of this study, We set the negative ion generator, the UV, $TiO_{2}$ optical catalyzer, the electrical dust collector and the air filter in series order. It emits a lot of negative ions. We use these ions to purify harmful factors and contaminated materials. We collect the dust using static power that comes from the discharge of corona. At the same time, we try to develop the air cleaner to keep the air quality to meet the standard and kill the various viruses using UV LED and $TiO_{2}$ optical catalyzer. In this study, we use the UV LED that is smaller and efficient than a existing UV lamp. What is more, the UV LED has a features that a stabilizer occupying much space is not needed any more.

Analysis of Korean Medical status of Acute Bronchitis, Chronic Bronchitis and Allergic Rhinitis patients (급·만성 기관지염과 알레르기성 비염의 국내 의료 이용 현황 분석)

  • Jung, You Jin;Yang, Woong Mo
    • The Journal of Korean Medicine
    • /
    • v.40 no.3
    • /
    • pp.87-98
    • /
    • 2019
  • Objectives: Patients with respiratory diseases are increasing as air pollution due to fine dust gets worse. Diseases that occupy a large proportion of respiratory diseases in medical institutions are acute bronchitis, chronic bronchitis and Allergic rhinitis. The number of patients with all three diseases is gradually increasing. This study was to suggest assignment of medicine policy for improving accessibility to Korean medical treatment of respiratory diseases analyzing the current treatment status of acute bronchitis, Chronic bronchitis and Allergic rhinitis patients in Western medical and Korean medical institutes in this situation. Methods: This study used 2017 National patient sample data from the Korean Health Insurance Review and Assessment Service for research. Acute bronchitis, Chronic bronchitis, Allergic rhinitis was according to KCD code. This research contains Socio-demographic analysis classified by sex and age, the number of three disease's patients. Also the number of medical treatment, the expense of recuperation cost, medical practices were analyzed compare with Western and Korean medicine. Results: The incidence of three diseases is higher among female than male. There are many patients under the age of 10 in the case of acute bronchitis and allergic rhinitis, while there are many patients over 50 years of age in chronic bronchitis. Western medical treatment take up a larger proportion than Korean medical treatment in part of the number of three disease's patients, the number of medical treatment, the expense of recuperation cost. Conclusions: Much more patients of these diseases visit in Western medical clinic and hospital than Korean medical clinic and hospital for treatment. There are many parts of Korean medical treatment that are not covered by Health insurance benefits like herbal decoction, pharmacopuncture, etc. Korean medicine need to do the efforts for expanding medical field in variety. Also it is demanded for institutional support for reduction of the cost burden and improving on accessibility of Korean medical treatment in order to treat with the increase in respiratory diseases due to fine dust.

Properties of Cement Matrix using Carbon Black (카본블랙을 혼입한 시멘트 경화체의 특성)

  • Lee, Jeon-Ho;Lee, Chang-Woo;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.217-218
    • /
    • 2021
  • With the prolonged Covid-19 epidemic, movement restrictions such as social distancing are prolonged, and as people stay indoors for a longer time, interest in indoor air pollution is increasing. Indoor air quality is not easily purified unlike outdoors. Among indoor building materials, paints and flooring contain formaldehyde that causes sick house syndrome and VOCs that contain carcinogenicity and harmfulness. For modern people who spend a lot of time living indoors for more than an hour, the occurrence of these harmful substances can be said to be fatal. In response to these risks, in July 2019, the government reinforced the standards for indoor air quality to protect the public's health by raising the detection standards for fine dust, ultrafine dust, and formaldehyde in indoor multi-use facilities. People use machines such as air purifiers to improve indoor air quality, or make efforts such as periodic ventilation. In order to reduce or support these other ancillary efforts more effectively, to reduce the generation of pollutants in the building itself, or to adsorb or purify pollutants in the air, use carbon black as an admixture to make a cement hardened body, and to grasp basic physical properties and adsorption capacity. And the result is as follows. As a result of the experiment to determine the appropriate amount of carbon black, it was confirmed that the more the amount of carbon black was added, the better it was in the formaldehyde emission test, but the tendency was not clear when measuring the flexural strength, so a further experiment to improve this is needed.

  • PDF

A Geochemical Study on the Dispersion of Heavy Metal Elements in Dusts and Soils in Urban and Industrial Environments (도시 및 산업환경 분진 및 토양중의 중금속 원소들의 분산에 관한 지구화학적 연구)

  • Chon, Hyo-Taek;Choi, Wan-Joo
    • Economic and Environmental Geology
    • /
    • v.25 no.3
    • /
    • pp.317-336
    • /
    • 1992
  • The garden soils, main road dusts, residential road dusts, and playground soils/dusts of Seoul, Geumsan, Onsan, and Taebaek areas were analyzed in order to investigate the level of heavy metal pollution by urbanization and industrialization. The soil pH is in the range of 5.48~8.40 and was generally neutral. The color of soils and dusts is mainly Raw Umber to dark greyish Raw Umber. Some samples from Taebaek city, a coal mining area, showed a deep black color due to contamination by coal dusts. Major minerals of the dusts and soils are quartz, feldspars, and micas, reflecting the composition of the parent rocks. However, pyrite was found as a major mineral in the samples of industrial road dusts of Onsan, a smelting area, and resicential road dusts of Taebaek. Thus, the high level of heavy metals in mining and smelting areas can be explained with the sulfide minerals. The mode of occurences of heavy metals in Seoul, a comprehensive urbanized area, were related to the metallic pollutants and organic materials through observation by scanning eletron microscopy. In main road and residential road dusts of Onsan area, Cd, Zn, and Cu were extremely high. Some industrial road and residential road dusts of Seoul area showed high Cu, Zn, and Pb contents, wereas some garden soils and residential road dusts of Taebaek area were high in As content. In general, the heavy metal contents in dust samples were two to three times higher than those in soil samples. Main road dust samples were the most reflective from the discriminant analysis of multi-element data. Cadmium, Sb, and Se in Onsan area, As in Taebaek area, Pb and Te in Seoul area were most characteristic in discriminating the studied areas. Therefore, Cd in smelting areas, As in coal mining areas, and Pb in metropolitan areas can be suggested as the characteristic elements of each pollution pattern. The dispersion of heavy metal elements in urban areas tends to orignate in main roads and deposit in garden soils through the atmosphere and residential roads. The heavy metal contamination in Seoul is characteristic in areas with high population, factory, road, and traffic decsities. Heavy metal contents are high in the vicinity of smelters in Onsan area and are decayed to background levels from one kilometer away from the smelters.

  • PDF

Application of Oryza sativa (Rice) Bran Oil as an Anti-pollution Cosmetic Material (쌀겨오일의 안티폴루션 화장품 소재로써의 응용)

  • Kang, Hae-Ran;Jung, So Young;Heo, Hyojin;Cha, Byungsun;Brito, Sofia;Lee, So Min;Yeo, Hye Lim;Yoo, Kyung Wan;Kwak, Jun Soo;Kwak, Byeong-Mun;Lee, Mi-Gi;Bin, Bum-Ho
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.47 no.3
    • /
    • pp.237-245
    • /
    • 2021
  • Particulate matter and ultra-particle matters generally refer to very small floating dust, such as 1/6 to 1/7 and 1/20 to 1/30, respectively, compared to the thickness of human hair, and contain various types of heavy metal ions. In addition to breathing, particle matters (PM) that flows in through the gaps in the pores of the skin can induce health problems in the body's tissues and skin, so it must be removed by blocking the inflow or by washing. Through this study, we confirmed the possibility that heavy metal ions can be adsorbed and removed by using Oryza sativa (Rice) bran oil (OSBO). In addition, the cell viability is much higher than that of grain-derived components through cytotoxicity experiments, and the cytoprotective effect of an external stimulus source can be expected. It was confirmed that the expression amount of COL1A1 mRNA increased, and accordingly, it was believed that wrinkles that might be caused by moisture lost by heavy metal ions in fine dust could be alleviated. Based on the results of these experiments, we tried to present a cosmetics containing OSBO, which is a wash-off formulation, in order to finally remove heavy metals.

Changes in Light Transmittance of Greenhouse Covering Materials and Cucumber Growth as Affected by Particulate Matter (미세먼지 발생에 의한 온실 피복재의 광투과율 감소 및 오이 생육 변화)

  • Inseo Hong;Yoomin Ha;Yurina Kwack
    • Journal of Bio-Environment Control
    • /
    • v.32 no.4
    • /
    • pp.312-318
    • /
    • 2023
  • In recent years, fine and yellow dust pollution has become serious in Korea and has negatively affected crop production. Particulate matter (PM) adheres to greenhouse coverings, and it reduces the amount of solar radiation transmitted into a greenhouse. A reduction in light transmittance can have a direct effect on crop photosynthesis and an indirect effect on air temperature in a greenhouse, which can lead to differences in crop yield. The objectives of this study were to investigate the changes in light transmittance of different cover materials by PM and to determine the changes in cucumber growth in a greenhouse due to reduced light transmittance. We measured the changes in light transmittance of polyethylene (PE) and polyolefin (PO) films in the PM generation chambers. Also, cucumber plants were cultivated in a greenhouse with four different light reduction treatments (0, 10, 20, and 30% reduction of light transmittance). The initial light transmittance of PO film was higher than that of PE film and the decrease in light transmittance of PO film due to PM was less than that of PE film. The vegetative growth of cucumber was promoted under the reduced light transmittance treatments; however, the yield of cucumber was highest in the control (0% reduction of light transmittance). From the results, we confirmed that PO film was less PM adhesion and that cucumber yield during the spring season can be reduced by the reduction in light transmittance due to PM.

Comparison of air pollution and the prevalence of allergy-related diseases in Incheon and Jeju City

  • Jeong, Su-Ho;Kim, Jeong-Hee;Son, Byong-Kwan;Hong, Seong-Chul;Kim, Su-Young;Lee, Geun-Hwa;Lim, Dae-Hyun
    • Clinical and Experimental Pediatrics
    • /
    • v.54 no.12
    • /
    • pp.501-506
    • /
    • 2011
  • Purpose: A high level of air pollutants can increase the number of patients with allergy-related diseases such as asthma and allergic rhinitis (AR). To analyze the association between air pollution and allergic disease, we investigated 2 areas in Korea: Incheon, an industrial area, and Jeju, a non-industrialized area. Methods: Second grade students at elementary schools (11 schools in Incheon and 45 schools in Jeju) were examined in a cross-sectional study. A questionnaire was used and a skin prick test was performed. The levels of $NO_2$, $CO_2$, $O_3$, particulate matter (PM) $PM_{10/2.5}$, formaldehyde, tVOCs, and dust mites in the classrooms and grounds were determined. Results: The levels of outdoor CO, $PM_{10}$, and $PM_{2.5}$ were significantly higher in Incheon (P<0.01). The levels of indoor CO, $CO_2$, $PM_{10}$, $PM_{2.5}$ were significantly higher in Incheon (P<0.01). The prevalence rates of AR symptoms at any time, AR symptoms during the last 12 months, diagnosis of rhinitis at any time, and AR treatment during the last 12 months were significantly higher in Incheon (P<0.01). The prevalence rate of wheezing or whistling at any time, and wheezing during the last 12 months were significantly higher in Incheon (P<0.01). Conclusion: We found that the children living in Incheon, which was more polluted than Jeju, had a higher rate of AR and asthma symptoms compared to children in Jeju. To determine the effect of air pollution on the development of the AR and asthma, further studies are needed.