• Title/Summary/Keyword: dust collector

Search Result 101, Processing Time 0.025 seconds

How to Evaluate the Combined Dust Removal Efficiency of Fine Dust in the Dust Collector (집진기 미세먼지의 복합제진효율 평가방법)

  • Kang, Il-Seo;Lee, Young-su;Kim, Dong-Hyun
    • Journal of Digital Convergence
    • /
    • v.20 no.2
    • /
    • pp.339-344
    • /
    • 2022
  • It is about how much fine dust can be efficiently removed with respect to the electric dust collector used in factories and large facilities. The results of evaluating the fine dust removal efficiency are as follows. At 10,000 V, Efficiency method I showed 68.1 %, and Efficiency method II was 58.6 %, which was lower than that of Efficiency method I. At 5,000 V, Efficiency method I showed 57.6%, and Efficiency method II showed 51.6%, which was lower than Efficiency method I. At 2,500 V, Efficiency method I showed 50.3%, and Efficiency method II showed 24.4%, which was lower than Efficiency method I. In case of Efficiency method I, it is the efficiency calculated by using the dust concentration before and after passing through the filter. Efficiency method II calculated Efficiency method II to measure the efficiency a little more accurately in the environment where the air after the filter and the polluted air are mixed. Efficiency method II showed lower efficiency than Efficiency method I. As a result of the electrostatic precipitator test, the dust collecting performance was highest at 10,000 V, followed by 5,000 V and 2,500 V in that order.

A Hybrid Dust Collector(Hi-Filter) for Reducing Dust Load (먼지부하 저감형 하이브리드 여과집진장치(Hi-filter))

  • 최호경;박석주;임정환;김상도;박현설;박영옥
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2002.05a
    • /
    • pp.223-226
    • /
    • 2002
  • 본 연구에서는 전기집진 기술과 여과집진 기술의 조합에 의한 먼지입자의 포집성능 상승효과를 최대한 높일 수 있는 먼지부하 저감형 하이브리드 집진장치(Hi-Filter)를 개발하기 위해 실험실 규모의 장치를 이용한 실험을 통하여 장치의 최적 형상을 결정하고 그 성능을 검증하였다.(중략)

  • PDF

Deflective Behavior of Charged Particles in a Two-Stage Electrostatic Precipitator

  • Lim, Hun-Chan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.7
    • /
    • pp.83-91
    • /
    • 2011
  • Even if smoke, fumes, mist or dust particles are removed by electrostatic precipitators (ESPs), the occurrence of ozone, which is harmful to human body, has to be severely restricted in the indoor environments of hospitals, offices, and workshops. Therefore, the two-stage ESP generating positive corona at the ionizer is typically used because it creates less ozone than the two-stage ESP generating negative corona at the ionizer. In order to predict the collection performance and the optimal design of the two-stage ESP applied to positive high-voltage, particle concentration is experimentally investigated in this paper. In addition, particle motion within the collector section is also numerically analyzed. The positive corona discharge current of the ionizer is found to be affected by the applied voltage in the collector section but less so by the particle concentration. Particle concentration shows a minimum near the high voltage electrode of the collector section. The minimum value of the collection efficiency is almost proportional to gas velocity. When the collector length decreases, the minimum value of the collection efficiency increases. Charged particles entering the collector region are linearly deflected towards the grounded plate by an electric field. From the above experimental and numerical results, two empirical equations on the concentration ratio and the collection efficiency are derived, and are in good agreement with the experimental data.

Fundamental Design of Cyclone Collector for Oil Mist (오일미스트용 사이클론 집진기에 관한 기초 설계 -오일미스트 및 슬러지 입자 융합연구-)

  • Jang, Sung-Cheol;Ahn, Hwi-Woong;Lee, Chan-Kyu
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.2
    • /
    • pp.223-227
    • /
    • 2013
  • Dust collecting performance of cyclone collector for oil mist was alalyzed in the study. The purposes of using cutting fluid during cutting have been colling, lubricating, chip washing and anti-corroding. However, the present manufactaring industry restricts the use of cutting fluid because cutting fluid confains poisonous substances which are harmful to the human body. Also, the optimum design oil-mist collector. The new oil mist collector was designed. In the near future, this device must be tested in the real machining center and CNC machine. Cutting using oil-mist showed better cutting characteristics than dry, air and fluid cutting with respect to by cutting force, tool wear and surface roughness. The model(A, B Type cyclone) of the set of fixture and alveolus are made by using a CAE software. Finally, we have obtained a model A Type solution by using orthogonal array. Therefore, it could be confirmed that as the model-A was increased and model-B was decreased, cut diameter was decreased.

Aanalyze the Fluid Inside the Ceramic Filtration Dust Collection System (세라믹 필터 집진기의 유동 해석)

  • Jang, Sung-Cheol;Choi, Dong-Soon
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.20 no.1
    • /
    • pp.67-73
    • /
    • 2017
  • This study aimed to analyze the fluid inside the ceramic filtration dust collection system which was assumed to be a stationary 3-dimensional turbulence. The fluid dynamics data necessary for performance curves were obtained based on the analysis results. The governing equations used to compute the velocity distribution and pressure inside the catalyst converter were expressed with continuity and momentum equations. Furthermore, the ${\kappa}-{\varepsilon}$ turbulence model, already validated by the industry(coal factory, high temperature dust collector) was used for the study. Of a total of three computational models employed, Model-1 served as the basis for CFD analysis which took measurements in increments of 70mm.

Performance Test of Ceramic Filter Collector for the heavy-oil boiler for Concurrent treatment Dust and Nitrogen Oxides (분진 및 질소산화물 동시처리를 위한 1톤 중유 보일러용 세라믹 필터 집진기의 성능실험)

  • Jung, Wan-Bo;Cho, Jung-Sick
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.21 no.6
    • /
    • pp.355-360
    • /
    • 2018
  • The product developed in this study is a ceramic catalyst filter for 1 ton heavy-oil boiler that can simultaneously process dust and nitrogen oxides. This has been developed for simultaneous processing of nitrogen oxides and dust at high efficiency of hot exhaust gas (approximately $300^{\circ}C$) generated after burning 1 ton heavy oil boiler. Ceramic catalytic filters for 1 tonne heavy-duty glass display are technologies that remove 90% of dust and 85% or more of nitrogen oxides. This is an improved new technology to integrate exhaust ventilation and desiccation devices into one, thereby reducing the production process and improving the economy. To this end, the performance test of the catalytic filter for heavy oil boilers was carried out, and the durability of the PLC circuit was constructed.

System Development of Removing Dust and Odor from Manufacturing Process of FRP Products (FRP제품 가공시 발생하는 분진 및 악취 제거 시스템 개발)

  • Yun, Huy Kwan;Kim, Jae Yong
    • Applied Chemistry for Engineering
    • /
    • v.20 no.5
    • /
    • pp.547-552
    • /
    • 2009
  • When fiber reinforced plastics (FRP) products are manufactured, dust and odor materials are inevitably generated in a workplace. To improve the bad condition of the workshop, we developed the Hybrid Bag Filter attached activated carbon fiber (ACF) and installed the system at two companies producing FRP goods. In order to raise the efficiency of dust collection, we set the ducts both on the ceiling and at the bottom of the wall and according to the circumstances of the workshop's space, moving dust collector also adopted as a different type of flexible duct. Pulse Jet Type Bag Filter is also equipped to operate the system more effectively, for the improved fine environment because of high dust removal efficiency. Finally, we investigated the removal tendency of the dust and odor when operating the System of Hybrid Bag Filter.

A Study on the Effect of Dust Precharging on Filtration Performance

  • Park, Y.O;Park, S.J.;Lee, J.H.;Kim, S.D.;Park, H.S.;Park, H.K.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.E2
    • /
    • pp.53-59
    • /
    • 2001
  • A hybrid dust-collector combining electrostatic charging with fabric filtration method was developed, and its performance characteristics were evaluated in this study. Charged particles build porous dendritic structure on the surfaces of filter by electrostatic attraction, increasing the collection efficiency of dust particles and reducing the pressure drop through the deposited dust layer and filter media. The cleaning performance of the dust layer is improved because the dendritic structured dust layer can be removed more easily by pulse jet cleaning flow. The results of the experiment showed a reduction of fine particle emission of 37% and the energy saving of 13% by precharging dust particles before filtration.

  • PDF

Optimal Design of Vacuum Cleaner with a Multi Cyclone (멀티사이클론을 이용한 진공청소기의 최적설계에 관한 연구)

  • Ha, Gun-Ho;Kim, Eung-Dal;Yang, Byung-Sun;Ahn, Young-Chull
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.2
    • /
    • pp.126-131
    • /
    • 2011
  • Cyclone, a type of particle collector widely used in the field of ambient sampling and industrial particulate control, is the principal type of gas-solids separator that uses a centrifugal force. The goal of this study is to design and evaluate the cyclone that can be used for the household vacuum cleaners. A multi cyclone with a 1st cyclone and several 2nd cyclones is designed to improve dust collection efficiency. The dust collection efficiency and the suction power of 1st cyclone are evaluated. And the dust collection efficiency and the suction power of multi cyclone are evaluated according to various sizes of inlet and vortex finder. As a result, a cone shape porous filter has better dust collection efficiency than a cylinder shape porous filter. The dust collection efficiency of a multi cyclone is 3.5% greater than that of a single cyclone.