• Title/Summary/Keyword: dust and odor

Search Result 36, Processing Time 0.029 seconds

Public perception of environmental health due to small-scale industries in a rural community (일개 농촌지역 주민의 소규모 공장으로 인한 보건생활환경에 관한 인식도 조사)

  • Kim, Jeong-Youn;Jung, Yun-Jae;Sung, Yu-Mi;Ha, Eun-Hee;Wie, Cha-Hyung
    • Journal of agricultural medicine and community health
    • /
    • v.25 no.1
    • /
    • pp.1-9
    • /
    • 2000
  • A public perception survey of environmental health due to small-scale industries was conducted in Sudong Myun, Namyangju City, Kyungki Do, recently being changed to industrialized rural community. This survey had the purpose to ascertain public interest, to identify public needs, and to assess participation for environmental health programs of rural community. The results of survey were as follows: 1. The rate of the respondents with factory worker 19.4% and half(53.1%) of respondents had lived nearby the factory. 2. Some respondents were not favor their neighboring factories(30.1%) and have discussed about its environmental problems in community meeting(14.4%) especially in neighborhood adjacent factories. 3. The respondents have perceived that: (1) major problems were water contamination, air pollution, nasty odor, dust, and noise (2) health problems were more serious in employees than in other residents (3) the employers were responsible for environmental problems (4) the health service should provided by public health center channel and participated by the residents (5) most important service for workers was improvement of working conditions. We hope the community environmental and/or occupational health delivery system for the employees and residents will be developed true public health center channel in a rural community on the basis of this result.

  • PDF

A Case Study on the Creating Artificial Planting Ground on the Waste Landfill Sites -In Case of the Bank Isolated Section Planting Layer at the Landfills of Satellite Cities of Seoul- (폐기물매립지 인공식재지반 조성 사례연구 -수도권매립지 제방이격구간 식재층을 대상으로-)

  • 조주형;이재근
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.29 no.1
    • /
    • pp.131-139
    • /
    • 2001
  • This paper aims at surveying through case studies the planting possibility on the interval artificial ground between the bank and the core landfill of the first section of works in the SUDOKWON Landfill area landfill area which was completed, followed by the layer-on-layer landfill process involving the latch or sealing layer against emitting landfill gas from the reclaimed waste. The survey results are as follows; 1. The layers of the artificial planting ground on the landfill were established on the basis of top-on-top procedure for a waste layer, a topping soil layer (T=50cm), a gas blocking layer (broken stones T=30cm), a filter layer (non-woven fabric 700g), a sheet protecting soil layer (T=20cm), and a blocking layer (HDPE SHEET 2.0mm), an irrigation layer (SAND T=30cm), a filter layer (non-woven fabric 700g), a sheet protecting soil layer (T=20cm), and a blocking layer (HDPE SHEET 2.0mm), an irrigation layer (SAND T=30cm), a filter layer (non-woven fabric 700g), a planting layer (T=90cm+), a top mound (T=2m). 2. Since no direct damage on the planting layer affected by the landfill gas was detected, planting is found to be still possible and successful except the severely unequal subsidence portion. 3. The mortality rate is discovered different on different trees: Pinus thunbergii (H3.0$\times$W1.0m) 11.25%, Pinus thunbergii (H2.5$\times$W0.8m) 4.73%, Koelreuteira paniculata 8.67%, Hibiscus syriacus 5.68%, Deutzia parviflora 6.50%, Forsythia koreana 8.17%, Rho. yedoense v. poukhanese 32.22%, and Spiraea pru v. symplicifolia 18.89%; although the last two of which are generally considered to have a strong generic growing character, they are subject to be weakened when exposed to the contaminated microclimate of the site like landfill gas. 4. The damage rates, on Pinus thunbergii, Koelreuteria paniculata, Hibiscus syracus, Forsythia koreana, Deutzia parviflora, Rho. yedoense v. poukhanense were shown to decrease to 7.31-17.69% in the second check (June 2000) lower than 5.77-46.92% in the first examination (June 1999), whereas the damage on Spiraea pru v. symplicifolia relatively increased. It is believed that preparatory method of the air pollution, change of temperature, odor by emitting landfill gas, and minute dust from vehicles should be made, and a research on this matter will be conducted in the near future.

  • PDF

A Study on the Consciousness of the Environment Pollution Problem in Pohang City (환경문제에 관한 시민의식 조사 - 통합후 포항시민을 대상으로 -)

  • Ha, Yeong-Gil;Park, Kyung-Min;Kwon, Young-Sook
    • Journal of agricultural medicine and community health
    • /
    • v.21 no.1
    • /
    • pp.61-73
    • /
    • 1996
  • This study conducted to determine the attitude on environment pollution by Pohang city citizens. 1,059 Pohang city citizens in the age group 20 and over were chosen and surveyed by officials's interview at Up, Myun and Dong during the period 6 September to 20 September 1995. The issue problems to be solved in Pohang city were traffic control 47.3%, environment pollution 22.7%, cultural institutions 11.6%, water service 9.9%, education system 5.1% and community security 2.1%. The 55.1% of subjects responded that responsibility for environment pollution is every citizens duty. The trash from houses were 'garbage'(48.1%), 'waste of life'(21.8%), 'reuse trash'(15.6%) and 'one use thing'(14.5%) in order. The 66.9% of subjects responded that the trash's standard envelopes can be easily tear and its texture is not good. The respondents sometimes or often had experienced foreign bodies, sediment in the water service supply. The 45.9% of the respondents use natural water as drinking water, and the water service supply(26.7%), underground water(17.0%) and buying water(9.3%) were followed. Pertaining to the air pollution(by percent) was pollution of the steel industry complex 78.0%, combustive gas 16.6% and construction dust 1.7%. The respondents at southern district complained of respiratory tract by air pollution and the respondents at northern district complained of the visual disturbance and the offensive odor(P<0.05). Water pollution problem is factory's wastewater 56.2%, home wastewater 36.4% and livestock's wastewater 5.6% in order. The respondents at southern district complained of the noise pollution by airplanes and factories at the afternoon and the respondents at northern district complained of the noise pollution by vehicles(P<0.05).

  • PDF

A Study on the Environmental Characteristics of a Two-storey Pig House for the Control of Manure (고상식돈사의 분뇨처리에 관한 연구)

  • Jeong, J.W.;Yoo, Y.H.;Park, K.H.;Kam, D.H.;Lee, M.J.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.3
    • /
    • pp.175-182
    • /
    • 2008
  • This research was conducted to examine proper manure treatment methods for a high-rise swine barn with results of the fact-finding survey on manure treatment methods used in high-rise swine barns and sawdust swine barns In Korea. The average temperatures on bedding of control, T1, and T2 were between $25.3{\sim}25.4^{\circ}C$ with little difference. Air flow rate of T2 was slower than those of control and T1. Dust generation in control was 54 cpm which was higher than T1 and T2. The average ammonia concentration in control was highest showing 6.0 ppm, ranged from 0.5 to 14.5 ppm, with statistical difference (p<0.05), compared to T1 (2.8 ppm) and T2 (2.6 ppm). Sawdust spreading used in control and T1 decreased ammonia concentration. T1 showed the lowest concentration of $CO_2$. Water contents of control and T2 were close to the proper water content, 65%. T1 had the highest water content and pH, and the lowest organic matter and C/N ratio. The volumes of sawdust spread per head were 0.26 and $0.27m^3$ in control and T2, respectively, which was less than T1. Operating cost such as an electricity bill for blowers was cheap in T2. Hence, T2 bedding sawdust up to 10 cm thick and periodically spreading additional sawdust from second story was recommended.

  • PDF

Development of a Pre-treating Equipment and the Carcass Disposal System for Infected Poultry (감염가금 전처리 및 폐사가축 처리시스템 개발)

  • Hong, J.T.;Kim, H.J.;Yu, B.K.;Lee, S.H.;Hyun, C.S.;Ryu, I.S.;Oh, K.Y.;Kim, S.;Kwon, J.H.;Tack, D.S.
    • Journal of Animal Environmental Science
    • /
    • v.17 no.2
    • /
    • pp.81-92
    • /
    • 2011
  • When we bury the infected poultry into the ground, we have many problems such as the difficulty of making sufficient area for burying, environmental contamination by the leachate, unpleasant ordor. Also, in case of burning the carcass of the infected poultry, there are some problems such as high cost, dust, unpleasant odor, etc. It could cause environmental contamination which many peoples and environmental organization complains about. In this study, we develop a treating system which treats the infected poultry carcass in a environmental method preventing the environment contamination. This system is composed of many processes. The euthanasia system uses rigid vinyl to trap and to do a euthanasia the infected poultry with lethal gas, carbon dioxide. And then, with the tractor attached grappler infected poultry carcass could be put into the carcass treating system. The euthanasia system uses rigid vinyl to trap the infected birds and to confine lethal gas, carbon dioxide. Infected poultry carcass are moved to carcass disposal system by collecting device which is attached at tractor. The carcass treatment system (capacity of disposal : 6.3 $m^3$) is installed on a truck and do one pass work, which is input, crush, stir, sterilize, and discharge treated carcass. 1,000 chickens was killed within 9.7min by $CO_2$ (300L/min) in the tent (10 $m^3$). The collecting device could carry 142 chickens at a time, and the movable carcass treatment system could sterilize 2 tons carcass per hour (at one time). This treatment systems was eco-friendly because it reduced the volume of carcass by 31.9% with no wastewater generation.

Air Pollution and Its Effects on E.N.T. Field (대기오염과 이비인후과)

  • 박인용
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1972.03a
    • /
    • pp.6-7
    • /
    • 1972
  • The air pollutants can be classified into the irritant gas and the asphixation gas, and the irritant gas is closely related to the otorhinolaryngological diseases. The common irritant gases are nitrogen oxides, sulfur oxides, hydrogen carbon compounds, and the potent and irritating PAN (peroxy acyl nitrate) which is secondarily liberated from photosynthesis. Those gases adhers to the mucous membrane to result in ulceration and secondary infection due to their potent oxidizing power. 1. Sulfur dioxide gas Sulfur dioxide gas has the typical characteristics of the air pollutants. Because of its high solubility it gets easily absorbed in the respiratory tract, when the symptoms and signs by irritation become manifested initially and later the resistance in the respiratory tract brings central about pulmonary edema and respiratory paralysis of origin. Chronic exposure to the gas leads to rhinitis, pharyngitis, laryngitis, and olfactory or gustatory disturbances. 2. Carbon monoxide Toxicity of carbon monoxide is due to its deprivation of the oxygen carrying capacity of the hemoglobin. The degree of the carbon monoxide intoxication varies according to its concentration and the duration of inhalation. It starts with headache, vertigo, nausea, vomiting and tinnitus, which can progress to respiratory difficulty, muscular laxity, syncope, and coma leading to death. 3. Nitrogen dioxide Nitrogen dioxide causes respiratory disturbances by formation of methemoglobin. In acute poisoning, it can cause pulmonary congestion, pulmonary edema, bronchitis, and pneumonia due to its strong irritation on the eyes and the nose. In chronic poisoning, it causes chronic pulmonary fibrosis and pulmonary edema. 4. Ozone It has offending irritating odor, and causes dryness of na sopharyngolaryngeal mucosa, headache and depressed pulmonary function which may eventually lead to pulmonary congestion or edema. 5. Smog The most outstanding incident of the smog occurred in London from December 5 through 8, 1952, because of which the mortality of the respiratory diseases increased fourfold. The smog was thought to be due to the smoke produced by incomplete combustion and its byproduct the sulfur oxides, and the dust was thought to play the secondary role. In new sense, hazardous is the photochemical smog which is produced by combination of light energy and the hydrocarbons and oxidant in the air. The Yonsei University Institute for Environmental :pollution Research launched a project to determine the relationship between the pollution and the medical, ophthalmological and rhinopharyngological disorders. The students (469) of the "S" Technical School in the most heavily polluted area in Pusan (Uham Dong district) were compared with those (345) of "K" High School in the less polluted area. The investigated group had those with subjective symptoms twice as much as the control group, 22.6% (106) in investigated group and 11.3% (39) in the control group. Among those symptomatic students of the investigated group. There were 29 with respiratory symptoms (29%), 22 with eye symptoms (21%), 50 with stuffy nose and rhinorrhea (47%), and 5 with sore thorat (5%), which revealed that more than half the students (52%) had subjective symptoms of the rhinopharyngological aspects. Physical examination revealed that the investigated group had more number of students with signs than those of the control group by 10%, 180 (38.4%) versus 99 (28.8%). Among the preceding 180 students of the investigated group, there were 8 with eye diseases (44%), 1 with respiratory disease (0.6%), 97 with rhinitis (54%), and 74 with pharyngotonsillitis (41%) which means that 95% of them had rharygoical diseases. The preceding data revealed that the otolaryngological diseases are conspicuously outnumbered in the heavily polluted area, and that there must be very close relationship between the air pollution and the otolaryngological diseases, and the anti-pollution measure is urgently needed.

  • PDF