• 제목/요약/키워드: ductility factors

검색결과 179건 처리시간 0.02초

Analysis of axial compression performance of BFRRAC-filled square steel tubular column

  • Xianggang Zhang;Jixiang Niu;Wenlong Shen;Dapeng Deng;Yajun Huang
    • Steel and Composite Structures
    • /
    • 제49권4호
    • /
    • pp.457-471
    • /
    • 2023
  • To make up for the performance weaknesses of recycled aggregate concrete (RAC), expand the application range of RAC, and alleviate the environmental problems caused by excessive exploitation of natural coarse aggregates (NCA), this study proposes a basalt fiber-reinforced recycled aggregate concrete (BFRRAC)-filled square steel tubular columns that combines two modification methods of steel tube and fiber, which may greatly enhance the mechanical properties of RAC. The axial compression performance for BFRRAC-filled square steel tubular columns was reported during this study. Seven specimens with different replacement ratios of recycled coarse aggregate (RCA), length-diameter ratios, along with basalt fiber (BF) contents were designed as well as fabricated for performing axial compression test. For each specimen, the whole failure process as well as mode of specimen were discovered, subsequently the load-axial displacement curve has obtained, after which the mechanical properties was explained. A finite element analysis model for specimens under axial compression was then established. Subsequently, based on this model, the factors affecting axial compression performance for BFRRAC-filled square steel tubes were extended and analyzed, after which the corresponding design suggestion was proposed. The results show that in the columns with length-diameter ratios of 5 and 8, bulging failure was presented, and the RAC was severely crushed at the bulging area of the specimen. The replacement ratio of RCA as well as BF content little affected specimen's peak load (less than 5%). As the content of BF enhanced from 0 kg/m3 to 4 kg/m3, the dissipation factor and ductility coefficients increased by 10.2% and 5.6%, respectively, with a wide range.

Impact of openings on the structural performance of ferrocement I-Beams under flexural loads

  • Yousry B.I. Shaheen;Ghada M. Hekal;Ayman M. Elshaboury;Ashraf M. Mahmoud
    • Structural Engineering and Mechanics
    • /
    • 제90권4호
    • /
    • pp.371-390
    • /
    • 2024
  • Investigating the impact of openings on the structural behavior of ferrocement I-beams with two distinct types of reinforcing metallic and non-metallic meshes is the primary goal of the current study. Up until failure, eight 250x200x2200 mm reinforced concrete I-beams were tested under flexural loadings. Depending on the kind of meshes used for reinforcement, the beams are split into two series. A control I-beam with no openings and three beams with one, two, and three openings, respectively, are found in each series. The two series are reinforced with three layers of welded steel meshes and two layers of tensar meshes, respectively, in order to maintain a constant reinforcement ratio. Structural parameters of investigated beams, including first crack, ultimate load, deflection, ductility index, energy absorption, strain characteristics, crack pattern, and failure mode were reported. The number of mesh layers, the volume fraction of reinforcement, and the kind of reinforcing materials are the primary factors that vary. This article presents the outcomes of a study that examined the experimental and numerical performance of ferrocement reinforced concrete I-beams with and without openings reinforced with welded steel mesh and tensar mesh separately. Utilizing ANSYS-16.0 software, nonlinear finite element analysis (NLFEA) was applied to illustrate how composite RC I-beams with openings behaved. In addition, a parametric study is conducted to explore the variables that can most significantly impact the mechanical behavior of the proposed model, such as the number of openings. The FE simulations produced an acceptable degree of experimental value estimation, as demonstrated by the obtained experimental and numerical results. It is also noteworthy to demonstrate that the strength gained by specimens without openings reinforced with tensar meshes was, on average, 22% less than that of specimens reinforced with welded steel meshes. For specimens with openings, this value is become on average 10%.

원형 내부 구속 중공 철근콘크리트 기둥의 내화 성능 (Fire Resistance of Circular Internally Confined Hollow Reinforced Concrete Column)

  • 원덕희;한택희;이규세;강영종
    • 한국강구조학회 논문집
    • /
    • 제22권2호
    • /
    • pp.139-150
    • /
    • 2010
  • 기둥은 하중 상태에 따라서 축하중과 횡하중 등에 영향을 받는 주부재로서 많이 사용되어지고 있다. 일반적으로 철근 콘크리트(Reinforced Concrete Column, R.C. Column)이 가장 많이 설계 및 시공되고 있으며, 그 밖에도 콘크리트 충전 강관(.Concrete Filled Tube, CFT) 기둥과 같은 복합재료의 기둥이 최근 현장에 많이 적용되어 건설이 진행되고 있는 실정이다. 철근 콘크리트 기둥의 자중의 감소와 사용 재료의 절감을 위하여, 기존의 기둥에 중공부를 두는 중공 R.C 기둥이 사용되고 있다. 중공 RC의 경우 동일 단면적을 갖는 일반 R.C기둥에 비하여 큰 단면이차모멘트를 갖게 되므로 더 효율적인 단면 활용이 가능하다. 그러나 위와 같은 장점이 있는 것과는 반대로, 중공 R.C 기둥은 내측면의 취성파괴로 인하여 낮은 연성 거동을 할 가능성이 높다. 이러한 내측면의 취성 파괴는 기둥 외측면의 경우 횡철근에 의해 구속되어 있으나, 내측면의 콘크리트에는 구속력이 작용하지 않는다. 이러한 단점을 극복하기 위하여 중공면에 구속력을 작용시켜, 콘크리트를 3축 구속 상태로 만들어 주어야 한다. 이를 해결하기 위해서 중공 R.C. 기둥 중공부에 강관을 삽입함으로서 중공 기둥 내의 콘크리트를 3축 구속 상태로 만들어주는 내부 구속 중공 R.C 기둥(Internally Concfined Hollow Reinforced Concrete, ICH R.C)이 기존연구자에 의해서 제시되어졌다.(Kang & Han, 2005) 본 연구에서는 ICH RC 기둥의 열전달 해석 및 비선형 재료모델 프로그램을 이용하여 내화 성능을 분석하였으며, 중공비, 피복콘크리트의 두께, 내부강관의 두께를 변수로 선정하여 매개변수를 수행함으로서 내부 구속 중공 RC 기둥의 내화 성능을 증가 시켜주는 인자를 찾아내고 분석하였다.

실험계획법을 이용한 이탈방지 스냅핏의 최적설계 (Optimum Design of Lock Snap-fit Using Design of Experiment)

  • 손인서;신동길
    • 한국산학기술학회논문지
    • /
    • 제18권8호
    • /
    • pp.378-385
    • /
    • 2017
  • 본 연구는 플라스틱 부품의 체결에 널리 활용되고 있는 스냅핏의 설계에 관하여 연구하였다. 이탈방지 기능이 우수한 이탈방지 스냅핏은 형상과 체결 메카니즘이 복잡하여 기존의 이론식에 기반한 체결력과 이탈력을 해석적으로 구할 수가 없다. 따라서 본 연구에서는 이탈방지 스냅핏에 대하여 체결 메커니즘을 분석하고, 실험계획법에 기반하여 체결력 및 이탈력을 측정하고, 분산분석을 통하여 회귀식을 도출하였다. 실험계획은 중심합성계획을 사용하였다. Polybutylene terephthalate를 이용하여 시편을 제작하여 미소인장시험기를 이용하여 체결력과 이탈력을 측정하였다. 설계인자는 Length, Width, Thickness, Interference 등 4개를 선정하였으며, 2차 회귀모형을 이용하여 체결력과 이탈력에 대한 회귀식을 도출하였다. Length와 Width가 증가할수록 체결력은 낮아졌으며, Thickness와 Interference는 증가할수록 체결력이 증가하였다. 이탈력은 체결력과 반대의 결과를 나타내었다. 유한요소법을 이용하여 체결 역학에 대하여 분석하였다. Width는 체결단계에서 단면관성모멘트의 증가를 통한 보의 강성 증가 효과 보다는, 오히려 길이 증가에 따른 연성증대로 인하여 체결력을 감소시키는 것으로 나타났다. 낮은 체결력과 높은 이탈력을 위한 인자들의 영향도는 서로 상반되는 것으로 나타났다. 적정 수준의 이탈력을 유지하면서 체결력을 최소화하는 설계가 필요한 것으로 나타났다.

결정립크기와 집합조직제어를 통한 마그네슘 합금의 기계적 성질 개선 (Improvement of Mechanical Properties of Mg alloys through Control of Grain Size and Texture)

  • 김우진;이종범;김우영;정하국;박종덕
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.57-58
    • /
    • 2006
  • The effects of lowering ECAP temperature during ECAP process and Post-ECAP annealing on microstructure, texture and mechanical properties of the AZ31 alloys have been investigated in the present study. The as-extruded materials were ECAP processed to 2 passes at 553K prior to subsequent pressing up to 6 passes at 523K or 493K. When this method of lowering ECAP temperature during ECAP was used, the rods could be successfully deformed up to 6 passes without any surface cracking. Grain refinement during ECAP process at 553K might have helped the material to endure further straining at lower deformation temperatures probably by increasing the strain accommodation effect by grain boundary sliding, causing stress relaxation. Texture modification during ECAP has a great influence on the strength of Mg alloys because HCP metals have limited number of slip systems. As slip is most prone to take place on basal planes in Mg at room temperature, the rotation of high fraction of basal planes to the directions favorable for slip as in ECAP decreases the yield stress appreciably. The strength of AZ31 Mg alloys increases with decrease of grain size if the texture is constant though ECAP deformation history is different. A standard positive strength dependence on the grain size for Mg alloys with the similar texture (Fig. 1) supports that the softening of ECAPed Mg alloys (a negative slope) typically observed despite the significant grain refinement is due to the texture modification where the rotation of basal planes occurs towards the orientation for easier slip. It could be predicted that if the original fiber texture is restored after ECAP treatment yielding marked grain refinement, yield stress as high as 500 MPa will be obtained at the grain size of ${\sim}1{\mu}m$. Differential speed rolling (DSR) with a high speed ratio between the upper and lower rolls was applied to alter the microstructure and texture of the AZ31 sheets. Significant grain refinement took place during the rolling owing to introduction of large shear deformation. Grain size as small as $1.4{\mu}m$ could be obtained at 423K after DSR. There was a good correlation between the (0002) pole intensity and tensile elongation. This result indicates that tensile ductility improvement in the asymmetrically rolled AZ31 Mg alloys is closely related to the weakening of basal texture during DSR. Further basal texture weakening occurred during annealing after DSR. According to Hall-Petch relation shown in Fig. 1, the strength of the asymmetrically rolled AZ31 is lower than that of the symmetrically rolled one when compared at the same grain size. This result was attributed to weakening of fiber texture during DSR. The DSRed AZ31, however, shows higher strength than the ECAPed AZ31 where texture has been completely replaced by a new texture associated with high Schmid factors.

  • PDF

SFRSCC의 섬유 방향성에 미치는 입구 속도와 점성의 영향성에 대한 수치해석 (Numerical Investigation of the Density and Inlet Velocity Effects on Fiber Orientation Inside Fresh SFRSCC)

  • ;이종재;이종한;이건준;안윤규
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권3호
    • /
    • pp.16-20
    • /
    • 2018
  • 강섬유 보강 자기충전 콘크리트(Steel Fiber Reinforced Self-Compacting Concrete, SFRSCC)는 사회기반 시설이나 초고층 빌딩, 원자력 발전 시설, 병원, 댐, 수로 등 전반적으로 널리 사용되어지고 있는 재료이다. SFRSCC는 짧고, 개별적인 보강 섬유로 인해 일반적인 자기충전 콘크리트(Self-Compacting Concrete, SCC) 보다 인장 강도, 연성, 휨 강성 등에서 뛰어난 성능을 보인다. 하지만 SFRSCC의 이러한 성능은 섬유의 방향성에 의해 크게 좌우되는 경향이 있다. 짧고 개별적인 섬유들은 타설 과정에서 섬유의 방향성을 컨트롤 할 수 없기 때문에 무분별하게 콘크리트 내에 위치하게 된다. 섬유의 방향이 제어되지 않은 상태에서 콘크리트의 경화가 진행될 경우 휨 강성과 인장 강도의 저하를 야기하고, 이는 예상 강도 미달의 원인이 될 수 있기 때문에 SFRSCC를 사용할 때 섬유의 정렬은 중요한 요소가 된다. 따라서 본 연구에서는 유한 요소법을 사용하여 타설 공정 중 콘크리트 매트리스의 점도 및 입구 속도가 섬유 방향에 미치는 영향에 대해 분석하였다.

전단경간비가 작은 철근콘크리트 기둥의 소성힌지 길이 (Plastic Hinge Length of Reinforced Concrete Columns with Low Height-to-Width Ratio)

  • 박종욱;우재현;김병일;이정윤
    • 콘크리트학회논문집
    • /
    • 제22권5호
    • /
    • pp.675-684
    • /
    • 2010
  • 철근콘크리트 부재는 연성파괴를 유도하기 위해서 휨인장 파괴가 선행 하도록 구조설계한다. 또한 보에서 파괴가 진행하도록 하여 기둥에는 피해가 적게 발생하도록 한다. 하지만 소성붕괴메카니즘에 의하여 소성힌지는 보의 양단부에 발생한 이후 최종적으로 최하층 기둥의 하부에도 발생한다. 철근콘크리트 구조물의 최하층 기둥은 축력이 크게 작용하고 전단경간이 비교적 작기 때문에 휨항복을 했다고 하더라도 최종적으로는 전단파괴하거나 부차파괴하여 설계보다 취성적으로 파괴 할 가능성이 있다. 이 논문에서는 휨항복 후 전단파괴하는 10개의 실험체를 통해 소성힌지 영역의 변형율과 길이 확장에 주는 요소에 대해 파악하였다. 실험결과 세 변수 중에서 축력이 가장 크게 영향을 미쳤는데 축력이 클수록 축방향 변형률과 연성비가 뚜렷하게 줄어드는 현상을 확인할 수 있었으며 소성힌지 길이는 약간 늘어났다. 실험을 통해서 산출한 소성힌지 길이는 약 0.7~1.4d였으며 이는 기존 연구자들이 제안했던 평가식과 차이를 보여주었다.

철근콘크리트 원형 교각의 횡방향철근 변형률과 항복이후 콘크리트 전단저항 저감 (The Strain of Transverse Steel and Concrete Shear Resistance Degradation after Yielding of Reinforced Concrete Circular Pier)

  • 고성현
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권1호
    • /
    • pp.147-157
    • /
    • 2018
  • 철근콘크리트 교량에 대한 대부분의 내진설계기준들은 전체 교량 시스템의 붕괴를 방지하기 위한 성능보장설계를 암시적 또는 명시적으로 적용하고 있다. 이러한 개념 및 규정들을 명시하는 이유는 교량 전체 시스템에 설계지진하중이 작용하는 동안 철근콘크리트 교각들이 완전한 소성회전성능을 발휘할 때까지 구조적인 다른 구성요소들의 취성적인 파괴를 방지하기 위함이다. 이를 위해 철근콘크리트 교량에 대한 내진설계기준들에서는 취성적인 전단파괴를 피하도록 규정하고 있다. 성능보장의 중요한 요소 중의 하나가 교각의 연성거동을 보장하기 위한 전단강도가 충분히 확보되어야 하고 신뢰할 수 있어야 한다. 실험체 8개에 대하여 실험을 수행하였으며 모든 실험체에서 변위비 1.5%에서 다수의 휨-전단 균열이 발생되었고 최종단계까지 균열폭이 증가되었고 균열이 진전되었다. 휨-전단 균열의 각도는 부재 축과 $42^{\circ}{\sim}48^{\circ}$의 범위로 계측되었다. 본 연구에서는 실험에서 계측된 횡방향철근이 부담하는 전단강도에 대한 분석을 중심으로 하였다. 횡방향철근이 부담하는 전단강도, 축력 작용에 의한 전단강도, 콘크리트에 의한 전단강도 등 3요소에 대해 분석하였고 비교하였다. 실험체들의 콘크리트 응력은 도로 교설계기준의 응력한계를 초과하였다.

Experimental and numerical study on the structural behavior of Multi-Cell Beams reinforced with metallic and non-metallic materials

  • Yousry B.I. Shaheen;Ghada M. Hekal;Ahmed K. Fadel;Ashraf M. Mahmoud
    • Structural Engineering and Mechanics
    • /
    • 제90권6호
    • /
    • pp.611-633
    • /
    • 2024
  • This study intends to investigate the response of multi-cell (MC) beams to flexural loads in which the primary reinforcement is composed of both metallic and non-metallic materials. "Multi-cell" describes beam sections with multiple longitudinal voids separated by thin webs. Seven reinforced concrete MC beams measuring 300×200×1800 mm were tested under flexural loadings until failure. Two series of beams are formed, depending on the type of main reinforcement that is being used. A control RC beam with no openings and six MC beams are found in these two series. Series one and two are reinforced with metallic and non-metallic main reinforcement, respectively, in order to maintain a constant reinforcement ratio. The first crack, ultimate load, deflection, ductility index, energy absorption, strain characteristics, crack pattern, and failure mode were among the structural parameters of the beams under investigation that were documented. The primary variables that vary are the kind of reinforcing materials that are utilized, as well as the kind and quantity of mesh layers. The outcomes of this study that looked at the experimental and numerical performance of ferrocement reinforced concrete MC beams are presented in this article. Nonlinear finite element analysis (NLFEA) was performed with ANSYS-16.0 software to demonstrate the behavior of composite MC beams with holes. A parametric study is also carried out to investigate the factors, such as opening size, that can most strongly affect the mechanical behavior of the suggested model. The experimental and numerical results obtained demonstrate that the FE simulations generated an acceptable degree of experimental value estimation. It's also important to demonstrate that, when compared to the control beam, the MC beam reinforced with geogrid mesh (MCGB) decreases its strength capacity by a maximum of 73.33%. In contrast, the minimum strength reduction value of 16.71% is observed in the MC beams reinforced with carbon reinforcing bars (MCCR). The findings of the experiments on MC beams with openings demonstrate that the presence of openings has a significant impact on the behavior of the beams, as there is a decrease in both the ultimate load and maximum deflection.