• Title/Summary/Keyword: dual-column

Search Result 96, Processing Time 0.026 seconds

The Optimal Composing the Filter-Bed for Coping with Daily Flow-Rate Fluctuation for the Performance of Sand Filtration Process (일유량 변동에 따른 여과수질 악화에 대처하기 위한 최적 여재구성에 관한 연구)

  • Park, Dong-Hak;Park, No-Suk;Kim, Seong-Su;Bae, Cheol-Ho;Jung, Nahm-Chung;Cjoi, Seung-II
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.4
    • /
    • pp.485-491
    • /
    • 2007
  • The fluctuation of inlet flow to a water treatment plant makes a serious problem that it can change the filtration rate abruptly, and ultimately occur the breakthrough of the detained particles inside filter media. Also, since it takes very short time (about 10 minutes) for the surface wave occurred from the fluctuation of inlet flow to reach the filtration process, it is impossible to control the filtration rate stably. Therefore, this study was conducted to evaluate the effect of daily flow-rate fluctuation on the performance of sand filtration process, and to suggest the dual media composition for coping with that effect. Comparative column tests have been carried out for various dual media (sand and anthracite) compositions. From the results of column tests, dual media, especially in the case of sand 45cm/anthracite 30cm, is more effective to cope with the effect of flow-rate fluctuation on the performance of filtration than single media (only sand). In addition, irrespective of dual media composition, managing ability to cope with that fluctuation tends to be weak at the end of allowable filtration duration time,

A Method Identifying the Optimal Nonbasic Columns for the Problem Size Reduction in Affine Scaling Algorithm (애핀법에 있어서 문제 축소를 위한 최적비기저의 결정 방법)

  • ;;Park, Soondal
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.17 no.3
    • /
    • pp.59-65
    • /
    • 1992
  • A modified primal-dual affine scaling algorithm for linear programming is presented. This modified algorithm generates an elipsoid containing all optimal dual solutions at each iteration, then checks whether or not a dual hyperplane intersects this ellipsoid. If the dual hyperplane has no intersection with this ellipsoid, its corresponding column must be optimal nonbasic. By condensing these columns, the size of LP problem can be reduced.

  • PDF

Continuous Production of Fructooligosaccharides from Sucrose by a Dual Immobilized Enzyme System of Fructosyltransferase and Glucose Isomerase (과당전이효소와 포도당 이성화 효소의 고정화 혼합효소계에 의한 설탕으로부터 프락토올리고당의 연속생산)

  • 윤종원;서근학송승구
    • KSBB Journal
    • /
    • v.10 no.1
    • /
    • pp.9-14
    • /
    • 1995
  • Continuous production of fructooligosaccharides from sucrose by a dual immobilized enzyme system of fructosyltransferase and glucose isomerase was studied in a column reactor. The optimal temperature and pH of the immobilized fructosyltransferase were $65^{\circ}C$ and 5.5, respectively. The activity of glucose isomerase was favorable as temperature and pH were increased within the ranges examined. However, both the immobilized enzymes were thermally unstable over $5^{\circ}C$, suggesting that long-term operation of the dual immobilized enzyme column should be carried out below $50^{\circ}C$. The optimum packing ratio of fructosyltransferase to glucose isomerase was found to be around 5/3. Under the optimized reaction conditions, the dual enzyme column was successfully operated for 40 days without any loss of initial enzyme activities, yielding 66% of fructooligosaccharides. Furthermore, the relative sweetness of fructooligosaccharides produced by a dual emzyme system was enhanced by 6% compared with that of fructosyltransferase alone.

  • PDF

Experiment and bearing capacity analyses of dual-lintel column joints in Chinese traditional style buildings

  • Xue, Jianyang;Ma, Linlin;Wu, Zhanjing;Zhai, Lei;Zhang, Xin
    • Steel and Composite Structures
    • /
    • v.28 no.5
    • /
    • pp.641-653
    • /
    • 2018
  • This paper presents experiment and bearing capacity analyses of steel dual-lintel column (SDC) joints in Chinese traditional style buildings. Two SDC interior joints and two SDC exterior joints, which consisted of dual box-section lintels, circular column and square column, were designed and tested under low cyclic loading. The force transferring mechanisms at the panel zone of SDC joints were proposed. And also, the load-strain curves at the panel zone, failure modes, hysteretic loops and skeleton curves of the joints were analyzed. It is shown that the typical failure modes of the joints are shear buckling at bottom panel zone, bending failure at middle panel zone, welds fracturing at the panel zone, and tension failure of base metal in the heat-affected zone of the joints. The ultimate bearing capacity of SDC joints appears to decrease with the increment of axial compression ratio. However, the bearing capacities of exterior joints are lower than those of interior joints at the same axial compression ratio. In order to predict the formulas of the bending capacity at the middle panel zone and the shear capacity at the bottom panel zone, the calculation model and the stress state of the element at the panel zone of SDC joints were studied. As the calculated values showed good agreements with the test results, the proposed formulas can be reliably applied to the analysis and design of SDC joints in Chinese traditional style buildings.

On dual transformation in the interior point method of linear programming (내부점 선형계획법의 쌍대문제 전환에 대하여)

  • 설동렬;박순달;정호원
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1996.10a
    • /
    • pp.289-292
    • /
    • 1996
  • In Cholesky factorization of the interior point method, dense columns of A matrix make dense Cholesky factor L regardless of sparsity of A matrix. We introduce a method to transform a primal problem to a dual problem in order to preserve the sparsity.

  • PDF

A Study of the Physical Properties of Single Wall Dual-layer Medium Corrugated Board (강심골판지의 물성에 관한 연구)

  • Lee, Soo-Keun;Kim, Jai-Neung
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.10 no.1
    • /
    • pp.47-54
    • /
    • 2004
  • Normally, the single wall(SW) corrugated board has more advantages than double wall (DW) corrugated board in terms of the cost of the materials and logistics. For instance, the SW corrugated board has 3 layer papers whereas the DW corrugated board has 5 layer papers. The thickness of the SW is about 5mm, but that of the DW is 8mm. Accordingly, the SW corrugated board is quite more used in the developed countries than the DW corrugated board. But in Korea, the DW corrugated board is quite more used. The reason why more DW corrugated board are used than the SW corrugated in Korea is that in order that the SW corrugated board has the same box compression strength as DW corrugated board, the cost of the SW corrugated board is higher than that of the DW corrugated board because the virgin kraft liners are all imported from overseas. In this study, the physical properties such as flat crush strength and column crush strength of typical SW corrugated board and single wall dual-layer medium corrugated board and their costs were analyzed. The analysis resulted in that single wall dual-layer medium corrugated board has the same thickness as the SW corrugated board but the more flat crush strength and column crush strength and the less cost than the SW corrugated board.

  • PDF

Spectrophotometric Determination of Ultra trace Tri & Hexavalent Chromium by Using on-line Flow Injection Analysis with Dual Pre-concentration Column

  • Jung, Sung-Woon;Lim, Hyun-Woo;Kang, Chul-Ho;Choi, Yong-Wook
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.9
    • /
    • pp.3437-3442
    • /
    • 2011
  • An on-line flow injection analysis with dual pre-concentration method was developed to determine the ultra trace tri and hexavalent chromium in water. In this system, the cation and anion pre-concentration columns were combined with a 10-port injection valve and then used to separate and concentrate Cr (III) and Cr (VI) selectively. The two species of concentrated chromium were sequentially eluted and determined by using HCl-KCl buffer of pH 1.8 as an eluent. Cr (III) was oxidized by hydrogen peroxide to Cr (VI). It was detected spectrophotometrically at 548 nm by complexation with DPC (diphenylcarbazide). Several factors such as concentration of $H_2O_2$, DPC and coil length in reaction condition were optimized. The linear range for Cr (III) and Cr (VI) was 0.1-50 ${\mu}g$/L. The limit of detections ($3{\sigma}$) of Cr (III) and Cr (VI) were 52 ng/L and 44 ng/L under the optimized FIA system, and their recoveries 98% and 103%, respectively. This method was applied to analyze contamination level of chromium species in tap water, groundwater and bottled water.

하수처리장 방류수를 이용한 인공함양 가능성 평가

  • 김병군;서인석;홍성택;김형수
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.257-260
    • /
    • 2002
  • The main purpose of this research is to find suitable treatment methods of wastewater effluent for artificial recharge. For this purpose, we search the effluent quality of wastewater treatment plant and possibility of additional filtration process. Particles ranged 2 ~ 5 ${\mu}{\textrm}{m}$ and 15~20 ${\mu}{\textrm}{m}$ in "T" WWTP(Waste Water Treatment Plant) effluent were relatively dominant. In dual-media filtration system operation, head-loss development of column 1 was about two times faster than column 2, and head-loss development within 5 cm from surface was very important factor in operation, Conclusively, for the stable filtration and running time of 1.5~2 day, influent turbidity must keep 5 NTU or below, and filtration system must operated at 280 m/day or below. After filtration of WWTP effluent, water quality reached satisfactory level. This water has potential of agricultural reusing, flushing water in building, recharging water to river or stream at dry season and artificial recharge of ground water.und water.

  • PDF

Dual Capillary Column System for the Qualitative Gas Chromatography: 1. Comparison Between Split and Splitless Injection Modes

  • Kim, Kyoung-Rae;Kim, Jung-Han;Park, Hyoung-Kook;Oh, Chang-Hwan
    • Bulletin of the Korean Chemical Society
    • /
    • v.12 no.1
    • /
    • pp.87-92
    • /
    • 1991
  • A dual capillary column system is described for the simultaneous measurement of retention index (RI) and area ratio (AR) values of each peak on two capillary columns of different polarity, DB-5 & DB-1701. Both capillary columns were connected to a common splitless injector via a deactivated fused-silica capillary tubing of 1 m length and a 'Y' splitter, the dead volume effect of which was found to be negligible. RI and AR were measured with high reproducibility(${\leq}$0.05% RSD) and with high accuracy (<10% RE), respectively. When applied to the test samples of the organic acid mixture, each acid was positively identified by the combined computer RI library search-AR comparison.

Correspondence Analysis of Two-way Contingency Tables with Ordered Column Categories

  • Yang, Kyung-Sook;Huh, Myung-Hoe
    • Journal of the Korean Statistical Society
    • /
    • v.28 no.3
    • /
    • pp.347-358
    • /
    • 1999
  • Correspondence analysis is an exploratory method for two-way contingency tables intended to display the association pattern between row and column categories. It has been developed for several decades mainly in France and Japan and, nowadays, is popular worldwide. For the special case, however, that the column consists of ordered categories, correspondence analysis may yield ackward result so that it cannot be fully accommodated. That's because the row and column categories are assumed to be nominal in the ordinary correspondence analysis. The aim of this study is to develop the correspondence analysis for two-way contingency tables with ordered column categories. It is based on two specific algorithms,

  • PDF