• 제목/요약/키워드: dual pipeline

검색결과 25건 처리시간 0.026초

트렌치내에서 복합 해저 관로 안정성의 수치해석과 실험해석 비교 (Comparison of Numerical and Experimental Stability of Dual Subsea Pipeline in Trench)

  • Chul H. Jo;Young S. Shin;Sung G. Hong;Kyoung H. Min;Chung, Kwang-Sic
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.254-259
    • /
    • 2001
  • There are advantages in the installation of dual subsea pipelines over two separate single lines. In many case it can reduce the cost for trench, back-filling and installation. However the installation of dual pipelines often requires technical challenges. Dual Pipelines should be placed to be stable to external loading not only during the installation but also in the design life. Dual pipelines in trench can reduce the influence of external forces. To investigate applied forces as slope changes, number of experiments are conducted with PIV (Particle Image Velocimetry) in a circulating water channel. Numerical approaches are also made to compare with experimental results. The velocity fields around dual pipelines in trench are investigated and analysed. Comparison of both results show similar pattern of flow around dual pipelines. it is proved that the trench slope affects the pipeline stability significantly. The results can be applied in the stability design of dual pipelines in trench section. The complex flow patterns can be referenced effectively linked in the understanding of fluid around circular bodies in trench.

  • PDF

듀얼 페이즈 명령어 파이프라인구조의 쉐이더 프로세서 설계 (A Design of a Shader Processor based on a dual-phase pipeline architecture)

  • 정형기;남기훈;이광엽
    • 전기전자학회논문지
    • /
    • 제12권4호
    • /
    • pp.246-254
    • /
    • 2008
  • 본 논문에서는 멀티 스레드와 듀얼 페이즈 명령어 파이프라인을 가진 4way SIMD 프로세서를 설계하였다. 8개의 스레드가 round-robin 방식으로 실행되어, 해저드를 발생시키지 않는다. 또한 듀얼 페이즈 기능은 1개의 코어가 2개의 프로세서처럼 동작하도록 명령어를 최대 4개를 입력 받아 처리한다. 이 가변 명령어 구조는 1차와 2차 페이즈로 나뉘어 명령어를 수식할 수 있으며, 이 기능을 통해 분기명령이나 어드레싱 명령을 단일 클럭에 수행할 수 있도록 한다. 이 프로세서는 명령어 수행 시간을 일반적인 SIMD 구조에 비하여 50% 이하로 단축시킬 수 있으며, 최대 2배의 성능향상을 보이고 25%까지 코드 크기를 줄일 수 있다..

  • PDF

Novel Electromagnetic Induction Eddy Current DPH based Continuous Pipeline Fluid Heating using Soft Switching PWM High Frequency Inverter

  • Nam, Jing-Rak
    • Journal of information and communication convergence engineering
    • /
    • 제6권3호
    • /
    • pp.305-309
    • /
    • 2008
  • This paper presents an innovative prototype of a new conceptual electromagnetic induction eddy current based fluid heating appliance using voltage-fed quasi resonant zero voltage soft switching PWM high-frequency inverter using IGBTs, which can operate at a constant frequency variable power regulation scheme. The promising simple high efficient low noise inverter type electromagnetic induction eddy current based pipeline fluid heating appliance is proposed for saturated steam generator, superheated steam generator, hot water and hot air producer, metal catalyst heating for exhaust gas cleaning in engine. Under these technological backgrounds, a novel electromagnetic induction eddy current Dual Packs Heater(DPH) based pipeline fluid heating incorporates thin metal layer type package for continuous fluid heating appliances applying two types of voltage-fed quasi load resonant ZVS-PWM high frequency inverter. The unique features of a novel electromagnetic induction eddy current DPH based continuous pipeline fluid heating appliance is illustrated on the basis of simulation and discussed for the steady state operating characteristics and experimental results.

Numerical and Experimental Studies of Dual Subsea Pipelines in Trench

  • Jo, Chul H.;Shin, Young S.;Min, Kyoung H.
    • Journal of Ship and Ocean Technology
    • /
    • 제6권2호
    • /
    • pp.12-22
    • /
    • 2002
  • Offshore pipelines play an important role in the transportation of gas, oil, water and oil products. It is common to have a group of pipelines in the oil and gas field. To reduce the installation cost and time, dual pipelines are designed. There are great advantages in the installation of dual pipelines over two separate single lines. It can greatly reduce the cost for trench, back-filling and installation. However the installation of dual pipelines often requires technical challenges. Pipelines should be placed to be stable against external loadings during installation and design life period. Dual pipelines in trench can reduce the influence of external forces. To investigate the flow patterns and forces as trench depth and slope changes, number of experiments are conducted with PIV(Particle Image Velocimetry) equipment in a Circulating Water Channel. Numerical approaches to simulate experimental conditions are also made to compare with experimental results. The velocity fields around dual pipelines in trench are investigated and analysed. Comparison of both results show similar patterns of flow around pipelines. It is proved that the trench depth contributes significantly on hydrodynamic stability. The trench slope also affects the pipeline stability. The results can be applied in the stability design of dual pipelines in trench section. The complex flow patterns can be effectively linked in the understanding of fluid motions around multi-circular bodies in trench.

해저면에 설치된 2차원 복합해저관로 주위의 유동특성에 관한 실험적 연구 (A Study of Flow Pattern around the Two-Dimensional Dual Subsea Pipeline on Sea Bottom)

  • 나인삼;조철희;정우철;김두홍
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2001년도 추계학술대회 논문집
    • /
    • pp.122-127
    • /
    • 2001
  • As pipelines are often used to transport gas, oil, water and oil products, there are more than one pipeline installed in the offshore field. The size and space of pipelines are various depending on the design specifications. The pipelines are to be designed and installed to secure the stability to external loads during the installation and operation period. The flow patterns are very complex around the pipelines being dependent on incoming flow velocity, pipelines size and space. To investigate the flow patterns, number of experiment are conducted with visualization equipment in a circulating water channel. The flow motion and trajectory were recorded from the laser reflected particles by camera. From the experiment the flow patterns around spaced pipelines were obtained. Also pressure gradient was measured by mano-meter to estimate the hydrodynamic forces on the behind pipeline. The results show that the various sizes and spaces can be affected in the estimation of external load. The complex flow patterns and pressure gradients can be effectively used in the understanding of flow motion and pressure gradient.

  • PDF

이변량 감소모델을 적용한 배급수관망에서의 잔류염소농도 예측 및 이의 활용 (Prediction of residual chlorine using two-component second-order decay model in water distribution network)

  • 김영효;권지향;김두일
    • 상하수도학회지
    • /
    • 제28권3호
    • /
    • pp.287-297
    • /
    • 2014
  • It is important to predict chlorine decay with different water purification processes and distribution pipeline materials, especially because chlorine decay is in direct relationship with the stability of water quality. The degree of chlorine decay may affect the water quality at the end of the pipeline: it may produce disinfection by-products or cause unpleasant odor and taste. Sand filtrate and dual media filtrate were used as influents in this study, and cast iron (CI), polyvinyl chloride (PVC), and stainless steel (SS) were used as pipeline materials. The results were analyzed via chlorine decay models by comparing the experimental and model parameters. The models were then used to estimate rechlorination time and chlorine decay time. The results indicated that water quality (e.g. organic matter and alkalinity) and pipeline materials were important factors influencing bulk decay and sand filtrate exhibited greater chlorine decay than dual media filtrate. The two-component second-order model was more applicable than the first decay model, and it enabled the estimation of chlorine decay time. These results are expected to provide the basis for modeling chlorine decay of different water purification processes and pipeline materials.

A Low Power Dual CDS for a Column-Parallel CMOS Image Sensor

  • Cho, Kyuik;Kim, Daeyun;Song, Minkyu
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제12권4호
    • /
    • pp.388-396
    • /
    • 2012
  • In this paper, a $320{\times}240$ pixel, 80 frame/s CMOS image sensor with a low power dual correlated double sampling (CDS) scheme is presented. A novel 8-bit hold-and-go counter in each column is proposed to obtain 10-bit resolution. Furthermore, dual CDS and a configurable counter scheme are also discussed to realize efficient power reduction. With these techniques, the digital counter consumes at least 43% and at most 61% less power compared with the column-counters type, and the frame rate is approximately 40% faster than the double memory type due to a partial pipeline structure without additional memories. The prototype sensor was fabricated in a Samsung $0.13{\mu}m$ 1P4M CMOS process and used a 4T APS with a pixel pitch of $2.25{\mu}m$. The measured column fixed pattern noise (FPN) is 0.10 LSB.

듀얼 모드 위상 시프트 ZVS PWM 제어 고주파 공진형 인버터를 이용한 IH 온수기 (Induction Heating Water Heater using Dual Mode Phase Shifted ZVS-PWM High Frequency Resonant Inverter)

  • 정상석;유의정;우경일;박한석
    • 전기학회논문지P
    • /
    • 제67권2호
    • /
    • pp.82-89
    • /
    • 2018
  • This paper presents a novel prototype of dual mode control based phase shift ZVS PWM high frequency load resonant inverter with lossless snubber capacitors in addition to a single active auxiliary resonant snubber for electromagnetic induction heating(IH) foam metal based consumer fluid dual packs(DPA) heater. The operating principle in steady state and unique features of this voltage source soft switching high frequency inverter circuit topology are described in this paper. The lossless snubber and auxiliary active resonant snubber assisted constant frequency phase shift ZVS PWM high frequency load resonant inverter employing IGBT power modules actually is capable of achieving zero voltage soft commutation over a widely specified power regulation range from full power to low power. The steady state operating performances of this dual mode phase shift PWM series load resonant high frequency inverter are evaluated and discussed on the basis of simulation and experimental results for induction heated foam metal heater which is designed for compact and high efficient moving fluid heating appliance in the consumer pipeline systems.

미소변형 해석을 위한 Dual-beam Shearography (Strain Analysis by Dual-beam Shearography)

  • 김경석;최태호;김성식;최정석
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2003년도 춘계학술대회 논문집
    • /
    • pp.251-254
    • /
    • 2003
  • In recent years, shearogrpahy has significantly improved capabilities In the areas of unbend and separation detection in tires. Although shearography has many advantages fur qualitative evaluation, the technique remains the problem of quantitative analysis of inside defects, because shearography needs several effective factors including the amount of shearing, shearine direction and induced load, which exist as barrier for the quantitative analysis of inside defects. Since the factors are highly dependent on inspectors skill and also affect the in-situ workability. The factors were optimized and the size of cracks inside of pipeline and tire has been quantitatively determined.

  • PDF

멀티코어 GP-GPU를 이용한 지오메트리 처리 (Geometry Processing using Multi-Core GP-GPU)

  • 이광엽;김치용
    • 전기전자학회논문지
    • /
    • 제14권2호
    • /
    • pp.69-75
    • /
    • 2010
  • 3D 그래픽 처리 과정은 크게 지오메트리 단계와 렌더링 단계로 구분된다. 본 논문에서는 듀얼페이즈 멀티코어 GP-GPU에서 지오메트리 처리를 가속화시키기 위한 방법을 제안한다. GP-GPU의 SIMD, 듀얼페이즈 구조를 이용한 병렬적 데이터 처리와 메모리 프리패치를 이용하여, 지오메트리 처리를 가속화 시킬 수 있었으며, 모든 기능을 사용할 시 19%의 성능 향상을 나타내었다.