• 제목/요약/키워드: drying chamber

Search Result 89, Processing Time 0.023 seconds

The Effect of Cement Mixture on Plastic Shrinkage of Concrete (시멘트 배합량이 콘크리트의 소성수축에 미치는 영향)

  • 오무영;윤충섭
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.18 no.4
    • /
    • pp.4226-4231
    • /
    • 1976
  • The objective of this study is to investigate the characteristics of the concrete mixture and the plastic shrinkage of concrete exposed to a rapid evaporation immediately after placement, and to measure the shringkage rate according to the cement-mixture. Drying of concrete was conducted under a controlled chamber in which the temperature was 36${\pm}$2$^{\circ}C$, the relative humidity 45${\pm}$2%, and the wind velocity 4${\pm}$1m/sec. All of the concrete mo1ds were made to have good workability as 6${\pm}$0.5cm in slump. The results obtained are as follows; 1) The evaporation rate was 3.36kg/$\textrm{km}^2$, 2.98kg/$\textrm{km}^2$ and 2.91kg/$\textrm{km}^2$ respectively for each concretemixtures 365kg, 335kg and 317kg after 5 hour exposure, and the evaporation was measured at all 55∼57% after 2 hours and additional in 10% on after 5 hours exposure. 2) The weight of the concrete were was reduced to 3.0%, 2.6% and 2.4% respectively for each of them. 3) The shrinkage of concrete was 0.87 mm/m, 0.56mm/m and 0.31 mm/m after 5 hour exposure, and the shringkage of concrete was measured at 84%, 59% and 45% after 2 hours and it in 1∼5% after 5 hour exposure and then stopped. 4) A recommendation for good concrete is that the evaporation should be minimized during 2 hours after placement of concrete, if possible.

  • PDF

The study on the estimation of heat transfer coefficient through the counterflow concentric tube using refrigerant and moisture air (냉매와 습공기가 교차하는 2중관에서 전열계수 예측을 위한 연구)

  • 조권희
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.5
    • /
    • pp.687-694
    • /
    • 1999
  • This study was conducted to develop new drying process for automatic control and marine engi-neering system. Air-water tests were carried out to investigate dryer performance. The dispersed flow in he dryer test apparatuses was also simulated by using a numerical code which solves the Dittus-Boelter equation for continuous liquid phase and the Reynolds equation of droplet motion for continuous liquid phase and the Reynolds equation of droplet motion for dispersed phase to predict droplet removal efficiency. Proper conditions for dehumidification were optimized by response ambient conditions. When the selected indexes were constrained in the range of 85-98% moisture content above $15^{\circ}$ and more than mass flow rates of moist air 750kg/h. The numerical results were compared with the experimental data pertaining to the removal effi-ciency at chamber stage and overall pressure drop along concentric tubes Good agreement was obtained as for the efficiency while relatively poor agreement was obtained for the relative humidity. The results also showed that the efficiency depended strongly on the relative humidity at the inlet condition which indicated the importance of estimating the heat exchanger length. Effects of some design parameters in both removal efficiency and breakthrough onset condition are discussed.

  • PDF

Preparation of Alginate-fibroin Beads with Diverse Structures (다양한 구조를 가진 알긴산-피브로인 비드 제조)

  • Lee, Jin-Sil;Lee, Shin-Young;Hur, Won
    • KSBB Journal
    • /
    • v.26 no.5
    • /
    • pp.422-426
    • /
    • 2011
  • Alginate bead has been supplemented with various polymers to control permeability and to enhance mechanical strength. In this report, fibroin-reinforced alginate hydrogel was prepared, in which spatial localization of fibroin molecules was investigated. Confocal laser scanning microscopy revealed that fibroin molecules formed a fibrous network in the alginate-fibroin beads, which was expected to enhance mechanical strength as same as in many composite materials. Uniaxial compression test showed that fibroin-reinforced alginate beads had increased mechanical strength only after methanol treatment that caused ${\beta}$-sheet formation among fibroin molecules. Simultaneous curing and dialysis of alginate beads were carried out to remove excesscalcium but to retain fibroin in the dialysis chamber, which fabricated beads without internal fibrous fluorescent stains. Fibroin molecules were only found beneath the surface of the beads. The fibroin-diffused shell was further processed to form a thick wall after drying or was mobilizedto the centre of the bead by methanol treatment. Accordingly, the structure analyses provide processing methods of fibroin to form a wall or center clumps, which could be applied to design controlled delivery device.

Operation of Sewage Sludge Composting Plant(Capacity of 1 ton/day) (1톤/일 처리규모의 하수슬러지 퇴비화 실증운전)

  • Joung, Kyong-Chul;Kwak, No-Hyuk;Park, Sung-Hee;Phae, Jae-Kuen
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.8 no.2
    • /
    • pp.77-84
    • /
    • 2000
  • Aim to get operation factors, an In-vessel Composting of Wastewater Sludge was operated. The composting equipment is consisted of three chamber, 1st, 2nd and 3rd consequently. In the results, the temperature of fermentation had shown that 1st fermentation chamber(F/C) temperature was higher than that of 2nd and 3rd fermentation chamber. The temperature was steady in all steps during the sludge being composted, the ranges of each step were $50^{\circ}{\sim}59^{\circ}C$ of 1st F/C, $41^{\circ}{\sim}50^{\circ}C$ of 2nd F/C, and $32^{\circ}{\sim}37^{\circ}C$ of 3rd F/C. Organic material content of the end product was 28% and that of pH was 7.5. Properties of the compost which have been composted on optimized condition, were shown that is acceptable to use as a fertilizer. Even in the winter time, the composting system was working well without any trouble. According to result of investigation, the end-product of the system was satisfied with the standard for a fertilizer usage. HRT(hydraulic retention time) of entire process was appropriated to be 14 days(0.9 days at drying and 3.5, 4.4, 5.2 days at each step of fermentations, respectively).

  • PDF

Variation of Hydrogen Residue on Metallic Samples by Thermal Soaking in an Inert Gas Environment (불활성 가스하 열건조에 따른 금속시험편의 수소잔류물 거동 분석)

  • Lee, Yunhee;Park, Jongseo;Baek, Unbong;Nahm, Seunghoon
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.24 no.1
    • /
    • pp.44-49
    • /
    • 2013
  • Hydrogen penetration into a metal leads to damages and mechanical degradations and its content measurement is of importance. For a precise measurement, a sample preparation procedure must be optimized through a series of studies on sample washing and drying. In this study, two-step washing with organic solvents and thermal soaking in inert gas were tried with a rod-shaped, API X65 steel sample. The samples were machined from a steel plate and then washed in acetone and etyl-alcohol for 5 minute each and dried with compressed air. After then, the samples were thermally soaked in a home-made nitrogen gas chamber during 10 minute at different heat gun temperatures from 100 to $400^{\circ}C$ and corresponding temperature range in the soaking chamber was from 77 to $266^{\circ}C$ according to the temperature calibration. Hydrogen residue in the samples was measured with a hot extraction system after each soaking step; hydrogen residue of $0.70{\pm}0.12$ wppm after the thermal soaking at $77^{\circ}C$ decayed with increase of the soaking temperature. By adopting the heat transfer model, decay behavior of the hydrogen residue was fitted into an exponential decay function of the soaking temperature. Saturated value or lower bound of the hydrogen residue was 0.36 wppm and chamber temperature required to lower the hydrogen residue about 95% of the lower bound was $360^{\circ}C$. Furthermore, a thermal desorption spectroscopy was done for the fully soaked samples at $360^{\circ}C$. Weak hydrogen peak was observed for whole temperature range and it means that hydrogen-related contaminants of the sample surface are steadily removed by heating. In addition, a broad peak found around $400^{\circ}C$ means that parts of the hydrogen residue are irreversibly trapped in the steel microstructure.

An Archaeological Review of the Inscribed Bricks Excavated from the Tomb of Jang Mui: A Focus on the Collection of the National Museum of Korea (장무이묘 출토 명문전(銘文塼)의 고고학적 검토 -국립중앙박물관 소장품을 중심으로)

  • Lee Nakyung
    • Bangmulgwan gwa yeongu (The National Museum of Korea Journal)
    • /
    • v.1
    • /
    • pp.36-73
    • /
    • 2024
  • The Tomb of Jang Mui located in Bongsan-gun, Hwanghae-do Province has attracted much attention since its first investigation due to the inscribed bricks found there that have allowed the guessing of the name and official title of its occupant and construction date. Inscriptions on these bricks, such as the "Prefect of Daebang Commandery Jang Mui" and the "Mu" (戊, the fifth sign of the Chinese calendar), and "Sin" (申, the ninth sign of the Chinese zodiac), have become the basis for believing the location of the government office of Daebang Commandery to be in Bongsangun, Hwanghae-do Province rather than somewhere in the Hangang River region. From the early days of its investigation, the tomb was suggested as historic remains of the Daebang Commandery along with the Earthen Fortress in Jitap-ri. Inscribed bricks excavated from the Tomb of Jang Mui were featured in several books and articles in the form of photographs and rubbings, leading to a vast body of studies on its construction period and the characteristics of its occupant that drew upon interpretations of the inscriptions. However, the inscribed bricks themselves were not publicly available outside those held in the collection of the University of Tokyo, making it difficult to expect consistent research findings on the types of inscribed bricks and their contents. Following previous studies re-examining the structure of the tomb and the materials used for its construction, most scholars dated the Tomb of Jang Mui to 348, a period after the collapse of Daebang Commandery. However, there is still a lack of adequate examination of the bricks, which account for the majority of the artifacts excavated from the tomb. Among the bricks excavated from most brick chamber tombs, including the Tomb of Jang Mui, only those with inscriptions or designs have been collected. Moreover, among these, only those with inscriptions or designs on the stretcher faces have been documented. Accordingly, the bricks themselves have been notably understudied. This paper intends to reorganize the contents of the inscriptions on eleven types (out of sixty-one pieces) of bricks in the collection of the National Museum of Korea, which make up the majority of the bricks excavated from the Tomb of Jang Mui. It also classified them according to their shapes. Furthermore, it examined the bricks from the Tomb of Jang Mui as architectural materials by focusing on their production techniques, including their forming, drying, and firing. Taking a more specific approach, it then compared the results to other bricks from the second century through the fourth century: those from the brick chamber tombs of the Nangnang and Daebang Commanderies and those from the brick chamber tombs built after Nangnang and Daebang Commanderies were ousted. The examination of bricks from the Tomb of Jang Mui has revealed that these bricks were basically produced using the brick manufacturing techniques of Nangnang, but they incorporated new elements found in bricks from brick chamber tombs or brick-and-stone chamber tombs constructed around the mid-fourth century in terms of their size, the use of lime, and the number of inscribed bricks. This supports the prevailing view that the date of the construction of the Tomb of Jang Mui is 348. The Tomb of Jang Mui sustained the existing brick chamber tomb burial tradition, but its ceiling was finished with stone. It demonstrates a blending of the brick chamber tomb practice of the Nangnang and Daebang Commanderies by using bricks produced based on related techniques, but with new elements such as the addition of a lime layer to the bricks. This fusion reflects the political circumstances of its time, such as the expulsion of the Daebang Commandery and the advance of the Goguryeo Kingdom, leading to diverse interpretations. Given archaeological evidence such as the structure, materials, and location of the tomb, the Tomb of Jang Mui appears to be highly related to the Goguryeo Kingdom. However, the forms of the inscribed bricks and the contents of the inscriptions share similarities with brick chamber tombs constructed during the third and fourth centuries in the Jiangsu and Zhejiang regions in China. Further studies on whether the use of lime was an influence from Goguryeo or a continuation of the Daebang tradition and a comparative examination with contemporaneous stone ceiling tombs will provide a more refined understanding of the Tomb of Jang Mui.

Characteristics of Volatile Organic Compounds and Aldehydes Emission from Yellow poplar (Liriodendron tulipifera L.) (백합나무 판재의 VOCs 및 Aldehydes 방출특성)

  • Lee, Min;Park, Sang-Bum;Lee, Sang-Min;Son, Dong-Won
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.4
    • /
    • pp.357-366
    • /
    • 2014
  • Based on fundamental properties and machining characteristics of Yellow poplar (Liriodendron tulipifera L.), it has well performance on machinability or workability, drying, and fine surface. Additionally, yellow poplar is light weight and has bright color with high performance of bending processing, so it could be used for furniture or artworks materials and wood-based panel materials. Recently, public attention has been focused on indoor air quality, and Ministry of environment drift more tight regulation on indoor air quality for an apartment house and public facility with the times. Construction materials has been assessed emission of volatile organic compounds (VOCs) and formaldehyde according to law (No.10789), so yellow poplar is also needed to assess these emission characteristics. Emission of VOC and aldehyde compounds from dry and green wood condition of yellow poplar were investigated with KS M 1998:2009. Based on results, more than 30 compounds were detected from yellow poplar, and lower NVOC (natural VOC) were emitted than AVOC (Anthropogenic VOC) and OVOC (other VOC). Formaldehyde emission was lower than $5{\mu}g/m^3$ and acetaldehyde, ketone, and propionaldehyde were detected from yellow poplar. From dry yellow poplar, m-Tolualdehyde ($33.6{\mu}g/m^3$) was additionally detected while no detection of propionaldehyde. After drying process, amount of ketone emission increased significantly. The unique smell of yellow poplar may not only come from emission of acetaldehyde and propionaldehyde.

Evaluation of TVOC regulation level of sealant products in accordance with simultaneous revision of testing method and regulation value in the law of indoor air quality management (실내 공기질 공정시험방법과 기준의 동시 개정에 따른 실란트 제품의 TVOC 관리수준 평가)

  • Yoo, Ji-Ho;Park, Joon-Man;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.138-146
    • /
    • 2010
  • The Korean Ministry of the Environment revised a few sections of the regulations in the Law of indoor air quality management for the reinforcement or adjustment of the regulation criteria standard for releasing pollutants from building materials. Especially, in case of sealant, the contents covering liquid building materials, excess standards and testing methods have been added simultaneously in this revision, As a result it is impossible to compare original standards with revised standards directly. For this reason, this study reviewed revised test method of sealant pollutant emission rates in terms of impact and validity in comparison with the original test method. Through this study, the basic properties of revised pollutant emission control standards was assessed. Especially in sealant, since each product has a wide deviation of time required for complete drying, it is proved that there are a large number of products that are not hardened completely in test time. The result of our experiments on the revised test methods showed that this revised test methods yield emission rates that are two and half times less than those of the original testing method. To apply the revised test method of sealant to all the sealant products, It is necessary to extend the test period or improve specimen to fit the test method for quickly drying sealant products.

Assessment of the Wear Comfort of Outdoorwear by ECG and EEG Analyses (아웃도어웨어의 착용 쾌적성 평가를 위한 심전도 및 뇌파 분석)

  • Jeong, Jeong-Rim;Kim, Hee-Eun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.33 no.10
    • /
    • pp.1665-1672
    • /
    • 2009
  • This study examines the comfort of outdoorwear by electrocardiogram (ECG) and electroencephalogram (EEG) analyses. An experiment that consisted of rest (30 min), exercise (30 min), and recovery (20 min) periods was administered in a climate chamber with 10 healthy male participants. Two kinds of outdoorwear made of 100% cotton fabrics ('Control') and specially engineered fabrics having the feature of quick sweat absorbency and high speed drying fabric ('Functional') are evaluated in the experiment. ECG and EEG signals were obtained during the rest and recovery periods for the two outdoorwear conditions. The ECG analysis identified a smaller decrement of high frequency (HF) power for the 'Functional' when compared with the 'Control' during the recovery period. Next, the EEG analysis showed that the relative band powers of slow $\alpha$ and mid $\alpha$ increased for the 'Functional' while they decreased for the 'Control' and that the ratio of $\alpha$ power to high $\beta$ power was higher for the 'Functional'. The evaluation results indicate that the participants could remain relaxed more with less stress while wearing the functional outdoorwear that demonstrated the positive effects on autonomic nervous system (ANS) activities. The present study is significant in regard that use of ECG and EEG for the assessment of wear comfort is the first in the field of clothing and textile.

Thermal Comfort of the Sports/Leisure Clothing with the Heat Storage/Reflection Function - Wearing Evaluation under the Condition of 0x00B1;1℃ and 50±5% RH - (축열/체열반사기능을 가진 스포츠 레저복의 온열쾌적성 - 0±1℃, 50±5% RH 환경에서의 착의평가 -)

  • Kim, Tae-Gyou;Song, Min Kyu;Lee, Chang Min;Kwon, Oh Kyung
    • Fashion & Textile Research Journal
    • /
    • v.20 no.4
    • /
    • pp.474-481
    • /
    • 2018
  • For this study, we developed clothing in which textile materials that were excellent weather control function for the cold environment and we performed the human subject test with developed clothing to determine the thermal comfort. We used 2 clothing samples developed (A and B, hollow yarn+moisture absorption/quick drying yarn, 3 layers, high stretchable, heat reflection film and lamination treated) and a control sample (Ctrl.) for the human subject test and 8 adult males were used as a human subjects and environmental conditions of chamber were $0{\pm}1^{\circ}C$. $50{\pm}5%RH$, 0.3m/sec. The results were as follows: The average skin temperature and hand, thigh temperature of B were higher than B and Ctrl. (p<.05). The micro-climates of B were near to thermal comfort range which is $32{\pm}1^{\circ}C$ and $50{\pm}10%\;RH$. The chest temperature of B was significantly higher than others (p<.05). The relative humidity of B was lower than others and kept stable rather than others. The thermal sensation of B was near the "neutral" and was significantly different from Ctrl. (p<.01) and the weight loss of B was lower than Ctrl. (p<.05). The counting task and hand temperature was positively related and the counting task value of B and A is bigger than Ctrl. and that of A was bigger than Ctrl. (p<.05).