• Title/Summary/Keyword: dry test

Search Result 1,846, Processing Time 0.027 seconds

Evaluation for Mechanical Properties of Compress Strength and Dry Density of Concrete at NPP (원전 시설용 콘크리트의 압축강도 및 건조밀도 특성 평가)

  • Lee, Young-Dae;Kim, Gyu-Yong;Shin, Kyoung-Su;Nam, Jeong-Soo;Lee, Tae-Gyu;Choe, Gyeong-Choel
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.53-54
    • /
    • 2011
  • The facilities producing the nuclear energy chosen for resolving the recent global energy problem have been increasingly constructed, and hence more frequent durability tests on radiation shielding concrete are required due to NPP(Nuclear Power Plant) life extension and increase of radioactive waste repositories. Bulk dry density is one of the critical factors ensuring the durability and performance of the radiation shielding concrete because the design of the radiation shielding reinforced concrete structures for NPPs is based on the bulk dry density of the concrete. Bulk density of unconsolidated shielding concrete can be calculated utilizing a test assuring to satisfy the bulk dry density, or existing credible data set. This study evaluated correlation between bulk density and bulk dry density of the concrete used for Korean NPPs (y=1.0913X-0.2458) and developed a correlation expression considering standard deviation of bulk dry density (y=1.0913X-0.3358).

  • PDF

Modeling of the Temperature-Dependent and Strain Rate-Dependent Dynamic Behavior of Glass Fiber-Reinforced Polyurethane Foams (유리 섬유 강화 폴리우레탄 폼의 온도 및 변형률 속도 의존 재료 거동 모델링)

  • Lee, Dong-Ju;Shin, Sang-Beom;Kim, Myung-Hyun
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.6
    • /
    • pp.547-555
    • /
    • 2019
  • The purpose of this study was to establish a numerical model of polyurethane foam (PUF) to simulate the dynamic response and strength of membrane-type Liquefied natural gas (LNG) Cargo containment system (CCS) under the impact load. To do this, initially, the visco-plastic behavior of PUF was characterized by testing the response of the PUF to the impact loads with various strain rates as well as PUF densities at room temperature and at cryogenic conditions. A PUF material model was established using the test results of the material and the FE analysis. To verify the validation of the established material model, simulations were performed for experimental applications, e.g., the dry drop test, and the results of FEA were compared to the experimental results. Based on this comparison, it was found that the dynamic response of PUF in dry drop tests, such as the reaction force and fracture behaviors, could be simulated successfully by the material model proposed in this study.

Experimental Study on Compaction Effect of Hydraulic Fill Soils (실내실험을 통한 수중 매립토의 다짐효과 분석)

  • Lee, Haeng-Woo;Chang, Pyoung-Wuck;Chang, Woong-Hee;Bong, Tae-Ho
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.301-310
    • /
    • 2006
  • A series of laboratory tests was carried out for analyzing compaction characteristics of hydraulic fill soils(or hydraulically filled soils). Hydraulic fill soils were settled down by the weight of soil particle itself in water and consolidated by the extraction of water from the soil structures. Water content and dry unit weight were observed as the depth of sedimentation and consolidation soil. It was found from the result that the optimum water content $(W_{cpt})$ of the maximum unit weight$(\gamma_{dmax})$ is higher than that of laboratory compaction test(KS F 2312 A method). It was due to difference in compaction energy and compaction effect between two methods. And the maximum dry unit of hydraulic fill soil is smaller than that of laboratory compaction test. Especially in terms of compaction effect, the maximum relative compaction degrees$(R_{cmax})$ of Seamangum dredged sand, river sand and mixed sand, half and half of dredged and river sands, were 85%, 91% and 86%, respectively. It means that the compaction effect can be $85\sim91%$ of the maximum unit weight in laboratory compaction test.

  • PDF

Development of Fire Extinguishing System Suitable for Unmanned Engine Room of a Small Ship (소형선박 기관실화재에 대한 자동소화시스템 개발연구)

  • Kim, Dong-Suk;Kwark, Ji-Hyun;Kang, Dae-Sun;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.20 no.3 s.63
    • /
    • pp.96-100
    • /
    • 2006
  • A study developing the dry powder fire extinguishing system inside the simulated machinery spaces of small ship was performed. Fire tests were conducted inside the compartments having volume $8m^3,\;4.5m^3\;and\;2.9m^3$ respectively. The openings and fans were established on the walls of the compartments. Diesel oil was used for the test fuel. In addition fire extinguishing nozzles using dry powder were installed downward at ceiling and horizontally at the wall or conner. All fires in the test were extinguished under system activation and there was no reignition.

Night Visibility Evaluation of Phosphorescent Road Line Markings (축광 노면표시의 야간 시인성 평가를 위한 기초 연구)

  • Lee, Yong Mun;Kim, Sang Tae;Jeong, Wang Seong;Kim, Heung Rae
    • International Journal of Highway Engineering
    • /
    • v.18 no.4
    • /
    • pp.69-75
    • /
    • 2016
  • PURPOSES : In this study, we evaluated changes in the retroreflectivity and luminance of phosphorescent road line markings with changes in glass beads and line marking thickness. METHODS : The color of line markings affects their retroreflectivity. Using a chromaticity test, we conducted the analysis of whether phosphorescent road line markings adhered to the "KS M 6080" standard. Then, we measured the dry retroreflectivity and wet retroreflectivity for various glass bead refractive indices. We conducted wet retroreflectivity test using the EN 1436 standard as the basis. We also conducted luminance tests for different glass bead refractive indices and line marking thicknesses. RESULTS : 1. Phosphorescent road line markings specimens satisfied the "KS M 6080" standard. 2. In dry retroreflectivity test, phosphorescent road line markings sprayed with glass beads satisfied the national police agency standard ($240mcd/(m^2{\cdot}Lux)$). Wet retroreflectivity test results showed that except for one type of No.1 glass beads, phosphorescent road line markings specimens sprayed with glass beads of one type of No.3 and two types of No.1 satisfied the national police agency standard ($100mcd/(m^2{\cdot}Lux)$). 3. Phosphorescent road line markings had higher retroreflectivity than non-phosphorescent road line markings in the dry condition. 4. Phosphorescent road line markings sprayed with glass beads demonstrated improved luminance. Luminance increased with higher glass bead refractive index and with increased line marking thickness. However, when the thickness crossed a certain threshold, phosphorescence ceased to increase; this is a characteristic of the phosphorescence phenomenon. CONCLUSIONS : Visibility across short distances can be ensured when phosphorescent road line markings are sprayed with glass beads, because of the retroreflection phenomenon. It is also possible to ensure far visibility using phosphorescent road line markings.

Prediction of Compaction, Strength Characteristics for Reservoir Soil Using Portable Static Cone Penetration Test (휴대용 정적 콘 관입시험을 통한 저수지 제방 토양의 다짐, 강도 특성 및 사면 안정성 예측)

  • Jeon, Jihun;Son, Younghwan;Kim, Taejin;Jo, Sangbeom;Jung, Seungjoo;Heo, Jun;Bong, Taeho;Kim, Donggeun
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.65 no.5
    • /
    • pp.1-11
    • /
    • 2023
  • Due to climate change and aging of reservoirs, damage to embankment slopes is increasing. However, the safety diagnosis of the reservoir slope is mainly conducted by visual observation, and the time and economic cost are formidable to apply soil mechanical tests and slope stability analysis. Accordingly, this study presented a predicting method for the compaction and strength characteristics of the reservoir embankment soil using a portable static cone penetration test. The predicted items consisted of dry density, cohesion, and internal friction angle, which are the main factors of slope stability analysis. Portable static cone penetration tests were performed at 19 reservoir sites, and prediction equations were constructed from the correlation between penetration resistance data and test results of soil samples. The predicted dry density and strength parameters showed a correlation with test results between R2 0.40 and 0.93, and it was found to replace the test results well when used as input data for slope stability analysis (R2 0.8134 or more, RMSE 0.0320 or less). In addition, the prediction equations for the minimum safety factor of the slope were presented using the penetration resistance and gradient. As a result of comparing the predicted safety factor with the analysis results, R2 0.5125, RMSE 0.0382 in coarse-grained soil, R2 0.4182 and RMSE 0.0628 in fine-grained soil. The results of this study can be used as a way to improve the existing slope safety diagnosis method, and are expected to be used to predict the characteristics of various soils and inspect slopes.

Effect of Semi-Dry Anaerobic Digestion Using Dairy Cattle Manure and Pig Slurry (젖소 분과 돈분 슬러리를 이용한 반 건식 혐기소화 효과)

  • Jeong, Kwang-Hwa;Kim, Jung-Kon;Lee, Dong-jun;Lee, Dong-Hyun;Jeon, Jung-Hwan
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.26 no.2
    • /
    • pp.85-93
    • /
    • 2018
  • Semi-dry anaerobic digestion experiment using dairy cattle manure collected from dairy cattle house was conducted to analyze efficiency of biogas production. As a first experiment, Biochemical Methane Potential (BMP) test was carried out according to certain ratio of sample mixtures: dairy cattle manure, pig slurry, and mixture of dairy cattle manure and pig slurry. The amount of methane accumulated during BMP test period was high in the experimental groups containing dairy cattle manure. As a second experiment, semi-dry anaerobic digestion experiment was carried out using only the dairy cattle manure collected from floor of the dairy cattle house. Judging from the experimental results, the optimum hydraulic retention time (HRT) of semi-dry anaerobic digestion for dairy cattle manure containing 13% of TS was 25 days. The amount biogas generated from the semi-dry anaerobic digestor with the TS of 13% of the dairy cattle manure ranged from 1.36~1.50v/v-d and the average was 1.44v/v-d. The optimum HRT of the semi-dry anaerobic digestor for dairy cattle manure containing TS of 15% and the semi-dry anaerobic digestor for dairy cattle manure containing TS of 17% was the same as 30 days. The amount biogas generated from the semi-dry anaerobic digestor with the TS of 15% of the dairy cattle manure ranged from 1.42~1.52v/v-d and the average was 1.47v/v-d. The amount biogas generated from the semi-dry anaerobic digestor with the TS of 17% of the dairy cattle manure ranged from 1.50~1.61v/v-d and the average was 1.55v/v-d.

Analysis of Vibration Characteristics for a Molded Dry-type Potential Transformer (몰드형 건식 계기용 변압기 진동 특성 분석)

  • Kim, Moosun;Jang, Dong Uk;Kim, Seung Mo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.209-214
    • /
    • 2017
  • Most of the present potential transformers of train vehicles are of the oil-type filled with insulating oil and are susceptible to problems such as explosion due to the increase in the internal pressure during train operation and poor reliability near the end of their life cycle. As a solution to this problem, it is necessary to develop a molded dry-type potential transformer with excellent pressure-resistance performance using insulating resin. In order to localize the product, the Korea Railroad Research Institute has been developing a molded dry-type potential transformer. As part of this research, it is necessary to analyze the vibration characteristics of the developed product and to check the transformer performance in a vibration environment. In this study, a resonance test and simulated long-term life test of the developed product were conducted according to the KS R 9144 and IEC 61373 standards, respectively, which are vibration test methods for railway vehicle parts. Their natural frequencies were analyzed by comparing the results of the numerical modal analysis and resonance test, in order to confirm their adherence to the standards. Also, the performance test after the simulated long-term life test confirmed that the operation of the developed transformer was not problematic even in a long-time vibration environment.

Eastern and Western Combined Medical Treatments on 11 Patients with Dry Eye Syndrome (안구건조증환자 11례의 한·양방 병용치료에 대한 임상보고)

  • Lee, Dong-Jin;HwangBo, Min;Seo, Hyung-Sik;Kim, Soo-Jin;Lee, Jong-Soo
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.25 no.2
    • /
    • pp.61-67
    • /
    • 2012
  • Objective : The endpoint of this trial is to verify therapeutical availability of conventional western eyedrops combined with acupuncture treatment by means of BUT(tear film break-up time), Schirmer's test, which have been considered to be typical methods for diagnosing dry eye syndrome. Methods : The subjects of this trial included the outpatients who had been diagnosed with dry eye syndrome in Pusan national university hospital and underwent acupuncture treatment from March 2011 to April 2011. They received acupuncture treatment once a week, three times while constantly using Restasis or artificial tears. We collated and analyzed the outcome data of Schirmer's test and BUT conducted at the beginning of this trial and three times more after each acupuncture treatments. Acupoints, such as, Chanjuk(BL2), Eoryo, Sajukgong(TE23), Taeyang, Sabaek(ST2), limited around both eyes were selected based on their clinical effects referring to medical books. Results : 1. From BUT test results, Restasis and acupuncture combined group showed statistically significant difference, however, artificial tears and acupuncture combined group showed difference only between before and after the treatment, which is not statistically significant. 2. From Schirmer's test results, Restasis and acupuncture combined group showed statistically significant difference, however, artificial tears and acupuncture combined group showed difference only between before and after the treatment, which is not statistically significant. 3. The average duration of treatment was statistically 16.3 days for Restasis and acupuncture combined group. Conclusions : Combination of acupuncture and Restasis for dry eye syndrome can shorten the duration of treatment. Therefore, clinical benefit is expected to be worth.

Reliability and utility of a Dry Test Bench for testing the acoustic output from a ballistic shock wave therapeutic device (탄도형 충격파 치료기의 음향 출력 시험을 위한 Dry Test Bench의 신뢰성 및 유용성)

  • Jeon, Sung Joung;Lee, Min Young;Kwon, Oh Bin;Kim, Jong Min;Choi, Min Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.5
    • /
    • pp.589-600
    • /
    • 2022
  • In order to verify the reliability of Dry Test Bench (DTB) used for testing the output energy from ballistic extracorporeal shock wave therapeutic devices, the measurements with DTB were compared with the acoustic energy measured with a Laser Doppler Vibrometer (LDV) for a commercial ballistic ESWT device. It was shown that the mechanical energy detected with DTB had variability maintained within 5 % at the same output power setting and also had a linear correlation (adj. R2 = 0.991) with the acoustic energy measured with the LDV for the entire output power settings. Using the correlation between the two methods and the correlation on the acoustic energy measured in between air and water with the LDV, the DTB measurement can be used to estimate the energy flux density in water with an average error of 7.85 % for the entire output power settings of the ballistic shock wave generator considered in the experiment. DTB provides information limited to the output mechanical energy and therefore it is not suitable for testing the various acoustic output parameters required in IEC61846 and IEC63045. However, DTB that is simple in measurement principles and easy to use is expected for manufacturers and clinical users to monitor the performance of ballistic Extracorporeal Shock Wave Therapy (ESWT) devices.