• Title/Summary/Keyword: drug-eluting stents(DES)

Search Result 17, Processing Time 0.026 seconds

Curcumin-Loaded PLGA Nanoparticles Coating onto Metal Stent by Electrophoretic Deposition Techniques

  • Nam, So-Hee;Nam, Hye-Yeong;Joo, Jae-Ryang;Baek, In-Su;Park, Jong-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.3
    • /
    • pp.397-402
    • /
    • 2007
  • Restenosis after percutaneous coronary intervention (PCI) continues to be a serious problem in clinical cardiology. To solve this problem, drug eluting stents (DES) with antiproliferative agents have been developed. Variable local drug delivery systems in the context of stenting require the development of stent manufacture, drug pharmacology and coating technology. We have worked on a system that integrates electrophoretic deposition (EPD) technology with the polymeric nanoparticles in DES for local drug delivery and a controlled release system. The surface morphology and drug loading amount of DES by EPD have been investigated under different operational conditions, such as operation time, voltage and the composition of media. We prepared poly-D,L-lactide-co-glycolic acid (PLGA) nanoparticles embedded with curcumin, which was done by a modified spontaneous emulsification method and used polyacrylic acid (PAA) as a surfactant because its carboxylic group contribute negative charge to the surface of CPNPs (?53.5 ± 5.8 mV). In the process of ‘trial and error' endeavors, we found that it is easy to control the drug loading amount deposited onto the stent while keeping uniform surface morphology. Accordingly, stent coating by EPD has a wide application to the modification of DES using various kinds of nanoparticles and drugs.

Improving Smoothness of Hydrophilic Natural Polymer Coating Layer by Optimizing Composition of Coating Solution and Modifying Chemical Properties of Cobalt-Chrome Stent Surface (코팅 용액의 조성 최적화 및 코발트-크롬 금속스텐트의 화학적 표면개질을 통한 친수성 천연 고분자 코팅층의 표면 거칠기 개선)

  • Kim, Dae Hwan;Kum, Chang Hun
    • Journal of Chitin and Chitosan
    • /
    • v.23 no.4
    • /
    • pp.256-261
    • /
    • 2018
  • Recently, the number of cardiovascular disease-related deaths worldwide has increased. Therefore, the importance of percutaneous cardiovascular intervention and drug-eluting stents (DES) has been highlighted. Despite the great clinical success of DES, the re-endothelialization at the site of stent implantation is retarded owing to the anti-proliferative effect from the coated drug, resulting in late thrombosis or very late restenosis. In order to solve this problem, studies have been actively carried out to excavate new drugs that promote rapid re-endothelialization. In this study, we introduced hydrophilic drug, tauroursodeoxycholate (TUDCA), that improves the proliferation of endothelial progenitor cells and promotes apoptosis of vascular smooth muscle cells. In addition, we utilized shellac, which is a natural resin from lac bug to coat TUDCA on the surface of the metal. When using conventional coating method including biodegradable polymers and organic solvents, phase separation between polymer and drug occurred in the coating layer that caused incomplete incorporation of drug into the polymer layer. However, when using shellac as a coating polymer, no phase separation was observed and drug was fully covered with the polymer matrix. In addition, by adjusting the composition of coating solution and modifying the hydrophilicity of the metal surface using oxygen plasma, the surface roughness decreased due to the increased affinity between coating solution and metal surface. This result provides a method of depositing a hydrophilic drug layer on the stent.

Comparison between Basic and Inverse Dual Drug and Peptide-coated Stents in a Porcine Restenosis Model

  • Jang, Eun-Jae;Lee, So-Youn;Bae, In-Ho;Park, Dae Sung;Jeong, Myung Ho;Park, Jun-Kyu
    • Applied Chemistry for Engineering
    • /
    • v.31 no.5
    • /
    • pp.502-508
    • /
    • 2020
  • Dual drug-eluting stents (DES) is a primary treatment method for coronary arterial diseases in current interventional cardiology practice. However, their pathological results according to the sequence of coating of drugs have not been reported yet. The peptide-dopamine dissolved in acetonitrile was coated onto the Chonnam National University Hospital (CNUH) stent using an electrospinning coating machine. For secondary coating (e.g., sirolimus coating, designated as SPS), sirolimus (SRL) and poly lactic-glycolic acid (PLGA) were mixed in tetrahydrofuran (THF), and the solution was then coated on the CNUH stent that had underwent the primary peptide coating using an electrospinning and spray technique. Next, the peptide-dopamine was coated on the SRL-PLGA coated stent (PSS). In this study, it was confirmed that endothelialization was promoted without being significantly affected by the coating order (SPS or PSS). The sequence of drug and peptide coating may affect the development of restenosis and PSS was effective in the prevention of restenosis compared to that of using SPS.

Prognostic Analysis of Drug-Eluting Balloon Catheter and Drug-Eluting Stent for In-Stent Restenosis of Drug-Eluting Stent (스텐트 재협착 병변에서 약물코팅 풍선카테터과 약물용출 스텐트의 예후 분석)

  • Lee, Doo Hwan;Song, Jong Nam;Park, Sin eui;Choi, Nam Gil;Han, Jae Bok;Kim, In Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.381-389
    • /
    • 2019
  • Although the development of Drug-eluting stent (DES) improved the ISR significantly more than the Bare metal stent (BMS), the coronary stent restenosis (ISR) treatment still has a high recurrence rate. This study is compared the efficacy of DEB with that of DES implantation in patients with ISR. Among 4,316 patients who underwent coronary stent implantation at the Chonnam National University Hospital between November 2012 and December 2016, 187 patients developed ISR on follow-up coronary angiography ($66.3{\pm}11.0years$, 123 males) were enrolled and divided into two groups according to revascularization method as group I (DEB group; n=127) and group II (DES group; n=60). Primary end point was defined as major adverse cardiac events (MACEs), composite of cardiac death (CD), myocardial infaction (MI), target lesion revascularization (TLR) and stent thrombosis (ST) during two-year follow-up between the two groups. There were no differences in the baseline characteristics and angiographic findings except that prevalence of device length was shorter ($21.1{\pm}5.3$ vs. $25.3{\pm}9.6 mm$, p<0.002) in group I.Two-year MACE were not different in the two groups (8.7%vs.10.0%, p=0.789). The incidences of cardiac death (0%vs.0%, p=1.000), MI (1.6%vs.6.7%, p=0.085), TLR(8.7% vs. 10.0%, p=0.789) and ST (0% vs. 0%, p=1000). DEB demonstrated comparable risk reduction for MACEs compared with DES in patients with ISR during two-year follow-up. DEB might be good alternative for the treatment of ISR in patients with ISR.

Ex vivo Morphometric Analysis of Coronary Stent using Micro-Computed Tomography (미세단층촬영기법을 이용한 관상동맥 스텐트의 동물 모델 분석)

  • Bae, In-Ho;Koh, Jeong-Tae;Lim, Kyung-Seob;Park, Dae-Sung;Kim, Jong-Min;Jeong, Myung-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.93-98
    • /
    • 2012
  • Micro-computed tomography (microCT) is an important tool for preclinical vascular imaging, with micron-level resolution. This non-destructive means of imaging allows for rapid collection of 2D and 3D reconstructions to visualize specimens prior to destructive analysis such as pathological analysis. Objectives. The aim of this study was to suggest a method for ex vivo, postmortem examination of stented arterial segments with microCT. And ex vivo evaluation of stents such as bare metal or drug eluting stents on in-stent restenosis (ISR) in rabbit model was performed. The bare metal stent (BMS) and drug eluting stent (DES, paclitaxel) were implanted in the left or right iliac arteries alternatively in eight New Zealand white rabbits. After 4 weeks of post-implantation, the part of iliac arteries surrounding the stent were removed carefully and processed for microCT. Prior to microCT analysis, a contrast medium was loaded to lumen of stents. All samples were subjected to an X-ray source operating at 50 kV and 200 ${\mu}A$ by using a 3D isotropic resolution. The region of interest was traced and measured by CTAN analytical software. Objects being exposed to radiation had different Hounsfield unit each other with values of approximately 1.2 at stent area, 0.12 ~ 0.17 at a contrast medium and 0 ~ 0.06 at outer area of stent. Based on above, further analyses were performed. As a result, the difference of lengths and volumes between expanded stents, which may relate to injury score in pathological analysis, was not different significantly. Moreover, ISR area of BMS was 1.6 times higher than that of DES, indicating that paclitaxel has inhibitory effect on cell proliferation and prevent infiltration of restenosis into lumen of stent. And ISR area of BMS was higher ($1.52{\pm}0.48mm^2$) than that of DES ($0.94{\pm}0.42mm^2$), indicating that paclitaxel has inhibitory effect on cell proliferation and prevent infiltration of restenosis into lumen of stent. Though it was not statistically significant, it showed that the extent of neointema of mid-region of stents was relatively higher than that of anterior and posterior region in parts of BMS as showing cross-sectional 2-D image. suggest that microCT can be utilized as an accessorial tool for pathological analysis.

Comparison of Efficacy of Overlapped Versus Long Eluting Stent in Acute Myocardial Infarction Patients with Diffuse Long Lesion (미만성 긴 병변이 있는 급성심근경색환자에서 긴 단일 용출 스텐트 시술과 중첩 스텐트 시술의 효과 비교)

  • Kim, Won Hyo;Kim, In Soo;Kong, Chang gi;Han, Jae Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.319-336
    • /
    • 2020
  • The purpose of this study was to compare the outcomes of two interventional methods, overlapping drug-eluting stents (DES) and long DES, for long-term clinical outcomes in patients with acute myocardial infarction (AMI). A total of 438 patients with AMI (65.9±11.0 years, 306 males) from June 2008 to March 2019 who had diffuse long coronary artery lesion, more than 30mm were divided into two groups; group I (overlapped DES group; n=140) and group II (long DES group; n=298). We compared the incidences of major adverse cardiac events [MACEs; cardiac death, myocardial infaction (MI), target lesion revascularization (TLR) and stent thrombosis (ST)] during 12 months between the two groups. Everolimus-eluting stent was more commonly used in group II than in group I (28.1% vs. 51.8% p<0.001). Mean lesion diameter was slightly longer in group II (3.1±0.3mm vs. 3.2±0.3mm, p=0.042), and prevalence of ACC/AHA lesion type C was higher in group I (41.7% vs. 25.4%, p<0.001). Incidences of MACEs during 12 months were higher in group I than group II (18.5% vs. 14.4%, p=0.034). The rates of cardiac death (2.1% vs. 4.4%, p=0.667), MI (5.0% vs. 2.7%, p=0.260) and stent thrombosis rate (0.7% vs. 1.7%, p=0.669) were similar between the two groups. However, TLR rate was higher in group I (10.7% vs. 5.6%, p=0.041). In multivariate logistic regression analysis, presence of diabetes mellitus [Hazard ratio (HR) 2.383, 95% confidence interval (CI) 1.332-4.260, p=0.003] and use of paclitaxel-eluting stent (HR) 2.367, 95% CI 1.371-4.086, p=0.002) were independent predictors of 12-month MACEs, without significant differences in prevalence between the two groups. In AMI patients with diffuse long lesion, TLR rate was higher in the overlapped DES group during 12-month follow-up. Presence of diabetes and use of paclitaxel-eluting stent were independent predictors of MACEs.

Off-pump Coronary Artery Bypass Surgery Versus Drug Eluting Stent for Multi-vessel Coronary Artery Disease (다혈관 관상동맥질환에서의 심폐바이패스를 사용하지 않은 관상동맥우회술과 약물용출 스텐트시술)

  • Lee, Jae-Hang;Kim, Ki-Bong;Cho, Kwang-Ree;Park, Jin-Shik;Kang, Hyun-Jae;Koo, Bon-Kwon;Kim, Hyo-Soo;Sohn, Dae-Won;Oh, Byung-Hee;Park, Young-Bae
    • Journal of Chest Surgery
    • /
    • v.41 no.2
    • /
    • pp.202-209
    • /
    • 2008
  • Background: The introduction of Drug Eluting Stents (DES) decreased the number of patients referred for coronary artery bypass grafting (CABG). The impact of DES on CABG (Step 1) was studied and compared with the 1-year outcome after CABG with DES (Step 2). Material and Method: Surgical results for patients who underwent off-pump CABG (OPCAB) before the introduction of DES(n=298) were compared with those who underwent OPCAB after the introduction of DES (n=288) (Step 1). Postoperative 30-day and 1-year results were also compared between the patients who underwent percutaneous coronary intervention (PCI) using DES (n=220) and those who underwent OPCAB (n=255) (Step 2). Result: Since the introduction of DES, the ratio of CABG versus PCI decreased. In the CABG group, the number of high risk patients such as elderly patients (age 62 vs. 64, p=0.023), those with chronic renal failure (4% vs. 9%, p=0.021), calcification of the ascending aorta (9% vs. 15%, p=0.043), or frequency of urgent or emergent operations (12% vs. 22%, p=0.002) increased. However, there were no differences in the cardiac death and graft patency rates between the two groups (step 1). During the one-year follow up period, the rate of target vessel revascularization (12.3% vs. 2.4%, p<0.001) and major adverse cardiac events (MACE: death, myocardial infarct, TVR) were higher in the DES than the CABG group (13.6% vs 4.3%) (stage 2). Conclusion: Introduction of DES decreased the number of patients referred for surgery, and increased the comorbidity in patients who underwent CABG. DES increased the rate of target vessel revascularization, and the occurrence of MACE during the 1-year follow-up. However, there was no difference in the incidence of myocardial infarction and cardiac death between the two groups.