• Title/Summary/Keyword: drops

Search Result 1,126, Processing Time 0.031 seconds

Rain Sensor using Scattered Light Outside Waveguide (광도파관 외부산란광을 이용한 우적감지 센서)

  • Choi, Kyoo-Nam
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.2
    • /
    • pp.22-27
    • /
    • 2011
  • Rain sensor detecting the presence of rain outside windshield glass of automobile by receiving scattered light from rain drops is proposed. Rain sensor using windshield glass as light waveguide required precision optical apparatus to inject light signal into windshield glass, and it was susceptible to outside shock and vibration, resulting malfunction, which altered optical coupling ratio. Proposed rain sensor, which detected scattered light from rain drops outside optical waveguide, did not require optical components because it did not need to inject light signal into light waveguide. This was advantageous because the sensor was less effected by shock and vibration. Fabricated rain sensor using scattered light outside waveguide responded not only to rain drops but also mist particles under simulated rain conditions using spraying nozzle, thus it showed prospects as rain sensor for automobile application.

The Holding Power of the Oil Boom Anchor (오일 펜스 Anchor의 파주력)

  • CHANG Duk Jong
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.36 no.6
    • /
    • pp.743-748
    • /
    • 2003
  • An oil boom was set up in order to contain diffused oil from spills and for the retrenchment of damage caused by oil Pollution. Therefore, the oil boom anchor needed proper holding power to endure high resistance from flowing streams and to secure the oil boom around the spill, and must dredge directly into the seabed when it is dropped and block oil outflow immediately. This study investigated the holding power of the danforth anchor and the coastal fishing vessel anchor used for oil booms in the KMPRC (Korea Marine Pollution Response Corporation). For each type, a 30 kg and 20 kg anchor were used. The holding power of the danforth anchors were measured by dropping both weights 10 times. However the coastal fishing vessel anchors were dropped only 5 times each, because no substantial differences were found between drops. In the results of the danforth anchors, an anchor awoke occurred in 2 drops of the 30 kg anchor and in 4 drops of the 20 kg anchor, wherein there was no holding power to be measured. With exception to the anchor awoke cases, the maximum holding power of the danforth 30 kg and 20 kg anchors was 250-520 kg and 123-233 kg, respectively. In the case of the coastal fishing vessel anchors of 30 kg and 20 kg, throughout the experiment, there was no occurrence of an anchor awoke. For the 30 kg and 20 kg anchors, the maximum holding power was measured to be 209-230 kg and 155-170 kg, respectively. Therefore, the holding power of the coastal fishing vessel anchor was shown to be much poorer than that of the danforth anchor. However, the holding power of the danforth anchor was very unstable. Due to the occurrences of anchor awoke, there was no holding power and the measurement value of maximum holding power showed too much variation among the drop tests. Also, after the maximum holding power was achieved, anchor awoke occurred easily. In the case of the coastal fishing vessel anchor was much more stabile, because there was no anchor awoke and no instance where holding power failed. Also the maximum holding power was reached quickly and almost no variation occurred among the drop tests.

An Experimental Investigation of the Effect of the Entrance Shape of Sudden Contraction on Single and Two-Phase Pressure Drop in Horizontal Air-Water Flow (공기와 물의 수평유동에 있어 관의 급격한 입구축소 모양이 단상 및 이상유 압력강하에 미치는 영향에 관한 실험적 연구)

  • Chun, Moon-Hyun;Baek, Joo-Seok;Park, Jong-Ryul
    • Nuclear Engineering and Technology
    • /
    • v.21 no.2
    • /
    • pp.123-133
    • /
    • 1989
  • The pressure drops through contractions in horizontal single and two-phase flow were investigated. A total of 167 measurements were made for four different entrance shapes to study the effects of the entrance shape on the pressure drop through a contraction in horizontal single and two-phase flow. From this data, pressure drops were calculated and compared with the pressure drops predicted by analytical models for single and two-phase flow. For single phase How the agreement between the data and predictions is within $\pm$25%, whereas for two-phase flow Hoopes model, which gives a better agreement than the homogeneous model, underpredicts the data as much as 45% In addition, the effects of void fraction and liquid phase mass velocity on the pressure drop through the sudden How channel contraction were investigated for two-phase flow.

  • PDF

A Voltage Drops Computation Program on Multi-Distributed Random Loads (다중 분산부하 전압강하산정 프로그램)

  • Kang, Cha-Nyeong;Kwon, Sae-Hyuk;Cho, Sung-Pil
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.2
    • /
    • pp.64-70
    • /
    • 2007
  • A voltage drop in the electrical circuit must be unavoidable. The voltage drop in the electrical circuit means a loss of heat. The heat lost would change the characteristics of the insulator and thus, the insulating performance would be towered resulting in electric leakage, electric shock, power failure, fire and other accidents. Hence, an optimized design against the voltage drop in the electrical circuit must be an important factor determining safety and economy of electrical facilities. This study analyzed the effects of voltage drop on the electrical circuit for such low-voltage electrical facilities requiring the public safety foremost and subject to multi-distributed random loads as street lamps, buildings and subway stations, and thereupon, developed an optimized voltage drop computation program to enhance safety and economy of those electrical facilities.

Testing of the Safety and the Effectiveness of Using Samjeong Pharmacopuncture Solution as Eye drops

  • Seo, Hyung-Sik;Lee, Dong-Jin
    • Journal of Pharmacopuncture
    • /
    • v.15 no.1
    • /
    • pp.23-28
    • /
    • 2012
  • Objective: This experimental study was designed to investigate the safety and the effectiveness of Samjeong pharmacopuncture solution (SPS) manufactured by using a the lowtemperature extract on process. Methods: To identify the safety and the effectiveness of using SPS as eye drops, we performed applied eye irritation tests on rabbits and antibacterial tests for Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Aspergillus niger, Fusarium oxysporum, and Candida albicans. The eye irritation test was performed according to the toxicity testing regulation of the Korea Food & Drug Administration (2009. 8. 24, KFDA 2009-116). After SPS had been applied on the left eye of the rabbits, eye irritation in the cornea, iris and conjunctiva was observed on the 1st, 2nd, 3rd, 4th & 7th day. After SPS had been dropped on bacterial species that cause keratitis, the minimum inhibition concentration and the size of the inhibition zone were measured. The anti-bacterial potency was also measured by taking the size of inhibition zone. Results: After SPS had been administered on the left eye of the rabbits, none of nine rabbits were found to show abnormal signs or weight changes. After SPS had been administered on the left eye of the rabbits, no eye irritation in the cornea, iris and conjunctiva was observed on the 1st, 2nd, 3rd, 4th & 7th day. No specific response was detected in MIC for bacterial species Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Aspergillus niger, Fusarium oxysporum, and Candida albicans after SPS had been applied. Conclusions: This study suggests that SPS is a non-toxic and non-irritant medicine that does not cause any of eye irritation in rabbits, but it has no antibacterial effects on bacterial species that are well known to cause keratitis. These results suggest that more research is required on extracts from herbal medicines for treating keratitis.

Parametric study of porous media as substitutes for flow-diverter stent

  • Ohta, Makoto;Anzai, Hitomi;Miura, Yukihisa;Nakayama, Toshio
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.2 no.2
    • /
    • pp.111-125
    • /
    • 2015
  • For engineers, generating a mesh in porous media (PMs) sometimes represents a smaller computational load than generating realistic stent geometries with computer fluid dynamics (CFD). For this reason, PMs have recently become attractive to mimic flow-diverter stents (FDs), which are used to treat intracranial aneurysms. PMs function by introducing a hydraulic resistance using Darcy's law; therefore, the pressure drop may be computed by test sections parallel and perpendicular to the main flow direction. However, in previous studies, the pressure drop parallel to the flow may have depended on the width of the gap between the stent and the wall of the test section. Furthermore, the influence of parameters such as the test section geometry and the distance over which the pressure drops was not clear. Given these problems, computing the pressure drop parallel to the flow becomes extremely difficult. The aim of the present study is to resolve this lack of information for stent modeling using PM and to compute the pressure drop using several methods to estimate the influence of the relevant parameters. To determine the pressure drop as a function of distance, an FD was placed parallel and perpendicular to the flow in test sections with rectangular geometries. The inclined angle method was employed to extrapolate the flow patterns in the parallel direction. A similar approach was applied with a cylindrical geometry to estimate loss due to pipe friction. Additionally, the pressure drops were computed by using CFD. To determine if the balance of pressure drops (parallel vs perpendicular) affects flow patterns, we calculated the flow patterns for an ideal aneurysm using PMs with various ratios of parallel pressure drop to perpendicular pressure drop. The results show that pressure drop in the parallel direction depends on test section. The PM thickness and the ratio of parallel permeability to perpendicular permeability affect the flow pattern in an ideal aneurysm. Based on the permeability ratio and the flow patterns, the pressure drop in the parallel direction can be determined.

Effect of Korean Red Ginseng supplementation on dry eye syndrome in glaucoma patients - A randomized, double-blind, placebo-controlled study

  • Bae, Hyoung Won;Kim, Ji Hyun;Kim, Sangah;Kim, Minkyo;Lee, Naeun;Hong, Samin;Seong, Gong Je;Kim, Chan Yun
    • Journal of Ginseng Research
    • /
    • v.39 no.1
    • /
    • pp.7-13
    • /
    • 2015
  • Background: Many patients with glaucoma have difficulty using antiglaucoma eye drops because of dry eye symptom. In this prospective, randomized, double-blind, placebo-controlled study, we evaluated the effect of Korean Red Ginseng on dry eye syndrome in patients with glaucoma treated with antiglaucoma eye drops. Methods: Forty-nine participants were allocated to the Korean Red Ginseng (3 g/day; n = 24) or placebo (n = 25) groups for 8 weeks. Tear film stability, fluorescein corneal staining, conjunctival hyperemia, tear production, grade of meibomian gland dysfunction, and dry eye questionnaire (Ocular Surface Disease Index) were evaluated at baseline and on completion of the treatment. Results: Almost all patients displayed dry eye symptoms and signs at baseline. After the 8-week intervention, Korean Red Ginseng supplementation significantly improved the tear film stability and total Ocular Surface Disease Index score, as compared to placebo (p < 0.01). Conclusion: Korean Red Ginseng supplementation may provide an additional treatment option for dry eye and patients with glaucoma using antiglaucoma eye drops.

Effects of the Capacitive Field in an Inductively Coupled Plasma Discharge

  • Choe, HeeHwan
    • Applied Science and Convergence Technology
    • /
    • v.26 no.5
    • /
    • pp.114-117
    • /
    • 2017
  • Plasma characteristics of two-dimensional inductively coupled discharge simulation is investigated. Impedance of an inductively coupled plasma discharge was considered. Voltage drops across antenna coils and current variation between coils made different profiles of plasma characteristics. Importance of the capacitive field effect in some case was analyzed.

Ink Jet Tools for Precision Materials Deposition

  • Creagh, Linda T.;Schoeppler, Martin W.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.811-813
    • /
    • 2005
  • Purpose-built ink jet printheads are being recognized as useful tools in manufacturing where precision deposition is required. Ink jet technology is a non-contact, non-contaminating digital process compatible with clean rooms. New manufacturing applications are driving printhead designs to smaller drops, increased productivity. This paper describes Dimatix's new tools designed to facilitate development of manufacturing processes for both rigid and flexible substrates and development of new electronic fluids.

  • PDF