• 제목/요약/키워드: drop rate

검색결과 1,332건 처리시간 0.026초

극초고압 디젤분무의 충돌면 온도거동에 관한 연구 (A Study on the Temperature Behavior on Impinging Plate of Diesel Spray with Ultra High Pressure)

  • 이종태;정대용
    • 대한기계학회논문집B
    • /
    • 제29권3호
    • /
    • pp.402-408
    • /
    • 2005
  • The instantaneous temperature behaviors on impinging plate in case of ultra high pressure have been measured and analyzed by using the instantaneous temperature probe and ultra high pressure injection equipment. The temperature drop was largest at P1 which is center of impinging spray and decreased with propagation of spray to the radius direction. The temperature drop was bigger in case of higher temperature of impinging plate. The temperature drop decreased with increase of injection pressure. But decreasing rate of temperature drop was slight over 2,500 bars. Therefore, it was predicted that the fuel evaporation versus the increase of injection pressure was maximum at around 2,500 bars.

완전 드롭형 알폼 시스템 개발 (Development on Full Drop Type Aluminium Form System)

  • 임남기
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.14-15
    • /
    • 2021
  • Even though the Al. form system, which was developed to replace the Euro-form, has been used as the slab lower formwork for almost all concrete structures based on the light weight and high conversion rate, the low-noise Drop method has been developed and used in order to overcome the limitations of the Al. Form system such as noise pollution and safety accidents caused by free fall during the demolding. However, as the low-noise drop method is still insufficient, Safety Full Drop Al. Form method is expected to be in the spotlight in the construction market based on its excellent advantages compared to the developed methods. In addition, we plan to conduct research to further contribute to securing the quality of the overall structure through continuous improvement and supplementation by introducing an automation system to the very construction method.

  • PDF

Drop formation of Carbopol dispersions displaying yield stress, shear thinning and elastic properties in a flow-focusing microfluidic channel

  • Hong, Joung-Sook;Cooper-White, Justin
    • Korea-Australia Rheology Journal
    • /
    • 제21권4호
    • /
    • pp.269-280
    • /
    • 2009
  • The drop formation dynamics of a shear thinning, elastic, yield stress ($\tau_o$) fluid (Carbopol 980 (poly(acrylic acid)) dispersions) in silicone oil has been investigated in a flow-focusing microfluidic channel. The rheological character of each solution investigated varied from Netwonian-like through to highly non-Newtonian and was varied by changing the degree of neutralization along the poly (acrylic acid) backbone. We have observed that the drop size of these non-Newtonian fluids (regardless of the degree of neutralisation) showed bimodal behaviour. At first we observed increases in drop size with increasing viscosity ratio (viscosity ratio=viscosity of dispersed phase (DP)/viscosity of continuous phase (CP)) at low flowrates of the continuous phases, and thereafter, decreasing drop sizes as the flow rate of the CP increases past a critical value. Only at the onset of pinching and during the high extensional deformation during pinch-off of a drop are any differences in the non-Newtonian characteristics of these fluids, that is extents of shear thinning, elasticity and yield stress ($\tau_o$), apparent. Changes in these break-off dynamics resulted in the observed differences in the number and size distribution of secondary drops during pinch-off for both fluid classes, Newtonian-like and non-Newtonian fluids. In the case of the Newtonian-like drops, a secondary drop was generated by the onset of necking and breakup at both ends of the filament, akin to end-pinching behavior. This pinch-off behavior was observed to be unaffected by changes in viscosity ratio, over the range explored. Meanwhile, in the case of the non-Newtonian solutions, discrete differences in behaviour were observed, believed to be attributable to each of the non-Newtonian properties of shear thinning, elasticity and yield stress. The presence of a yield stress ($\tau_o$), when coupled with slow flow rates or low viscosities of the CP, reduced the drop size compared to the Newtonian-like Carbopol dispersions of much lower viscosity. The presence of shear thinning resulted in a rapid necking event post onset, a decrease in primary droplet size and, in some cases, an increase in the rate of drop production. The presence of elasticity during the extensional flow imposed by the necking event allowed for the extended maintenance of the filament, as observed previously for dilute solutions of linear polymers during drop break-up.

개폐 각도에 따른 볼 밸브에서의 유동 해석에 관한 연구 (A Study on Flow Analysis at Ball Valve according to Opening and Shutting Angle)

  • 조재웅;한문식
    • 한국기계가공학회지
    • /
    • 제10권2호
    • /
    • pp.46-51
    • /
    • 2011
  • This study result is obtained by flow analysis according to opening and shutting angle of ball valve. As opening and shutting angle becomes larger, vortex flow becomes smaller and flow rate becomes increased. And the pressure drop is shown to be smaller at the inlet and outlet of ball. As this angle becomes larger, mass flow rate becomes increased. Its rate becomes increased abruptly in case of opening and shutting angle at more than $60^{\circ}$.This analysis result can be applied usefully with no leak at pipe system field by the optimum control of mass flow rate according to opening and shutting of ball valve.

채널 형상에 따른 마이크로채널 판형 열교환기 열전달 성능 향상에 관한 수치 연구 (Numerical Study of Heat Transfer Enhancement on Microchannel Plate Heat Exchanger with Channel Shape)

  • 전승원;김윤호;이규정
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.1888-1893
    • /
    • 2007
  • In this study, the microchannel plated heat exchanger were numerically studied for the enhancement of heat transfer in the channel configuration. Unit cold and hot fluid region with the microchannel were modeled and periodic boundary condition at the side wall was applied to continuously repeating geometry. The material of micro-structured plate is STS304 and working fluid is water. Triangular obstacles were placed in micro channel to enhance heat transfer. The performance of microchannel plated heat exchangers were numerically investigated with various obstacle configuration and Reynolds number under the parallel and counter flows. Heat transfer rate has increased about 18% compared with straight channel, but pressure drop also increased about 3.5 times. The main factor of increasing of pressure drop and heat transfer rate is considered that the momentum was lost to collide against obstacles, generation of secondary flow and boundary layer separation, wake and vortex forming phenomena.

  • PDF

큐 변화량을 이용한 적응식 AQM 성능 향상에 관한 연구 (A Study on Performance Improvement of Adaptive AQM Using the Variation of Queue Length)

  • 김종화;이기영
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.159-162
    • /
    • 2005
  • Random Early Detection (RED), one of the most well-known Active Queue Management (AQM), has been designed to substitute Tail Drop and is nowadays widely implemented in commercially available routers. RED algorithm provides high throughput and low delay as well as a solution of global synchronization. However RED is sensitive to parameters setting, so the performance of RED, significantly depends on the fixed parameters. To solve this problem, the Adaptive RED (ARED) algorithm is suggested by S. Floyd. But, ARED also uses fixed parameters like target-queue length; it is hard to respond to bursty traffic actively. In this paper, we proposed AQM algorithm based on the variation of current queue length in order to improve adaptability about burst traffic. We measured performance of proposed algorithm through a throughput, marking-drop rate and bias phenomenon. In experimentation, we raised a packet throughput as reduced packet drop rate, and we confirmed to reduce a bias phenomenon about bursty traffic.

  • PDF

용접식 판형 열교환기의 성능에 관한 실험적 연구 (Experimental study on the performance of a brazed plate heat exchanger)

  • 김종하;윤재호;권오경;김종훈;류해성;이창식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.477-482
    • /
    • 2001
  • An experimental study on the performance evaluation of a brazed plate heat-exchanger with 10RT of normal cooling capacity has been carried out. In the present study, a brazed type plate heat exchanger was tested at a chevron angle $25^{\circ}$ with refrigerant R-22. Mass flux was ranged from $23\;to\;58kg/m^{2}s$ in condensation, and from $22\;to\;53kg/m^{2}s$ in evaporation. The heat transfer coefficient and pressure drop increased with the mass flux increases. The water side pressure drop increased with the cooling water flow rate and chilled water flow rate increases, while mass flux has little affect. It is also shown that the system performance can be improved by enlarging condensation heat transfer area.

  • PDF

VOF 방법을 이용한 GMA 용접의 금속 이행에 관한 동적 해석 (II) - 단락 이행 모드의 해석 - (Dynamic Analysis of Metal Transfer using VOF Method in GMAW (II) - Short Circuit Transfer Mode -)

  • 최상균;고성훈;유중돈;김희진
    • Journal of Welding and Joining
    • /
    • 제15권3호
    • /
    • pp.47-55
    • /
    • 1997
  • Dynamic characteristics of the short circuit mode are investigated using the Volume of Fluid (VOF) method. When the initial molten drop volume, contact area and wire feed rate are given, rate change of the molten bridge profiles, pressure and velocity distributions are predicted. The electromagnetic force with proper boundary conditions are included in the formulation to consider the effects of welding current. It is found that the molten metal is transferred to the weld pool mainly due to the pressure difference caused by the curvatures in the initial stage, and electromagnetic force becomes dominant factor in the final stage of short circuit transfer. Necking occurs at the contact position between the molten drop and weld pool, and the initial molten drop volume and welding current have significant effects on break-up time.

  • PDF

Study of Optimal Location and Compensation Rate of Thyristor-Controlled Series Capacitor Considering Multi-objective Function

  • Shin, Hee-Sang;Cho, Sung-Min;Kim, Jin-Su;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권3호
    • /
    • pp.428-435
    • /
    • 2013
  • Flexible AC Transmission System (FACTS) application study on enhancing the flexibility of AC power system has continued to make progress. A thyristor-controlled series capacitor (TCSC) is a useful FACTS device that can control the power flow by adjusting line impedances and minimize the loss of power flow and voltage drop in a transmission system by adjusting line impedances. Reduced power flow loss leads to increased loadability, low system loss, and improved stability of the power system. This study proposes the optimal location and compensation rate method for TCSCs, by considering both the power system loss and voltage drop of transmission systems. The proposed method applies a multi-objective function consisting of a minimizing function for power flow loss and voltage drop. The effectiveness of the proposed method is demonstrated using IEEE 14- and a 30-bus system.

ER유체의 유동특성에 관한 실험적 연구 III (평행평판 간극내의 유량-압려강하 특성) (Experimental Investigation on the Flow Characteristics of ER Fluids III (3nd Report, Flow-Pressure Drop Characteristics clearance between Two Parallel Plate))

  • 김도태
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1999년도 추계학술대회 논문집 - 한국공작기계학회
    • /
    • pp.399-404
    • /
    • 1999
  • Electro-rheological(ER) fluids are suspensions which show an abrupt increase in rheological properties under electric fields. The rheological response is very rapid and reversible when the electric field is imposed and/or removed. Therefore, there are many practical applications using the ER fluids. The purpose of the present study is to examine the flow characteristics of electro-rheological fluids. The field-dependent yield stress are obtained from experimental investigation on the Bingham property of the ER fluid. Then the steady relationshup between pressure drop and flow rate of the ERF was two fixed parallel-plates was measured under application of an electric fields. The electrical and rheological properties of zeolite based electro-rheological fluids were reported.

  • PDF