• Title/Summary/Keyword: drinking water supply

Search Result 251, Processing Time 0.03 seconds

Improvement of effluent water quality by sludge aeration at the conventional drinking water treatment plant (정수장 슬러지 폭기를 통한 방류수 수질 개선)

  • Choi, Ilgyung;Shin, Changsoo;Beak, Inho;Lim, Jaecheol;Jeong, Chanwoo;Lee, Sungjin;Park, Jungwook
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.2
    • /
    • pp.249-255
    • /
    • 2014
  • So many drinking water treatment plants are under various difficulties by new reinforced effluent standards. Since the target turbidity, much higher than annual average, for designing sludge thickener have to be set to confront high turbidity season, the sludge at thickener should be put up for a long time during usual days. So the soluble manganese and chloroform may be formed under the anaerobic environment in the sludge thickener when the sludge retention time is longer with low turbidity. This phenomenon results in difficulties to keep regulatory level of the discharged effluent. For an effort to overcome the problems, a sludge aeration was successfully implemented into the thickening process. As a result, the final effluent quality and sludge volume were much improved; 41 % of manganese, 62 % of chloroform and 35 % of sludge volume. Additionally, effluent quality was improved ; 61 % of Manganese on aeration with pH control and we could make sure of stability effluent quality despite a long sludge retention time. We recommended the standard of installation sludge aeration equipment to nationally supply water treatment plant under effluent water quality problem ; Manganese, Chloroform, etc.

Patents Review on the Seawater Desalination Plant and Technology Using Reverse Osmosis Membrane Process (SWRO 해수담수화 플랜트 기술 관련 특허 동향 분석)

  • Cho, Jin Woo;Han, Ji Hee;Lee, Seock Heon;Sohn, Jin Sik;Yang, Jeong Seok;Kim, Dong Ha
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.3
    • /
    • pp.343-350
    • /
    • 2008
  • Many reports have warned of insufficient water supply in most countries in future and prospected providing safe and clean water become more difficult by lack of access to sustainable drinking water resources. Several facts and figures explained the impact by natural climate change and human activity results in the water scarcity and deterioration. Among many scientific solutions, the seawater desalination using a reverse osmosis membrane, so called SWRO (Seawater Reverse Osmosis) process, has been recognized as one of the most promising alternatives because of its stability and efficiency in producing large amount of drinking water from seawater through desalination by membrane filtration. Recently, in Korea, numerous researches are conducted to develop more productive and cost effective SWRO process for its wide implementation. The objective of this paper is to review the patents concerning SWRO technologies involving the plant engineering, maintenance including pretreatment of seawater and fouling control, module design, and mechanical units development for energy saving. The patents in Korea, U.S., Japan, Europe, and PCT were intensively researched and analyzed to provide the state of the art as well as leading edge technology on SWRO. This information can hopefully suggest meaningful guidelines on future research and development.

A small-scale membrane electro-dialyser for domestic use

  • Chaalal, Omar;Hossain, Md.M.
    • Membrane and Water Treatment
    • /
    • v.6 no.1
    • /
    • pp.43-52
    • /
    • 2015
  • A small-scale electro-dialysis system was constructed for domestic use. It is composed of six compartments in which five special polystyrene ionic membranes are housed. A series of experiments on the transport of sodium and chloride ions through polystyrene membranes was performed and the effects of electric current and voltage on the pH of water were investigated. This electrodialyser could reduce the NaCl content to an acceptable level (5307 mg/L) when water containing 9945 mg/L of sodium chloride is fed to the electrodialyser. The reduction was by the action of direct current 60 mA/100 mA when a 15 V / 20 V potential is maintained across the membrane. The results showed that the pH of the treated water attained a value in the range of 7-8, with the chloride concentration of 5307 mg/L when the voltage was in the range of 20 volts. This was achieved when two of the small-scale electro-dialysers were placed in series and the solutions from the respective compartments were mixed. This is considered useful because this complies to the requirement of drinking water standard both in terms of chloride and pH. Therefore, this type electrodialyserhas the potential for domestic uses in isolated houses where potable water supply is not available.

Mineral Components of Water Supply Plants and Spring Waters in Northern Gyeonggi Area (경기북부지역 정수장 및 약수터의 미네랄 성분 분포 연구)

  • Song, Hee-Il;Lim, Han-Su;Park, Gyoung-Su;Park, Hyun-Goo;Lee, Hyun-Jin;Jo, Mi-Hyun;Kim, Young-Yeon;Oh, Jo-Gyo
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.3
    • /
    • pp.238-246
    • /
    • 2019
  • Objective: The purpose of this study was to investigate the distribution of mineral components, health and taste index for water supply plants, spring water located in northern Gyeonggi area and bottled waters in market to analyze Ca, K, Mg Na, Si, $F^-$ and $SO_4{^{2-}}$. Method: The samples were source and tap water in 15 water supply plants over 9 river basin, 172 spring water and 20 bottled water. The Ca, K, Mg Na and Si were analyzed by ICP-OES. The $F^-$ and $SO_4{^{2-}}$ were determined by Ion Chromatograph. Then, taste and health index were calculated using Hashimoto equation. Results: The average concentration of major minerals showed in same order of Ca > Na > Mg > K for all kinds of drinking water from water supply plants, spring waters and bottled waters. Total concentration of major minerals (Ca, K, Mg, Na) was calculated that showed 26.79 mg/L of tap water, 21.81 mg/L of spring water, 32.94 mg/L of bottled water on average. So, the spring waters indicated the lowest minerals sum. The tap water from water supply plants was categorized to Group I, II for 33.3, 44.4% according to K-index and O-index. Otherwise, spring water was classified as Group I, II for 44.0, 46.3%. Conclusion: According to the results of K and O-index, water from water supply plant showed higher K-index which means good for the health. Otherwise, spring water indicated higher O-index that people can feel more delicious than tap water. Futhermore, the mineral distribution of source water from water supply plants and spring water had indicated high correlation with geological effect.

A Study on the Development and Improvement of Simple Piped Water Supply System in Rural Area of Korea (농촌지역 간이상수도시설 개발 및 개선에 관한 연구)

  • Chung, Yong;Koo, Ja-Kon;Kim, Myung-Ho;Yun, Suk-Woo;Kim, In-Sook
    • Journal of agricultural medicine and community health
    • /
    • v.13 no.1
    • /
    • pp.19-25
    • /
    • 1988
  • It is very important to supply safe drinking water for rural area not only a prevention of entric diseases but also a promotion of health life. It is estimated that 6,981,000 rural inhabitants were covered by the simple piped water supply system at the end of 1987 in Korea. The programme for improvement of water supply system in rural villages was initiated by the government since 1967. But most of these systems have been operated carelessly by the hands of villagers who have no proper knowledge and experience. Since most of water sources were located nearby farmland, there might be a possibility that the sources could be contaminated by pesticides and fertilizers. For this reason, it is recommended to take underground water as a water source rather than surface water such as a pond or streamwater in rural areas. However, the system is supplied from the surface water, its water quality can be improved by using of simple sand filter and simple chlorinator inexpensively. On the basis of an on-site study, conducted during 1986-87, in San-Buk Village, Keum-Sa-Myon, Yeju-Gun, Kyong-Gi-Do, the new simple piped water supply system was designed by the Institute for Environmental Research, Yonsei University, and constructed by the villagers themselves in September 1987. This simple system which is protected by metal fences consists of three main parts, pump house, vertical sand filter and water tank. The pumped water from underground flows into the upper part of the sand filter, through the sand, and out the water tank which is connected to the bottom of vertical filter. And the simple plastic-bottle chlorinator was installed in the water tank for chlorination. The water quality was remarkably improved after completion of construction. The total bacterial count was not detected from the tap water in households distributed by this simple piped water supply system. The construction cost of this system which was connected 34 households in San-Buk Village, was 4,851,000 won (approximately 6,020 U.S. dollars : 1$=805.8 won) in 1987,77% of expenses was supported by the Community Development Foundation in Korea. This case study for simple piped water supply projects will be applicable to other programme for improvement of water supply system in rural areas of Korea, and other developing countries.

  • PDF

Evaluation of Biological Activated Carbon Using Particle Counter (입자계수기를 이용한 생물활성탄 공정의 효율평가)

  • Kim, Hee gune;Ryon, Dong choon;Kim, Hyun sil;Ryu, Byung soon;Moon, Seong yong;Kim, Seung Hyun;Kim, Won Kyong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.6
    • /
    • pp.823-828
    • /
    • 2006
  • For this study, an online particle counter was installed before and after the activated carbon filtration process of D water treatment plant where has advanced water treatment processes, produces average 900,000ton/day of drinking water and supply the produced drinking water to Busan citizens. We collected and analyzed particle count data for about 1 year. We inspected particle breakthrough in three out of sixteen filter processes operated at same conditions, i.e. 5th filter, 6th filter and 7th filter. According to the monitoring results, 6th and 7th filters showed similar results while 5th filter showed different results. When compared seasonal effect, the particle count for dry season was below 10 particles/ml while the particle count for August when monthly average rainfall is over 200mm was much higher than for dry season. In January and August, there was a difference in breakthrough particle size. In January, small particles in 2~3um were mainly detected while in August 10um particles were mainly detected and the size distribution was 40% of total count.

Operating Conditions for Minimization of DBPs (Disinfection by-Products) in Drinking Water Supply System (소독부산물 최소화를 위한 운영조건 연구)

  • Shin, Hyung-Soon;Choi, Phil-Kweon;Kim, Jong-Su;Choi, Ill-Woo;Kim, Sang-Hoon;Kim, Tae-Hyun;Lee, Kyung-Hee;Lee, Soo-Moon;Jang, Eun-Ah;Jung, Yeon-Hoon;Kim, Jung-Yeol
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.3
    • /
    • pp.330-337
    • /
    • 2005
  • This study was carried out to propose the managemental improvement of the purification plants and the distribution facilities which can minimize the formation of disinfection by-products in drinking water distribution system. The disinfection by-products were highly created in the water treatment plant that the organic matters were high and the chlorine dosage was excessive. The concentration of DSPs was shown the highest value in August and the lowest value in December, because of temperature and pre-chlorine dosage effect. From the result of tracer test, the travel time from the treatment plant to the end of pipeline was around 3-4 days in summer, 5-6 days in winter, respectively, and the DSPs concentration of the reservoir(end of pipe) was 2-3 times higher than that of the beginning point. The improvement of the chlorination process and structural reformation of distribution facility was demanded to minimize the DSPs increase from purification plant to the end of pipe.

Fabrication and Characterization of Onggi Filter for Appropriate Water Treatment Technology

  • Park, Joon-Hong;Kim, Jin-Ho;Cho, Woo-Seok;Han, Kyu-Sung;Hwang, Kwang-Taek
    • Journal of the Korean Ceramic Society
    • /
    • v.54 no.2
    • /
    • pp.114-120
    • /
    • 2017
  • In underdeveloped countries, many people suffer from water shortage due to the absence of water supply service. Although water purifiers have provided support in such situations, it is not easy to maintain water filters without a continuous supply of consumable filters. To obtain a sustainable drinking water source, appropriate technology of water treatment is necessary. Herein, a low cost water purification system was developed using natural raw materials. A non-electric water treatment system was developed using filtration through an Onggi filter, which is a type of Korean traditional earthenware with a microporous surface. The porosity and flux of the prepared Onggi filter were 29.06% and 31.63 LMH, respectively. After purification of water with total dissolved solids of 10.4 mg/L and turbidity of 100 NTU, the total dissolved solids and turbidity of the water treated using the Onggi filter decreased by 12% and 99.8%, respectively.

Countermeasure to Prevent Seawater Intrusion on Coastal Area (해안지역 지하수댐 염수침입 방지기술 개선 방안)

  • 부성안;이기철;김진성;정교철;고양수
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.148-154
    • /
    • 2002
  • Groundwater Dam is one of the reliable techniques to get huge amount of groundwater abstraction for municipal, agricultural, drinking, industrial water supply system. It can be a major technique to solve water shortage problems when it based on the sufficient watershed, proper topology, and adequate aquifer distribution and pollution control. It is suggested that the two consecutive underground wall in the coastal area to prevent seawater intrusion beneath a single wall.

  • PDF

Applicability of reliability indices for water distribution networks (공급부하 시나리오에 따른 상수관망 신뢰도 지수의 적용성 분석)

  • Jeong, Gimoon;Kang, Doosun
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.7
    • /
    • pp.441-453
    • /
    • 2017
  • Water distribution networks (WDNs) supply drinking water to end users by maintaining sufficient water pressure for reliable water supply in normal and abnormal conditions. To design and operate WDNs in efficient way, it is required to quantify water supply ability of the network. Various reliability indices have been developed and applied in this field. Most of the reliability indices are calculated based on the energy within a network; that is, the total energy entered the network, the energy dissipated through water supply process, and the energy finally supplied at the nodes, etc. This study explains the energy composition in WDNs and introduces three well-known reliability indices developed based on the energy composition of the network. The three indices were applied to a study network under various demand loading scenarios that could occur in real-life operation practices. This study aimed to investigate the applicability of the reliability indices under abnormal scenarios and proposed to illustrate the spatial distribution of the system reliability in more intuitive way for proper responses to the abnormal situations.