• 제목/요약/키워드: drinking water

검색결과 2,102건 처리시간 0.036초

건강위해성 평가에 의한 정수용 수처리제의 불순물 관리 기준 설정 방법에 관한 연구 (A Study on the Management Criteria of Chemiclas Impurities for Drinking Water Treatment by Risk Assessment)

  • 정용;백영석;권동식;이기공;강형석
    • 한국물환경학회지
    • /
    • 제20권5호
    • /
    • pp.432-436
    • /
    • 2004
  • The principle and methodology of risk assessment was applied to establish the quality standard of potential impurities of drinking water treatment chemicals. The impurities(arsenic, lead, cadmium, chromium, mercury, etc.) are regulated as the contained quantity of chemicals in Korea while they are regulated as the quality standard with the idea of 10% of the national safety drinking water standard in U.S.A(NSF) and Japan(JWWA). According to risk assessment of the current standard implemented in Korea, the excess cancer risk of arsenic and lead were determined in around $10^{-5}$ and the hazard quotient(HQ) of cadmium and chromium were below $10^{-2}$, respectively. And the standard concentration of the impurities are regulated as much as 2%~6% of the national drinking water quality standard. The values are more enforced rather than the standards in U.S.A(NSF) and Japan(JWWA) regulating the concentration of impurities the 10% of the national drinking water quality standard. We conclude that the impurities standard of drinking water treatment chemicals should be reconsidered comprehensively concerning the national safety drinking water quality standard and risk assessment.

음용수질의 안정성을 위한 부식지수제도의 도입 (Introduction of Corrosion Index System for Stability of Drinking Water Quality)

  • 김영관;김진근
    • 상하수도학회지
    • /
    • 제25권5호
    • /
    • pp.707-717
    • /
    • 2011
  • Replacement of old water distribution pipes for protecting water quality induced by pipe corrosion requires enormous budget. Even after the replacement, however, corrosion can occur again at any times and, therefore, inhibitive measure of the corrosion will be not only economical but needed to diminish the consumers' distrust on tap water quality. In 2008, National Environmental Research Institute did a survey on 8 major drinking water source and proposed to establish the Langelier Saturation Index(LI) as a corrosion index in Drinking Water Quality Criteria. Among the water industries of Korea, K-Water is the only one that set up the level of pH over 7.0 and LI above -1.5 on yearly average basis. However, no systematic regulation including LI to inhibit the corrosive tendency has been established yet. In this paper, LI values out of 31 drinking water treatment plants were analyzed and two-stage control of LI value as a measure of corrosive tendency of water is proposed. Primarily, water treatment facilities may operate the system at a target LI value below -1.5. Following the investigation on the effect caused by adjusting the LI value on water quality and corrosiveness, it will be desirable to improve LI value below -1.0 in the long run. In addition to the LI, supplemental use of Larson's modified ratio (LMR) which incorporates hydraulic detention time will be necessary. Several methods to prove the inhibitive effect of improving the LI value on water quality have been also suggested.

국내 소사육농가의 자가용 가축음용수 오염실태 평가조사 (Contamination status of groundwater used as livestock drinking in beef and dairy cattle farms, Korea)

  • 장양호;이수진;김효비;이정학;이만호;길혜경;최농훈
    • 대한수의학회지
    • /
    • 제51권1호
    • /
    • pp.47-53
    • /
    • 2011
  • In Korea, groundwater is main water source in livestock farms. Most dairy and cattle farms have constructed their own wells for human drinking and livestock farming. However, these private residential wells have not been controlled by government and also there was scant study about livestock drinking water quality. Therefore this study was to monitor of the livestock farms' groundwater quality in Korea. Water samples were collected at 123 dairy and cattle farms and were analysed forty six substances with quality standard for drinking water approved by the Minister of Environment. Seventy eight (63.4%) of 123 samples failed to drinking water stand a test. The most frequent contaminants were nitrate-nitrogen and microbial. 22.8% (n=28) of samples showed nitrate-N concentration of higher than 10 mg/L meant that can't be used drinking water for human and the Nitrate-N concentration analysed in the range of 0.2 to 61.2 mg/L. All of 78 failed to drinking samples had microbial problems, especially 5.7% (n=7) of samples indicated water could be contaminated by feces. Other contaminants detected were zinc and evaporation residue. Especially detected zinc concentration (32 mg/L) was about ten times higher than standard of zinc (3 mg/L). Regression analysis indicated that groundwater pH did not influence to nitrate-N concentration but the hardness and chloride could affect to nitrate-N concentration in the groundwater. Most livestock farms were adjacent to crop farmland in Korea. This could cause contamination of groundwater with nitrate-N and pesticide that could accumulate livestock product. Moreover Heavy metal such as zinc and copper could be released from a corrosive plated water pipe in livestock farm. Put together, Korea livestock system is indoor, not pasture-based, hence livestock could be exposed to potential contaminated water consistently. Therefore on the basis of these data, appropriate livestock drinking water quality standards should be prepared to keep livestock healthy and their product safe. Further, livestock drinking water quality should be monitored continuously in suitable livestock drinking water standards.

음용수의 변이원성에 관한 조사연구 (Study on the Mutagenicity of Drinking Water)

  • 박지인;유춘만;위인선
    • 한국환경보건학회지
    • /
    • 제24권2호
    • /
    • pp.68-73
    • /
    • 1998
  • This is a study on the risk assessment of drinking water using mutagenicity testing. The tests have been carried with the raw water, treated water, and drinking water (tap water) in Kwangju and Mokpo areas. The Ames preincubation test was carried concentrating samples using by Sep-Pak PLUS cartriges in Salmonella typhimurium TA100 and TA98. The samples were tested with several chemical water quality analysis. The THMs have not been measured in raw water, but measured treated water and tap water at a value of 7.135-12.473 $\mu$g/l. It was observed that the number of revertants colonies increased in treated water and tap water on TA100 without S9 and showed weak mutagenicity on TA98 without S9. Indirect mutation was not seen in TA100 and TA98 with S9. The results indicated that formed substances of treatment process's of water that increased mutagenicity.

  • PDF

상수도관로의 부식 방지를 위한 수돗물의 침식성 평가 (Evaluation on the Aggressivity of Drinking Water for Corrosion Control in Water Distribution System)

  • 곽필재;이현동;남상호
    • 상하수도학회지
    • /
    • 제11권1호
    • /
    • pp.53-63
    • /
    • 1997
  • The corrosion problems in water distribution system are reduced by decreasing the agressivity of drinking water which is evaluated by marble test and saturation indices(LSI or CCPP etc.). Marble test is a reliable method to determine the actual saturation condition of treated water. This study was done to determined the aggressivity of tap water and the effectiveness of $Ca(OH)_2$ and NaOH dosage for corrosion control. The drinking water in Seoul were evaluated by marble test and Langelier Index(LSI) and Calcium Carbonate Precipitation Potential(CCPP). The results indicated that the drinking water in Seoul were undersaturated as Calcium Carbonate($CaCO_3$). The LSI and CCPP of the water treated with $Ca(OH)_2$ were higher than that of water treated with NaOH. Therefore, to increase the Alkalinity and Calcium Hardness for corrosion control in water distribution system, $Ca(OH)_2$ is more effective than NaOH.

  • PDF

춘천지역 일부 주민들의 먹는물 중 미량금속 및 무기 음이온에 대한 노출 (Exposure of Selected Chuncheon Residents to Trace Metals and Inorganic Anions in Drinking Water)

  • 김희갑;송진아;송병열
    • Environmental Analysis Health and Toxicology
    • /
    • 제24권4호
    • /
    • pp.293-301
    • /
    • 2009
  • This study was conducted to investigate the distribution of the concentrations of selected trace metals and inorganic anions in five types of drinking water samples (mineral spring water, well water, small community water, municipal tap water, and commercial mineral water) collected from Chuncheon, Gangwon-do in 2007. Forty four samples were analyzed for five metals and five anions using an atomic absorption spectrometer and an ion chromatograph, respectively. Arsenic (As) and nitrate (${NO_3}^-$) concentrations in some groundwater samples did not meet the future (10 ${\mu}g/L$) and current (44 mg/L) Korean drinking water standards, respectively. On the other hand, any municipal tap water samples, the sources of which were lake surface water, satisfied the Korean standards. Human health risk assessment results showed that arsenic in all types of water, especially groundwater including commercial mineral water, may pose both noncarcinogenic and carcinogenic effects on the residents. It is concluded that groundwater is not safe drinking water any longer and that a national survey and follow-up measures need to be taken.

폭염 하에서 음수 내 비타민 C와 트리메칠글리신 공급이 오리의 혈액 매개변수 및 생산성에 미치는 효과 (Effects of drinking water containing trimethyl glycine or ascorbic acid on growth performance and blood parameter in ducks under scorching heat wave)

  • 강환구;박병성
    • 한국응용과학기술학회지
    • /
    • 제33권3호
    • /
    • pp.411-420
    • /
    • 2016
  • The objective of this study was to determine the effect of drinking water containing trimethyl glycine or ascorbic acid on growth performance and blood parameter profiles of duck exposed to scorching heat stress. A total of 480 ducks were randomly assigned to the following eight experiment groups for 42 days : control group C with general water, treatment group 1 (T1) with drinking water containing 100 ppm ascorbic acid, treatment group 2 (T2) with drinking water containing 200 ppm ascorbic acid, treatment group 3 (T3) with drinking water containing 300 ppm ascorbic acid, treatment group 4 (T4) with drinking water containing 400 ppm trimethyl glycine, treatment group 5 (T5) with drinking water containing 800 ppm trimethyl glycine, treatment group 6 (T6) with drinking water containing 1,200 ppm trimethyl glycine, treatment group 7 (T7) with electrolytes of KCl (0.5%) + $NaHCO_3$ (1.0%)+NaCl (0.5%). Our results revealed that the body weights and feed intakes of treatment groups, especially T3 and T6, were increased compared to the control group, where as the feed conversion ratios of treatment groups were decreased (p<0.05). Blood levels of total cholesterol, triglyceride, LDL-C, glucose, AST, ALT and pH in treatment groups were lower compared to those in the control group (p<0.05). Blood levels of red blood cell, platelets profiles, electrolyte and gas in treatment groups were higher compared to those of the control group (p<0.05).

서울시민의 수돗물 인식과 실태파악을 통한 수돗물음용 활성화 연구 (Study on the Tap Water Drinking Promotion with Analysis of Current Status in Seoul Citizen)

  • 허정림;최경희;박석순
    • 한국환경교육학회지:환경교육
    • /
    • 제24권4호
    • /
    • pp.78-93
    • /
    • 2011
  • Clean and safe water is the fundamental element for the good life of people. However, expanding the distrust on the tap water increased the anxiety on drinking water and accelerated the growth of the natural and purified water market. In this respect, this study was made to find an opportunity to invigorate the use of the Seoul tap water for drinking by means of assessing the awareness of the citizen and the current condition on the tap water in Seoul. The findings were that the direct use of the tap water for drinking was very low and 'use after boiling' was also lower relative to 'use of purified water'. Also, the education on the environment should include the importance of the use of the tap water to improve the awareness of the citizen on the tap water and the administrative role, typically for educational institutes and schools, might be required to increase the use of the tab water for drinking.

  • PDF

수돗물 병입수 중 염소소독부산물 및 aldehyde의 발생 특성 (Characteristics of Chlorination Byproducts and Aldehyde Occurrence in Bottled Tap Water)

  • 이연희;박주현;김현구;안경희;김태승;김동훈;권오상
    • 한국물환경학회지
    • /
    • 제28권5호
    • /
    • pp.754-761
    • /
    • 2012
  • Several drinking water treatment plants (DWTPs) produce the bottled tap waters (BTWs) as pilot production and provide them for noncommercial use. In 2008, acetaldehyde and chloral hydrate were detected in some BTWs and the public worry over the safety of the water. In this study, the BTWs produced from 7 DWTPs were tested for 13 chemicals including disinfection byproducts (DBPs). The level of four trihalomethanes (THMs) were increased up to 15 days. The average concentration of them was 0.0075 mg/L at the time of bottling and it was increased to 0.0214 mg/L after 15 days. The average acetaldehyde concentration was 0.0406 mg/L at the time of bottling but it was went up to 0.2251 mg/L after 11 days and then decreased. Although the initial concentrations of DBPs were below the drinking water standard, we also traced them at different storage conditions. Temperature affected the formations of THMs and acetaldehyde concentrations significantly. While the average concentration of THMs ranged from 0.0113 to 0.0182 mg/L at $25^{\circ}C$, it was increased to 0.0132 ~ 0.0256 mg/L at $50^{\circ}C$. In case of acetaldehyde, concentration ranged from 0.0901 to 0.2251 mg/L at $25^{\circ}C$, it was increased to 0.3394 ~ 1.0591 mg/L at $50^{\circ}C$. Throughout the tests with 7 BTWs samples, none of the chemicals was exceeded the drinking water standard of Korea. Therefore, it is recommended to avoid the exposure of BTWs to sunlight or high temperature during distribution and storage.

우리나라와 외국 5개국의 수질 관련법 및 기준 비교 (Comparison about Law Related Water Pollution and Drinking Water Standards in Korea and Five Other Countries)

  • 신경주
    • 한국주거학회논문집
    • /
    • 제5권2호
    • /
    • pp.109-117
    • /
    • 1994
  • The purpose of this study was to investigate the difference in water law and drinking water standards in Korea and five other countries. The documentary research method was used for this study and the Dong-A newspaper(1920-1993), journal and book related water pollution law were used as an analysis data. The results can be summarized as follow: 1. Law related water pollution in Korea was legislated last and characterized by frequent law revision in comparison with other countries. 2. Drinking water standards in Korea was strict in standard item and standard value.

  • PDF