• 제목/요약/키워드: drift ratio

검색결과 366건 처리시간 0.02초

Determination of torsional irregularity in response spectrum analysis of building structures

  • Aliakbari, Fatemeh;Garivani, Sadegh;Shahmari, Ali
    • Structural Engineering and Mechanics
    • /
    • 제74권5호
    • /
    • pp.699-709
    • /
    • 2020
  • Torsional irregularity is one of the most probable types of horizontal irregularity and existence of this irregularity in most of the structural loading codes is determined by calculating the ratio of the maximum to the average story drift. No specific method has been previously recommended by the codes to calculate the mentioned ratio in the response spectrum analyses. In the current investigation, nine steel building structures with different plan layouts and number of stories have been analyzed and designed in order to evaluate the efficiency of three methods for calculating the ratio of the maximum to the average story drift in the response spectrum analyses. It should be noted that one of these methods is the approach used by current version of ETABS software andother ones are proposed in this paper. The obtained results using the proposed methods are compared with the time history analysis results. The comparisons show that one of these methods underestimates the mentioned ratio in all studied models, however, the other two methods have shown similar results. It is also found that the plan layouts and irregularities can affect how these methods estimate the ratios compared to those obtained by the time history analysis. Generally, it can be concluded that all of these methods can properly predict the ratio with acceptable errors.

더블앵글로 접합된 골조의 수평처짐 (Story Drift of a Frame with Column Flange Bolted-Beam Web Welded Double Angle Connections)

  • 양재근;김호근;김기환
    • 한국공간구조학회논문집
    • /
    • 제3권3호
    • /
    • pp.95-103
    • /
    • 2003
  • Frame is one of the most commonly used structural systems for the resistance of applied loads. Many researchers have recently conducted their studies to investigate the effect of several parameters such as the connection flexibility, boundary condition of each support, beam-to-column stiffness ratio. These parameters play important roles on the characteristic behavior of frames. A simplified spring model is proposed to obtain the story drifts of frames with various beam-to-column connection stiffnesses in this research. A point bracing system with adequate spring stiffness is also suggested to establish the relationship between the applied load and the resisting translational spring stiffness within the limit state of story drift.

  • PDF

교류변환형 트란지스터식 직류증폭회로에 관한 연구 (The study of a chopper-type transistorized d.c. amplifier circuit)

  • 한만춘;최창준
    • 전기의세계
    • /
    • 제18권5호
    • /
    • pp.12-19
    • /
    • 1969
  • The sensitivity of transistorized d.c. amplifiers is mainly limited by drift at operating point caused by ambient temperature changes. A chopper-type transistorized amplifier is necessary to obtain a high sensitivity without recourse to drift compensation which requires the adjustment of several balancing controls. A chopper-stabilized system consisting of an electro-mechanical chopper for input and output and a high-gain a.c. amplifier is designed and analyzed. The gain of the a.c. amplifier, expressed as the ratio of voltages, is larger than 80db in the band of 50C/S - 100KC/S. The complete system gives an open-loop gain of 68db at direct current. The offset voltage is 20.mu.V referred in input and the voltage drift at the input is less than 10.mu.V/hr at 25.deg.C. This type of amplifier would be useful for the high-gain transistorized d.c. amplifier for analog computers. Also, due to the high input impedance, it is suitable for amplification of signals from wide range of source impedances.

  • PDF

Seismic response of dual structures comprised by Buckling-Restrained Braces (BRB) and RC walls

  • Beiraghi, Hamid
    • Structural Engineering and Mechanics
    • /
    • 제72권4호
    • /
    • pp.443-454
    • /
    • 2019
  • In order to reduce the residual drift of a structure in structural engineering field, a combined structural system (dual) consisting of steel buckling-restrained braced frame (BRBF) along with shear wall is proposed. In this paper, BRBFs are used with special reinforced concrete shear walls as combined systems. Some prototype models of the proposed combined systems as well as steel BRBF-only systems (without walls) are designed according to the code recommendations. Then, the nonlinear model of the systems is prepared using fiber elements for the reinforced concrete wall and appropriate elements for the BRBs. Seismic responses of the combined systems subjected to ground motions at maximum considered earthquake level are investigated and compared to those obtained from BRBFs. Results showed that the maximum residual inter-story drift from the combined systems is, on average, less than half of the corresponding value of the BRBFs. In this research, mean of absolute values of the maximum inter-story drift ratio demand obtained from combined systems is less than the 3% limitation, while this criterion has not been fulfilled by BRBF systems.

Nonlinear finite element modeling of the self-centering steel moment connection with cushion flexural damper

  • Ali Nazeri;Reza Vahdani;Mohammad Ali Kafi
    • Structural Engineering and Mechanics
    • /
    • 제87권2호
    • /
    • pp.151-164
    • /
    • 2023
  • The latest earthquake's costly repairs and economic disruption were brought on by excessive residual drift. Self-centering systems are one of the most efficient ways in the current generation of seismic resistance system to get rid of and reduce residual drift. The mechanics and behavior of the self-centering system in response to seismic forces were impacted by a number of important factors. The amount of post-tensioning (PT) force, which is often employed for the standing posture after an earthquake, is the first important component. The energy dissipater element is another one that has a significant impact on how the self-centering system behaves. Using the damper as a replaceable and affordable tool and fuse in self-centering frames has been recommended to boost energy absorption and dampening of structural systems during earthquakes. In this research, the self-centering steel moment frame connections are equipped with cushion flexural dampers (CFDs) as an energy dissipator system to increase energy absorption, post-yielding stiffness, and ease replacement after an earthquake. Also, it has been carefully considered how to reduce permanent deformations in the self-centering steel moment frames exposed to seismic loads while maintaining adequate stiffness, strength, and ductility. After confirming the FE model's findings with an earlier experimental PT connection, the behavior of the self-centering connection using CFD has been surveyed in this study. The FE modeling takes into account strands preloading as well as geometric and material nonlinearities. In addition to contact and sliding phenomena, gap opening and closing actions are included in the models. According to the findings, self-centering moment-resisting frames (SF-MRF) combined with CFD enhance post-yielding stiffness and energy absorption with the least amount of permeant deformation in a certain CFD thickness. The obtained findings demonstrate that the effective energy dissipation ratio (β), is increased to 0.25% while also lowering the residual drift to less than 0.5%. Also, this enhancement in the self-centering connection with CFD's seismic performance was attained with a respectable moment capacity to beam plastic moment capacity ratio.

MOS Transistor를 이용한 착동증폭기 (MOS Transistor Differential Amplifier)

  • 이병선
    • 대한전자공학회논문지
    • /
    • 제4권4호
    • /
    • pp.2-12
    • /
    • 1967
  • MOS 전계효과 transistor를 이용하여 직류착동증폭기를 설계하여 A 정도의 극미소직류전류를 측정하는 장치에 관한 연구이다. 등가회로를 이용하여 전압이득과 동상전압변별비를 주는 식을 유도하였으며 유효등가 source 저항을 대단히 높이기 위한 정전류원회로의 실현을 위한 해석을 하였다. 전압이득은 6.6, 상온에서의 drift는 하루에 1.5mv 정도이고 동상전압변별비는 최고 84db 이었다. 이것은 MOS transistor의 대단히 높은 입력저항의 특징을 살려 전잡상등에서 나오는 극미소직류전류의 측정을 간단하게 할 수 있게 하는 것이다.

  • PDF

헌치를 이용하여 보강된 RC 보-기둥 외부접합부의 반복이력 특성 (Hysteresis Characteristics of RC Exterior Beam-Column Joint Retrofitted with Haunch)

  • 이영욱;박형권
    • 한국지진공학회논문집
    • /
    • 제21권3호
    • /
    • pp.115-123
    • /
    • 2017
  • To investigate the cyclic characteristics of the retrofitted exterior joints of RC frame with haunch, 70% scaled 6 beam-column exterior joint subassemblies were designed according to design guideline according to 1988 and tested with cyclic loading up to 3.5% story drift ratio. During the experiments axial forces are applied to columns to simulate gravity load. Experimental results shows that the strength of retrofitted specimens was increased steadily until 2.5% story drift ratio and their strengths increased more than 1.7 times of the non-retrofitted in case that main bar was bent away from exterior joint. The joint strength and effective stiffness of the retrofitted specimen was increased and results in more deformation capacity compared to the non-retrofitted.

벽식 아파트 구조에서 연결부재의 거동특성을 고려한 비선형 동적 응답 (Nonlinear Dynamic Response of Well-Slab Apartment Building Considering The Behavior of Coupling Elements)

  • 김기현;장극관;서대원;천영수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.437-442
    • /
    • 2002
  • The purpose of this study is to investigate nonlinear behavior and estimate ultimate resistance of the wall structure against seismic loading. Experimental data for RC coupling elements are used for specifying the strength deterioration and stiffness degradation factor of hysteretic model. Modified coupling element models are used in the push over analysis and time history analysis. In the time history analysis, three earthquake waves are used in the analysis and their peak ground accelerations are changed to be 0.2g. The conclusions of this study are as follows : (1) In the push over analysis, yielding of coupling elements occurred at lower story with small story drift ratio as 0.3%. (2) In the time history analysis, the story drift ratio is sufficient for the requirement of Korean Code, But coupling elements at most stories of the buildings occurred yielding. i. e. the earthquake resistant capacity of shear wall structures is not sufficient at 0.2g.

  • PDF

Experimental study on seismic performances of steel framebent structures

  • Liang, Jiongfeng;Gu, Lian S.;Hu, Ming H.
    • Earthquakes and Structures
    • /
    • 제10권5호
    • /
    • pp.1111-1123
    • /
    • 2016
  • To study seismic performance of steel frame-bent structure, one specimen with one-tenth scale, three-bay, and five-story was tested under reversed cyclic lateral load. The entire loading process and failure mode were observed, and the seismic performance indexes including hysteretic loops, skeleton curve, ductility, load bearing capacity, drift ratio, energy dissipation capacity and stiffness degradation were analyzed. The results show that the steel frame-bent structure has good seismic performance. And the ductility and the energy dissipation capacity were good, the hysteresis loops were in spindle shape, which shape were full and had larger area. The ultimate elastic-plastic drift ratio is larger than the limit value specified by seismic code, showing the high capacity of collapse resistance. It can be helpful to design this kind of structure in high-risk seismic zone.

초고층 건물골조 시스템의 내진설계상 문제점 (Problems in Seismic Design of High-Rise RC Building Frame Systems)

  • 이한선;정성욱;고동우
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2005년도 학술발표회 논문집
    • /
    • pp.195-202
    • /
    • 2005
  • High-rise residential buildings in these days tend to adopt a building frame system as primary earthquake resisting structural system for some architectural reasons. But there exist several ambiguities in designing such building frame systems according to current codes, with regards to : the effective stiffness property of RC cracked section in static and dynamic analyses, analytical model to evaluate story drift ratio and, deformation compatibility requirements of frames. The comparative study for these issues by appling IBC 2000 and KBC 2005 to a typical building frame system shows that demands of member strength and story drift ratio can be different significantly depending on designer's interpretation and application of code requirements.

  • PDF