• Title/Summary/Keyword: drainage performance

Search Result 232, Processing Time 0.022 seconds

A Comparative Study on the Spacing and Discharge Performance of Subsurface Drainage Culvert to Increase Drainage Efficiency (배수효율이 높은 지하암거의 간격과 주름유공관의 통수능 비교분석)

  • KIM, Hyuntai;RYU, Jeonyong;JUNG, Kiyuol;PARK, Youngjun
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.6
    • /
    • pp.67-72
    • /
    • 2019
  • This study compared the theory of a culvert spacing and analytical results of the seepage flow for the subsurface drainage. i) If culvert spacing (Sc) is within 5 m, the unit drainage (q) is very larger; in contrast, if Sc is 5 m or more, there is very little drainage in the middle between drains. Therefore, the drain spacing should be within 5 m to ensure high drainage efficiency. ii) Since the planned culvert drainage increases linearly with the soil's permeability coefficient (k), k must be taken into account when determining the drain diameter by the planned culvert drainage. iii) As a result of analyzing the drainage performance of the absorbing culvert, the drainage performance is sufficient with the diameter of the corrugated drain pipe Dc = 50 mm at the length of the drain Lc = 100 m. iv) Therefore, if the drain spacing (Sc) is less than 5 m using the low-cost non-excavated drainage pipe method (${\Phi}50mm$ the corrugated drain pipe and fiber mat) rather than the conventional trench drain method (Sc > 10 m, Dc > 100 mm), uniform and high drainage efficiency can be ensured as well as low construction cost. v) The sub-irrigation+drainage culvert requires narrower drain spacing (Sc < 2-3 m) for irrigation. As a result of examining the condition of 35 mm in diameter (Dc) and 2~3 m in drain spacing, it is possible to apply the non-excavated drainage pipe method to the sub-irrigation+drainage culvert because drainage performance is sufficient at the drain length Lc = 50 m.

Comparisons of Drainage Performance on Coarse Grained Soils with Regard to Horizontal Drainage Type (조립질 지반에서의 수평배수재 종류에 따른 배수성능 비교)

  • Teawan Bang;Wanjei Cho;Seunghwan Seo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.11
    • /
    • pp.25-31
    • /
    • 2023
  • Horizontal drainage, which are representative dewatering method of domestic and foreign slope, are applied to reducing pore water pressure. Accordingly, several previous studies have been conducted, but horizontal drainage are standardized which is an unclean standard for a quantity calculation in filed. Therefore, this study presents field soil and laboratory model box to identify a drainage performance and influencing factors of various horizontal drainage. Furthermore, this study verifies the performance comparison of drainage shape or size according to different particle size distributions. In the outflow results for steady state, the study found that all samples are drained at a constant rate after a minimum of 3 minutes to maximum of 15 minutes. In the case of comparing the outflow per hour (Unit flux) in coarse grained soils, it found that drainage shape and size affect drainage performance. In the result, the future expected to be used basic data that experiment of drainage performance on fine grained soils and determine the quantity.

Drainage system for leakage treatment of cement concrete structure in underground (콘크리트 지하구조물 누수 처리를 위한 유도배수시스템)

  • Kim, Dong-Gyou
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.4
    • /
    • pp.573-585
    • /
    • 2019
  • The objective of this study is to propose the drainage system that has been improved the workability, waterproofing and drainage performance to treat the leakage from the cement concrete structures in underground. It is improved that the pipe for conveying ground leak in the existing drainage system had the problem in workability and waterproof. The drainage systems with the improved pipe for conveying ground leak were constructed in conventional concrete lining tunnels to evaluate the workability, waterproofing and drainage. The waterproof and the drainage performance of the drainage system was evaluated by injecting 1,000 ml of red water in the back of the drainage system at 3 weeks, 6 weeks, 9 weeks, 11 weeks, 14 weeks, 17 weeks and 23 weeks. During 6 months of field performance test, the average daily temperature of the tunnel site was measured from $-12.4^{\circ}C$ to $19.7^{\circ}C$. The daily minimum temperature was $-17.2^{\circ}C$ and the daily maximum temperature was $26.7^{\circ}C$. There was no problem in waterproof and drainage performance on the pipe for conveying ground leak and the drainage system during 6 months for field performance test. It is concluded that the improved drainage system can be applied to various cement concrete underground structures where leakage occurs, and has little seasonal effect.

Evaluation of the Performance of One-way Drainage Filter by Field Test (시험시공을 통한 일방향 배수필터의 성능 평가)

  • Seo, Dong-Uk;Kim, Hyeon-Tae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.4
    • /
    • pp.47-53
    • /
    • 2012
  • It is needed to install a one-way drainage filter to prevent a seepage from lake or river outside of embankment and to promote a drainage from a flood inside of embankment when dikes such as lake dike, river dike, etc are constructed. However, the results of research for one-way drainage filter are insufficient. Therefore, through the field test of one-way drainage filter, this study checked a function of one-way drainage filter with a test of performance. As a result of field test, water flow in dike was blocked in the interception direction of the section that one-way drainage filter was installed, but water passed to the flow allowance direction of the section. Therefore we confirmed the function of one-way drainage filter. Seepage quantity in the flow allowance direction of the one-way drainage filter section was low as 74.6~80.5 % than that in the section without installation of filter because of a reduction effect of seepage with filter. And seepage quantity of field test was low as 64.3~90.0 % than that in results of seepage analysis because the coefficient of permeability of embankment in field is different from the results of laboratory test. In the future, more study will be needed to solve several problems which are related to fix the filter on slide, durability of filter, etc.

Performance evaluation of a subsurface drainage culvert system in converted paddy fields

  • Do, Jong Won;Park, Jongseok;Kim, Hyuntai;Lee, Kwangya;Shin, Hyungjin
    • Korean Journal of Agricultural Science
    • /
    • v.47 no.2
    • /
    • pp.263-273
    • /
    • 2020
  • With the change of the agricultural environment (increased rice production, decreased rice consumption, and rice production policies), converting paddy fields into upland fields is an increasing trend. In terms of conversion into upland fields, subsurface drainage is one of the most important factors for good field crop growth. This study evaluates the performance of a subsurface drainage culvert system in paddy fields and reclaimed lands. The obtained results are briefly summarized as follows: 1) After a comparative evaluation of several subsurface drainage culvert systems, including excavated subsurface drainage and non-excavated subsurface drainage types, type 3 (non-excavated, perforated drain pipe 50 mm, filter mat B50 cm, subsoiling 70 cm and culvert spacing 5 m) shows relatively high values among four types in terms of effectiveness (subsurface discharge capability) and economic efficiency (construction cost). 2) Type 3 has proven that it is suitable for design standards of discharge capacity through field tests performed in paddy fields (three sites: Gong-geom, Gae-san, Juk-san) and reclaimed lands (two sites: Gum-ho, Mi-am). 3) In the experiment of Sesamum indicum growth according to the existence of a drainage system, Sesamum indicum growth with a subsurface drainage culvert system had good value in terms of plant shoot and root length, shoot fresh and dry weight, and root fresh and dry weight).

Advanced Retention and Drainage Technology Offers Improved Performance and Operational Cost Savings

  • Freeman William L.
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2006.06b
    • /
    • pp.239-243
    • /
    • 2006
  • Papermaking has changed remarkably during the past 20 years, creating huge pressures on retention and drainage programs. During this time, technology has advanced from single PAM flocculants to inorganic microparticle-based programs and then to micropolymer-based programs. In today's evolving fine paper market, retention and drainage programs have to meet increased demands in many areas, such as increased speed, GAP formers, dilution headboxes, higher ash levels, reduced furnish quality, lower cost, and increased machine efficiency. Hercules recently introduced a new technology that offers performance and stability improvements and operational cost savings as compared to existing advanced technologies. $PerForm(R)$ SP Advanced Retention and Drainage Technology consists of a family of products based on a structured organic particulate that offers papermakers the ultimate flexibility for management of wet end chemistry. This paper compares $PerForm(R)$ SP Advanced Retention and Drainage Technology to inorganic microparticle and micropolymer technologies and provides multiple case histories on machines that demonstrate the benefits of the technology. In these case histories, the PerForm SP is shown to provide improved retention and drainage that results in improved performance and operational cost savings to the mill.

  • PDF

A Study on the Evaluation Criteria of Drainage Performance by Measurement of Horizontal Drainage Flow Rate by Damage Degree by Interior Model Construction Experiment (실내 모형토조실험에 의한 손상도별 수평배수공 유출량 측정을 통한 배수성능 평가 기준 제안)

  • Suhwan Choi;Donghyuk Lee;Jeonghoon Shim
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.1
    • /
    • pp.45-50
    • /
    • 2023
  • In order to prevent slope disasters caused by rainfall, it is very important to quickly exclude rainfall. In Korea, horizontal drainage holes with excellent economic feasibility and construction performance are generally applied as a method to lower the underground water level. However, horizontal drainage holes constructed on the site are often uniformly constructed regardless of the presence or absence of other water or ground conditions, and it is often difficult to expect drainage performance of horizontal drainage holes due to poor maintenance. In this study, an artificial ground was created using model construction and horizontal drainage experiments were conducted to measure the amount of horizontal drainage drain in a certain amount of control area 0%, 25%, 50%, 75%, and an evaluation table (draft) that can quantitatively evaluate horizontal drainage based on measurements and design documents is proposed as basic data.

Performance of Horizontal Drainage in the Slope Using Numerical Analysis (수치해석을 이용한 비탈면 수평배수공의 성능 분석)

  • Sangyun Kim;Hoki Ban
    • Journal of the Korean GEO-environmental Society
    • /
    • v.25 no.8
    • /
    • pp.5-11
    • /
    • 2024
  • Due to the high proportion of mountainous terrain in Korean territory and the concentration of heavy rainfall during the summer season, concerns arise about the potential decrease in slope stability caused by rainfall. Installing slope drainage facilities mitigates the rise in groundwater levels due to infiltration, thus enhancing slope stability. Horizontal drains, classified as auxiliary facilities among drainage systems, lack established installation standards and related research. Slopes with installed horizontal drains have been confirmed to exhibit higher safety factors compared to those without. Furthermore, the safety factor of mimicking horizontal drains by increasing the permeability coefficient of the surrounding ground was compared with that of the conventional simulation method using the Drain function. As a result of the comparison, it was confirmed that the installation length showed better drainage performance than the installation angle in the drainage performance of the horizontal drainage hole, and it was judged that the installation length was a more important factor.

Field Application of Permeable Polymer Concrete Pipe for Drainage (집.배수용 투수성 폴리머 콘크리트 관의 농업 수리시설물의 현장적용)

  • 민정기;연규석;성찬용
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.6
    • /
    • pp.136-143
    • /
    • 2003
  • This study is performed to evaluate performance of the developed pipe when using for underground drainage in fm land, the efficiency of the pipe is examined such as quantity of drainage, water temperature and other field performance in all weather condition. Results of this study, the higher permeability through wall of the pipe is achieved by making various size pores using open-graded aggregate. And in all weather conditions, permeable polymer concrete pipe perform much better than conventional perforated pipes. During rice farming period, quantity of drainage the permeable polymer concrete pipe is 1.25 time greater than conventional perforated pipes. Therefore, use of the permeable polymer concrete pipe is greater advantages when considering collecting and draining capacity compared with conventional perforated pipes.

Improvement of existing drainage system for leakage treatment in exiting underground structures (운영중인 지하구조물의 누수처리를 위한 유도배수공법의 개선)

  • Kim, Dong-Gyou;Yim, Min-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.4
    • /
    • pp.669-683
    • /
    • 2017
  • The objective of this study is to propose a modification of the previously proposed drainage system for catching the partial leakage of underground concrete structures. Two techniques were proposed for applying the drainage system only to the leaking parts. One was for conveying leaking groundwater to the collection point in the drainage system and the other was for conveying the collected groundwater to the primary drainage system of the underground concrete structure. Four waterproofing materials for conveying leaking groundwater to the catchment point of the drainage system, Durkflex made of porous rubber material, KE-45 silicone adhesive with super strong adhesion, Hotty-gel made of polymeric materials and general silicone adhesive were evaluated for waterproofing performance. Hotty-gel only showed perfect waterproof performance and the other three waterproof materials leaked. The modified drainage system with Hotty-gel and drainage pipe with fixed saddle to convey the leaking groundwater from the catchment point to the primary drainage system were tested on the concrete retaining wall. The waterproof performance and the drainage performance were evaluated by injecting 1,000 ml of water in the back of the modified drainage system at the 7-day, 14-day, 21-day, 28-day, 2-month and 3-month. There was no problem in waterproof performance and drainage performance of the modified drainage system during 3 months. In order to evaluate the construction period and construction cost of the modified drainage system, it was compared with the existing leaching repair method in surface cleaning stage, leakage treatment stage, and protective barrier stage. Total construction period and construction cost were compared in considering the contents of work, repair material, construction equipment, working time, and total number of workers. As a result of comparing and analyzing in each construction stage, it was concluded that the modified drainage system could save construction period and construction cost compared to the existing leaching repair method.