• Title/Summary/Keyword: drainage discharge

Search Result 300, Processing Time 0.019 seconds

Transition of Pumping Technology, Irrigation Water Requirement, and Unit Area Drainage Discharge at Pumping Station-based Irrigation Associations in South Korea during Japanese Colonial Period (in Review) (일제하 양배수장형 수리조합에서의 양수기술과 단위용·배수량의 변천 (리뷰 논문))

  • Kim, Jin Soo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.63 no.3
    • /
    • pp.59-73
    • /
    • 2021
  • The purpose of this study is to investigate transition of pumping technology, irrigation water requirement, and unit area drainage discharge at the Pumping station-based Irrigation Associations (PIAs) in South Korea during Japanese colonial period (1910-1945). The PIAs established pumping stations and embankments along rivers for the purpose of irrigation, drainage and flood prevention until the mid-1920s. From the late 1920s after major river improvement projects, newly established PIAs did not include the flood prevention in their purpose of establishment. The design criteria of the irrigation and drainage projects, such as irrigation water requirements, design rainfall, and allowable ponding duration were decided according to the circumstances of PIAs. The gross irrigation water requirement of paddy fields increased from the 1920s to the 1940s, and reached the level of 0.0020 m3/s/ha (19 mm/d) in the 1940s for the fairly good irrigation status in the drought. The great floods of 1930, 1933, and 1934 triggered the increase in drainage discharge in the late 1930s, leading to the unit area drainage discharge of 0.9-2.6 m3/s/km2 for natural drainage and 0.3-1.1 m3/s/km2 for pump drainage. Therefore, several PIAs near the major rivers could avoid repetitive floods damage.

Study on the Characteristics of Gravity Drainage for Geotextiles by Model Tests (모형실험에 의한 지오텍스타일의 중력배수 특성 연구)

  • 이상호;권무남
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.38 no.4
    • /
    • pp.125-136
    • /
    • 1996
  • In order to investigate the characteristics of gravity drainage for geotextile, small-scale model tests for the geotextile chimney drain of earth dam which is a typical type of gravity drainage were carried out using 15 kinds of nonwoven and composite geotextiles. According to the results of this study, the drainage discharge of geotexgile drain generally increases with exponential function as hydraulic head increases and the increasing rate is greater in the coarser soil of dam material. It has a trend to increase when the construction slope of geotextile drain is steeper and the number of layers of geotextile is more. The relationship between the transmissivity of geotextile and the drainage discharge has positive correlation and the rate of increase is greater in the coarser soil. The geotextile products must be carefully selected in consideration of transmissivity of geotextile when the soil to be drained is coarser and the seepage flow is relatively high. Most of staple fiber nonwoven geotextile used in this study are found to be appropriate for drainage purpose. Among them, the composite geotextile the type of which geotextile is evaluated to be the most excellent material. But the geotextile of low permeability such as filament thermal bonded and filament spunbonded nowovens closely examined their transmissivity especially to be used for drainage function.

  • PDF

A Study on the Characteristics of Pressure Drainage for Geotextiles by Laboratory Model Tests (모형실험에 의한 지오텍스타일의 압력배수 특성 연구)

  • 이상호;권무남
    • Geotechnical Engineering
    • /
    • v.12 no.5
    • /
    • pp.89-102
    • /
    • 1996
  • In order to investigate the characteristics of pressure drainage for geotextile, small-scale model tests were carried out for the horizontal and vertical geotextile drain to accelerate consolidation of foundation under embankment for the purpose of foundation reinforcement. According to the result of this study, the accumulative drainage discharge is found to increase as compressive stress of geotextile increases with logarithmic function. The drainage discharge under each step of compressive stress linearly increases with the increase of hydraulic head and its increasing rate is smaller when the compressive stress is higher. The drainage discharge shows to be greater when the number of geoteztile layers is more and the foundation material is finer. The relationship between transmissivity of geogextile and drainage discharge has positive correlation and the rate of increase is appeared to be the same regardless of foundation material and hydraulic head. And it proves that the drainage capacity of geotextile drain is determined by the transmissivity of geoteztile.

  • PDF

Characteristics of Pollutants Concentrations at Paddy Field Areas during Irrigation Periods (관개기 광역논에서의 오염물질의 농도 특성)

  • 김진수;오승영;김규성;권순국
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.43 no.6
    • /
    • pp.163-173
    • /
    • 2001
  • This study describes the characteristics of concentrations of pollutants such as total nitrogen(T-N), total phosphorous(T-P), and chemical oxygen demand(COD) at paddy areas during 2-year irrigation periods. The most common order in average concentrations of T-P and COD is podded water > irrigation(or drainage) water > percolated water. Most of pollutants concentrations in drainage water are lower than those in irrigation water after early July due to large uptake of pollutants by rice crop and denitrification. The exponential L (load)-Q(discharge) equations for classified irrigation periods are significant at 0.001 level for irrigation and drainage waters. For drainage water, the concentrations of T-N and COD slightly decrease with discharge, while the T-P concentrations slightly increase with discharge.

  • PDF

Characteristics of Pollutant Loading from Paddy Field Area with Groundwater Irrigation (지하수 관개지역 논에서의 배출부하 특성)

  • 윤춘경;김병희;전지홍;황하선
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.44 no.5
    • /
    • pp.116-126
    • /
    • 2002
  • Discharge pattern and water quality were investigated in the drainage water from about 10 ha of groundwater-irrigated paddy field in the growing season of 2001. Total discharge quantity was about 1,117.2 mm in which about 75% was caused by management drainage due to cultural practice of paddy rice farming and the rest by rainfall runoff where total rainfall was about 515 mm. Dry-day sampling data showed wide variations in constituent concentrations with average of 26.14 mg/L, 0.37 mg/L, 3.54 mg/L at the inlet, and 43.60 mg/L, 0.34 mg/L, 3.58 mg/L at the outlet for CO $D_{cr}$ , T-P, and T-N, respectively. Wet-day sampling data demonstrated that generally CO $D_{cr}$ followed the discharge pattern and T-P was in opposite to the discharge pattern, but T-N did not show apparent pattern to the discharge. Discharge and load are in strong relationship. And based on regression equation, pollutant loads from groundwater irrigation area are estimated to be 288.34, 1.17, and 5.45 kg/ha for CO $D_{cr}$ , T-P, and T-N, respectively, which was relatively lower than the literature value from surface water irrigation area which implies that groundwater irrigation area might use less irrigation water and result in less drainage water, Therefore, total pollutant load from paddies irrigation with groundwater could be significantly lower than that with surface water. This study shows that agricultural drainage water management needs a good care of drainage outlet as well as rainfall runoff. This study was based on limited monitoring data of one year, and further monitoring and successive analysis are recommended for more generalized conclusion.

A Study on Drainage Performance of Domestic Plastic Board Drains and Recovery of Discharge Capacity by Vacuum Effect (국내 PBD재의 배수성능과 진공효과에 의한 통수능력 향상에 관한 연구)

  • 박영목
    • Geotechnical Engineering
    • /
    • v.13 no.2
    • /
    • pp.39-54
    • /
    • 1997
  • Laboratory testings were carried out on plastic board drains (PBDs) using large scale test apparatus to evaluate the physical properties and the drainage performance. The test results reveal that the domestic products of PBDs are well compared with the foreign prod acts as far as the quality and drainage performance are concerned. It has also been confirmed that the discharge capacity decreases with time in such a way that the air bubbles are entrapped inside kinky PBDs and these air bubbles block the water flow through PBDs. It has been found that the vacuum pressure iseffectively applicable to recover the discharge capacity affected by the entrapped air bubbles.

  • PDF

An Analysis of Flood Mitigation Effect Applying to LID in Mokgamcheon Watershed using SWMM Model (SWMM 모형을 이용한 목감천 유역의 LID 시설 적용 홍수저감효과 분석)

  • Jang, Yeongsun;Mun, Sungho;Yang, Sunglin
    • International Journal of Highway Engineering
    • /
    • v.15 no.3
    • /
    • pp.75-83
    • /
    • 2013
  • PURPOSES: In this study, flood mitigation effect of drainage asphalt concrete pavement were analyzed by a SWMM 5.0 program in order to evaluate the low impact development (LID) based on the drainage asphalt concrete pavements. METHODS: In order to determine the porosity parameters of drainage asphalt concretes, the specimen mixtures were manufactured using the conditions presented in the previous study. The numerical simulation was conducted using the SWMM 5.0 program considering the flood mitigation effect of drainage asphalt concrete pavements. The effect of flood reduction can be observed when drainage asphalt concrete pavements were applied to Mokgamcheon watershed. The flood mitigation effect analysis of Mokgamcheon watershed as well as continuous simulation of subwatershed runoff were performed through this study. RESULTS : The analysis of drainage asphalt concrete pavements was carried out for evaluating the effect on runoff, resulting in: the peak flow decreases up to 1.26~9.53% after drainage asphalt concrete pavements applied in the SWMM 5.0 program furthermore, the discharge decreases up to 0.55~4.11%. CONCLUSIONS: As a result, the reduced peak flow and discharge were found through the SWMM 5.0 program. It can be concluded that the flood is effectively reduced when the drainage asphalt concrete pavements are used.

Comparative Study on the Runoff Process of Granite Drainage Basins in Korea and Mongolia

  • Tanaka, Yukiya;Matsukura, Yukinori
    • The Korean Journal of Quaternary Research
    • /
    • v.17 no.2
    • /
    • pp.79-84
    • /
    • 2003
  • This study revealed the differences in runoff processes of granite drainage basins in Korea and Mongolia by hydrological measurements in the field. The experimental drainage basins are chosen in Korea (K-basin) and Mongolia (M-basin). Occurrence of intermittent flow in K-basin possibly implies that very quick discharge dominates. The very high runoff coefficient implies that most of effective rainfall quickly discharge by throughflow or pipeflow. The Hortonian overlandflow is thought to almost not occur because of high infiltration capacity originated by coarse grain sized soils of K- basin. Very little baseflow and high runoff coefficient also suggest that rainfall almost does not infiltrate into bedrocks in K-basin. Flood runoff coefficient in M-basin shows less than 1 %. This means that most of rainfall infiltrates or evaporates in M-basin. Runoff characteristics of constant and gradually increasing discharge imply that most of rainfall infiltrates into joint planes of bedrock and flow out from spring very slowly. The hydrograph peaks are sharp and their recession limbs steep. Very short time flood with less than 1-hour lag time in M-basin means that overland flow occurs only associating with rainfall intensity of more than 10 mm/hr. When peak lag time shows less than 1 hour for the size of drainage area of 1 to 10 km2, Hortonian overland flow causes peak discharge (Jones, 1997). The results of electric conductivity suggest that residence time in soils or weathered mantles of M-basin is longer than that of K-basin. Qucik discharge caused by throughflow and pipeflow occurs dominantly in K-basin, whereas baseflow more dominantly occur than quick discharge in M-basin. Quick discharge caused by Hortonian overlandflow only associating with rainfall intensity of more than 10 mm/hr in M-basin.

  • PDF

Comparative Study on the Subsurface Drainage Discharge Performance by the Type of Non-Excavation Subsurface Drainage Culvert (비굴착 지하배수암거 형태별 지하배수 성능 비교분석)

  • Kim, Hyuntai;Ryu, Jeonyong;Jung, Kiyuol;Seo, Donguk
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.6
    • /
    • pp.73-81
    • /
    • 2018
  • In this study, subsurface discharge performance has been studied through theoretical seepage analysis on four types of culverts that can be installed under the condition of non-excavation, such as (a)perforated pipe(${\Phi}50mm$), (b)perforated pipe+horizontal mat (B50cm) (c)perforated pipe+horizontal mat+vertical gravel(B<10cm), (d)perforated pipe+vertical gravel(B<10cm), and existing typical type (e)perforated pipe with gravel (B40, h=40cm) which can be installed by excavation. The analysis results were as follows. i) Subsurface discharge performance per unit (m) was (a)type 56%, (b) 91%, (c) 96%, (d) 76%, respectively, lower than the value of (e)culvert. ii) However, considering that non-excavation culvert can be installed at a spacing of 5m with the installation cost of the existing excavation culvert at the interval of 10m, it was analyzed that unit subsurface discharge(q) of (a)20.2mm/day(110%), (b)32.8(178%), (c)34.6(188%) (d)27.5(149%) in the four types of non-excavation culvert installed at intervals of 5m under the condition of $ k=10^{-4}cm/s$ was much larger than the amount of (e)type 18.5(100%), existing excavation culvert installed at 10m interval. iii) Through the test construction, peak subsurface drainage discharge($q_p$) was 38.4mm/day, which is larger than the value of design criteria and confirmed that it satisfies the analysis results as well. iv) In particular, it was evaluated that (b)perforated pipe+horizontal mat(B50cm) are low cost, high efficiency subsurface drainage culvert type with sufficient drainage performance(178%).

Evaluation on Drainage Capacity of Cylindrical Drain with Different Core Shapes (코아형식에 따른 원통형 배수재의 구멍막힘에 의한 배수능력 평가비교)

  • Lee Kwang-Yeol;Nugroho David Setiawan;Yun Sung-Tae;Ji Ho-Yeol
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.311-315
    • /
    • 2006
  • Various core shapes of cylindrical drains are used for accelerating primary consolidation for soft clay deposits, but serious harmful disadvantages on drainage capacity may occur on cylindrical drains due to confining Pressure when they are installed in that soil. In this study, two different core shapes of cylindrical drain are used to evaluate the drainage capacity with consideration of clogging effects on their filter jackets for an applied confining pressure. Column tests with radial drainage system were conducted under confining pressure of 50 kPa for 13 days. Two parameters which are discharge and accumulated volume of water drained were measured as the time elapsing. From this experimental study, the results showed that at the Initial stage before the clogging developed enough, the cylindrical drain with angular-type-plastic-core could produce discharge twice higher (maximum) than those with round-type. After 13 days had passed on, cylindrical drain with angular-type-plastic-core could produce discharge only 20% higher than those with round-type one. Eventually, there is a possibility that the efficiency of using angular-type-cylindrical-drain will be similar to the round-type one as the clogging develops more.

  • PDF