• 제목/요약/키워드: downwind area

검색결과 52건 처리시간 0.022초

완주지역의 VOCs 배출특성에 따른 공단지역과 일반지역의 기여도 분석 (VOCs Emission Characteristics and Mass Contribution Analysis at Wanju Industrial Area)

  • 김득수;양고수;박비오
    • 한국대기환경학회지
    • /
    • 제24권5호
    • /
    • pp.562-573
    • /
    • 2008
  • Concentrations of volatile organic compounds (VOCs) measured from the local industrial sources in Wanju industrial complex during June $2007{\sim}January$ 2008. The samples were collected from the primary sources (6 emission points) in 4 major factories in Wanju industrial complex as well as two general sources in Wanju County to elucidate the abundances of speciated VOCs and their spacial and temporal distributions depending on source bases. Industrial sources are as follows; fabricated metal manufacture, motor vehicle manufacture, rubber and plastic manufacture, and chemical manufacture factories. Two general source samples were collected from gasoline gas station and dry cleaning shop in urban area. In order to understand the near source influence at receptor, samples from the two receptor sites (one is at center of the industrial complex and the other site is at distance residential area downwind from the center) were collected with sample canister, and analyzed by using GC/MSD. The concentrations from different sources were compared and discussed. The mass contributions of the speciated VOCs to total VOCs measured from industrial sources and ambient ai r at two receptors were presented and discussed.

우리나라의 SAR능력 향상에 관한 연구 -해난사고 분석 및 Leeway 현장실험- (A Study on the Improvement of SAR Capabilities in Korea -Analysis of marine casualties and leeway field experiment-)

  • 윤종휘;이문진;장하룡;고성정
    • 해양환경안전학회지
    • /
    • 제7권2호
    • /
    • pp.13-22
    • /
    • 2001
  • We studied the characteristics of marine casualties within the area under control of Korea National Maritime Police and leeway of drifting vessel. According to 5 years'(1995~1999) data of casualties, it was found that the occurrence of casualties by fishing boats ranked the highest and a considerable numbers of casualties took place more than 20 miles off the shore. From a result of field experiment of G/T 50 tons vessel off Busan harbor on Apr. 26~28, 2000, we computed that the linear equation of leeway speed(cm/s) was 1.01$\times$U(U : wind speed in m/s)+11.36 with correlation coefficient between wind speed and leeway speed being 0.252 and we found leeway angle range from $+87^{\circ}$(right) to $-78^{\circ}$(left ) of the downwind direction.

  • PDF

都市地域의 垂直, 水平 擴散係數 算定 (Evaluation of the Horizontal and Vertical Dispersion Coefficients for the Urban Area)

  • ;;;이석조
    • 한국대기환경학회지
    • /
    • 제2권1호
    • /
    • pp.23-31
    • /
    • 1986
  • Meteorological Measurement was performed for evaluation of the horizontal vertical standard deviation $(\sigma_y, \sigma_z)$, surface roughness length and stmospheric stability during the period of March to October 1985 The major results are as follows; 1) The average value of surface roughness length was 144cm at NEPI. 2) In frequency distribution of atmospheric stability, neutral state (D class) was dominent in Seoul (29%) and Pusan (30%). Unstable states (A. B. C. class) were 26% in Seoul and 24% in Pusan. Also, stable states (D. E. F class) were 74% in Seoul and 76% in Pusan. 3) Standard deviations of horizontal ad vertical direction were evaluated as a function of downwind distance and atmospheric stability at NEPI, Jamsil and Pujeondong (Pusan). Standard deviation of horizontal direction was largest at NEPI among 3 areas because of mechanical turbulence resulting from difference of surface roughness length.

  • PDF

점오염원의 대기확산에 관한 민감도 분석과 모델링 (The Sensitivity Analysis and Modeling for the Atmospheric Dispersion of Point Source)

  • 이화운;원경미;배성정
    • 한국환경과학회지
    • /
    • 제9권1호
    • /
    • pp.57-64
    • /
    • 2000
  • The sensitivity analysis of two short-term models (ISCST3, INPUFF2.5) is performed to improve the model accuracy. It appears that the sensitivities on the changes of wind speed, stack height and stack inner diameter in the near distance from source, stability and mixing height in the remote distance form source, are significant. Also the gas exit velocity, stack inner diameter, gas temperature and air temperature which affect the plume rise have some effects on the concentration values of each model within the downwind distance where final plume rise is determined. And in modeling for the atmospheric dispersion of point pollutant source INPUFF2.5 can calculate amount, trajectory of puff and concentration versus time at each receptors. So, it is compatible to analyze distribution of point pollutants concentration at modeling area.

  • PDF

회전익 항공기 공중살포 특성 측정 (Measuring the characteristic of aerial spray by rotary wing)

  • 임세훈;송병흠
    • 한국항공운항학회지
    • /
    • 제17권1호
    • /
    • pp.46-51
    • /
    • 2009
  • This paper presents results from field studies carried out to monitor off-target droplet movement of endosulfan insecticide applied to the Korea chestnut tree area. As a results, mean airborne drift values were recorded 25m as average from downwind of a single flight line(sample line) in mountain terrain and mean effective swath width was recorded 19.5m as average in a plain. In terms of characteristics of geography of Korea aerial application is mainly carried out in mountain terrain. The equipment, weather conditions, and appropriate aerial spray technic are required for effective aerial application. In particular, the pilot can get effective results when he only sprays with consideration of environment factors since there is much turbulence in mountain terrain. Eventually, the most effective factor of droplets drift is to estimate the local weather conditions exactly.

  • PDF

양산시 산업단지에서 측정한 악취물질의 농도 분포 특성 및 대기확산 모델링 (Characteristics of Malodor Pollutants and Their Dispersion Measured in Several Industrial Source Regions in Yangsan)

  • 송상근;손장호;김유근;박흥재
    • 한국환경과학회지
    • /
    • 제18권10호
    • /
    • pp.1103-1114
    • /
    • 2009
  • In this study, the environmental behavior of malodor pollutants (MPs: $H_2S$, $CH_3SH$, DMS, and DMDS) was investigated around areas influenced by strong anthropogenic processes based on observations and modeling study (a CALPUFF dispersion model). The MP emission concentrations were measured from 8 industrial source regions (tire plants (S1-S3), waste water disposal plant (S4), and oil refinery (S5) in an urban center area and paper mill/incineration plant (S6) and livestock feedlots (S7-S8) in Ungsang area) in Yangsan city during a fall period in 2008 (21 October 2008). Overall, the most MPs emitted from the urban center area were found to affect the malodor pollution in their downwind areas during early morning (06:00 LST) and nighttime (18:00 and 21:00 LST), compared with those in the Ungsang area. For malodor intensity, the most MPs in the urban center area (especially S1 and S2) were found to be a significant contributor, whereas $CH_3SH$ and $H_2S$ in the Ungsnag area (especially S6) were the dominant contributor. The model study showed agreement in the spatial distributions of simulated MPs with those of the observations. The largest impact of MPs in the urban center area on the malodor pollution in its residential areas occurred at S1, S2, and S3 sites during nighttime, while that of MPs in the Ungsang area occurred at S6 and S8 sites. This may be caused mainly by the high MP emissions and in part by wind conditions (prevailing northeasterly winds with low wind speeds of 2-3 m/s).

통합모델을 활용한 이류와 도시비율이 서울 수도권 지역의 도시열섬강도에 미치는 영향 분석 (Analysis of the Effects of Advection and Urban Fraction on Urban Heat Island Intensity using Unified Model for Seoul Metropolitan Area, Korea)

  • 홍선옥;김도형;변재영;박향숙;하종철
    • 대기
    • /
    • 제29권4호
    • /
    • pp.381-390
    • /
    • 2019
  • This study investigates the impacts of urban land-use fraction and temperature advection on the urban heat island intensity over the Seoul metropolitan area using the UM (Unified Model) with the MORUSES (Met Office Reading Urban Surface Exchange Scheme) during the heat wave over the region from 2 to 8, August 2016. Two simulations are performed with two different land-use type, the urban (urban simulation) and the urban surfaces replaced with grass (rural simulation), in order to calculate the urban heat island intensity defined as the 1.5-m temperature difference between the urban and the rural simulations. The land-use type for the urban simulation is obtained from Korea Ministry of Environment (2007) land-use data after it is converted into the types used in the UM. It is found that the urban heat island intensity over high urban-fraction regions in the metropolitan area is as large as 1℃ in daytime and 3.2℃ in nighttime, i.e., the effects of urban heat island is much larger for night than day. It is also found that the magnitude of urban heat island intensity increases linearly with urban land-use fraction. Spatially, the estimated the urban heat island intensities are systematically larger in the downwind regions of the metropolitan area than in the upwind area due to the effects of temperature advection. Results of this study indicate that urban surface fraction in the city area and temperature advection play a key role in determining the spatial distribution and magnitude of urban heat island intensity.

전주공단지역의 주요VOCs 배출농도 측정 및 배출원별 특성 분석 (Measurement of VOCs Concentrations at Jeonju Industrial Area and Emission Characteristics)

  • 김득수;양고수;박비오
    • 한국환경과학회지
    • /
    • 제16권3호
    • /
    • pp.299-310
    • /
    • 2007
  • It will be necessary to make proper management plans to preserve the air quality in good level for the public. In order to make these plans, source information and detail emission inventories of the city and near industrial areas should be given. However, lack of the source measurements data makes us more difficult to complete the source inventory. VOC source Inventory could be utilized for the feasibility study to estimate the contribution of VOC sources presenting to the receptor such as residential area. It may give policy maker an idea how to control the air quality, and improve their social environment in the area. This study shows data that measured VOCs concentrations from the local industrial areas in Jeonju during from May 2005 to January 2006. The samples were collected from the near sources in 7 major factories in the industrial park as well as 5 general sources in near city Jeonju area to elucidate the abundances of speciated VOCs and their spacial and temporal distributions depending on source bases. Industrial sources are as follows; chemical, food, paper, wood, metal, non-metal (glass), and painting (coating) industries. The 5 general sources are sampled from tunnel, gasoline gas station, dry cleaning shop, printing (copy) shop, and road pavement working place in urban area. To understand the near source effect at receptor, samples from the 2 receptor sites (one is at center of the industrial complex and the other site is at distance residential area downwind from the center) were collected and analyzed for the comparison to source concentration. The mass contributions of the speciated VOC to total mass of VOCs measured from the different sources and ambient (2 receptors) were presented and discussed.

장애물 외관비가 주변 흐름에 미치는 영향 (The Effects of Obstacle Aspect Ratio on Surrounding Flows)

  • 김재진
    • 대기
    • /
    • 제17권4호
    • /
    • pp.381-391
    • /
    • 2007
  • The characteristics of flow around a single obstacle with fixed height and varied length and width are numerically investigated using a computational fluid dynamics (CFD) model. As the obstacle length increases, flow distortion near the upwind side of the obstacle increases and the size of the recirculation zone behind the obstacle also increases. As the obstacle width increases, the size of the recirculation zone decreases, despite almost invariable flow distortion near the upwind side of the obstacle. Flow passing through an obstacle is separated, one part going around the obstacle and the other crossing over the obstacle. The size of the recirculation zone is determined by the distance between the obstacle and the point (reattachment point) at which both the flows converge. When the obstacle width is relatively large, flows are reattached at the obstacle surface and their recoveries occur. Resultant shortening of the paths of flows crossing over and going around decreases the size of the recirculation zone. To support this, the extent of flow distortion defined based on the change in wind direction is analyzed. The result shows that flow distortion is largest near the ground surface and decreases with height. An increase in obstacle length increases the frontal area fraction of flow distortion around the obstacle. In the cases of increasing the width, the frontal area fraction near the upwind side of the obstacle does not change much, but near the downwind side, it becomes larger as the width increases. The frontal area fraction is in a better correlation with the size of the recirculation zone than the building aspect ratios, suggesting that the frontal area fraction is a good indicator for explaining the variation in the size of the recirculation zone with the building aspect ratios.

슬레이트 지붕의 설치년도와 면적에 따른 공기 및 유출 빗물 중의 석면 농도 (Asbestos Concentrations in Ambient Air and Drained Rainwater from Slate Roofing by Construction Year and Roof Area)

  • 장봉기;류제영;탁현욱;송수진;이종화;이강호;최재호
    • 한국산업보건학회지
    • /
    • 제23권3호
    • /
    • pp.196-204
    • /
    • 2013
  • Objectives: The purpose of this study is to analyze the number and influence factors of asbestos fibers in the air of farmhouses with asbestos cement slate roofing, as well as in rainwater per unit area of the asbestos cement slate roofing. Methods: At a distance of 1 m from the end of asbestos cement slate roofing in 20 farmhouses, the asbestos fiber in the air was collected three times on a clear day downwind from the prevailing wind. Rainwater falling from the slate roofing was collected four times with a 1.05-m rainwater pipe on a rainy day at the 20 farmhouses, filtered with a MCE filter, and analyzed with a phase contrast microscope. Results: The geometric mean of the number of asbestos fibers in the air of farmhouses with slate roofing was 0.11 fiber/L, and no samples exceeded the recommended standard of 10 fiber/L. As a result of multiple regression analysis, a factor which gave a significant influence to the asbestos fiber content in the air was the gross area of slate roofing at the target farmhouses. The number of asbestos fibers included in rainwater collected per 1 m2 of slate roofing was 1,753 fiber/$L{\cdot}m2$. As a result of multiple regression analysis, the number of asbestos fibers contained in rainwater per 1 m2 of slate showed a significantly higher tendency as the year of slate roofing installation at the target farmhouses receded. Conclusions: It was confirmed for the first time in Korea that asbestos from asbestos cement slate roofing scatters into the air.