• Title/Summary/Keyword: double-combining

Search Result 112, Processing Time 0.02 seconds

Double Threshold Method for EMG-based Human-Computer Interface (근전도 기반 휴먼-컴퓨터 인터페이스를 위한 이중 문턱치 기법)

  • Lee Myungjoon;Moon Inhyuk;Mun Museong
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.471-478
    • /
    • 2004
  • Electromyogram (EMC) signal generated by voluntary contraction of muscles is often used in a rehabilitation devices such as an upper limb prosthesis because of its distinct output characteristics compared to other bio-signals. This paper proposes an EMG-based human-computer interface (HCI) for the control of the above-elbow prosthesis or the wheelchair. To control such rehabilitation devices, user generates four commands by combining voluntary contraction of two different muscles such as levator scapulae muscles and flexor-extensor carpi ulnaris muscles. The muscle contraction is detected by comparing the mean absolute value of the EMG signal with a preset threshold value. However. since the time difference in muscle firing can occur when the patient tries simultaneous co-contraction of two muscles, it is difficult to determine whether the patient's intention is co-contraction. Hence, the use of the comparison method using a single threshold value is not feasible for recognizing such co-contraction motion. Here, we propose a novel method using double threshold values composed of a primary threshold and an auxiliary threshold. Using the double threshold method, the co-contraction state is easily detected, and diverse interface commands can be used for the EMG-based HCI. The experimental results with real-time EMG processing showed that the double threshold method is feasible for the EMG-based HCI to control the myoelectric prosthetic hand and the powered wheelchair.

Quantitative Flow Field Visualization of a Flow inside an Opaque Tube Using Angiographic PIV Method (X선관을 이용한 불투명한 물체 내부 유동의 정량적 가시화 연구)

  • Kim, Guk-Bae;Lim, Nam-Yun;Ryu, Jae-Chun;Yim, Dae-Hyun;Lee, Hyung-Koo;Lee, Sang-Joon
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2935-2940
    • /
    • 2007
  • To diagnose circulatory diseases in the viewpoint of hemodynamics, we need to get quantitative hemodynamic information of blood flows related with the vascular diseases with high spatial resolution of tens micrometer and high temporal resolution in the order of millisecond. For investigating in-vivo hemodynamic phenomena, a new diagnosing technique combining medical radiography and PIV method was newly proposed and developed. This angiographic PIV technique consists of a medical X-ray tube, an X-ray CCD camera, a shutter module for double pulses of X-ray, and a synchronizer. The feasibility of the angiographic PIV technique was tested and quantitative flow velocity field distribution of a flow inside an opaque conduit was acquired by the developed system. It can be used for measuring flow phenomena of nontransparent fluids inside opaque conduits.

  • PDF

Two-Stage Spectrum Sensing Scheme Using Fuzzy Logic for Cognitive Radio Networks

  • Satrio, Cahyo Tri;Jaeshin, Jang
    • Journal of information and communication convergence engineering
    • /
    • v.14 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • Spectrum sensing in cognitive radio networks allows secondary users to sense the unused spectrum without causing interference to primary users. Cognitive radio requires more accurate sensing results from unused portions of the spectrum. Accurate spectrum sensing techniques can reduce the probability of false alarms and misdetection. In this paper, a two-stage spectrum sensing scheme is proposed for cooperative spectrum sensing in cognitive radio networks. In the first stage, spectrum sensing is executed for each secondary user using energy detection based on double adaptive thresholds to determine the spectrum condition. If the energy value lies between two thresholds, a fuzzy logic scheme is applied to determine the channel conditions more accurately. In the second stage, a fusion center combines the results of each secondary user and uses a fuzzy logic scheme for combining all decisions. The simulation results show that the proposed scheme provides increased sensing accuracy by about 20% in some cases.

MIMO Antenna Using Resonance of Ground Planes for 4G Mobile Application

  • Zhao, Xing;Kwon, Kyeol;Choi, Jeahoon
    • Journal of electromagnetic engineering and science
    • /
    • v.13 no.1
    • /
    • pp.51-53
    • /
    • 2013
  • A MIMO antenna using the resonance of ground planes is proposed for 4G mobile application. A resonant mode is generated when the double ground planes (upper and lower) in the mobile terminal are excited as the radiator. By combining the resonant modes contributed from both the antenna element and the ground planes, the proposed MIMO antenna realizes a wideband property over LTE band 13. In addition, an inductive coil is employed to reduce the antenna volume. These approaches not only simplify antenna design but also effectively improve bandwidth and efficiency. The proposed MIMO antenna has an excellent ECC value of below 0.1 because of the nearly orthogonal radiation patterns of the two radiators. Moreover, an additional antenna is adopted to cover WiMAX, WLAN, and Bluetooth services simultaneously in frequency range from 2 GHz to 2.7 GHz.

Operation-sequence-based Approach for Designing a U-shaped Independent-Cell System with Machine Requirement Incorporated (설비능력과 작업순서를 고려한 U-라인상에서의 셀 시스템 설계)

  • 박연기;성창섭;정병호
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.26 no.1
    • /
    • pp.71-85
    • /
    • 2001
  • This paper considers a cost model for a U-shaped manufacturing cell formation which incorporates a required number of machines and various material flows together under multi-part multi-cell environment. The model is required to satisfy both the specified operation sequence of each part and the total part demand volume, which are considered to derive material handling cost in U-shaped flow line cells. In the model several cost-incurring factors including set-up for batch change-over, processing time for operations of each part, and machine failures are also considered in association with processing load and capacity of each cell. Moreover, a heuristic for a good machine layout in each cell is newly proposed based on the material handling cost of each alternative sequence layout. These all are put together to present an efficient heuristic for the U-shaped independent-cell formation problem, numerical problems are solved to illustrate the algorithm.

  • PDF

Nonlinear Feedback Linearization-H\ulcorner/Sliding Mode Controller Design for Improving Transient Stability in a Power System

  • Lee, Sang-Seung;Park, Jong-Keun
    • Journal of Electrical Engineering and information Science
    • /
    • v.3 no.2
    • /
    • pp.193-201
    • /
    • 1998
  • In this paper, the standard Dole, Glover, Khargoneker, and Francis (abbr. : DGKF 1989) H\ulcorner controller (H\ulcornerC) is extended to the nonlinear feedback linearization-H\ulcorner/sliding mode controller (NFL-H\ulcorner/SMC), to tackle the problem of the unmeasurable state variables as in the conventional SMC, to obtain smooth control as the linearized controller in a linear system, and to improve the time-domain performance under a worst scenario. The proposed controller is obtained by combining the H\ulcorner estimator with the nonlinear feedback linearization-sliding mode controller (NFL-SMC) and it does not need to measure all the state variables as in the traditional SMC. The proposed controller is applied as a nonlinear power system stabilizer (PSS) for the improvement of the power system damping characteristics of an single machine infinite bus system (SMIBS) connected through a double circuit line. The effectiveness of the proposed controller is verified by nonlinear time-domain simulation in case of a 3-cycle line-to-ground fault and in case of the parameter variations for the AVR gain K\ulcorner and for the inertia moment M.

  • PDF

Mitigation of Transmission Line Magnetic Field by Installation of Passive Shield-Loop. (수동루프 설치에 의한 송전선로 자계 저감)

  • Kim Jeong-Boo;Shin Koo-Yong;Shin Myung Chul
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.2
    • /
    • pp.59-61
    • /
    • 2006
  • In our country most of transmission lines are double-circuit lines. In these lines, the combining method of increasing conductor height and installation of passive shield-loop to mitigate magnetic field near a transmission line, is a good and feasible method. The basic principle of passive shield loop is that the field from the current induced in the shield loop conductors counteracts the field from the phase conductors. This method applied to domestic transmission lines to meet the magnetic field level, 100, 30, 10 and 4 mG, respectively. In each magnetic field level, the minimum conductor height and passive loop height are presented for the implementation of the practical design.

Quantile Estimation in Successive Sampling

  • Singh, Housila P.;Tailor, Ritesh;Singh, Sarjinder;Kim, Jong-Min
    • Proceedings of the Korean Association for Survey Research Conference
    • /
    • 2006.12a
    • /
    • pp.67-83
    • /
    • 2006
  • In successive sampling on two occasions the problem of estimating a finite population quantile has been considered. The theory developed aims at providing the optimum estimates by combining (i) three double sampling estimators viz. ratio-type, product-type and regression-type, from the matched portion of the sample and (ii) a simple quantile based on a random sample from the unmatched portion of the sample on the second occasion. The approximate variance formulae of the suggested estimators have been obtained. Optimal matching fraction is discussed. A simulation study is carried out in order to compare the three estimators and direct estimator. It is found that the performance of the regression-type estimator is the best among all the estimators discussed here.

  • PDF

Development of Manufacturing Method of Vessel for Keeping Warm by Hydraulic Bulging

  • Chung, Joon-Ki;Cho, Woong-Shick
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.2 no.4
    • /
    • pp.40-46
    • /
    • 2001
  • Bulging is a forming method to shape die cavity by using hydraulic pressure in tube or vessel. Bulging machine and die were developed in order to produce vessel for keeping warm. Bulging machine is a double type with two horizontal cylinders for bulging of two pieces at the same time. The developed die system has one bulging die and two drawing dies for necking at both ends of the tube. The diameter of tube expands by hydraulic pressure in tube. At the same time, thrust at both ends of the tube pushes tube in the direction of expansion to obtain high expansion rate with no crack. In this study, the bulging properties were investigated to solve tube crack and necking in manufacturing vessel by combining bulging and drawing. As a result, high expanding rate of tube radius without crack, precision necking and high productivity were obtained.

  • PDF

Development of angiographic PIV and performance evaluation (Angiographic PIV기법 개발 및 성능 평가)

  • Jung, Sung-Yong;Kim, Guk-Bae;Lim, Nam-Yun;Lee, Sang-Joon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.683-686
    • /
    • 2008
  • To diagnose vascular diseases from the viewpoint of hemodynamics, detailed quantitative hemodynamic information of related blood flows with a high spatial resolution of tens micrometer and a high temporal resolution in the order of millisecond were required. For investigating the hemodynamic phenomena of vascular circulatory diseases, a new diagnosing technique combining a medical radiography and PIV method was newly developed. This technique consisted of a medical X-ray tube, an X-ray CCD camera, a shutter module for double pulse-type X-ray source, and a synchronizer. Through several preliminary tests, the feasibility of the angiographic PIV technique was verified. For in-vivo measurements to real blood flows, we developed tracer microcapsules which were optimized to this system by encapsulating a contrast material of iodine with a matrix material of PVA (polyvinylpyrrolidone). In near future, the angiographic PIV technique would be useful for diagnosing hemodynamic phenomena of vascular diseases and for their early detection.

  • PDF