• Title/Summary/Keyword: double scan

Search Result 104, Processing Time 0.031 seconds

A Real-time Copper Foil Inspection System using Multi-thread (다중 스레드를 이용한 실시간 동판 검사 시스템)

  • Lee Chae-Kwang;Choi Dong-Hyuk
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.10 no.6
    • /
    • pp.499-506
    • /
    • 2004
  • The copper foil surface inspection system is necessary for the factory automation and product quality. The developed system is composed of the high speed line scan camera, the image capture board and the processing computer. For the system resource utilization and real-time processing, multi-threaded architecture is introduced. There are one image capture thread, 2 or more defect detection threads, and one defect communication thread. To process the high-speed input image data, the I/O overlap is used through the double buffering. The defect is first detected by the predetermined threshold. To cope with the light irregularity, the compensation process is applied. After defect detection, defect type is classified with the defect width, eigenvalue ratio of the defect covariance matrix and gray level of defect. In experiment, for high-speed input image data, real-time processing is possible with multi -threaded architecture, and the 89.4% of the total 141 defects correctly classified.

Wafer-Level Fabrication of a Two-Axis Micromirror Driven by the Vertical Comb Drive (웨이퍼 레벨 공정이 가능한 2축 수직 콤 구동 방식 마이크로미러)

  • Kim, Min-Soo;Yoo, Byung-Wook;Jin, Joo-Young;Jeon, Jin-A;Park, Il-Heung;Park, Jae-Hyoung;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.148-149
    • /
    • 2007
  • We present the design and fabrication prcoess of a two-axis tilting micromirror device driven by the electrostatic vertical comb actuator. A high aspect-ratio comb actuator is fabricated by multiple DRIE process in order to achieve large scan angle. The proposed fabrication process enables a mirror to be fabricated on the wafer-scale. By bonding a double-side polished (DSP) wafer and a silicon-on-insulator (SOI) wafer together, all actuators on the wafer are completely hidden under the reflectors. Nickel lines are embedded on a Pyrex wafer for the electrical access to numerous electrodes of mirrors. An anodic bonding step is implemented to contact electrical lines with ail electrodes on the wafer at a time. The mechanical angle of a fabricated mirror has been measured to be 1.9 degree and 1.6 degree, respectively, in the two orthogonal axes under driving voltages of 100 V. Also, a $8{\times}8$ array of micromirrors with high fill-factor of 70 % is fabricated by the same fabrication process.

  • PDF

The Effect of CNT Electrode on the Charging and Discharging Characteristics of Supercapacitor (CNT를 이용한 Supercapacitor의 충.방전 특성)

  • Hur, Geun;Myoung, Seong-Jae;Lee, Yong-Hyun;Chun, Myoung-Pyo;Cho, Jeong-Ho;Kim, Byung-Ik;Shim, Kwang-Bo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.275-275
    • /
    • 2007
  • Two sorts of electrode composed of Sulpur/CNT/PVDF and Silver/CNT/PVDF were prepared by in situ chemical method and their electrochemical performance were evaluated by using cyclic voltammetry, impedance measurement and constant-current charge/discharge cycling technique. Also, composite electrodes were characterized by FE-SEM and BET. Raw materials such as CNT/Silver and CNT/Sulfur were mixed in ethanol, dried. These mixed materials were heated at 900 and $320^{\circ}C$ for 2hr, respectively in order to enhance contact among CNT electrodes. Electric double layer capacitor cells were fabricated using these mixed powder with polymer of PVDF. For the charging and discharging characteristics measured at scan rate of 1 mA/s, Supercapacitor of Sulphur-CNT-PVDF electrode showed a better performance than that of Ag-CNT-PVDF, which seems to be related with lower contact resistance of Sulphur-CNT-PVDF electrode.

  • PDF

Design of Run-time signal test architecture in IEEE 1149.1 (IEEE 1149.1의 실시간 신호 시험 구조 설계)

  • Kim, Jeong-Hong;Kim, Young-Sig;Kim, Jae-Soo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.1
    • /
    • pp.13-21
    • /
    • 2010
  • IEEE 1149.1 test architecture was proposed to support the test of elements within the boards. It is a large serial shift register that uses the TDI pin as an input and the TDO pin as an output. Even though it performs the board level test perfectly, there is a problems of running system level test when the boards are equipped to the system. To test real time operation signal on test pin, output speed of serial shift register chain must be above double clock speed of shift register. In this paper, we designed a runtime test architecture and a runtime test procedure under running system environments to capture runtime signal at system clock rate. The suggested runtime test architecture are simulated by Altera Max+Plus 10.0. through the runtime test procedure. The simulation results show that operations of the suggested runtime test architecture are very accurate.

Monte Carlo Simulation of Irradiation Treatment of Peaches (Prunus persica L. Batsch) (몬테카를로 시뮬레이션을 이용한 복숭아의 방사선 조사)

  • Kim, Jongsoon;Kim, Dong-Hyun;Park, Jong-Min;Choi, Won-Sik;Kwon, Soon Hong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.21 no.6
    • /
    • pp.337-344
    • /
    • 2018
  • Food irradiation is important not only in ensuring safety but also improving antioxidant activity of peaches. Our objective was to establish the best irradiation treatment for peaches by calculating dose distribution using Monte Carlo simulation. 3-D geometry and component densities of peaches, extracted from CT scan, were entered into MCNP to obtain simulated dose distribution. Radiation energies for electron beam were 1.35 MeV (low energy) and 10 MeV (high energy). Co (1.25 MeV) and the Husman irradiator, containing three sealed Cs source rods in an annular array, were used for gamma irradiation. At 1.35 MeV electron beam simulation, electrons penetrated well beyond the peach skin, enough for surface treatment for microorganisms and allergens. At 10 MeV electron beam simulation, for top-beam only treatment, doses at the core were the highest and for double beam treatment, the electron energy was absorbed by the entire sample. At Co source, the radiation doses were presented on the whole area. At Cs source, the dose uniformity ratios were 2.78 for one source and 1.48 for three ones at 120 degrees interval. Proper control of irradiation treatment is critical to establish confidence in the irradiation process.

One Anchor Double Fixation (OADF) Technique for Arthroscopic Bony Bankart Repair (두가닥의 봉합사를 가진 봉합나사못을 이용한 새로운 관절경적 골성 방카르트 병변 봉합술)

  • Choi, Eui-Sung;Park, Kyoung-Jin;Kim, Yong-Min;Kim, Dong-Soo;Shon, Hyun-Chul;Cho, Byung-Ki;Bae, Seung-Hwan
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.40-46
    • /
    • 2010
  • Purpose: The aim of this study was to evaluate the usefulness of arthroscopic Bony Bankart repair using a One Anchor Double Fixation Technique. Materials and Method: Seventeen patients with a Bony Bankart lesion were treated using the One Anchor Double Fixation Technique (OADF Technique). There were 13 males and 4 females. The average age was 24 years (range 17-42). The average follow-up period was 22.3 months. One 3.0 mm suture anchor with doubly loaded sutures was inserted into the glenoid rim. One suture strand was passed the around the small bony fragment and tied first. Another suture strand was passed through the capsule and tied over the bony fragment. The result was measured using Rowe's evaluation index & KSS score. The glenoid defect & bony fragment were measured by 3D-CT scan. Results: Rowe's evaluation index on the final follow-up showed an overall improvement from an average of 54 (range, 23-71) to 83.4 (range 71-90). Of the 17 cases, 13 were excellent, 3 were good, and 1 was fair. KSS scores showed improvement from an average of 71 (range 49-82) to 92.5 (range 82-94). There were no cases where pain continued to the final follow-up, and no cases being re-dislocated during the follow-up period. For six cases, we confirmed the bony healing of the bony Bankart lesion by CT. Conclusion: Bony Bankart lesion repair using this new method achieves excellent clinical results with low recurrence rates and is considered another choice for bony Bankart lesions.

The Synchronous Occurrence of Splenic Marginal Zone Lymphoma in a Patient with Early Gastric Cancer: A Case Report (조기 위암과 동반된 비장 변연부 림프종 1예)

  • Park, Hyo-Jun;Kim, Keung-Mi;Choi, Min-Gew;Noh, Jae-Hyung;Sohn, Tae-Sung;Bae, Jae-Moon;Kim, Sung
    • Journal of Gastric Cancer
    • /
    • v.9 no.2
    • /
    • pp.63-67
    • /
    • 2009
  • Splenic marginal zone lymphoma (SMZL) is a rare type of non-Hodgkin's lymphoma (NHL). We report here on a patient who displayed the synchronous occurrence of SMZL and early gastric cancer (EGC). The patient was a 74 year-old male with liver cirrhosis. An EGC in the gastric antrum was diagnosed and the preoperative abdomen computed tomography scan revealed splenomegaly and intra-abdominal lymphadenopathy. We performed subtotal gastrectomy and the postoperative pathologic examination revealed adenocarcinoma limited to the gastric mucosa and SMZL in the lymph nodes. The patient recovered from the surgery without complications and is now awaiting chemotherapy. SMZL has an indolent clinical course with good long-term survival and so there is the possibility of the occurrence of a second primary malignancy. Rare cases of a second primary malignancy being diagnosed along with SMZL have been described in the literature. Patients with SMZL should be carefully followed after treatment to detect the possible occurance of a second primary malignancy.

  • PDF

Influence of Textural Structure by Heat-treatment on Electrochemical Properties of Pitch-based Activated Carbon Fiber (열처리 온도에 의한 피치계 활성탄소섬유의 기공구조 변화가 전기화학적 특성에 미치는 영향)

  • Kim, Kyung Hoon;Park, Mi-Seon;Jung, Min-Jung;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • v.26 no.5
    • /
    • pp.598-603
    • /
    • 2015
  • In this study, electrochemical properties of pitch-based activated carbon fibers (ACFs) were investigated by different heat-treatment temperature of the pitch-based ACFs in order to improve the specific capacitance of electric double-layer capacitor (EDLC). The ACFs were prepared by different heat-treatment temperatures of 1050 and $1450^{\circ}C$, after activation with 4 M KOH at $800^{\circ}C$ using stabilized pitch fiber. The specific surface area of prepared ACFs increased from $828m^2/g$ to $987m^2/g$, also the micropore and mesopore volumes of prepared ACFs were increased. These results because pore was produced by desorbing oxygen and hydrogen elements within the ACFs, and pore size was increased by contraction ACFs by heat-treatment process. Because of the porous properties, the specific capacitance was increased from 73 F/g to 119 F/g using cyclic voltammetry with 1 M $H_2SO_4$ at scan rates of 5 mV/s.

Superior Gluteal Artery Perforator Turn-Over Flap Coverage for Lumboscaral Soft Tissue Defect in Ambulatory Patient (보행 환자에서의 위볼기동맥천공지뒤집기피판을 이용한 허리엉치 부위 연부조직 결손의 치료)

  • Moon, Suk-Ho;Kim, Dong-Seok;Oh, Deuk-Young;Lee, Jung-Ho;Rhie, Jong-Won;Seo, Je-Won;Ahn, Sang-Tae
    • Archives of Plastic Surgery
    • /
    • v.37 no.5
    • /
    • pp.712-716
    • /
    • 2010
  • Purpose: Extensive lumbosacral defects after removal of spinal tumors have a high risk of wound healing problems. Therefore it is an effective reconstructive strategy to provide preemptive soft tissue coverage at the time of initial spinal surgery, especially when there is an instrument exposure. For soft tissue reconstruction of a lumbosacral defect, a variation of the gluteal flap is the first-line choice. However, the musculocutaneous flap or muscle flap that is conventionally used, has many disadvantages. It damages gluteus muscle and causes functional disturbance in ambulation, has a short pedicle which limits areas of coverage, and can damage perforators, limiting further surgery that is usually necessary in spinal tumor patients. In this article, we present the superior gluteal artery perforator turn-over flap that reconstructs complex lumbosacral defects successfully, especially one that has instrument exposure, without damaging the ambulatory function of the patient. Methods: A 67 year old man presented with sacral sarcoma. Sacralectomy with L5 corpectomy was performed and resulted in a $15{\times}8\;cm$ sized complex soft tissue defect in the lumbosacral area. There was no defect in the skin. Sacral stabilization with alloplastic fibular bone graft and reconstruction plate was done and the instruments were exposed through the wound. A $18{\times}8\;cm$ sized superior gluteal artery perforator flap was designed based on the superior gluteal artery perforator and deepithelized. It was turned over 180 degrees into the lumbosacral dead space. Soft tissue from both sides of the wound was approximated over the flap and this provided in double padding over the instrument. Results: No complications such as hematoma, flap necrosis, or infection occurred. Until three months after the resection, functional disturbances in walking were not observed. The postoperative magnetic resonance imaging scan shows the flap volume was well maintained over the instrument. Conclusion: This superior gluteal artery perforator turn-over flap, a modification of the conventional superior gluteal artery perforator flap, is a simple method that enabled the successful reconstruction of a lumbosacral defect with instrument exposure without affecting ambulatory function.

Developement of Planar Active Array Antenna System for Radar (평면형 능동 위상 배열 레이더용 안테나 시스템 개발)

  • Chon, Sang-Mi;Na, Hyung-Gi;Kim, Soo-Bum;Lee, Jeong-Won;Kim, Dong-Yoon;Kim, Seon-Joo;Ahn, Chang-Soo;Lee, Chang-Hee
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.12
    • /
    • pp.1340-1350
    • /
    • 2009
  • The design and implementation of planar Active Phased Array Antenna System are described in this paper. This Antenna system operates at X-band with its bandwidth 10 % and dual polarization is realized using dual slot feeding microstrip patch antenna and SPDT(Single Pole Double Through) switch. Array Structure is $16\times16$ triangular lattice structure and each array is composed of TR(Transmit & Receive) module with more than 40 dBm power. Each TR module includes digital attenuator and phase shifter so that antenna beam can be electronically steered over a scan angle$({\pm}60^{\circ})$. Measurement of antenna pattern is conducted using a near field chamber and the results coincide with the expected beam pattern. From these results, it can be convinced that this antenna can be used with control of beam steering and beam shaping.