• Title/Summary/Keyword: dosimeters

Search Result 203, Processing Time 0.02 seconds

How Effective Are Radiation Reducing Gloves in C-arm Fluoroscopy-guided Pain Interventions?

  • Kim, Ah Na;Chang, Young Jae;Cheon, Bo Kyung;Kim, Jae Hun
    • The Korean Journal of Pain
    • /
    • v.27 no.2
    • /
    • pp.145-151
    • /
    • 2014
  • Background: The physician's hands are close to the X-ray field in C-arm fluoroscopy-guided pain interventions. We prospectively investigated the radiation attenuation of Proguard RR-2 gloves. Methods: In 100 cases, the effective doses (EDs) of two dosimeters without a radiation-reducing glove were collected. EDs from the two dosimeters-one dosimeter wrapped with a glove and the other dosimeter without a glove-were also measured at the side of the table (Group 1, 140 cases) and at a location 20 cm away from the side of the table (Group 2, 120 cases). Mean differences such as age, height, weight, radiation absorbed dose (RAD), exposure time, ED, and ratio of EDs were analyzed. Results: In the EDs of two dosimeters without gloves, there were no significant differences ($39.0{\pm}36.3{\mu}Sv$ vs. $38.8{\pm}36.4{\mu}Sv$) (P = 0.578). The RAD ($192.0{\pm}182.0radcm^2$) in Group 2 was higher than that ($132.3{\pm}103.5radcm^2$) in Group 1 (P = 0.002). The ED ($33.3{\pm}30.9{\mu}Sv$) of the dosimeter without a glove in Group 1 was higher than that ($12.3{\pm}8.8{\mu}Sv$) in Group 2 (P < 0.001). The ED ($24.4{\pm}22.4{\mu}Sv$) of the dosimeter wrapped with a glove in Group 1 was higher than that ($9.2{\pm}6.8{\mu}Sv$) in Group 2 (P < 0.001). No significant differences were noted in the ratio of EDs ($73.5{\pm}6.7%$ vs. $74.2{\pm}9.3%$, P = 0.469) between Group 1 and Group 2. Conclusions: Proguard RR-2 gloves have a radiation attenuation effect of 25.8-26.5%. The radiation attenuation is not significantly different by intensity of scatter radiation or the different RADs of C-arm fluoroscopy.

Radiation Safety Exploration Using Radio-photoluminescence Dosimeter for Crookes Tubes in Junior and Senior High School in Japan

  • Akiyoshi, Masafumi;Do, Duy Khiem;Yamaguchi, Ichiro;Kakefu, Tomohisa;Miyakawa, Toshiharu
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.3
    • /
    • pp.106-111
    • /
    • 2021
  • Background: Crookes tube is utilized in junior high and high schools in Japan to study the character of electrons and current, and not for radiological education. There is no official guideline or regulation for these radiation source to the public. Therefore, most teachers have no information about the leakage of X-rays from Crookes tube. The peak energy of X-rays is approximately 20 keV, and it is impossible to measure using conventional survey meters. Materials and Methods: Each leakage dose of low energy X-rays from 38 Crookes tube in the education field, such as junior and senior high schools in Japan, was explored by the teachers in the school using radio-photoluminescence (RPL) dosimeters. Before and after the measurements, the dosimeters were sent by postal mails. Results and Discussion: At the exploration in this study, it was estimated that the 70 ㎛ dose equivalent, Hp(0.07) of X-rays from 31 Crookes tubes were smaller than 100 µSv in 10 minutes, at the distance of 1 m, where the Crookes tube was usually observed. However, the highest dose was estimated as 0.69 mSv by an equipment with the full power. Furthermore, one Crookes tube exhibited 0.62 mSv with minimum output power of the induction coil. This relatively large dose was reduced by the shorter distance of discharge electrodes of the induction coil. Conclusion: The leakage dose of low energy X-rays from 38 Crookes tube was explored using RPL dosimeters. It was estimated that the Hp(0.07) of X-rays from 31 Crookes tubes were smaller than 100 µSv in 10 minutes at the distance of 1 m, while some equipment radiated a higher dose. With this study, the provisional guideline for the safety operation of Crookes tube is established.

Effects of Fully Filling Deep Electron/Hole Traps in Optically Stimulated Luminescence Dosimeters in the Kilovoltage Energy Range

  • Chun, Minsoo;Jin, Hyeongmin;Lee, Sung Young;Kwon, Ohyun;Choi, Chang Heon;Park, Jong Min;Kim, Jung-in
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.3
    • /
    • pp.134-142
    • /
    • 2022
  • Background: This study investigated the characteristics of optically stimulated luminescence dosimeters (OSLDs) with fully filled deep electron/hole traps in the kV energy ranges. Materials and Methods: The experimental group consisted of InLight nanoDots, whose deep electron/hole traps were fully filled with 5 kGy pre-irradiation (OSLDexp), whereas the non-pre-irradiated OSLDs were arranged as a control group (OSLDcont). Absorbed doses for 75, 80, 85, 90, 95, 100, and 105 kVp with 200 mA and 40 ms were measured and defined as the unit doses for each energy value. A bleaching device equipped with a 520-nm long-pass filter was used, and the strong beam mode was used to read out signal counts. The characteristics were investigated in terms of fading, dose sensitivities according to the accumulated doses, and dose linearity. Results and Discussion: In OSLDexp, the average normalized counts (sensitivities) were 12.7%, 14.0%, 15.0%, 10.2%, 18.0%, 17.9%, and 17.3% higher compared with those in OSLDcont for 75, 80, 90, 95, 100, and 105 kVp, respectively. The dose accumulation and bleaching time did not significantly alter the sensitivity, regardless of the filling of deep traps for all radiation qualities. Both OSLDexp and OSLDcont exhibited good linearity, by showing coefficients determination (R2) > 0.99. The OSL sensitivities can be increased by filling of deep electron/hole traps in the energy ranges between 75 and 105 kVp, and they exhibited no significant variations according to the bleaching time.

Evaluation of RPL Glass Dosimeter Characteristics and Uncertainty Evaluation of Reading Correction Factors (유리선량계 특성평가 및 판독 보정인자에 대한 불확도 평가)

  • Seong-Yun Mok;Yeong-Rok Kang;Hyo-Jin Kim;Yong-Uk Kye;Hyun An
    • Journal of radiological science and technology
    • /
    • v.46 no.3
    • /
    • pp.219-229
    • /
    • 2023
  • In this study, basic characteristics such as reproducibility, linearity, and directionality of RPL glass dosimeters were evaluated to improve the reliability of dose evaluation through RPL glass dosimeters, and uncertainty elements such as sensitivity by glass element and magazine slot sensitivity were evaluated. Using a mathematical model to calibrate the measured values of the RPL glass dosimeter, the measurement uncertainty was calculated assuming an example. As a result of the characteristic evaluation, the RPL glass dosimeter showed excellent performance with a standard deviation of ±1% (1 SD) for the reproducibility of the reading process, a coefficient of determination for linearity of 0.99997. And the read-out of the RPL glass dosimeter are affected by the circular rotation direction of the glass dosimeter during irradiation, fading according to the period after irradiation, the number of laser pulses of the reader, and response degradation due to repeated reading, it is judged that measurement uncertainty can be reduced by irradiation and reading in consideration of these factors. In addition, it was confirmed that the dose should be determined by calculating the correction factors for the sensitivity of each element and, the sensitivity of each reading magazine slot. It is believed that the reliability of dosimetry using glass dosimeters can be improved by using a mathematical model for correction of glass dosimeter readings and calculating measurement uncertainty.

Experimental study on build up characteristic of glass dosimeter of preheat and Non-preheat in low energy according to delay time (저에너지X선 영역에서 유리선량계의 preheat과 Non-preheat과의 시간에 따른 build up 특성에 관한 연구)

  • Son, Jin-Hyun;Min, Jung-Whan;Kim, Ki-Won;Son, Soon-Yong;Lim, Hyun-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.7
    • /
    • pp.3412-3418
    • /
    • 2013
  • The Purpose of this study was to evaluate by comparing the dose change and build up characteristic according to delay time in 30 days of glass dosimeter processed preheat and non preheat when measuring accumulation dose of radiation by using glass dosimeter over the long haul. For obtaining low dose with 0.1 mGy, 1 mGy and 5 mGy, we employed diagnostic generator AccuRay-650R. We compared the build up characteristic over the long haul by exposuring radiation to 30 glass dosimeters sorted into 10 glass dosimeters per tube voltage and current. In Non preheat glass dosimeter, initial measured dose was inferior to exposed dose but as time goes on, was close to exposed dose steadily. In 72 hour after experiment end, non preheat glass dosimeters were not indicated the difference from preheat glass dosimeters and statistical analysis were meaningful (p>0.05). Initial measured dose for low glass dosimeter processed preheat was close to exposed dose and stable. After 15 days dose was gradually increased. Previous study characteristics of glass dosimeter were with respect to characteristic of glass dosimeter in high dose of high energy area. However, in this study, we make a judgment to measure the dose of glass dosimeter without preheat processing when measuring the accumulation dose of low dose in conclusion.

Domestic Intercomparison Study for the Performance of Personnel Dosimeters (개인선량계 성능의 국내 상호비교)

  • Kim, Jang-Lyul;Chang, Si-Young;Kim, Bong-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.3
    • /
    • pp.147-153
    • /
    • 1996
  • The Korea Atomic Energy Research Institute(KAERI) conducted a intercomparison study for personnel dosimetry services in Korea to enhance the accuracy and precision of the dosimetry system. Nine types of dosimeters(6 TLD, 3 film badge) from 7 institutions took part in this intercomparison study. Each participant submitted 30 dosimeters including transit control for irradiations. Both TLDs and film badges were irradiated with Cs-137 gamma, Sr/Y-90 beta and 4 X-ray beams in ISO wide series. Four dosimeters were irradiated on phantom with same dose equivalent for each field category. The delivered dose equivalent was in the range of $0.1{\sim}10mSv$. The participants assessed the results of their dosimeter readings in terms of the ICRU operational quantities for personal monitoring, Hp(10) and Hp(0.07). Most participants except 1 dosimeter estimated the delivered dose equivalent with biases less than ${\pm}25%$ for Cs-137 and Sr/Y-90. But for X-rays, the biases exceeded ${\pm}35%$ in some cases bacause the dose evaluation algorithm was based on the ANSI N13.11 X-ray fields which are different from those given by ISO.

  • PDF

Evaluation of Reductive Effect of Exposure Dose by Using Air Gap Apron in Nuclear Medicine Related Work Environment (핵의학과 내 작업 환경에서 공기층 납치마의 피폭선량 감소 효과 평가)

  • Lee, Wang-Hui;Ahn, Sung-Min
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.12
    • /
    • pp.845-853
    • /
    • 2014
  • In this study, we measured the dose reaching the OSLD dosimeter by using the regular lead apron, and air gap apron through 3 experiments, and researched the reductive effect of air gap apron on exposure dose based on the 140 keV gamma ray radiating from $^{99m}technetium$, which is the most commonly used in nuclear medicine. As a result, when the gap between the dosimeter and 0.2mm lead plate is 0 Cm, the average value of 10 dosimeters was 0.515 mSv, and when the gap between the dosimeter and lead plate is 20 Cm, the average value of 10 dosimeters was 0.138 mSv, which shows reductive effect of dose as much as 0.388 mSv. When the gap between the dosimeter and 0.5mm lead plate is 0 Cm, the average value of 10 dosimeters was 0.296 mSv, and when the gap between the dosimeter and lead plate is 20 Cm, the average value of 10 dosimeters was 0.075 mSv, which shows reductive effect of dose as much as 0.221 mSv. As we check the cumulative dosage for 3 days, the lead apron without air layer shows average 0.239 mSv, and the air gap apron shows 0.176 mSv, which is actually reduced by 0.062 mSv. As we check the cumulative dosage for a month, the lead apron without air layer shows 0.59 mSv, and the air gap apron shows 0.54 mSv, which is reduced by 0.05 mSv.

Characteristics of $CaSO_4$:Dy TL Dosimeters by Determining LLDs, Fadings and Sensitivity Changes in Repeat Uses (최소검출한계, 잠상퇴행 및 반복사용으로 인한 감도면화 결정에 의한 $CaSO_4$:Dy 열형광선량계 특성)

  • Kim, Jang-Lyul;Kim, Bong-Hwan;Chang, Si-Young;Lee, Hyung-Sub;Lee, Jae-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.3
    • /
    • pp.161-170
    • /
    • 1997
  • Theoretical and experimental determination of the lower limits of detection (LLD) of C-300-A $CaSO_4$:Dy TL dosimeters which are currently used for the personnel monitoring in Korea Atomic Energy Research Institute(KAERI) are described with a critical level which is defined as the signal level above which a result has a probability of being due to a fluctuation of the background. The personnel monitoring processors can derived easily the LLD of their system using this method with the background readings of their service interval and the irradiation readings of the known doses. Experimental studies were also conducted for the fading rates of the dosimeters with the temperatures and humidities for 3 months. Finally sensitivity changes in repeat uses were measured for 40 times consecutive uses of the dosimeters. The applications of the experimental results of fading rates and sensitivity changes in real personnel monitoring services are discussed briefly.

  • PDF

Monte Carlo Study of MOSFET Dosimeter Dose Correction Factors Considering Energy Spectrum of Radiation Field in a Steam Generator Channel Head (원전 증기발생기 수실 내 에너지 스펙트럼을 고려한 MOSFET 방사선검출기 선량보정인자 결정에 관한 몬테칼로 전산모사 연구)

  • Cho, Sung-Koo;Choi, Sang-Hyoun;Kim, Chan-Hyeong
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.4
    • /
    • pp.165-171
    • /
    • 2006
  • In Korea, a real-time effective dose measurement system is in development. The system uses 32 high-sensitivity MOSFET dosimeters to measure radiation doses at various organ locations in an anthropomorphic physical phantom. The MOSFET dosimeters are, however, mainly made of silicon and shows some degree of energy and angular dependence especially for low energy photons. This study determines the correction factors to correct for these dependences of the MOSFET dosimeters for accurate measurement of radiation doses at organ locations in the phantom. For this, first, the dose correction factors of MOSFET dosimeters were determined for the energy spectrum in the steam generator channel of the Kori Nuclear Power Plant Unit #1 by Monte Carlo simulations. Then, the results were compared with the dose correction factors from 0.652 MeV and 1.25 MeV mono-energetic photons. The difference of the dose correction factors were found very negligible $(\leq1.5%)$, which in general shows that the dose corrections factors determined from 0.662 MeV and 1.25 MeV can be in a steam general channel head of a nuclear power plant. The measured effective dose was generally found to decrease bit $\sim7%$ when we apply the dose correction factors.

The Effects of Metal Plate loaded on TLD chip in 6 MV Photon and 6 MeV Electron Beams (6 MV 광자선과 6 MeV 전자선 하에서 TLD 기판 위에 얹힌 금속 박막의 효과)

  • Kim, Sookil;Byungnim Min
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.41-46
    • /
    • 1999
  • There is necessity for making a smaller and more sensitive detector in small field sizes. This report assesses the suitability of metal-loaded thermoluminescent dosimeters for this purpose. Measurements were performed in the 6 MV photon and 6 MeV electron beams of a medical linear accelerator with LiF thermoluminescence dosimeters (TLD-100) embedded in solid water phantom. TLD-100 chips(surface area 3.2 $\times$ 3.2 $\textrm{mm}^2$) loaded with a metal plate(Tin or gold respectively) were used to enhance dose readings to TLD-100. Surface dose was measured for field size 10 $\times$ 10 $\textrm{cm}^2$ and 100 em SSD. Measurements have been made of the enhanced signal intensity and good linearity for absorbed dose with each metal. Using a 1 mm each metal on TLD-l00 in the beam increased the surface dose to 14% and 56% respectively for 6MV photon. In the case of 6 MeV electron, gold plate enhanced the TL response to 13%, but there is no difference for tin plate. The specific dose response of TLD-100 with thin metal plate increases with electron concentration of metal film, this is most likely due to increased electron scattered from the additional material with electron density higher than TLD-100. This emphasizes the role of TL dosimeters with metal as amplified dosimeters for therapeutic high energy x-ray beams. Due to the enhanced dose reading of TLD-100 with metal plate, it could be possible to develop smaller TL dosimeter with high sensitivity.

  • PDF