• Title/Summary/Keyword: dosimeters

Search Result 203, Processing Time 0.027 seconds

A Study on the Evaluation of 3D Dose Distribution using Normoxic Polymer Gel (정상산소 중합체 겔 선량계를 이용한 3차원 방사선량 평가에 관한 연구)

  • Chung, Se-Young;Kim, Young-Bum;Kwon, Young-Ho;Lee, Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.7-17
    • /
    • 2007
  • Purpose: As increasing complexity of modern radiotherapy technique, more developing dosimetry is required. Polymer gel dosimeters offer a wide range of potential applications with high resolution and assured quality in the thee-dimensional verification of complex dose distribution such as intensity-modulated radiotherapy (IMRT). The purpose of this study is to find the most sensitive and suitable gel as a dosimeter by varying its composition ratio and its condition such as temperature during manufacturing. Materials and Methods: Each polymer gel with various ratio of composition was irradiated with the same amount of photon beam accordingly. Various polymer gels were analyzed and compared using a dedicated software written in visual C++ which converts TE images to R2 map images. Their sensitivities to the photon beam depending on their composition ratio were investigated. Results: There is no dependence on beam energy nor dose rate, and calibration curve is linear. Conclusion: The polymer gel dosimeter developed by using anti-oxidant in this study proved to be suitable for dosimetry.

  • PDF

A Study on the Environmental Radiation Dose Measurement in the Nuclear Medicine Department (핵의학과에서 환경방사선량 측정에 대한 연구)

  • Kang, Bo-Sun;Lim, Chang-Seon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.6
    • /
    • pp.2118-2123
    • /
    • 2010
  • Korean individual occupational exposure control is focused on the retrospective service to the over-exposed person by the reading of personal dosimeter. Since the radiophamaceuticals using in the nuclear medicine department are uncontained radiation sources, the potential exposure at working environment is very high. Moreover, a patient remains radioactive for hours or even days after the administration of a radiopharmaceutical for diagnosis or treatment. Thus, the proper working environmental exposure control must be established and executed to protect not only the affiliated employees, but also guardians accompanying patients and temporarily visiting public from the exposure by the patients. Japanese radiation protection law regulates working environmental radiation exposure by regularly measuring and filing the environmental dose for years. This study was aimed at measuring working environmental radiation dose in the nuclear medicine department of an university hospital located in Daejeon, Korea. We measured the accumulation radiation dose in air at 8 locations in the nuclear medicine department by using the same method as in Japan with glass dosimeters. The highest dose rate, 0.23 mSv per month, was measured at the waiting room, and the second one is at reception desk. Even though the doses were lower than the Korean constraint dose rate (0.3 mSv/week) at the boundary of the radiation controlled area, it was over the dose limit of public (1 mSv/y) and environment (0.25 mSv/y). Conclusionally, it was found that the new or additional procedure was necessary to less the exposure dose to the receptionist and guardians by the environmental radiation dose in the nuclear medicine department.

A Theoretical Calculation for Angular Dependence of X-ray Beams on Extremity Phantom (말단팬텀에서 X-선 빔의 방향의존성에 관한 이론적 계산)

  • Kim, Jong-Soo;Yoon, Suk-Chul;Kim, Jang-Lyul;Kim, Kwang-Pyo
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.4
    • /
    • pp.263-271
    • /
    • 1996
  • The ANSI N13.32 recommends that a study of the angular response of a dosimeter be carried out once, although no pass/fail criterion is given for angular response. Gamma dose equivalent conversion and angular dependence factors were calculated by using MCNP code for the case of ANSI N13.32 extremity phantoms(finger and arm) at the depth of $7mg/cm^2$. Those extremity dosimeters were assumed to be irradiated from both monoenergitic photons and ISO X-ray narrow beams. These calculated gamma dose equivalent conversion and angular dependence factors were compared to B. Grosswendt's result calculated by using X-ray beams. The result showed that the dose equivalent conversion factors of this study agreed well with that of B. Grosswendt for all energies within 2% except 7% in the case of the low energies. In the case of angular dependence factors comparison, they agreed within 3%. It was shown that angular dependence factors of the finger phantom decreased as the horizontal angle of the phantom increased for the ISO X-ray beams less than 60keV. For the higher energy X-ray beams range they decreased slightly around 40 degree, but then increased from this energy to 90 degree.

  • PDF

High Energy Electron Dosimetry by Alanine/ESR Spectroscopy (Alanine/ESR Spectroscopy에 의한 고에너지 전자선의 선량측정)

  • Chu, Sung-Sil
    • Radiation Oncology Journal
    • /
    • v.7 no.1
    • /
    • pp.85-92
    • /
    • 1989
  • Dosimerty based on electron spin resonance (ESR) analysis of radiation induced free radicals in amino acids is relevant to biological dosimetry applications. Alanine detectors are without walls and are tissue equivalent. Therefore, alanine ESR dosimetry looks promising for use in the therapy level. The dose range of the alanine/ESR dosimetry system can be extended down to 1 Gy. In water phantom the absorbed dose of electrons generated by a medical linear accelerator of different initial energies $(6\~21MeV)$ and therapeutic dose levels (1~60 Gy) was measured. Furthermore, depth dose measurements carried out with alanine dosimeters were compared with ionization chamber measurements. As the results, the measured absorbed doses for shallow depth of initial electron energies above 15 MeV were higher by$2\~5\%$ than those calculated by nominal energy $C_E$ factors. This seems to be caused by low energy scattered beams generated from the scattering foil and electron cones of beam projecting device in medical linear accelerator.

  • PDF

Thermoluminescent Response of Thin LiF:Mg,Cu,Na,Si Detectors to Beta Radiation (얇은 LiF:Mg,Cu,Na,Si 검출기의 베타선장에 대한 TL 반응)

  • Nam, Y.M.;Kim, J.L.;Chang, S.Y.;Cho, H.W.;Kim, H.J.
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.1
    • /
    • pp.39-43
    • /
    • 1999
  • Thermoluminescent (TL) response characteristics of a thin LiF:Mg,Cu,Na,Si Teflon detectors have been studied for use in beta radiation detection. The detectors were fabricated from a mixture of LiF:Mg,Cu,Na,Si phosphor and Teflon powder which was molded into a thin disk form of $50mg/cm^2$ thickness. These detectors were irradiated to beta fields of $^{147}Pm,\;^{204}Tl\;and\;^{90}Sr/^{90}Y$ sources with a covering of Kapton foil ($2mg/cm^2$) and photon irradiation was carried out with a $^{137}Cs$ source at the Korea Atomic Energy Research Institute (KAERI). Batch uniformity was estimated to be 4.7% and the beta dose response presented linear relationship from 0.1 mGy to 100 Gy. The beta energy responses of thin detectors normalized to $^{137}Cs$ were presented as 0.46, 1.09 and 1.06 for $^{147}Pm,\;^{204}Tl\;and\;^{90}Sr/^{90}Y$ beta rays, respectively. The evaluated values for angular responses were $0.93{\pm}0.03\;(^{147}Pm),\;0.94{\pm}0.04\;(^{204}Tl),\;and\;0.92{\pm}0.05\;(^{90}Sr/^{90}Y)$. The results satisfied well a proposed ISO Standard for beta ray dosimeters.

  • PDF

Characterization of Radiation Field in the Steam Generator Water Chambers and Effective Doses to the Workers (증기발생기 수실의 방사선장 특성 및 작업자 유효선량의 평가)

  • Lee, Choon-Sik;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.4
    • /
    • pp.215-223
    • /
    • 1999
  • Characteristics of radiation field in the steam generator(S/G) water chamber of a PWR were investigated and the anticipated effective dose rates to the worker in the S/G chamber were evaluated by Monte Carlo simulation. The results of crud analysis in the S/G of the Kori nuclear power plant unit 1 were adopted for the source term. The MCNP4A code was used with the MIRD type anthropomorphic sex-specific mathematical phantoms for the calculation of effective doses. The radiation field intensity is dominated by downward rays, from the U-tube region, having approximate cosine distribution with respect to the polar angle. The effective dose rates to adults of nominal body size and of small body size(The phantom for a 15 year-old person was applied for this purpose) appeared to be 36.22 and 37.06 $mSvh^{-1}$) respectively, which implies that the body size effect is negligible. Meanwhile, the equivalent dose rates at three representative positions corresponding to head, chest and lower abdomen of the phantom, calculated using the estimated exposure rates, the energy spectrum and the conversion coefficients given in ICRU47, were 118, 71 and 57 $mSvh^{-1}$, respectively. This implies that the deep dose equivalent or the effective dose obtained from the personal dosimeter reading would be the over-estimate the effective dose by about two times. This justifies, with possible under- or over- response of the dosimeters to radiation of slant incidence, necessity of very careful planning and interpretation for the dosimetry of workers exposed to a non-regular radiation field of high intensity.

  • PDF

The Influence of Volume Effect in 2D-array Ion Chamber on the Measurement of IMRT Dose Distribution (2차원 배열형 이온함의 부피효과가 세기조절방사선치료의 선량분포 측정에 미치는 영향)

  • Kim, Sung Joon;Lee, Seoung Jun;Park, In Kyu;Lee, Jeong Eun;Park, Shin Hyung;Seol, Ki Ho;Kim, Jae Chul
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.41-47
    • /
    • 2013
  • We evaluated the influence of volume effect on the measurement of IMRT dose distribution by comparing a 2D-array ion chamber and other dosimeters. Matrix phantom which is a 2D-array ion chamber having volume effect was compared with beam image system and film for the measurement of dose distribution. Five intensity-modulated radiation therapy plans were created using five fields in thevirtual phantom. The measured dose distribution was compared with the calculated one by radiation treatment planning system and analysis program. We evaluated the conformity of dose distribution by calculating correlation coefficients and gamma values. The highest error rate of 1.3% was associated with matrix phantom in which volume effect in small field sizes was substantial.

A Study on the Thyroid Dose High-Energy Radiation Therapy of Lung Cancer (폐암 고에너지 방사선치료 시 갑상선 피폭에 관한 연구)

  • Yang, Oh-Nam;Lim, Cheong-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.6
    • /
    • pp.297-302
    • /
    • 2015
  • High-energy medical linear accelerator on the dose to the thyroid cancer during radiotherapy were evaluated using optical stimulation luminescence dosimeters(OSLD) using. Scattered's influence in the case of 3D-CRT 25.4 mSv, 28.8 mSv, 31.3 mSv, 26.5 mSv, 27.4 mSv 5 times with an average 27.9 mSv, in the IMRT 46.8 mSv, 43.2 mSv, 42.3 mSv, 41.5 mSv, 44.1 mSv to five times the average of 43.6 was the result of mSv. In the case of light neutron dosimetry results 3D-CRT 3 mSv, 3 mSv, 3.4 mSv, 3.5 mSv, 3.1 mSv to five times the average 3.2 mSv, in the IMRT 5.1 mSv, 4.8 mSv, 4.2 mSv, 4.8 mSv, 4.9 mSv, to five times the average of 4.7 was the result of mSv. Both parties and the light scattered neutrons were significantly appreciated compared to IMRT 3D-CRT. Treatment of cancer using radiation workers, as in this study, and that a significant amount of scattered rays in the adjacent normal tissues during radiation therapy using energy assessment to influence by fully aware of this information is necessary for the exposure reduction efforts the feed.

A Study on Characteristic of Glass Dosimeter According to Graded Change of Tube Current (유리선량계의 단계별 관전류량 변화에 따른 특성연구)

  • Son, Jin-Hyun;Kim, Seong-Ho;Mun, Hyun-Jun;Kim, Lyun-Kyun;Son, In-Hwa;Kim, Young-Jun;Min, Jung-Whan;Kim, Ki-Won
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.135-141
    • /
    • 2014
  • This study was evaluated the linearity and reproducibility according to dose, and reproducibility according to delay time by changing tube current amount (5 mAs, 10 mAs, 16 mAs, 20 mAs, 25 mAs, 32 mAs respectively, which are low energy radiations) using Glass Dosimeter (GD) and piranha semiconductor dosimeter which are used for measuring exposure dose. Measurements of radiation dose were performed using external detector of piranha 657 which is multi-function QA device (RTI Electronic, Sweden). Conditions of measurement were 80 kVp, SSD 100 cm and exposure region is $10cm{\times}10cm$. Glass dosimeter was exposed to radiation. Twenty-four glass dosimeters were divided into six groups (5 mAs, 10 mAs, 16 mAs, 20 mAs, 25 mAs, 32 mAs respectively), then measured. This study was resulted by measuring the linearity and reproducibility according to change of tube current in low energy field. In dose characteristic of GD, this study could be useful as previous study with regard to dose characteristic according to change of tube voltage in low energy field.

Effects of Breast Dose on Plain Abdominal Position (복부 방사선검사 자세가 유방선량에 미치는 영향)

  • Joo, Young-Cheol;Kim, Sheung-Hyuk
    • Journal of radiological science and technology
    • /
    • v.43 no.3
    • /
    • pp.155-159
    • /
    • 2020
  • The purpose of this study is to investigate the effect of posture changes(Anteroposterior projection, Posteroanterior projection) in the plain abdominal examination on breast dose and to examine its clinical usefulness. This study was used a human body phantom and a glass dosimeter. Glass dosimeters were directly inserted from the center and outside of medial and lateral. In this study, the deep dose was measured in the right breast and the surface dose in the left breast. During the abdominal examination, the central X-ray incident point was perpendicularly incident to the image receptor 5 cm above the iliac crest. The exposure parameters were 82 kVp, 320 mA, 50 ms, x-ray field size 14×17 inch The distance between the center X-ray and the detector was fixed at 110 cm, and only the top two AEC chambers were used. As a result of this study, the medial and lateral side doses of the right breast were 535.73±30.68 μGy and 414.46±33.52 μGy for erect AP, and 145.80±18.52 μGy and 148.76±12.92 μGy in erect PA. The superficial breast dose was 754.00±68.36 μGy on the medial side and 674.06±45.58 μGy on the lateral side in the erect AP, 70.66±7.98 μGy on the medial side, and 86.46±15.35 μGy on the lateral side in the erect PA. There was a statistically significant difference in the difference between the mean values of the medial and lateral side doses in the deep and superficial areas of the breast according to the postural change (p <0.01). As a result of this study, If the abdominal radiography was examined in the PA position, the dose reduction effect was 72.78% on the medial side, 64.10% on the lateral side of the deep breast, 90.62% on the medial side, and 87.17% on the lateral side of the superficial breast compared to the AP position.