Impact of testicular shielding in liposarcoma to scrotum by using radio-photoluminescence glass dosimeter (RPLGD): a case report

  • Oonsiri, Puntiwa;Saksornchai, Kitwadee;Suriyapee, Sivalee
    • Radiation Oncology Journal
    • /
    • 제36권3호
    • /
    • pp.248-253
    • /
    • 2018
  • Radiation protection in the scrotum to reduce the risk of genetic effect in the future is very important. This study aimed to measure the scrotal dose outside the treatment fields by using the radio-photoluminescence glass dosimeter (RPLGD). The characteristics of RPLGD model GD-302M were studied. Scattered dose to scrotum was measured in one liposarcoma case with the prescribed dose of 60 Gy. RPLGDs were placed in three different locations: one RPLGD was positioned at the posterior area which closer to the scrotum, and the other two RPLGDs were placed between the penis and the scrotum. Three RPLGDs were employed in each location. The scattered doses were measured in every fraction during the whole course of treatment. The entire number of 100 RPLGDs showed the uniformity within ±2%. The signal from RPLGD demonstrated linear proportion to the radiation dose (r = 0.999). The relative energy response correction factor was 1.05. The average scrotal dose was 4.1 ± 0.9 cGy per fraction. The results presented a wide range since there was a high uncertainty during RPLGD placement. The total scrotal dose for the whole course of treatment was 101.9 cGy (1.7% of the prescribed dose). The RPLGD model GD-302M could be used to measure scattered dose after applying the relative energy correction factor.

치료용 전자선 계측을 위한 1차원 광섬유 방사선량계의 제작 및 특성분석 (Fabrication and Characterization of a One-dimensional Fiber-optic Dosimeter for Electron Beam Therapy Dosimetry)

  • 장경원;조동현;신상훈;유욱재;전재훈;이봉수;문주현;박병기
    • 한국의학물리학회지:의학물리
    • /
    • 제19권4호
    • /
    • pp.285-290
    • /
    • 2008
  • 본 연구를 통하여 개발된 1차원 광섬유 방사선량계는 PMMA 팬텀에 10개의 광섬유 방사선 선세를 배열하여 제작하였다. 1차원 광섬유 방사선량계를 구성하는 각각의 광섬유 방사선 센서는 플라스틱 광섬유와 유기섬광체로 구성되어 있다. 각각의 유기섬광체는 치료용 선형가속기에서 발생되는 고 에너지 방사선에 의해 섬광빛을 방출하고 방출된 섬광빛은 플라스틱 광섬유를 통하여 광 계측장비인 다채널의 포토다이오드 증폭 시스템으로 전달된다. 본 연구에서는 1차원 광섬유 방사선량계를 이용하여 에너지와 조사야의 크기에 따른 치료용 전자선의 1차원적 선량분포를 측정하였고 섬광체의 광신호 측정에 있어 방해요소로 작용하는 체렌코프 빛을 전자선의 입사각도에 따라 계측 및 분석하였다. 또한 PMMA 팬텀의 깊이에 따른 선량을 계측함으로써 3차원적 심부선량백분율을 측정하였고 그에 따른 등선량곡선을 도시화하였다. 본 연구를 통하여 개발된 1차원 광섬유 방사선량계는 고 분해능, 실시간 측정, 쉬운 보정 등 많은 장점을 가지고 있다.

  • PDF

저(低)에너지 X-선장(線場)에서 필름배지에 의한 개인피폭선량(個人被曝線量)의 결정(決定) (Determination of Personnel Exposures in the Lower Energy Ranges of X-Ray by Photographic Dosimeter)

  • 하정우;김장열;서경원
    • Journal of Radiation Protection and Research
    • /
    • 제11권1호
    • /
    • pp.57-64
    • /
    • 1986
  • 우라늄, 플루토늄 및 그 자핵종(子核種)으로부터 방출(放出)되는 저(低)에너지감마선(線) 또는 저(低)에너지영역(領域)의 X-선(線)스펙트럼으로부터의 필름배지 개인피폭선량해석(個人被曝線量解析) 및 평가(評價)에 필요(必要)한 기술자료(技術資料)를 제공(提供)하였다. 필름배지는 한국핵연료개발공단(韓國核燃料開發公團)(현(現) 한국(韓國)에너지연구소(硏究所))에서 개발(開發)한 것이며, 저(低)에너지표준선원(標準線源)은 방사선량강도(放射線量强度)의 손실(損失)을 최소(最少)로 유지(維持)하면서 가능(可能)한 한 X-선(線)스펙트럼폭(幅)을 금속(金屬)필터로 좁게 줄인 X-선(線)을 이용(利用)하였다. 그 결과(結果) 얻은 X-선(線)에너지는 49 keV, 154 keV 및 256 keV 이었으며, 이 값은 Kramer의 이론적계산결과(理論的計算結果)와 잘 일치(一致)하였다. 이들 에너지 군별(群別) X-선(線)의 필름광학밀도(光學密度)와 선량(線量)과의 관계(關係)는 Matrix 법(法)으로 해석(解析)하여 측정광학밀도(測定光學密度)로부터 저(低)에너지 X-선(線)의 개인피폭선량(個人被曝線量)을 직접(直接) 환산(換算)할 수 있게 되었다. 이 결과(結果)는 국내(國內) 방사선작업(放射線作業) 종사자(從事者)들의 개인피폭선량측정자료(個人被曝線量測定資料)의 균질성(均質性) 향상(向上)에 기여(寄與)하게 될 것이다.

  • PDF

영상의학과에서 사용되는 광자극 형광선량계와 전자식 개인선량계의 방향 의존성 비교 (The comparison of angular dependence for optical stimulated luminescence dosimeter(OSLD) and electronic personal dosimeter(EPD) used in Diagnostic Radiology)

  • 권순무;박정규;김부순
    • 디지털콘텐츠학회 논문지
    • /
    • 제16권3호
    • /
    • pp.463-470
    • /
    • 2015
  • 최근 개인선량계로 사용이 증가하고 있는 수동형 선량계인 OSLD와 능동형 선량계인 EPD의 상대 반응도(relative response), 측정 불확도(uncertainty of measurement)를 계산하여 방향의존성(angular dependence)을 비교, 분석하였다. OSLD는 수평, 수직방향의 $0^{\circ}{\sim}{\pm}90^{\circ}$ 범위에서 평균 상대 반응도는 0.97, 0.95의 작은 변화를 보였고 방향의존성에 대한 불확도는 0.65, 0.62로 전체 불확도에 미치는 영향은 미미한 것으로 판단되었다. EPD는 $0^{\circ}{\sim}{\pm}60^{\circ}$ 범위에서 수평, 수직방향 평균 상대 반응도는 0.94, 0.97로 확인되어 IEC 61526 규정을 만족하였다. 방향의존성에 대한 불확도는 수평, 수직방향에서 0.44, 0.40로 전체 불확도에 미치는 영향은 미미하였다. 그러나 수평방향에서 $+90^{\circ}$, $-90^{\circ}$ 방향의 상대 반응도는 0.60, 0.37이고 수직방향에서 $+90^{\circ}$ 방향의 반응도는 0.06으로 반응도의 큰 변화를 관찰할 수 있었다. OSLD의 방향 의존성은 $0^{\circ}{\sim}{\pm}90^{\circ}$ 범위까지 EPD에 비해 우수하였으며 EPD의 경우 구조적 특징으로 반응도가 급변하는 특정방향이 존재하였다. 따라서 수동형선량계와 보조선량계의 병행사용이 개인피폭선량측정의 정확도를 기할 수 있을 것으로 판단된다.

Glass dosimeter와 PCXMC Program을 이용한 소아피폭선량 측정 및 분석 (Measurement and Analysis of Pediatric Patient Exposure Dose Using Glass dosimeter and a PC-Based Monte Carlo Program)

  • 김영은;이정화;홍선숙;이관섭
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.9-14
    • /
    • 2012
  • Exposed dose of young child should be managed necessarily. Young child is more sensitive than adult of a Radioactivity, especially, and lives longer than adult. Must reduce exposed dose which follows The ALARA(As Low As Reasonably Achievable)rule is recommended by ICRP(International Commission on Radiological Protection)within diagnostic useful range. Therefore, We have to prepare Pediatric DRL(Diagnostic Reference Level) in Korea as soon as possible. Consequently, in this study, wish to estimate organ dose and effective dose using PCXMC Program(a PC-Based Monte Carlo Program), and measure ESD(Entrance surface dose)and organ dose using Glass dosimeter, and then compare with DRL which follows EC(European Commission)and NRPB(National Radiological Protection Board). Using glass dosimeter and PCXMC programs conforming to the International Committee for Radioactivity Prevention(ICRP)-103 tissue weighting factor based on the item before the organs contained in the Chest, Skull, Pelvis, Abdomen in the organ doses and effective dose and dose measurements were evaluated convenience. In a straightforward way to RANDO phantom inserted glass dosimeter(GD352M)by using the hospital pediatric protocol, and in a indirect way was PCXMC the program through a virtual simulation of organ doses and effective dose were calculated. The ESD in Chest PA is 0.076mGy which is slightly higher than the DRL of NRPB(UK) is 0.07mGy, and is lower than the DRL of EC(Europe) which is 0.1mGy. The ESD in Chest Lateral is 0.130mGy which is lower than the DRL of EC(Europe) is 0.2mGy. The ESD in Skull PA is 0.423mGy which is 40 percent lower than the DRL of NRPB(UK) is 1.1mGy and is 28 percent lower than the DRL of EC(Europe) is 1.5mGy. The ESD in Skull Lateral is 0.478mGy which is half than the DRL of NRPB(UK) is 0.8mGy, is 40 percent lower than the DRL of EC(Europe) is 1mGy. The ESD in Pelvis AP is 0.293mGy which is half than the DRL of NRPB(UK) is 0.60mGy, is 30 percent lower than the DRL of EC(Europe)is 0.9mGy. Finally, the ESD in Abdomen AP is 0.223mGy which is half than the DRL of NRPB(UK) is 0.5mGy, and is 20 percent lower than the DRL of EC is 1.0mGy. The six kind of diagnostic radiological examination is generally lower than the DRL of NRPB(UK)and EC(Europe) except for Chest PA. Shouldn't overlook the age, body, other factors. Radiological technician must realize organ dose, effective dose, ESD when examining young child in hospital. That's why young child is more sensitive than adult of a Radioactivity.

  • PDF

전자개인선량계(EPD)의 외부피폭방사선량 평가 성능분석 (Performance Analysis of Electronic Personal Dosimeter(EPD) for External Radiation Dosimetry)

  • 이병일;김태진;임영기
    • Journal of Radiation Protection and Research
    • /
    • 제40권4호
    • /
    • pp.261-266
    • /
    • 2015
  • 원전에서 방사선작업종사자의 개인선량평가에 보조선량계로 사용되고 있는 전자개인선량계(EPD)의 성능이 지속적으로 개선되고 있어, EPD의 외부피폭방사선량 평가성능을 확인하고자 해외 EPD 운영 사례, 국내 현황조사, EPD 원전 현장실험 등을 다각적으로 수행하였다. 원전현장에서 실시한 성능검증 시험결과는 IAEA와 EURADOS가 공동으로 실시한 EPD 비교검증(IAEA-TECDOC-1564) 결과와 유사하였다. 또한 국내원전 피폭방사선량 비교결과(5년간 EPD/TLD 값)는 일본 JAPC의 비교결과(EPD/필름뱃지 값)와 유사한 경향성을 보였으며, TLD보다 EPD가 피폭방사선량을 보수적으로 평가하는 것을 확인하였다. EPD의 성능 중 가장 우려되는 것이 기능적 오류발생이다. 기술적 발전에 힘입어 EPD의 오류발생이 지속적으로 개선되고 있음을 국내원전 분석자료 및 INFO의 오류경향 분석사례에서 확인할 수 있다. 결론적으로 성능검증 프로세스 구축 및 기능적 오류 대비방안을 체계적으로 마련할 경우 EPD의 성능은 TLD와 비교해서 손색이 없을 것으로 판단된다.

방사선근접치료 분야의 선량 측정을 위해 제조된 Lead(II) Iodide 선량계의 적용가능성 연구 (The Study on Applicability of Manufactured Lead(II) Iodide Dosimeter for Dose Measurement in Brachytherapy)

  • 양승우;한무재;박성광
    • 한국방사선학회논문지
    • /
    • 제15권6호
    • /
    • pp.789-794
    • /
    • 2021
  • 근접방사선치료는 방사선동위원소를 신체 내부에 넣어 종양에 방사선을 집중적으로 조사하는 치료법이다. 근접방사선 치료는 고선량율의 방사선동위원소 선원을 사용하기 때문에 정확한 선원의 위치 및 선량등을 파악하는 것이 매우 중요하다. 하지만 임상에서는 ruler, autoradiograph등을 통하여 육안으로 부정확하게 평가하는 실정이다. 이에 본 연구에서는 Lead(II) Iodide(PbI2) 물질을 사용하여 방사선근접치료에 사용할 수 있는 선량계를 개발하고, 재현성, 선형성, PID 항목을 분석하여 적용가능성을 평가하였다. 재현성 평가 결과, RSD 값은 1.41%로 평가기준 1.5%를 만족하였다. 선형성 평가결과, R2값은 0.9993으로 평가기준 0.9990을 만족하였다. PID 평가 결과 50% 선량 감약지점에서 거리의 역자승 법칙의 이론값과 비교하여 0.06 cm의 차이만을 나타내었다. 본 실험에서 제작된 선량계는 모든 평가에서 기준치를 만족하는 결과값을 나타내어 방사선근접치료 영역에서의 선량계 적용 가능성이 충분한 것으로 판단된다.

Flattening Filter Free Beam의 정도관리를 위한 곡면선량계 가능성 연구 (A study of Curved Dosimeter for Flattening Filter Free Beam Quality Assurance Evaluation using Curved Dosimeter in Radiotherapy)

  • 한무재;신요한;정재훈;허승욱;김교태;허예지;조흥래;박성광
    • 한국방사선학회논문지
    • /
    • 제13권1호
    • /
    • pp.119-124
    • /
    • 2019
  • 최근 도입된 FFF 빔을 활용하는 방사선치료는 flattening filter에서 비롯되는 빔의 감쇠를 막을 수 있어 치료효율을 높일 수 있지만, 불균일한 단면적 선량분포에 대하여 정확한 정도관리가 구축되어 있지 않은 실정이다. 이에 본 연구에서는 광도전체 물질 $HgI_2$ 기반의 곡면 선량계를 제작하였으며, 성능을 검증하기 위하여 6 MV 광자에너지에서 재현성 및 선형성을 평가하였다. 또한 곡면 계측의 유용성을 나타내기 위하여 아크릴 필터를 적용한 FFF beam에서 평면 기판과 곡면 기판 상에서 계측되는 신호를 비교하였다. 그 결과 Unit cell 선량계의 재현성은 SE 0.613%, 선형성은 R-sq 0.9999로 나타났으며, line array 곡면 선량계의 유용성 평가는 평면 기판에서 23.337%, 곡면 기판에서 12.264%로 11.073%p 감소된 신호 차이를 보였다.

방사선 근접치료의 디지털 정도관리를 위한 Lead (II) Oxide 선량계 성능 평가 (Performance Evaluation of Lead (II) Oxide Dosimeter for Digital Quality Assurance in Brachytherapy)

  • 한무재;양승우;박성광
    • 한국방사선학회논문지
    • /
    • 제15권4호
    • /
    • pp.429-435
    • /
    • 2021
  • 방사선 근접치료에서 잘못된 선원의 위치는 정상조직에 과도한 선량을 유발할 수 있기 때문에 선원의 위치 정확성 평가는 필수적이다. 이에 본 연구에서는 기존 아날로그 검증방식을 개선시키기 위해 lead (II) oxide (PbO) 기반의 디지털 선량계에 대한 기초연구를 수행하였다. 이에 다결정 PbO 선량계를 제작하였고 Ir-192 선원에 대한 계측 성능을 평가하였다. 그 결과 재현성은 상대표준편차가 0.82%로 평가 기준 1.5% 이내를 만족하였다. 선형성은 선형함수 R2이 0.9998로 우수한 결과를 보였다. 거리 의존성 평가의 경우, 거듭제곱함수 R2은 PbO에서 0.9855, diode에서 0.9974를 보였고, 전체 평균차이는 PbO에서 1.66%, diode에서 2.18% 차이를 보였다. 본 연구는 다결정 PbO 선량계의 Ir-192 선원에 대한 기초 검출성능을 제시하며, 방사선 계측분야에서 기초자료를 제공할 수 있다.

전자선 Quality Assurance 선량계 개발을 위한 TlBr 물질의 검출성능 평가 (Evaluation of Detection Performance of TlBr Materials for the Development of Electron Beam Quality Assurance Dosimeters)

  • 양승우;박성광
    • 한국방사선학회논문지
    • /
    • 제16권5호
    • /
    • pp.513-518
    • /
    • 2022
  • 전자선의 정도관리(quality assurance, QA)는 정확한 방사선 치료를 위해 정기적으로 이루어져야한다. 하지만 임상에서 사용되는 QA도구는 X선 위주로 설계되어 있어서 전자선 전용의 QA 선량계가 요구된다. 이에 본 연구에서는 방사선 검출 효율이 뛰어난 브롬화탐륨 물질을 전자선 센서로 활용하여 전자선 검출성능을 측정하고 전자선 전용의 QA 선량계로 적용가능할지를 평가하였다. 평가항목은 재현성, 선형성, 선량률 의존성이며, 선형가속기의 6 MeV, 9 MeV 에너지에서 평가하였다. 재현성 결과, 6 MeV에서는 최대 0.92%, 9 MeV에서는 최대 1.15%의 출력변화를 보여주었다. 선형성 결과평가, 결정계수 R2이 0.9998로 제시되었다. 선량률 의존성 평가 결과, 6 MeV에서는 상대표준편차 0.51%, 9 MeV에서는 상대표준편차 1.07%의 선량률 의존성이 제시되었다. 본 연구에서 제작한 TlBr 센서는 재현성, 선형성, 선량률 의존성의 모든 평가기준을 만족하는 검출성능을 보여준다. 이러한 결과들은 TlBr 선량계가 전자선 전용 QA 선량계로 적용 가능한 것을 의미한다.