• Title/Summary/Keyword: dose reduction factor

Search Result 154, Processing Time 0.022 seconds

The Experiment of Grid Characteristics for High-voltage Radiography of Chest (흉부촬영시 관전압과 선질에 따른 적절한 격자의 선택을 위한 실험)

  • Kim, Jung-Min;Ahn, Bong-Seon
    • Journal of radiological science and technology
    • /
    • v.15 no.2
    • /
    • pp.31-36
    • /
    • 1992
  • Grids can improve the diagnostic quality of chest radiography by trapping the greater part of scattered radiation thus providing more detailed. chest radiographic images. It is most effective mathod of reduce the scatter ratio but must increase the expour factor. The benefit of use of grid is improve the contrast and the loss is increase of patient dose. In chest radiography especially hard quality high voltage radiography it will have to be considered to select the optimum grid with view point of benefit and loss. In this experiment, author got some result of characteristics about 4 different grids with film method. 1. There was no difference the scatter ratio in case of no grid and the scatter ratio was about 60%. 2. 16 : 1 grid was excellent of scatter reduction factor in high voltage chest radiography, next was 10 : 1, CROSS, MICRO FINE grid have low scatter reduction rate compare to 16:1, 10:1 grid. 3. The bucky factor of CROSS grid in accordance of kVp was find out the highest in 4 grids, on the contraly 10 : 1 grid was profitable to the exposure does. 4. With careful consideration in the point of scatter reducion rate and bucky factor, author suggest the 10 : 1 linear grid on the use of chest radiography in $80{\sim}120\;kVp$, 16 : 1 grid in $120{\sim}140\;kVp$.

  • PDF

Development of the Numerical Guide for Cost-Benefit Analysis of Occupational Radiation Exposure In the Korean Next Generation Reactor

  • Sohn, Ki-Yoon;Kang, Chang-Sun
    • Nuclear Engineering and Technology
    • /
    • v.29 no.1
    • /
    • pp.78-84
    • /
    • 1997
  • The specific purpose of this study is to develop the numerical guide for the cost-benefit analysis of ORE ($/person-Sv reduction) to meet the criterion of ALARA in the design stage of the KNGR. In deriving the guide, the risk factor which is defined by the risk to unit collective radiation exposure dose (deaths/person-Sv) and the monetary value of human life ($/death) are required. The risk factor has been estimated from various clinical data accumulated for a number of years and continuously modified. And the monetary value of human life is usually quantified using the human capital approach. In this study, the risk to radiation exposure perceived by a group of people is investigated through an extensive poll survey conducted among university students in order to modify the existing risk factor for radiation exposure. And in evaluating the monetary value of human life, the QOL factor is introduced in order to incorporate the degree of public welfare or quality of life. As a result of study, a value within the range of 151, 000~172, 000 dollars per person-Sv reduction is recommended as the appropriate interim numerical guide for cost-benefit analysis of ORE to meet the criterion of ALARA in the design stage of the KNGR. A poll survey was also conducted in order to see whether the public acceptance cost of nuclear power should be incorporated in developing the guide, and the result of study shooed that such a cost does not need to be considered.

  • PDF

Effects on Patient Exposure Dose and Image Quality by Increasing Focal Film Distance in Abdominal Radiography (복부 일반촬영시 초점-필름간거리 변화가 피폭선량 및 화질에 미치는 영향)

  • Kim, You-Hyun;Kwon, Soo-Il
    • Journal of radiological science and technology
    • /
    • v.21 no.1
    • /
    • pp.52-58
    • /
    • 1998
  • We can and must improve the diagnostic images using available knowledge and technology. At the same time we must strive to reduce the patient's integral and entrance radiation dose. Reducing the integral dose to the patient during the radiologic procedure is a primary concern of the patient, especially the pediatric patient, the radiologist and the technologist. A 100cm focal film distance generally is used for most over-table radiography. The early x-ray tubes and screen film combinations required long exposures, which often resulted in motion artifacts. But nowaday, we have the generators and x-ray tubes that can deliver the energy necessary in a very short time and the receptors that can record the information just as rapidly. And, we performed this studies to evaluate the patient exposure dose and the image quality by increasing focal film distance in diagnostic radiography. There are many factors which affected to exposure factor, but we studied to verify of FFD increase, only. Effect of increasing the focal film distance to a 140 cm distance was tested as follows; 1. The focal film distances were set at 100, 120, and 140cm. 2. A 18cm acryl(tissue equivalent) phantom was placed on the table top. 3. An Capintec 192 electrometer with PM 05 ion chamber was placed at the entrance surface of the phantom, and exposure were made at each focal film distances. 4. The procedure was repeated in the same manner as above except the ion chamber was placed beneath the phantom at the film plane. 5. Exit exposure were normalize to 8mR for each portions of the experiment. Based on the success of the empirical measurements, a detailed mathematical analysis of the dose reduction was performed using the percent depth dose data. The results of this study can be summerized as followings ; 1) Increasing FFD from 100 cm to 140 cm, we would create a situation that would have a significant effect on the overall quality of radiograph and achive the 17.42% reduction of entrance dose and the 18.95% reduction of integral dose that the patient receives. 2) Thickness of Al step wedge for equal film density increased with the long distance. 3) Increasing FFD, Magnification of image was lowered. 4) Resolution of image also increased with the FFD. As the results described above, we strongly recommend using the long FFD to provide better information for our patients and profession in abdomen radiographic studies.

  • PDF

A comparative study of radioprotection with Callophyllis japonica extract and amifostine against lethal whole body gamma irradiation in mice

  • Shin, Tae-Kyun;Kim, Hee-Chul;Kim, Jeong-Tae;Ahn, Mee-Jung;Moon, Chang-Jong;Hyun, Jin-Won;Jee, Young-Heun;Lee, Nam-Ho;Park, Jae-Woo
    • Advances in Traditional Medicine
    • /
    • v.10 no.1
    • /
    • pp.1-6
    • /
    • 2010
  • The efficacy of the radioprotective effect of Callophyllis japonica ethyl acetate (CJEA) extract was studied by comparing it to that of amifostine, a well-known radioprotective agent, and by evaluating the dose reduction factor, an indicator of radioprotective efficacy. Pretreatment with CJEA extract (100 mg/kg body weight) prior to receiving 12 Gy irradiation significantly improved the survival of jejunal crypts at 3.5 day post-irradiation, but attenuated the level of malondialdehyde compared to vehicle alone (P < 0.01). A similar gastroprotective effect was also obtained in the amifostine-treated irradiated group (P < 0.01). The efficacy of the radioprotective effect was further confirmed by the dose reduction factor, 1.41. Collectively, these results suggest that CJEA extract is a useful radioprotectant whose efficacy is similar to that of amifostine and whose radioprotective mechanism is in part the reduction of lipid peroxidation caused by gamma irradiation.

Safety Assessment of Nuclear Waste Incineration Process by Estimating Radiation Dose of Workers and Residential Individuals (원자력폐기물 소각공정에서의 작업자 및 인근주민의 피폭선량에 따른 안전성 평가)

  • 서용칠
    • Journal of the Korean Society of Safety
    • /
    • v.8 no.4
    • /
    • pp.165-174
    • /
    • 1993
  • For the safety assessment of the demonstration-scale incineration plant for treating the combustible radioactive wastes, radiation doses of a worker and a residential individual were estimated. The demonstration plant showed a good performance of trial-burn tests using non-radioactive tracers with resulting In high mass reduction of around 40 times and very low emmission of dusts through a stack, which promised a high decontamination factor in an order of 10$^{7}$ . Based on the result s obtained from the trial-burns in the process, the estimation of radiation dose for workers and general publics near the plant was made using dose pathway calculation theories. The parametric values for calculation were selected from design and operational results of the process and from more conservative conditions In reference data. The estimated annual doses for workers and residential indivisuals were 3.07 $\times$ 10$^{-4}$ and 4.35 X 10$^{-8}$ $\mu$Sv/y, respectively, which were high enough to operate the process when comparing with the allowable dose limit in the regulation. The dose calculation models were quite applicable with showing an excellent safety for the process.

  • PDF

High Dose of FGF-2 Induced Growth Retardation via ERK1/2 De-phosphorylation in Bone Marrow-derived Mesenchymal Stem Cells

  • Shim, Kwang Yong;Saima, Fatema Tuj;Eom, Young Woo
    • Biomedical Science Letters
    • /
    • v.23 no.2
    • /
    • pp.49-56
    • /
    • 2017
  • Fibroblast growth factor (FGF)-2 is one of the most effective growth factors to increase the growth rate of mesenchymal stem cells (MSCs). Previously, we reported that low dose of FGF-2 (1 ng/ml) induced proliferation of bone marrow-derived mesenchymal stem cells (BMSCs) through AKT and ERK activation resulting in reduction of autophagy and senescence, but not at a high dose. In this study, we investigated the effects of high dose FGF-2 (10 ng/ml) on proliferation, autophagy and senescence of BMSCs for long term cultures (i.e., 2 months). FGF-2 increased the growth rate of BMSCs in a dose dependent manner for a short term (3 days), while during long term cultures (2 months), population doubling time was increased and accumulated cell number was lower than control in BMSCs when cultured with 10 ng/ml of FGF-2. 10 ng/ml of FGF-2 induced immediate de-phosphorylation of ERK1/2, expression of LC3-II, and increase of senescence associated ${\beta}$-galactosidase (SA-${\beta}$-Gal, senescence marker) expression. In conclusion, we showed that 10 ng/ml of FGF-2 was inadequate for ex vivo expansion of BMSCs because 10 ng/ml of FGF-2 induced growth retardation via ERK1/2 de-phosphorylation and induction of autophagy and senescence in BMSCs.

Dose Distributions in a Shielded Vaginal Cylinder using a HDR Co-60 Source (고선량 Co-60 선원이용시 차폐된 질 원주기구의 영향)

  • 김진기;김정수;김형진;권형철;강정구
    • Progress in Medical Physics
    • /
    • v.8 no.1
    • /
    • pp.37-45
    • /
    • 1997
  • The present work is determine to the dose distribution reduced by the insertion of a shielded into a vaginal cylinder around a $\^$60/CO source in brachytherapy, and to the source calibration. It was investigated by measuring the relative dose around a 2.5cm diameter shielded vaginal cylinder in a polystyrene phantom by use of a ionization chamber. Measurements were made with the cylinder unshielded and 0.55cm thick 90$^{\circ}C$ lead shields inserted. Also, the dose distribution compared measurement value with calculation value according to the device manufacturer and the multiple-divided dose tables. A reduction in dose was observed on the unshielded side of the cylinder which increased with distance from the source and it does 4.4% within 1cm from the surface of the cylinder. On the shielded side of the cylinder, the dose at the surface is reduced to about 20.4% of its value without the shield. The effective attenuation factor entered for the 90$^{\circ}C$ lead shielded cylinder was average 0.2 in a $\^$60/CO moving source. In comparision with the dose calculation mathods, the multiple-divided dose tables are difference less than ${\pm}$4.1% with measured data in a $\^$60/Co source.

  • PDF

Weight Reduction Management of Patients with Idiopathic Intracranial Hypertension: A Case Series Report (특발성 두개내 고혈압 환자에서 체중 감량을 동반한 치료 증례 시리즈)

  • Jung Ah Lee;Yongho Lee;Hye Soon Park
    • Archives of Obesity and Metabolism
    • /
    • v.3 no.1
    • /
    • pp.43-48
    • /
    • 2024
  • Idiopathic intracranial hypertension (IIH) is characterized by increased intracranial pressure without detectable causes. Its main symptoms include headache, vision problems, and pulsatile tinnitus. Obesity is a major risk factor for IIH; therefore, weight reduction is required to ameliorate these symptoms in patients with obesity and IIH. We present four cases of obesity-related IIH whose symptoms improved through weight reduction. In three patients, the dose of IIH medications, such as acetazolamide, decreased. Based on these cases, we report that weight reduction contributes to the improvement of symptoms in patients with IIH as the main part of treatment. Further clinical research is necessary to evaluate the effects of weight reduction on IIH treatment in Korean patients.

A Case of Azathioprine Induced Severe Myelosuppression and Alopecia Totalis in IgA Nephropathy

  • Kim, Jae Choon;Kim, Ye Kyung;Hyun, Hye Sun;Park, Eu Jin;Kang, Hee Gyung;Ha, Il Soo;Cheong, Hae Il
    • Childhood Kidney Diseases
    • /
    • v.21 no.1
    • /
    • pp.35-39
    • /
    • 2017
  • Azathioprine is commonly used as immunosuppressive therapy for various inflammatory diseases including chronic glomerulonephritis. Myelosuppression is a common side effect of azathioprine, resulting in the need for dose reduction. However, severe pancytopenia or alopecia is not often encountered. Here, we report a case of severe myelosuppression, and alopecia totalis that occurred after azathioprine treatment in a patient with IgA nephropathy. A 10-year-old boy with IgA nephropathy was treated with oral deflazacort and later with azathioprine. After 4 weeks, the patient complained of hair loss, and despite a dose reduction in azathioprine, he developed bone marrow suppression and alopecia totalis in two weeks. The blood indices and alopecia of the patient had returned to normal after azathioprine withdrawal and 3 consecutive doses of granulocyte colony-stimulating factor. We suggest that physicians remain vigilant to the side effects of azathioprine. Unusual hair loss after azathioprine treatment might suggest a defect in the metabolism of the drug, warranting the discontinuation of azathioprine to prevent more severe side effects.

Temporal Change in Radiological Environments on Land after the Fukushima Daiichi Nuclear Power Plant Accident

  • Saito, Kimiaki;Mikami, Satoshi;Andoh, Masaki;Matsuda, Norihiro;Kinase, Sakae;Tsuda, Shuichi;Sato, Tetsuro;Seki, Akiyuki;Sanada, Yukihisa;Wainwright-Murakami, Haruko;Yoshimura, Kazuya;Takemiya, Hiroshi;Takahashi, Junko;Kato, Hiroaki;Onda, Yuichi
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.4
    • /
    • pp.128-148
    • /
    • 2019
  • Massive environmental monitoring has been conducted continuously since the Fukushima Daiichi Nuclear Power accident in March of 2011 by different monitoring methods that have different features together with migration studies of radiocesium in diverse environments. These results have clarified the characteristics of radiological environments and their temporal change around the Fukushima site. At three months after the accident, multiple radionuclides including radiostrontium and plutonium were detected in many locations; and it was confirmed that radiocesium was most important from the viewpoint of long-term exposure. Radiation levels around the Fukushima site have decreased greatly over time. The decreasing trend was found to change variously according to local conditions. The air dose rates in environments related to human living have decreased faster than expected from radioactive decay by a factor of 2-3 on average; those in pure forest have decreased more closely to physical decay. The main causes of air dose rate reduction were judged to be radioactive decay, movement of radiocesium in vertical and horizontal directions, and decontamination. Land-use categories and human activities have significantly affected the reduction tendency. Difference in the air dose rate reduction trends can be explained qualitatively according to the knowledge obtained in radiocesium migration studies; whereas, the quantitative explanation for individual sites is an important future challenge. The ecological half-lives of air dose rates have been evaluated by several researchers, and a short-term half-life within 1 year was commonly observed in the studies. An empirical model for predicting air dose rate distribution was developed based on statistical analysis of an extensive car-borne survey dataset, which enabled the prediction with confidence intervals. Different types of contamination maps were integrated to better quantify the spatial data. The obtained data were used for extended studies such as for identifying the main reactor that caused the contamination of arbitrary regions and developing standard procedures for environmental measurement and sampling. Annual external exposure doses for residents who intended to return to their homes were estimated as within a few millisieverts. Different forms of environmental data and knowledge have been provided for wide spectrum of people. Diverse aspects of lessons learned from the Fukushima accident, including practical ones, must be passed on to future generations.