• Title/Summary/Keyword: dose profile

Search Result 378, Processing Time 0.02 seconds

The Effect of Red-Yeast-Rice Supplement on Serum Lipid Profile and Glucose Control in Subjects with Impaired Fasting Glucose or Impaired Glucose Tolerance (공복 혈당장애 및 내당능장애자에서 홍국의 섭취가 혈중지질 및 혈당 조절에 미치는 영향)

  • Kang, Mi-Ran;Kim, Ji-Young;Hyun, Yae-Jung;Kim, Hyae-Jin;Yeo, Hyun-Yang;Song, Young-Duk;Lee, Jong-Ho
    • Journal of Nutrition and Health
    • /
    • v.41 no.1
    • /
    • pp.31-40
    • /
    • 2008
  • This study was aimed at evaluating the effect of red-yeast-rice supplementation on cholesterol-lowering and glucose control in subjects with impaired fasting glucose (IFT) or impaired glucose tolerance (IGT). We conducted a doubleblind, placebo-controlled study with 3 groups; placebo, low dose group (red yeast rice 210.0mg/capsule, 2.52g/day) and high dose group (red yeast rice 420.0mg/capsule, 5.04g/day), which were randomly assigned to subjects with impaired fasting glucose or impaired glucose tolerance. We measured fasting serum concentrations of total-, LDL-, HDL-cholesterol, triglyceride, glucose, insulin, free fatty acid (FFA) and 2 h oral glucose tolerence test (OGTT) before and after the supplementation. Both low dose and high dose groups had significant decrease in LDL cholesterol and atherogenic index (AI) compared with placebo group (p<0.05). Additionally, total and HDL cholesterol improved significantly in high dose group compared with placebo group (p<0.05). Fasting serum glucose decreased in test groups and increased in placebo group after intervention. However, it was not significant differences. In subjects which fasting blood glucose is more than 110mg/dL, fasting glucose had a tendency to decrease in high dose group (p<0.1) and Hemoglobin A1c (HbA1c) had significant decrease in low dose group (p<0.05), while insulin and HOMA-IR had a tendency to increase in placebo group after intervention. Mean changes of glucose related parameters (fasting glucose, insulin, HOMA-IR) compared with placebo group did not show significant differences. In conclusion, subjects with impaired fasting glucose or impaired glucose tolerance were significantly improved in serum lipid profile by red yeast rice supplementation without serious side effects. These are more effective in the case of a high dose. The effects of red yeast rice supplementation on glucose control were insignificant.

Study of Motion-induced Dose Error Caused by Irregular Tumor Motion in Helical Tomotherapy (나선형 토모테라피에서 불규칙적인 호흡으로 발생되는 움직임에 의한 선량 오차에 대한 연구)

  • Cho, Min-Seok;Kim, Tae-Ho;Kang, Seong-Hee;Kim, Dong-Su;Kim, Kyeong-Hyeon;Cheon, Geum Seong;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.119-126
    • /
    • 2015
  • The purpose of this study is to analyze motion-induced dose error generated by each tumor motion parameters of irregular tumor motion in helical tomotherapy. To understand the effect of the irregular tumor motion, a simple analytical model was simulated. Moving cases that has tumor motion were divided into a slightly irregular tumor motion case, a large irregular tumor motion case and a patient case. The slightly irregular tumor motion case was simulated with a variability of 10% in the tumor motion parameters of amplitude (amplitude case), period (period case), and baseline (baseline case), while the large irregular tumor motion case was simulated with a variability of 40%. In the phase case, the initial phase of the tumor motion was divided into end inhale, mid exhale, end exhale, and mid inhale; the simulated dose profiles for each case were compared. The patient case was also investigated to verify the motion-induced dose error in 'clinical-like' conditions. According to the simulation process, the dose profile was calculated. The moving case was compared with the static case that has no tumor motion. In the amplitude, period, baseline cases, the results show that the motion-induced dose error in the large irregular tumor motion case was larger than that in the slightly irregular tumor motion case or regular tumor motion case. Because the offset effect was inversely proportion to irregularity of tumor motion, offset effect was smaller in the large irregular tumor motion case than the slightly irregular tumor motion case or regular tumor motion case. In the phase case, the larger dose discrepancy was observed in the irregular tumor motion case than regular tumor motion case. A larger motion-induced dose error was also observed in the patient case than in the regular tumor motion case. This study analyzed motion-induced dose error as a function of each tumor motion parameters of irregular tumor motion during helical tomotherapy. The analysis showed that variability control of irregular tumor motion is important. We believe that the variability of irregular tumor motion can be reduced by using abdominal compression and respiratory training.

GafChromic Film Dosimetry for Stereotactic Radiosurgery with a Linear Accelerator (선형가속기를 이용한 정위방사선 치료 시 GafChromic Film을 이용한 선량측정)

  • Han Seung Hee;Cho Byung Chul;Park Suk Won;Oh Do Hoon;Park Hee Chul;Bae Hoon Sik
    • Radiation Oncology Journal
    • /
    • v.21 no.2
    • /
    • pp.167-173
    • /
    • 2003
  • Purpose: The purpose of this study was to evaluate whether a GafChromic film applied to stereotactic radiosurgery with a linear accelerator could provide information on the value for acceptance testing and quality control on the absolute dose and relative dose measurements and/or calculation of treatment planning system. Materials and methods: A spherical acrylic phantom, simulating a patient's head, was constructed from three points. The absolute and relative dose distributions could be measured by inserting a GafChromic film into the phantom. We tested the use of a calibrated GafChromic film (MD-55-2, Nuclear Associate, USA) for measuring the optical density. These measurements were achieved by irradiating the films with a dose of 0-112 Gy employing 6 MV photon. To verify the accuracy of the prescribed dose delivery to a target isocenter using a five arc beams (irradiated in 3 Gy per one beam) setup, calculated by the Linapel planning system the absolute dose and relative dose distribution using a GafChromic film were measured. All the irradiated films were digitized with a Lumiscan 75 laser digitizer and processed with the RIT113 film dosimetry system. Results: We verified the linearity of the Optical Density of a MD-55-2 GafChromic film, and measured the depth dose profile of the beam. The absolute dose delivered to the target was close to the prescribed dose of Linapel within an accuracy for the GafChromic film dosimetry (of $\pm$3$\%$), with a measurement uncertainty of $\pm$1 mm for the 50$\~$90$\%$ isodose lines. Conclusion: Our results have shown that the absolute dose and relative dose distribution curves obtained from a GafChromic film can provide information on the value for acceptance. To conclude the GafChromic flim is a convenient and useful dosimetry tool for linac based radiosurgery.

Development of a Thermoplastic Oral Compensator for Improving Dose Uniformity in Radiation Therapy for Head and Neck Cancer (두경부암 방사선치료 시 선량 균일도 향상을 위한 Thermoplastic 구강 보상체의 개발)

  • Choi, Joon-Yong;Won, Young-Jin;Park, Ji-Yeon;Kim, Jong-Won;Moon, Bong-Ki;Yoon, Hyong-Geun;Moon, Soo-Ho;Jeon, Jong-Byeong;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.269-278
    • /
    • 2012
  • Aquaplast Thermoplastic (AT) is a tissue-equivalent oral compensator that has been developed to improve dose uniformity at the common boundary and around the treated area during radiotherapy in patients with head and neck cancer. In order to assess the usefulness of AT, the degree of improvement in dose distribution and physical properties were compared to those of oral compensators made using paraffin, alginate, and putty, which are materials conventionally used in dental imprinting. To assess the physical properties, strength evaluations (compression and drop evaluations) and natural deformation evaluations (volume change over time) were performed; a Gafchromic EBT2 film and a glass dosimeter inserted into a developed phantom for dose verification were used to measure the common boundary dose and the beam profile to assess the dose delivery. When the natural deformation of the oral compensators was assessed over a two-month period, alginate exhibited a maximum of 80% change in volume from moisture evaporation, while the remaining tissue-equivalent properties, including those of AT, showed a change in volume that was less than 3%. In a free-fall test at a height of 1.5 m (repeated 5 times as a strength evaluation), paraffin was easily damaged by the impact, but AT exhibited no damage from the fall. In compressive strength testing, AT was not destroyed even at 8 times the force needed for paraffin. In dose verification using a glass dosimeter, the results showed that in a single test, the tissue-equivalent (about 80 Hounsfield Units [HU]) AT delivered about 4.9% lower surface dose in terms of delivery of an output coefficient (monitor unit), which was 4% lower than putty and exhibited a value of about 1,000 HU or higher during a dose delivery of the same formulation. In addition, when the incident direction of the beam was used as a reference, the uniformity of the dose, as assessed from the beam profile at the boundary after passing through the oral compensators, was 11.41, 3.98, and 4.30 for air, AT, and putty, respectively. The AT oral compensator had a higher strength and lower probability of material transformation than the oral compensators conventionally used as a tissue-equivalent material, and a uniform dose distribution was successfully formed at the boundary and surrounding area including the mouth. It was also possible to deliver a uniformly formulated dose and reduce the skin dose delivery.

Effect of High Dose ${\gamma}-irradiation$ on the Physicochemical Properties of Shell Eggs during Storage (고선량 감마선 조사가 신선란의 저장 중 이화학적 특성에 미치는 영향)

  • Moon, Sun-Ae;Song, Kyung-Bin
    • Applied Biological Chemistry
    • /
    • v.43 no.4
    • /
    • pp.260-265
    • /
    • 2000
  • To determine the quality change of the irradiated eggs during storage, fresh shell eggs were irradiated using $^{60}Co$ at 0, 1, 5, 10, 30 kGy and stored for 30 days. The york index, color, pH, viscosity, egg weight, and SDS-PAGE profile of the irradiated eggs were examined. During storage, york index values of the irradiated eggs and the control were decreased and the increase of dose decreased yolk index. However, the yolk index values were increased temporarily at 10 kGy and 30 kGy. The yolk color had a bright yellow with increases in dose level and there was no significant change during storage. The albumen viscosities were decreased with increases in dosage and were decreased during storage. Also, the albumen pH values of the irradiated eggs were higher than that of the control and were increased during storage. The weight losses of eggs were increased during storage and there were no significant changes by dose level. SDS-PAGE profile of the egg white proteins of the shell eggs showed the change in molecular weight distribution and had aggregation pattern as well as degradation. CD and fluorescence spectroscopy study showed changes in the secondary and tertiary structure of egg white proteins by ${\gamma}-irradiation$. Therefore, this study clearly indicates that irradiation dose of eggs should be appropriate to prevent the loss of egg qualities.

  • PDF

Search of Characteristic for Dose Distribution Presented by Multi­isocentric Stereotactic Radiosurgical Plan Using Linear Accelerator (선형 가속기를 이용한 정위적 방사선 수술시 병소내 선량분포의 특성조사)

  • 최경식;오승종;이형구;최보영;전흥재;서태석
    • Progress in Medical Physics
    • /
    • v.14 no.4
    • /
    • pp.225-233
    • /
    • 2003
  • The goal of a radiation treatment plan is to deliver a homogeneous dose to a target with minimal irradiation of the adjacent normal tissues. Dose uniformity is especially important for stereotactic radiosurgery using a linear accelerator. The dose uniformity and high dose delivery of a single spherical dose distribution exceed 70%. This also results with a similar stereotactic radiosurgical plan using a Gamma Knife. The dose distribution produced in a stereotactic radiosurgical plan using a Gamma Knife and Linear accelerator is spherical, and the application of the sphere packing arrangement in a real radiosurgical plan requires much time and skill. In this study, we found a characteristic of dose distribution with transformation of beam parameters that must be considered in a radiosurgical plan for effective radiosurgery. First, we assumed a cylinder type tumor model and a cube type tumor model. Secondly, the results of the tumor models were compared and analyzed with dose profiles and DVH_(Dose Volume Histogram) representative dose distribution. We found the optimal composition of beam parameters_(i.e. collimator size, number of isocenter, gap of isocenters etc.), which allowed the tumor models to be involved in the isodose curve at a high level. In conclusion, the characteristics found in this study are helpful for improving the effectiveness and speed of a radiosurgical plan for stereotactic radiosurgery.

  • PDF

A Physiologically Based Pharmacokinetic Model for Absorption and Distribution of Imatinib in Human Body

  • Chowdhury, Mohammad Mahfuz;Kim, Do-Hyun;Ahn, Jeong-Keun
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.11
    • /
    • pp.3967-3972
    • /
    • 2011
  • A whole body physiologically based pharmacokinetic (PBPK) model was applied to investigate absorption, distribution, and physiologic variations on pharmacokinetics of imatinib in human body. Previously published pharmacokinetic data of the drug after intravenous (i.v.) infusion and oral administration were simulated by the PBPK model. Oral dose absorption kinetics were analyzed by adopting a compartmental absorption and transit model in gut section. Tissue/plasma partition coefficients of drug after i.v. infusion were also used for oral administration. Sensitivity analysis of the PBPK model was carried out by taking parameters that were commonly subject to variation in human. Drug concentration in adipose tissue was found to be higher than those in other tissues, suggesting that adipose tissue plays a role as a storage tissue for the drug. Variations of metabolism in liver, body weight, and blood/plasma partition coefficient were found to be important factors affecting the plasma concentration profile of drug in human body.

Study on Structural properties of As Ion -Implanted Si (As이온이 주입된 Si의 구조적 특성 연구)

  • 믄영희;배인호;김말문;한병국;김창수;홍승수;신용현;정광화
    • Journal of the Korean Vacuum Society
    • /
    • v.5 no.3
    • /
    • pp.218-222
    • /
    • 1996
  • STrained layers and strain depth profile of high dose As ion implanted (100) si wafer annealed at various temperatures have been investigated by means of X-ray double crystal diffractometry (X-ray DCD). The results obtained by x-ray rocking curve analysis showed a defect layer at the original amorphous /crystalline interface of 1400$\AA$ depth. In addition arsenic ion concentrtion profiles and defect distributions in depth were obtained by the SIMS and TRIM -code simulation . the positive strain depth profile determined from the rocking curve analysis were only presented under 0.14 $\mu$m from the surface for samples ananelaed at $600^{\circ}C$. The results was shown that the thickness of amprphous layer is 0.14 $\mu$m indirectry, and it was good agreement with the TRIM -Code simulation. Additionally, it could be thought that the positive strain have been affected residual intersitial atoms under the amorphous/crystalline interface formed by ion implantation.

  • PDF

HPLC Determination and Pharmacokinetic Profile of Ethosuximide in Korean Subjects (에토석시미드의 HPLC 분석법 및 한국인에서의 약동학적 특징)

  • 배정우;김지홍;양상인;김현경;장춘곤;한혜원;박영서;손의동;이석용
    • YAKHAK HOEJI
    • /
    • v.47 no.6
    • /
    • pp.444-459
    • /
    • 2003
  • Ethosuximide is an oral anticonvulsantic agent used in the first choice anti-absence seizure drug. The purpose of this study was to assess the pharmacokinetic profile of the ethosuximide in healthy Korean volunteers and to develop the efficient assay method of ethosuximide in human plasma. The pharmacokinetics of ethosuximide administered orally was evaluated after a dose of 500 mg. Ethosuximide was assayed from plasma by a specific HPLC method reading absorbance at 195 nm. AUC was 1222$\pm$160 $\mu\textrm{g}$/$m\ell$$.$hr, $C_{max}$ 14.2l$\pm$1.74 $\mu\textrm{g}$/$m\ell$, $T_{max}$ 1.06$\pm$0.62 hr and half-life 77.83$\pm$12.46 hr. The half-life in Korean was longer than, in Caucasian (53∼56 hr).).).

Sheet Resistance of Ion Implanted Si(100) at Various Doses, Energies and Beam Currents (Si(100)에 이온 주입 시 에너지, 조사량과 빔 전류에 따른 면저항의 변화)

  • Kim, Hyung-In;Jeong, Young-Wan;Lee, Myeung-Hee;Kang, Suk-Tai
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.2
    • /
    • pp.100-105
    • /
    • 2011
  • Simulations were performed using Crystal TRIM software under the same conditions used by previous researchers in order to clarify the mechanism that determines sheet resistance various doses, energies and beam currents. The results showed that the peak of the depth profile (Rp) in the same sample gradually shifts inward and damage increases near the surface as the energy increases for $As^+$ equal dose of $1{\times}10^{15}/cm^2$ implanted into Si(100) energies of 5, 10, and 15 keV. From a theoretical calculation of B+ ion implantation processes at energy of 20 keV using parameters that correspond to 1 mA and 7 mA beam currents with the same dose of $5{\times}10^{15}/cm^2$, it was found that the higher beam currents resulted in more damage near the surface (<100 nm). Likewise, In the simulations employing sets of doses ($1{\times}10^{15}$, $3{\times}10^{15}/cm^2$) and beam currents (0.8 mA, 8 mA), more damage was produced at larger doses and higher current. Thus, sheet resistance at the surface was reduced by the intensified damage from increases in beam energy, dose and beam currents.