• Title/Summary/Keyword: dose intensity

검색결과 603건 처리시간 0.033초

Discrepancies between Calculated and Delivered Dose Distributions of Respiratory Gated IMRT Fields according to the Target Motion Ranges for Lung and Liver Cancer Patients (호흡연동방사선치료시 폐암과 간암환자의 병소 움직임 크기에 따른 선량분포 차이 분석)

  • Kim, Youngkuk;Lim, Sangwook;Choi, Ji Hoon;Ma, Sun Young;Jeung, Tae Sig;Ro, Tae Ik
    • Progress in Medical Physics
    • /
    • 제25권4호
    • /
    • pp.242-247
    • /
    • 2014
  • To see the discrepancies between the calculated and the delivered dose distribution of IMRT fields for respiratory-induced moving target according to the motion ranges. Four IMRT plans in which there are five fields, for lung and liver patients were selected. The gantry angles were set to $0^{\circ}$ for every field and recalculated using TPS (Eclipse Ver 8.1, Varian Medical Systems, Inc., USA). The ion-chamber array detector (MatriXX, IBA Dosimetry, Germany) was placed on the respiratory simulating platform and made it to move with ranges of 1, 2, and 3 cm, respectively. The IMRT fields were delivered to the detector with 30~70% gating windows. The comparison was performed by gamma index with tolerance of 3 mm and 3%. The average pass rate was 98.63% when there's no motion. When 1.0, 2.0, 3.0 cm motion ranges were simulated, the average pass rate were 98.59%, 97.82%, and 95.84%, respectively. Therefore, ITV margin should be increased or gating windows should be decreased for targets with large motion ranges.

Clinical outcome of proton therapy for patients with chordomas

  • Youn, Sang Hee;Cho, Kwan Ho;Kim, Joo-Young;Ha, Boram;Lim, Young Kyung;Jeong, Jong Hwi;Lee, Sang Hyun;Yoo, Heon;Gwak, Ho-Shin;Shin, Sang Hoon;Hong, Eun Kyung;Kim, Han Kyu;Hong, Je Beom
    • Radiation Oncology Journal
    • /
    • 제36권3호
    • /
    • pp.182-191
    • /
    • 2018
  • Purpose: To investigate the clinical outcome of proton therapy (PT) in patients with chordoma. Materials and Methods: Fifty-eight patients with chordoma treated with PT between June 2007 and December 2015 at the National Cancer Center, Korea, were retrospectively analyzed. The median total dose was 69.6 cobalt gray equivalent (CGE; range, 64.8 to 79.2 CGE). Local progression-free survival (LPFS), distant metastasis-free survival (DMFS), overall survival (OS), and disease-specific survival (DSS) rates were calculated by the Kaplan-Meier method. Results: With the median follow-up of 42.8 months (range, 4 to 174 months), the 5-year LPFS, DMFS, OS, and DSS rates were 87.9%, 86.7%, 88.3%, and 92.9%, respectively. The tumor location was associated with the patterns of failure: the LPFS rates were lower for cervical tumors (57.1%) than for non-cervical tumors (93.1%) (p = 0.02), and the DMFS rates were lower for sacral tumors (53.5%) than for non-sacral tumors (100%) (p = 0.001). The total dose was associated with both the LPFS rate and DMFS rate. The initial tumor size was associated with the DMFS rate, but was not associated with the LPFS rate. Three patients had grade 3 late toxicity with none ≥grade 4. Conclusion: PT is an effective and safe treatment in patients with chordomas. The tumor location was associated with the patterns of failure: local failure was common in cervical tumors, and distant failure was common in sacral tumors. Further refinement of PT, such as the utilization of intensity modulated PT for cervical tumors, is warranted to improve the outcome.

Performance Evaluation of Aprons according to Lead Equivalent and Form Types (방사선 방어용 앞치마의 납당량, 형태에 따른 성능 평가)

  • Kim, Ki-Won;Choi, Sung-Hyun;Kim, Ki-Yeol;Lee, Ik-Pyo;Hwang, Sun-Gwang;Dong, Kyung-Rae
    • Journal of Radiation Industry
    • /
    • 제10권4호
    • /
    • pp.219-225
    • /
    • 2016
  • The apron is one of the essential protectors to reduce the exposure dose of radiological technologists. This study is to provide a guideline for purchasing the aprons with excellent performance and to help reducing the exposure dose by measuring the shielding ration and uniformity of aprons according to lead equivalent and form types. The shielding ratio of aprons were measured by using radiation generator and dosimeter. Exposure conditions were 81 kVp, 25 mAs, source to image receptor distance (SID) 100 cm and field of view (FOV) $17^{{\prime}{\prime}}{\times}17^{{\prime}{\prime}}$. Exposure areas for front type and around type aprons were divided into 9 areas and for 2 pieces type aprons were divided into 3 areas of top and 4 areas of skirt. The uniformity of aprons were measured by using fluoroscopy and Image J. The 4 regions of interest (ROI) were set into acquired images and measured uniformity by measuring the standard deviation of pixel intensity in ROIs. In continuous shielding ration measurement of aprons according to exposure area, there was not statistical significance (P>0.05). In ANOVA test of aprons, there was statistical significance (P<0.01). In the results of sheilding ratio, although the aprons had equal lead equivalent, there were difference in shielding ratio from 83.59% to 98.15%. In the results of uniformity, the front type aprons with equal lead equivalent indicated the similar uniformity. However, the around type and 2 pieces type apron with equal lead equivalent indicated the different uniformity each other, from 1.8 to 22.2. If the performance evaluation in this study were conducted regularly before and after purchase the aprons, the exposure does to patients and radiological technologists could be reduced.

Patient Specific Quality Assurance of IMRT: Quantitative Approach Using Film Dosimetry and Optimization (강도변조방사선치료의 환자별 정도관리: 필름 선량계 및 최적화법을 이용한 정량적 접근)

  • Shin Kyung Hwan;Park Sung-Yong;Park Dong Hyun;Shin Dongho;Park Dahl;Kim Tae Hyun;Pyo Hongryull;Kim Joo-Young;Kim Dae Yong;Cho Kwan Ho;Huh Sun Nyung;Kim Il Han;Park Charn Il
    • Radiation Oncology Journal
    • /
    • 제23권3호
    • /
    • pp.176-185
    • /
    • 2005
  • Purpose: Film dosimetry as a part of patient specific intensity modulated radiation therapy quality assurance (IMRT QA) was peformed to develop a new optimization method of film isocenter offset and to then suggest new quantitative criteria for film dosimetry. Materials and Methods: Film dosimetry was peformed on 14 IMRT patients with head and neck cancers. An optimization method for obtaining the local minimum was developed to adjust for the error in the film isocenter offset, which is the largest part of the systemic errors. Results: The adjust value of the film isocenter offset under optimization was 1 mm in 12 patients, while only two patients showed 2 mm translation. The means of absolute average dose difference before and after optimization were 2.36 and $1.56\%$, respectively, and the mean ratios over a $5\%$ tolerance were 9.67 and $2.88\%$. After optimization, the differences in the dose decreased dramatically. A low dose range cutoff (L-Cutoff) has been suggested for clinical application. New quantitative criteria of a ratio of over a $5\%$, but less than $10\%$ tolerance, and for an absolute average dose difference less than $3\%$ have been suggested for the verification of film dosimetry. Conclusion: The new optimization method was effective in adjusting for the film dosimetry error, and the newly quantitative criteria suggested in this research are believed to be sufficiently accurate and clinically useful.

Evaluation between 3.0 T vs 1.5 T MRI in Detection of Brain Metastasis using Double Dose Gd-DTPA (뇌전이 종양의 발견에 있어서 Doble dose Gd-DTPA를 이용한 3 T MRI와 1.5 T MRI간의 비교연구)

  • Chung, Woo-Suk;Kim, Hyung-Jung;Ahn, Chul-Min;Lee, Jae-Hoon;Hur, Jin;Cho, Eung-Hyuck;Chung, Tae-Sub
    • Investigative Magnetic Resonance Imaging
    • /
    • 제9권2호
    • /
    • pp.101-108
    • /
    • 2005
  • Purpose : Early detection of small brain metastases is important. The purpose of this study was to compare the detectability of brain metastases according to the size between 1.5 T and 3.0 T MRI. Materials and Methods : We reviewed 162 patients with primary lung cancer who were examined for TNM staging. After administration of double dose of Gd-DTPA, MR imaging was performed with SPGR by 3.0 T MRI and then with T1 SE sequence by 1.5 T MRI. In each patient, three readers performed qualitative assessment. Sensitivity, positive predictive value, and diagnostic accuracy were calculated in 3.0 T and 1.5 T MRI according to size. Using the signal intensity (SI) measurements between the metastatic nodules and adjacent tissue, nodule-to-adjacent tissue SI ratio was calculated. Results : Thirty-one of 162 patients had apparent metastatic nodules in the brain at either 1.5 T or 3.0 T MR imaging. 143 nodules were detected in 3.0 T MRI, whereas 137 nodules were detected at 1.5 T MRI. Six nodules, only detected in 3.0 T MRI, were smaller than 3.0 mm in dimension. Sensitivity, positive predictive value, and diagnostic accuracy in 3.0 T MRI were 100 %, 100 %, and 100 % respectively, and in 1.5 T MRI were 95.8%, 88.3%, and 85.1% respectively. SI ratio was significantly higher in the 3.0 T MRI than 1.5 T MRI (p=0.025). Conclusion : True positive rate of 3.0 T MRI with Gd-DTPA was superior to 1.5 T MRI with Gd-DTPA in detection of metastatic nodules smaller than 3.0 mm.

  • PDF

Characteristics of the Maximum Glow Intensity According to the Thermoluminescent Phosphors used in the Absorbed Dose Measurement of the Radiation Therapy (방사선치료 선량 측정에 사용되는 열형광체에 따른 최대 형광 강도 특성)

  • Kang, Suman;Im, Inchul;Park, Cheolwoo;Lee, Mihyeon;Lee, Jaeseung
    • Journal of the Korean Society of Radiology
    • /
    • 제8권4호
    • /
    • pp.181-187
    • /
    • 2014
  • The purpose of this study were to analyze the characteristic of the glow curves in order to the glow temperature of the thermoluminescent dosimeters (TLDs) for the absorbed dose measurement of the radiation therapy. In this study, we was used the TLDs of the LiF:Mg${\cdot}$Ti, LiF:Mg${\cdot}$Cu${\cdot}$P, $CaF_2$:Dy, $CaF_2$:Mn (Thermo Fisher Scientific Inc., USA). The source-to-solid dry phantom (RW3 slab, IBA Dosmetry, Germany) surface distance was set at 100 cm, and the exposure dose of 100 MU (monitor unit) was used 6- and 15-MV X-rays, and 6- and 12-MeV electron beams in the reference depth, respectively. After the radiations exposure, we were to analyze the glow curves by using the TL reader (Hashaw 3500, Thermo Fisher Scientific Inc., USA) at the fixed heating rate of $15^{\circ}C/sec$ from $50^{\circ}C$ to $260^{\circ}C$. The glow peaks, the trapping level in the captured electrons and holes combined with the emitted light, were discovered the two or three peak. When the definite increasing the temperature of the TLDs, the maximum glow peak representing the glow temperature was follow as; $LiF:Mg{\cdot}Ti$: $185.5{\pm}1.3^{\circ}C$, $LiF:Mg{\cdot}Ti$: $135.0{\pm}5.1^{\circ}C$, $CaF_2$:Dy: $144.0{\pm}1.6^{\circ}C$, $CaF_2$:Mn: $294.3{\pm}3.8^{\circ}C$, respectively. Because the glow emission probability of the captured electrons depend on the heating temperature after the exposure radiation, TLDs by applying the fixed heating rate, the accuracy of measurement will be able to improve within the absorbed dose measurement of the radiation therapy.

Long Term Outcomes of Gamma Knife Radiosurgery for Typical Trigeminal Neuralgia-Minimum 5-Year Follow-Up

  • Lee, Jong-Kwon;Choi, Hyuk-Jai;Ko, Hak-Cheol;Choi, Seok-Keun;Lim, Young-Jin
    • Journal of Korean Neurosurgical Society
    • /
    • 제51권5호
    • /
    • pp.276-280
    • /
    • 2012
  • Objective : Gamma knife radiosurgery (GKRS) is the least invasive surgical option for patients with trigeminal neuralgia (TN). However, the indications and long term outcomes of GKRS are still controversial. Additionally, a series with uniform long-term follow-up data for all patients has been lacking. In the present study, the authors analyzed long-term outcomes in a series of patients with TN who underwent a single GKRS treatment followed by a minimum follow-up of 60 months. Methods : From 1994 to 2009, 40 consecutive patients with typical, intractable TN received GKRS. Among these, 22 patients were followed for >60 months. The mean maximum radiation dose was 77.1 Gy (65.2-83.6 Gy), and the 4 mm collimator was used to target the radiation to the root entry zone. Results : The mean age was 61.5 years (25-84 years). The mean follow-up period was 92.2 months (60-144 months). According to the pain intensity scale in the last follow-up, 6 cases were grades I-II (pain-free with or without medication; 27.3%) and 7 cases were grade IV-V (<50% pain relief with medication or no pain relief; 31.8%). There was 1 case (facial dysesthesia) with post-operative complications (4.54%). Conclusion : The long-term results of GKRS for TN are not as satisfactory as those of microvascular decompression and other conventional modalities, but GKRS is a safe, effective and minimally invasive technique which might be considered a first-line therapy for a limited group of patients for whom a more invasive kind of treatment is unsuitable.

Eryngium foetidum Suppresses Inflammatory Mediators Produced by Macrophages

  • Mekhora, Chusana;Muangnoi, Channarong;Chingsuwanrote, Pimjai;Dawilai, Suwitcha;Svasti, Saovaros;Chasri, Kaimuk;Tuntipopipat, Siriporn
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권2호
    • /
    • pp.653-664
    • /
    • 2012
  • Objective: This study assessed anti-inflammatory and antioxidant activities of $E.$ $foetidum$ leaf extract on LPS-activated murine macrophages. Methods: RAW264.7 cells were pretreated with or without $E.$ $foetidum$ extract for 1 h prior to incubation with LPS for 24 h. Anti-inflammatory activity was evaluated with reference to iNOS, COX-2, TNF-${\alpha}$ and IL-6 gene expression. In addition, NO and intracellular ROS generation were determined by Griess method and fluorescence intensity and activation of MAPKs and $I{\kappa}B$ by Western blotting. Results: Prior treatment with $E.$ $foetidum$ leaf extract inhibited elevation of IL-6, TNF-${\alpha}$, iNOS and COX-2, together with their cognate mRNAs in a dose-dependent manner. NO and intracellular ROS contents were similarly reduced. These effects were due to inhibition of LPS-induced phosphorylation of JNK and p38 as well as $I{\kappa}B$. $E.$ $foetidum$ ethanol extract were shown to contain lutein, ${\beta}$-carotene, chlorogenic acid, kaempferol and caffeic acid, compounds known to exert these bioactive properties. Conclusions: $E.$ $foetidum$ leaf extract possesses suppressive effects against pro-inflammatory mediators. Thus, $E.$ $foetidum$ has a high potential to be used as a food supplement to reduce risk of cancer associated with inflammation.

Effects of different UV-8 levels on the growth, photosynthesis and pigments in cucumber(Cucumis sativus L.) (UV-B 강도 변화가 오이(Cucumis sativus L.)의 생장, 광합성 및 색소에 미치는 영향)

  • Kim, Hak-Yoon;Lee, In-Jung;Shin, Dong-Hyun;Kim, Kil-Ung
    • Journal of Life Science
    • /
    • 제8권3호
    • /
    • pp.272-278
    • /
    • 1998
  • To investigate the effects of different UV-B levels on plant growth, cucumber plants were subjected to three levels of biologically effective ultraviolet-B(UV--$B^{BE}$ radiation [daily dose : 0.03(No UV-B), 6.40(Low UV-B) and 11.30 (High UV-B) kJ $m^{-2}$, UV--$B^{BE}$] in the growth chambers for 3 weeks during the early growth period. High and low levels of UV-B irradiation drastically decreased both dry weight and leaf area, but increased specific leaf weight of cucumber. Plants subjected to UV-B resulted in 30% and 20% reduction of photosynthesis rate by high and low UV-B, respectively. However, respiration rate was not affected by the UV-B. With increasing UV-B intensity, total chlorophyll contents were decreased linearly, while the contents of flavonoid were increased linearly. These results suggest that the present levels of UV-B may affect the growth of cucumber plant compared with a UV-B-free condition. It is likely that the growth of cucumber will be affected by enhanced UV-B due to ozone depletion in the near future.

  • PDF

Stimulatory Effects of Ginsenosides on Bovine Brain Glutamate Decarboxylase

  • Choi, Soo-Young;Bahn, Jae-Hoon;Jeon, Seong-Gyu;Chung, Young-Mee;Hong, Joung-Woo;Ahn, Jee-Yin;Hwang, Eun-Joo;Cho, Sung-Woo;Park, Jin-Kyu;Baek, Nam-In
    • BMB Reports
    • /
    • 제31권3호
    • /
    • pp.233-239
    • /
    • 1998
  • A GABA synthesizing enzyme, glutamate decarboxylase, has been purified from bovine brain by several chromatographic procedures. The preparation appeared homogeneous on SDS-PAGE. The enzyme is a homodimeric protein with a molecular mass of 120 kDa. The activation of glutamate decarboxylase by ginesenosides from Panax ginseng C.A. Meyer has been studied. Preincubation of the enzyme with total ginsenoside, $Rb_2$ and Rc ginsenosides, increased glutamate decarboxylase activities in a dose-dependent manner. There was a reproducible decrease in $K_m$, in addition to a increase in $V_{max}$, in response to increasing concentrations of the Rc ginsenoside fraction. Upon addition of the ginsenoside to the enzyme, a decrease in flurorescence intensity was discernible, together with an increase in emission anisotropy. Judging from the anisotropy values, the ginsenoside is rapidly trapped by the protein matrix. Total ginsenoside was administered to rats and the rat brains were removed for the measurement of the changes of GABA shunt regulating enzyme activities. Among the GABA shunt regulating enzymes, only the glutamate decarboxylase activities were increased after ginsenoside treatment. Therefore, it is suggested that the ginsenosides may elevate the GABA level in brain by activation of glutamate decarboxylase and the enzymatic activation might be due to the conformational change induced by binding of ginsenoside to the enzyme.

  • PDF