• Title/Summary/Keyword: dose evaluation technique

Search Result 130, Processing Time 0.026 seconds

Development of Reference Korean Organ and Effective Dose Calculation Online System (웹 기반 표준한국인 장기 흡수선량 및 유효선량 평가 시스템 개발)

  • Park, Sooyeun;Yeom, Yeon Soo;Kim, Jae Hyeon;Lee, Hyun Su;Han, Min Cheol;Jeong, Jong Hwi;Kim, Chan Hyeong
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.30-37
    • /
    • 2014
  • Recently High-Definition Reference Korean-Man (HDRK-Man) and High-Definition Reference Korean-Woman (HDRK-Woman) were constructed in Korea. The HDRK phantoms were designed to represent respectively reference Korean male and female to calculate effective doses for Korean by performing Monte Carlo dose calculation. However, the Monte Carlo dose calculation requires detailed knowledge on computational human phantoms and Monte Carlo simulation technique which regular researchers in radiation protection dosimetry and practicing health physicists do not have. Recently the UFPE (Federal University of Pernambuco) research group has developed, and opened to public, an online Monte Carlo dose calculation system called CALDOSE_X(www.caldose.org). By using the CALDOSE_X, one can easily perform Monte Carlo dose calculations. However, the CALDOSE_X used caucasian phantoms to calculate organ doses or effective doses which are limited for Korean. The present study developed an online reference Korean dose calculation system which can be used to calculate effective doses for Korean.

The evaluation of dose of TSEI with TLD and diode dector of the uterine cervix cancer (열형광선량계와 반도체검출기를 이용한 전신피부전자선조사의 선량평가)

  • Je Young Wan;Na Keyung Su;Yoon IL Kyu;Park Heung Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.57-71
    • /
    • 2005
  • Purpose : To evaluate radiation dose and accuracy with TLD and diode detector when treat total skin with electron beam. Materials and Methods : Using Stanford Technique, we treated patient with Mycosis Fungoides. 6 MeV electron beam of LINAC was used and the SSD was 300 cm. Also, acrylic speller(0.8 cm) was used. The patient position was 6 types and the gantry angle was 64, 90 and $116^{\circ}$. The patient's skin dose and the output were detected 5 to 6 times with TLD and diode. Result : The deviations of dose detected with TLD from tumor dose were CA $+\;6\%$, thigh $+\;8\%$, umbilicus $+\;4\%$, calf $-\;8\%$, vertex $-\;74.4\%$, deep axillae $-\;10.2\%$, anus and testis $-\;87\%$, sole $-\;86\%$ and nails shielded with 4mm lead $+4\%$. The deviations of dose detected with diode were $-4.5\%{\sim}+5\%$ at the patient center and $-1.1\%{\sim}+1\%$ at the speller. Conclusion : The deviation of total skin dose was $+\;8\%{\sim}-\;8\%$ and that deviation was within the acceptable range(${\pm}\;10\%$). The boost dose was irradiated for the low dose areas(vertex, anus, sole). The electron beam output detected at the sootier was stable. It is thought that the deviation of dose at patient center detected with diode was induced by detection point and patient position.

  • PDF

Evaluation of the Low Tube Voltage in the Computed Tomography Scan Technique using a Low Concentration Contrast Agent (저농도 조영제를 사용한 CT검사에서 저관전압 기법에 따른 유용성 평가)

  • Jung, Kang-Kyo;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.71-79
    • /
    • 2016
  • The purpose of this study is computed tomography contrast agent at low concentrations and low tube voltage technique to evaluate the usefulness on the phantom image. By varying the degree of mixture by the contrast medium concentration it was inserted in phantom. It was taken by changing the tube voltage and tube current step by step, and to evaluate the dose and the CT value obtained from the phantom image. As a result, low-contrast, low tube voltage(300 mgI/ml, 100 kV) was reduced by an average 21%(CTDIvol; computed tomography dose indexvol) more standard condition(350 mgI/ml, 120 kV). SNR was increased at all depths of the phantom, respectively 1:10 and 1:20(by diluting a contrast agent and normal saline) 12.2(26%) 6.2(17%). CNR was increased at all depths of the phantom, respectively 1:10 and 1:20(by diluting a contrast agent and normal saline) 11.5(32%), 6.3(26%). Research work on the CT scan is necessary in a variety of studies on the low contrast concentration and low tube voltage techniques for dose reduction and reducing of side effects the contrast agent.

Evaluation of ROC Curve in High Kilovoltage Technique Using Simulated Nodules on Chest (고관전압 흉부촬영의 가상결절을 이용한 ROC평가)

  • Ahn, Jin-Shin;Chang, Myung-Mi;Chung, Kyung-Mo;Cheung, Hwan;Lim, Jung-Ki;Kim, Jong-Hyo
    • Journal of radiological science and technology
    • /
    • v.15 no.2
    • /
    • pp.25-30
    • /
    • 1992
  • With transmitted dose through chest which has the problem of wide variations in absorption, simple film/screen combination method makes it diffucult to image lung field, mediastinum and retrocardiac areas. In order to overcome this, it is very common to use the high kilovoltage technique in diminishing the differences between high and low contrast. We have been adopting this method at department of diagnostic radiology, Seoul National University Hospital. To compare the image of it with that of low kilovoltage technique, we did radiographic tests using beans on the skin. We marked off into three anatomical categories such as lungs, mediastinum and near diaphragm, then attached a bean on a marked area at random. In order to compare with high and low, we took a radiography of high($120{\sim}140\;kVp$) and low($70{\sim}90\;kVp$) kilovoltage tehchniques, respectively at the same time. We have done experiments 320 cases. We evaluated the results of test in response to sensitivity(true positive) and specificity(true negative). In evaluating, we gave them points from 1 to 5 according to true or false. With given points by a radiologist having much experiences, we could acquire the percentage of sensitivity and specificity. The percentage made us to get the schematic table of ROC curve of those two methods. Consequently, high kilovoltage technique appeared 18% better than low kilovoltage technique for detecting beans with our apparatus.

  • PDF

Dynamic Computed Tomography based on Spatio-temporal Analysis in Acute Stroke: Preliminary Study (급성 뇌졸중 환자의 시공간 분석 기법을 이용한 동적 전산화 단층 검사: 예비 연구)

  • Park, Ha-Young;Pyeon, Do-Yeong;Kim, Da-Hye;Jung, Young-jin
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.543-547
    • /
    • 2016
  • Acute stroke is a one of common disease that require fast diagnosis and treatment to save patients life. however, the acute stroke may cause lifelong disability due to brain damage with no prompt surgical procedure. In order to diagnose the Stroke, brain perfusion CT examination and possible rapid implementation of 3D angiography has been widely used. However, a low-dose technique should be applied for the examination since a lot of radiation exposure to the patient may cause secondary damage for the patients. Therefore, the degradation of the measured CT images may interferes with a clinical check in that blood vessel shapes on the CT image are significantly affected by gaussian noise. In this study, we employed the spatio-temporal technique to analyze dynamic (brain perfusion) CT data to improve an image quality for successful clinical diagnosis. As a results, proposed technique could remove gaussian noise successfully, demonstrated a possibility of new image segmentation technique for CT angiography. Qualitative evaluation was conducted by skilled radiological technologists, indicated significant quality improvement of dynamic CT images. the proposed technique will be useful tools as a clinical application for brain perfusion CT examination.

Evaluation of DNA Damage Using Microwave Dielectric Absorption Spectroscopy

  • Hirayama, Makoto;Matuo, Youichirou;Sunagawa, Takeyoshi;Izumi, Yoshinobu
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.339-343
    • /
    • 2016
  • Background: Evaluation of deoxyribonucleic acid (DNA)-strand break is important to elucidate the biological effect of ionizing radiations. The conventional methods for DNA-strand break evaluation have been achieved by Agarose gel electrophoresis and others using an electrical property of DNAs. Such kinds of DNA-strand break evaluation systems can estimate DNA-strand break, according to a molecular weight of DNAs. However, the conventional method needs pretreatment of the sample and a relatively long period for analysis. They do not have enough sensitivity to detect the strand break products in the low-dose region. Materials and Methods: The sample is water, methanol and plasmid DNA solution. The plasmid DNA pUC118 was multiplied by using Escherichia coli JM109 competent cells. The resonance frequency and Q-value were measured by means of microwave dielectric absorption spectroscopy. When a sample is located at a center of the electric field, resonance curve of the frequency that existed as a standing wave is disturbed. As a result, the perturbation effect to perform a resonance with different frequency is adopted. Results and Discussion: The resonance frequency shifted to higher frequency with an increase in a concentration of methanol as the model of the biological material, and the Q-value decreased. The absorption peak in microwave power spectrum of the double-strand break plasmid DNA shifted from the non-damaged plasmid DNA. Moreover, the sharpness of absorption peak changed resulting in change in Q-value. We confirmed that a resonance frequency shifted to higher frequency with an increase in concentration of the plasmid DNA. Conclusion: We developed a new technique for an evaluation of DNA damage. In this paper, we report the evaluation method of DNA damage using microwave dielectric absorption spectroscopy.

Preliminary Report of Gamma Knife Radiosurgery for the Movement Disorders (운동성 장애에 대한 감마나이프 시술의 초기경험)

  • Hong, Joon Ki;Kim, Moo Seong;Lee, Sun Il;Jung, Yong Tae;Kim, Soo Chun;Sim, Jae Hong
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.8
    • /
    • pp.1024-1029
    • /
    • 2000
  • Objectives : With recent improvements in neuroimaging and the development of third and fourth-generation radiosurgical dose-planning soft ware, came a renewed interest in using radiosurgery for the treatment of movement disorders. Radiosurgery involves no opening of the cranium and no incisions, eliminating both the risk of hemorrhage from passing an electrode to the depths of meningitis from operative infection. It is for these reasons stereotactic radiosurgical treatment of movement disorders has value in a small subgroup of patients. The authors report four cases of Parkinson's disease and one case of dystonia that were treated by Gamma knife. Methods : Radiosurgical nucleus ventralis intermedius thalamotomy using the gamma knife unit was performed to make lesion in two Parkinson's disease patients. A radiation dose of 120Gy was delivered to nucleus using a single 4-mm collimator plug pattern following classic anatomical landmarks. Patients were followed for a median of 10.5 months(range 9-12 months). An independent neurological evaluation of tremor, based on the change in the United Parkinson's Disease Rating Scale tremor score(UPDRS), was correlated with a subjective evaluation. Gamma knife ventrolateral(V.O.P) thalamotomy was performed in one case of dystonia. A central dose of 150Gy was delivered and the patient was followed for 18 months. Gamma knife globus pallidus interna pallidotomy was performed in two Parkinson's disease patients. A radiation dose of 130Gy(range 120-140Gy) was delivered. Patients were followed for a median of 13 months(range 9-14 months). Result : Ventrolateral thalamotomy in dystonia produced regained left hand usage in order to be able to use the telephone. Ventralis intermedius thalamotomy produced an excellent improvement of the tremor in one case, mild improvement of the tremor in the other case of Parkinson's disease. A globus pallidus internalis(GPi) pallidotomy produced improvement of rigidity and dyskinesia : one other showed no change. There were no neurological complications. Conclusion : Gamma Knife thalamotomy considered a safe and effective technique for the treatment of tremor in Parkinson's disease. Although the results from Longer follow-up is not available yet, the short-term results seem to be encouraging.

  • PDF

Development of DAP(Dose Area Product) for Radiation Evaluation of Medical and Industrial X-ray generator (의료 및 산업용 X-선 발생장치의 선량평가를 위한 면적선량계(DAP) 개발)

  • Kwak, Dong-Hoon;Lee, Sang-Heon;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.22 no.2
    • /
    • pp.495-498
    • /
    • 2018
  • In this paper, we propose an DAP system for dose evaluation of medical and industrial X-ray generator. Based on the DAP measurement technique using the Ion-Chamber, the proposed system can clearly measure the exposure radiation dose generated by the diagnostic X-ray apparatus. The hardware part of the DAP measures the amount of charge in the air that is captured by an X-ray. The high-speed processing algorithm part for cumulative radiation dose measurement through microcurrent measures the amount of charge captured by X-ray at a low implementation cost (power) with no input loss. The wired/wireless transmission/reception protocol part synchronized with the operation of the X-ray generator improves communication speed. The PC-based control program part for interlocking and aging measures the amount of X-ray generated in real time and enables measurement graphs and numerical value monitoring through PC GUI. As a result of evaluating the performance of the proposed system in an accredited testing laboratory, the measured values using DAP increased linearly in each energy band (30, 60, 100, 150 kV). In addition, since the standard deviation of the measured value at the point of 4 division was ${\pm}1.25%$, it was confirmed that the DAP showed uniform measurements regardless of location. It was confirmed that the normal operation was not less than ${\pm}4.2%$ of the international standard.

Development of a Guided Wave Technique for the Inspection of a Feeder Pipe in a Pressurized Heavy Water Reactor

  • Cheong, Yong-Moo;Lee, Dong-Hoon;Kim, Sang-Soo;Jung, Hyun-Kyu
    • Corrosion Science and Technology
    • /
    • v.4 no.3
    • /
    • pp.108-113
    • /
    • 2005
  • One of the recent safety issues in the pressurized heavy water reactor (PHWR) is the cracking of the feeder pipe. Because of the limited accessibility to the cracked region and a high dose of radiation exposure, it is difficult to inspect all the pipes with the conventional ultrasonic method. In order to solve this problem, a long-range guided wave technique has been developed. A computer program to calculate the dispersion curves in the pipe was developed and the dispersion curves for the feeder pipes in PHWR plants were determined. Several longitudinal and/or flexural modes were selected from the review of the dispersion curves and an actual experiment has been carried out with the specific alignment of the piezoelectric ultrasonic transducers. They were confirmed as L(0,1)) and/or flexural modes(F(m,2)) by the short time Fourier transformation(STFT) and were sensitive to the circumferential cracks, but not to the axial cracks in the pipe. An electromagnetic acoustic transducers(EMAT) was designed and fabricated for the generation and reception of the torsional guided wave. The axial cracks were detected by a torsional mode(T(0,1)) generated by the EMAT.

Evaluation of an Education Program for Patients with Asthma who use Inhalers (천식 환자를 위한 흡입기 교육 프로그램의 효과)

  • Lee, Jong-Kyung;Yang, Young-Hee
    • Journal of Korean Academy of Nursing
    • /
    • v.40 no.2
    • /
    • pp.202-212
    • /
    • 2010
  • Purpose: This study was done to evaluate the effectiveness of an education program for patients with asthma who use inhalers. Methods: The research design for this study was a non-equivalent control group quasi-experimental study. Participants in this study were 36 patients for the control group, and 43 patients for the experimental group. The experimental group participated in the education program. The control group received the usual care. Data were collected before and 1 month and 2 months after the program finished and were analyzed using the SPSS 12.0 program. Results: The experimental group had significantly higher scores of knowledge of inhalers, and inhalation technique compared to the control group. However, no significant differences were found between two groups for PEFR, asthma instability, and satisfaction with inhalers. Conclusion: According to the results, the education program was effective in improving knowledge of inhalers, and inhalation technique. Therefore, it is recommended that this education program be used in clinical practice as an effective nursing intervention for patients with asthma on inhalers.