• 제목/요약/키워드: doppler ultrasound

검색결과 142건 처리시간 0.024초

Hyaluronic Acid Filler Injection Guided by Doppler Ultrasound

  • Won Lee
    • Archives of Plastic Surgery
    • /
    • 제50권4호
    • /
    • pp.348-353
    • /
    • 2023
  • Doppler ultrasound can be used to detect almost all arteries of the face before injecting the hyaluronic acid (HA) filler. The relatively more dangerous sites of filler injection are the glabellar wrinkle, forehead, temple, nose, and nasolabial fold area, and it is recommended to map the vasculature of these areas by Doppler ultrasound before performing filler injection. The Doppler ultrasound detection method is included as a video. Internal carotid arterial branches, the supratrochlear, supraorbital, and dorsal nasal arteries, and external carotid arterial branches, the superficial temporal and facial arteries, are very important arteries when injecting HA filler; thus, Doppler ultrasound detection is recommended.

근골격계 초음파의 기판 조절 입문: B Mode와 Doppler (Introduction to Knobology Focusing on B Mode and Doppler Setting in Musculoskeletal Ultrasound)

  • 민경훈
    • Clinical Pain
    • /
    • 제20권1호
    • /
    • pp.7-14
    • /
    • 2021
  • Musculoskeletal ultrasound has evolved as the essential tool to diagnose and guide intervention procedures in people with neuromusculoskeletal conditions. Image optimization and understanding device operations are core components for ultrasound guided intervention procedure training. All ultrasound machines share the common operative features and there are various buttons for the features in the device control panel. Ultrasound "knobology" refers to the thorough understanding of imaging optimization. This review addressed basic information for the transducers, depth setting, gain and focus control, different modes focusing on brightness and doppler modes.

도플러 초음파 감시하 알렌 검사로 진단한 상지 볼크만 구축 환자의 척골 동맥 협착 - 1례 보고 - (Doppler Ultrasound guided modified Allen's Test in Volkmann's Ischemic Contracture Patient with Ulnar Artery Constriction)

  • 김철홍;하동호;김보건;유성곤
    • 대한정형외과 초음파학회지
    • /
    • 제4권2호
    • /
    • pp.84-87
    • /
    • 2011
  • 볼크만 구축 환자의 술 전 준비 단계에서 척골 및 요골 동맥에 대한 도플러 초음파 유도 알렌 검사를 시행하여 청각 도플러와 CT-혈관조영술에서는 확인되지 않았던 척골 동맥의 혈류 감소를 인지할 수 있었다. 저자들은 척골 및 요골 동맥에 대한 도플러 초음파 유도 알렌 검사의 유용성에 대한 인식을 높이고자, 그 증례를 문헌고찰과 함께 보고하고자 한다.

  • PDF

Doppler ultrasound를 이용한 교정적 치아 이동 시 치수 혈류량의 변화의 측정- 예비실험 (Changes in pulpal blood flow during orthodontic tooth movement studied by Doppler ultrasound)

  • 임경섭;배영민;차정열;유형석;황충주
    • 대한치과교정학회지
    • /
    • 제39권6호
    • /
    • pp.372-382
    • /
    • 2009
  • 교정적 치아 이동 시 지속되는 압력에 의해 혈류변화가 발생하게 되며, 이러한 변화양상에 있어서 선학들의 연구 방법 및 그 결과의 다양성이 존재하였다. 본 연구에서는 Doppler ultrasound를 이용하여, 교정치료 전과 교정치료 시작 3주, 6주 후 치수 혈류량의 연속적인 변화를 알아보고자 하였다. 만 15세 이상 환자 18명을 연구대상으로 Doppler ultrasound를 이용하여 상, 하악 6전치 중 경도의 총생(2 mm 미만)을 보이는 치아(총생측정: required space-available space)와 인접치아를 포함한 3개의 치아를 대상으로 치수 혈류량의 변화를 알아보았다. 연구결과 부위별(상, 하악), 치아별, 기간에 따른 치수 혈류량의 변화는 교정 치료 시작 전과 시작 후 3주, 6주 혈류량에 유의한 차이가 없었다. 또한 치수 생활력 상실의 내재적 위험성을 비교하고자 교정 치료 시작 전 치아별로 치수혈류량을 비교하였을 때, 상악에서는 측절치, 하악에서는 견치에서 통계학적으로 유의한 차이는 나타나지 않았지만, 모든 항목에서 적은 값을 나타냈다 (p > 0.05). 본 연구의 결과는 이후에 진행될 Doppler ultrasound의 치아이동유형, 환자의 연령을 고려한 세부적인 실험 시 방법론적인 기초 자료로서 뿐만 아니라, 교정치료 시 치수 생활력의 상실에 대한 참고 자료가 될 수 있을 것이다.

태아심음주기의 검출을 위한 고해상 피치 검출 알고리즘 (High Resolution Pitch Determination Algorithm for Fetal Heart Rate Extraction)

  • 이응구;이두수
    • 전자공학회논문지B
    • /
    • 제31B권2호
    • /
    • pp.80-87
    • /
    • 1994
  • Fetal monitoring is a routine procedure to obtain a record of physiologic functions during pregnancy and labor. It is required to determine fetal heart frequency accurately. There are various types of fetal heart rate(FHR) determination and the most frequently applied method is transabdominal Doppler ultrasound. However, in the case of weak or noise corrupted Doppler ultrasound signals, conventional peak detections and the autocorrelation function method have many difficulties to determine FHR precisely. Also the autocorrelation function is effected by threshold level and window size. To solve these problems, the high resolution pitch determination algorinthm is introduced to detect FHR from Doppler ultrasound signals. This scheme digitally processes Doppler ultrasound signal for digital rectification, envelope detection, decimation and correlation calculation of two interconnected segments and then FHR is determined by its maximal value. Even in the case of a greatly smeared noise signal, this algorithm is able to search FHR more accurately than autocorrelation function by means of compensating FHR with a constant correlation threshold. This algorithm is simulated by 386-MATLAB on PC 486/DX and verified that it is superior to the autocorrelation function method.

  • PDF

Power Doppler ultrasound-guided sialography using the phenomenon of increased blood flow: A technical report

  • Oh, Song Hee;Seo, Yu-Kyeong;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • 제49권4호
    • /
    • pp.301-306
    • /
    • 2019
  • Purpose: This report presents a procedure for performing power Doppler ultrasound-guided sialography using the phenomenon of increased blood flow and illustrates its application to practical patient cases. Materials and Methods: The salivary gland was scanned using ultrasound equipment (GE LOGIQ5 Expert® device; GE Medical Systems, Milwaukee, WI, USA) to identify pathological findings related to the patient's chief complaint. To identify the orifice of the main duct, it should be cannulated using a lacrimal dilator. After inserting the catheter into the cannulated main duct, the position of the catheter within the duct was confirmed by ultrasound. A contrast agent was injected until the patient felt fullness, and ultrasound (B-mode) was used to confirm whether the contrast agent filled the main canal and secondary and tertiary ducts. Then, power Doppler ultrasound was performed to determine whether the salivary gland had increased blood flow. Results: In 2 cases in this report, a power Doppler ultrasound scan showed a significant increase in blood flow after contrast medium injection, which was not observed on a preoperative scan. Conclusion: Power Doppler ultrasound was found to be a simple, safe, and effective tool for real-time sialography monitoring.

휴대용 초음파진단기를 위한 펄스 도플러 갭 필링 알고리즘의 개선 (Improvements of Pulse Doppler Gap Filling Algorithms for Portable Medical Ultrasound Imaging System)

  • 배무호;안형준
    • 한국음향학회지
    • /
    • 제31권8호
    • /
    • pp.580-589
    • /
    • 2012
  • 이 논문에서는 휴대용, 또는 저가형 초음파진단기에 비교적 고급 기능인 도플러 갭 필링 모드를 적용하고자할 때 적합한 알고리즘들을 찾아보았고, 그 결과 미러링 기반, 또는 자기회귀 모델 기반의 알고리즘들을 찾을 수 있었다. 또, 계산량이 지나치게 많아지지 않는 범위 내에서, 그러한 알고리즘들의 성능의 문제점을 보완하여 더욱 개선시켰다. 수정된 알고리즘들은 인공적으로 발생시킨 도플러 신호 및 실제 초음파장비를 써서 인체로부터 획득한 도플러 데이터를 써서 시뮬레이션 및 실험을 함으로써 유효성을 확인하였다.

INDUSTRIAL MATHEMATICS IN ULTRASOUND IMAGING

  • JANG, JAESEONG;AHN, CHI YOUNG
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제20권3호
    • /
    • pp.175-202
    • /
    • 2016
  • Ultrasound imaging is a widely used tool for visualizing human body's internal organs and quantifying clinical parameters. Due to its advantages such as safety, non-invasiveness, portability, low cost and real-time 2D/3D imaging, diagnostic ultrasound industry has steadily grown. Since the technology advancements such as digital beam-forming, Doppler ultrasound, real-time 3D imaging and automated diagnosis techniques, there are still a lot of demands for image quality improvement, faster and accurate imaging, 3D color Doppler imaging and advanced functional imaging modes. In order to satisfy those demands, mathematics should be used properly and effectively in ultrasound imaging. Mathematics has been used commonly as mathematical modelling, numerical solutions and visualization, combined with science and engineering. In this article, we describe a brief history of ultrasound imaging, its basic principle, its applications in obstetrics/gynecology, cardiology and radiology, domestic-industrial products, contributions of mathematics and challenging issues in ultrasound imaging.

효율적인 혈류 속도 측정을 위한 연속 초음파 도플러 장치의 구현 (An implementation of the continuous wave doppler system for blood flow measurement using the ultrasound)

  • 박형재;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2001년도 춘계종합학술대회
    • /
    • pp.516-519
    • /
    • 2001
  • 환자를 진단하는데 있어 중풍, 고혈압, 동맥경화, 고지혈증 등 혈관 질환에 대해서 혈류에 관한 정보는 매우 중요하다. 초음파를 이용하여 혈류 속도를 측정하는 방법에는 연속 도플러 시스템과 펄스 도플러 시스템으로 나뉘어진다. 펄스 도플러 시스템은 혈류의 위치정보를 얻을 수 있지만, 연속 도플러 시스템에 비해 하드웨어적으로 복잡하고 신호대 잡음비가 낮으므로 본 연구에서는 신뢰적인 정보를 얻을 수 있는 연속 도플러 시스템을 이용하였다. 본 시스템은 크게 아날로그 부와 디지털 부로 나뉘어진다. 아날로그 부는 초음파 신호의 발생부, 초음파 센서로 수신된 신호를 증폭하는 증폭부와 혈류의 도플러 신호를 검출하는 복조부, 잡음 제거를 위한 필터부분으로 구성되어 있다. 디지털 부는 검출된 아날로그 신호를 디지털 신호로 변환하는 부분, 디지털 신호처리 부분 그리고 개인용 컴퓨터(Personal Computer)와 통신하는 부분으로 구성된다. 본 연구에서는 효율적인 초음파 혈류 속도 측정 시스템을 구현함으로써 환자의 혈류 정보를 실시간으로 인을 수 있으므로 뇌혈류 측정 등에 사용되는 전산화 단층 환영장치(Computered Tomography), 자기 공명 영상 촬영장치(Magnetic Resonance Imaging)와 같은 장비와 더불어 보다 정확한 진단을 하는데 유용하다.

  • PDF

양방향 흐름 팬텀 모델에서 탄산수의 도플러 유체 효과 연구 (Study of Doppler Fluid Effects of Carbonated Water in a Bi-directional Flow Phantom Model)

  • 김지혜;허영철
    • 한국방사선학회논문지
    • /
    • 제18권2호
    • /
    • pp.83-91
    • /
    • 2024
  • 본 연구에서는 양방향 흐름 팬텀 모델에서 탄산수의 도플러 유체 효과를 확인하고자 하였다. 양방향 흐름 팬텀 모델은 동맥과 정맥의 흐름을 구현한 것이며 이중 수조 구조를 통해 유체의 순환이 가능하고 팬텀의 크기를 줄일 수 있게 고안되었다. 사용된 유체는 탄산수, 소금물, 설탕물, 증류수를 이용하였고 수조 표면에서 깊이 1.5 cm, 3.0 cm에서 초음파 B-mode와 컬러 도플러 효과를 이용해 초음파 스캔하였다. 컬러 도플러 효과는 탄산수, 소금물, 설탕물, 증류수 모두 도플러 시프트 효과를 나타냈으나 탄산수의 도플러 시프트 효과가 가장 높았고 깊이에 따른 변화에서도 탄산수의 도플러 시프트 효과 편차가 가장 적었다. 결론적으로 탄산수의 도플러 유체 사용 가능성을 확인할 수 있었고 탄산수의 기포가 적혈구의 도플러 반사체 역할을 하고 있음을 확인하였다. 따라서 도플러 초음파 팬텀 제작에서 혈액 모방액과 유사한 물질로 탄산수를 이용한 추가 연구가 필요하며 이에 본 연구가 기초자료를 제공할 것이라 사료 된다.