• 제목/요약/키워드: doppler measurements

검색결과 238건 처리시간 0.02초

라디오존데 관측자료를 이용한 UHF 윈드프로파일러 바람관측자료의 품질평가 (Quality Evaluation of Wind Vectors from UHF Wind Profiler using Radiosonde Measurements)

  • 김광호;김민성;서성운;김박사;강동환;권병혁
    • 한국환경과학회지
    • /
    • 제24권1호
    • /
    • pp.133-150
    • /
    • 2015
  • Wind profiler provides vertical profiles of three-dimensional wind vectors with high spatiotemporal resolution. The wind vectors is useful to analyze severe weather phenomena and to validate the various products from numerical weather prediction model. However, the wind measurements are not immune to ground clutter, bird, insect, and aircraft. Therefore, quality of wind vectors from wind profiler must be quantitatively evaluated prior to its application. In this study, wind vectors from UHF wind profiler at Ganwon Regional Meteorological Administration was quantitatively evaluated using 27 radiosonde measurements that were launched every two or three hours according to rainfall intensity during Intensive Observation Period (IOP) from June to July 2013. In comparison between two measurements, wind vectors from wind profiler was relatively underestimated. In addition, the accuracy and quality of wind vectors from wind profiler decrease with increasing beam height. The accuracy and quality of the wind vectors for rainy periods during IOP were higher than for the clear-air measurements. The moderate rainfall intensity lead to multi-peaks in Doppler spectrum. It results in overestimation of vertical air motion, whereas wind vectors from wind profilers shows good agreement with those from radiosonde measurements for light rainfall intensity.

항공방제용 지면속도 감시장치의 개발 (Development of a Ground Speed Monitoring System for Aerial Application)

  • 구영모;알빈워맥
    • Journal of Biosystems Engineering
    • /
    • 제25권3호
    • /
    • pp.233-240
    • /
    • 2000
  • A commercially available Doppler radar was modified and evaluated for on-board monitoring of ground speed. The radar output was corrected for pitch angle of aircraft based on the output of an electrolytic tilt sensor. The effects of aircraft speed, height and mounting angle on error in the ground speed were evaluated. The speed error decreased with an increase of the mounting angle since the radar contact angle with respect to the ground approached to the mounting angle. The error increased with an increase of the nominal aircraft speed. The altitude insignificantly affected the speed error. The Doppler radar provided acceptable percent errors within 5% in most measurements. The error can be reduced within ${\pm}$1.5% by increasing the mounting angle ($43^{\circ}$). The error of -3.8% at the mounting angle of $29^{\circ}$could be reduced by adjusting the mounting angle with respect to the radar contact angle.

  • PDF

최적화된 샘플링 인수를 갖는 단일 채널 RF 샘플링 방식의 다중점 펄스 도플러 시스템을 사용한 혈류 속도분포 측정 (Volumetric Blood Velocity Measurement on Multigate Pulsed Doppler System based on the Single Channel RF Sampling using the Optimized Sampling Factor)

  • 임춘성;민경선
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권2호
    • /
    • pp.143-152
    • /
    • 1998
  • In this paper, we present the performances of a Doppler system using single channel RF(Radio Frequency) sampling. This technique consists of undersampling the ultrasonic blood backscattered RF signal on a single channel. Conventional undersampling method in Doppler imaging system have to use a minimum of two identical parallel demodulation channels to reconstruct the multigate analytic Doppler signal. However, this system suffers from hardware complexity and problem of unbalance(gain and phase) between the channels. In order to reduce these problems, we have realized a multigate pulsed Doppler system using undersampling on a single channel, It requires sampling frequency at $4f_o$(where $f_o$ is the center frequency of the transducer) and 12bits A/D converter. The proposed " single-Channel RF Sampling" method aims to decrease the required sampling frequency proportionally to $4f_o$/(2k+1). To show the influence of the factor k on the measurements, we have compared the velocity profiles obtained in vitro and in vivo for different intersequence delays time (k=0 to 10). We have used a 4MHz center frequency transducer and a Phantom Doppler system with a laminar stationary flow. The axial and volumetric velocity profiles in the vessel have been computed according to factor k and have been compared. The influence of the angle between the ultrasonic beam and the flow axis direction, and the fluid viscosity on the velocity profiles obtained for different values of k factor is presented. For experiment in vivo on the carotid, we have used a data acquisition system with a sampling frequency of 20MHz and a dynamic range of 12bits. We have compared the axial velocity profiles in systole and diastole phase obtained for single channel RF sampling factor.ng factor.

  • PDF

Echocardiographic Assessment of Papillary Muscle Size and Function in Normal Beagle Dogs

  • Kim, Mijin;Choi, Sooyoung;Choi, Hojung;Lee, Youngwon;Lee, Kija
    • 한국임상수의학회지
    • /
    • 제36권3호
    • /
    • pp.155-158
    • /
    • 2019
  • Morphologic changes or functional impairments of the papillary muscle (PM) can influence mitral valve competence. The purpose of this study was to investigate PM size and contractile function using two-dimensional and color tissue Doppler echocardiography in normal dogs. 35 unsedated Beagle dogs without cardiovascular disease were examined. The vertical (VD) and horizontal diameter (HD) of the posterior and anterior PM was measured at end-diastole, and compared with the thickness of the left ventricular posterior wall (LVPWd). Longitudinal systolic movement of the PM was quantified as myocardial velocity and strain using tissue Doppler. The VD, HD, and ratios (VD/LVPWd, HD/LVPWd, VD/HD) were significantly greater in the posterior than anterior PM (P < 0.001). The VD and HD of posterior PM and the HD of anterior PM were significantly correlated with LVPWd (r = 0.47, 0.44, and 0.42, respectively). Body weight was significantly correlated with VD of posterior PM (r = 0.37). The peak systolic tissue velocity of the PM was $4.93{\pm}1.25cm/sec$ and peak strain was $-30.83{\pm}11.92%$. PM size and systolic function can be quantitatively assessed using two-dimensional and tissue Doppler. The establishment of these objective PM measurements may be useful to evaluate morphological and functional abnormalities of the canine PM.

USBL, DVL과 선수각 측정신호를 융합한 심해 무인잠수정의 항법시스템 (Navigation System for a Deep-sea ROV Fusing USBL, DVL, and Heading Measurements)

  • 이판묵;심형원;백혁;김방현;박진영;전봉환;유승열
    • 한국해양공학회지
    • /
    • 제31권4호
    • /
    • pp.315-323
    • /
    • 2017
  • This paper presents an integrated navigation system that combines ultra-short baseline (USBL), Doppler velocity log (DVL), and heading measurements for a deep-sea remotely operated vehicle, Hemire. A navigation model is introduced based on the kinematic relation of the position and velocity. The system states are predicted using the navigation model and corrected with the USBL, DVL, and heading measurements using the Kalman filter. The performance of the navigation system was confirmed through re-navigation simulations with the measured data at the Southern Mariana Arc submarine volcanoes. Based on the characteristics of the measurements, the design process for the parameters of the system modeling error covariance, measurement error covariance, and initial error covariance are presented. This paper reviews the influence of the outliers and blackout of the USBL and DVL measurements, and proposes an outlier rejection algorithm that is robust to USBL blackout. The effectiveness of the method is demonstrated with re-navigation for the data that includes USBL blackouts.

ADCP 계기 부근에서 발생하는 관측 오차의 실험 및 수치모의에 의한 고찰 (Investigation of Near.Transducer Errors in Acoustic Doppler Current Profiler Measurements Using Experimental and Numerical Method)

  • 김동수;강부식
    • 한국산학기술학회논문지
    • /
    • 제12권2호
    • /
    • pp.944-951
    • /
    • 2011
  • 본 논문은 ADCP 계측기기 부근에서 음향학적인 그리고 ADCP 계기로 인해 발생하는 흐름의 교란에 기인한 속도 오차에 대한 원인들을 실험 및 수치모의를 통해 고찰한다. 실험실에서의 연구는 선박에 탑재되지 않은 독립된 ADCP에 대해 수행하였고, 수평 및 수직면에서 ADCP에 의해 유발되는 흐름 교란은 ADV를 이용하여 관측하였다. 그리고 ADCP와 ADV의 동시적 측정이 ADCP계측에 있어 추가적인 계측기기 부근의 영향들을 고려하기 위해 수행되었다. 수치모의는 ADCP가 선박에 탑재되었을 때 ADCP 계기 부근에 발생하는 잠재적인 오차에 대해 연구하기 위해 설계되었다. 수치해석 기법 사용된 LES (Large Eddy Simulation)는 선박에 탑재된 ADCP에 작용하는 항력과 계기와 선박의 막음효과에 의해 발생하는 흐름의 교란의 크기와 범위를 모의하였다. 결과로 ADCP에 의해 관측된 속도는 계측기기 하단의 제한된 범위 내에서 일정 정도 오차를 보였고 교란되지 않은 하천의 흐름 조건에 따라 오차가 실질적으로 다르게 나타났다.

Sparse reconstruction of guided wavefield from limited measurements using compressed sensing

  • Qiao, Baijie;Mao, Zhu;Sun, Hao;Chen, Songmao;Chen, Xuefeng
    • Smart Structures and Systems
    • /
    • 제25권3호
    • /
    • pp.369-384
    • /
    • 2020
  • A wavefield sparse reconstruction technique based on compressed sensing is developed in this work to dramatically reduce the number of measurements. Firstly, a severely underdetermined representation of guided wavefield at a snapshot is established in the spatial domain. Secondly, an optimal compressed sensing model of guided wavefield sparse reconstruction is established based on l1-norm penalty, where a suite of discrete cosine functions is selected as the dictionary to promote the sparsity. The regular, random and jittered undersampling schemes are compared and selected as the undersampling matrix of compressed sensing. Thirdly, a gradient projection method is employed to solve the compressed sensing model of wavefield sparse reconstruction from highly incomplete measurements. Finally, experiments with different excitation frequencies are conducted on an aluminum plate to verify the effectiveness of the proposed sparse reconstruction method, where a scanning laser Doppler vibrometer as the true benchmark is used to measure the original wavefield in a given inspection region. Experiments demonstrate that the missing wavefield data can be accurately reconstructed from less than 12% of the original measurements; The reconstruction accuracy of the jittered undersampling scheme is slightly higher than that of the random undersampling scheme in high probability, but the regular undersampling scheme fails to reconstruct the wavefield image; A quantified mapping relationship between the sparsity ratio and the recovery error over a special interval is established with respect to statistical modeling and analysis.

Preliminary study on the effects of pergolide on left ventricular function in the horses with pituitary pars intermedia dysfunction

  • Gehlen, Heidrun;Fisch, Judith;Merle, Roswitha;Trachsel, Dagmar S.
    • Journal of Veterinary Science
    • /
    • 제22권5호
    • /
    • pp.64.1-64.12
    • /
    • 2021
  • Background: Pituitary pars intermedia dysfunction (PPID), a neurodegenerative disease leading to reduced dopamine production, is a common disease in aged horses. The treatment is based on administration of the dopamine agonist pergolide. This drug has been related to valvular fibrosis in humans, but the cardiovascular effect of this drug has not yet been investigated in horses. Objectives: To determine whether pergolide induces valvular disease in horses or affects the cardiac function. Methods: Standard, tissue Doppler (TDE) and two-dimensional speckle tracking (STE) echocardiography were performed in horses with diagnosed PPID based on adrenocorticotropic hormone dosage. Measurements taken in horses treated with pergolide were compared with those from untreated horses with nonparametric t-tests. Furthermore, measurements from follow-up examinations performed at least three months after the initial exam were compared with a Wilcoxon signed rank test for repeated measurements in each group. Results: Twenty-three horses were included. None of the 12 horses under treatment developed valvular regurgitation. Furthermore, no differences in the measurements of the left ventricular systolic or diastolic function could be seen between the group of horses with treatment and those without treatment. Measurements taken in the follow-up exam did not differ compared to those taken in the initial exam in both groups. Conclusions: No changes of the left ventricular function assessed by TDE and STE could be shown in a small population of horses with confirmed PPID. Treatment with pergolide did not affect the ventricular function nor induce valvular disease.

Flow Visualizations and Laser Doppler Velocity Measurements in a Fontan Connection

  • Kim, Young-H.;Yoganathan, Ajit P.
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1994년도 춘계학술대회
    • /
    • pp.111-114
    • /
    • 1994
  • Three component velocity measurements with a refractive index-matching technique was used to investigate the flow characteristics in the atrio-pulmomnary (AP) Fontan connection under the steady flow condition. A strong swirl was observed in the extra-cardiac conduit and the main pulmonary artery (MPA). Maximum velocity magnitude in the MPA was about 0.8 m/s near the posterior wall at 6 liter/min. Swirling motion of the flow as well as geometric abnormalities of the connection are important factors in energy loss across Fontan connections.

  • PDF

CFD를 이용한 병열 배열형 상향류식 침전지 수리해석에 관한 연구(I) - 침전지 내 유입유량 불균등 영향 조사 - (Evaluation of Hydraulic Behavior within Parallel arranged Upflow Sedimentation Basin Using CFD Simulation (I) - The influence of feed water inequity-)

  • 박노석;김성수;최종웅;성열붕;강문선
    • 상하수도학회지
    • /
    • 제27권4호
    • /
    • pp.469-477
    • /
    • 2013
  • In order to investigate the influence of feed water inequity on the settling performance for parallel arranged upflow sedimentation basin in domestic G_WTP(Water Treatment Plant), CFD(Computational Fluid Dynamics) simulation were employed and ADV(Acoustic Doppler Velocimeter) measurements were carried out. From the results of both CFD simulations and ADV measurements, the differences among inlet flow rates to each inlet structure make turbulent energy dissipation uneven overall sedimentation basin. Especially local velocities in the near of both side wall were observed over the design overflow rate(74.4 mm/min). Also, it was confirmed that this inequity of inlet flow would exert an serious influence on the turbidity of settled water which is out from 8 troughs. Even though experimental velocities in full scale basin about 20% higher than the simulated, the results of ADV measurement were in good accordance with those of CFD simulations.