• 제목/요약/키워드: doppler measurements

검색결과 239건 처리시간 0.029초

An experimental investigation into cavitation behaviour and pressure characteristics of alternative blade sections for propellers

  • Korkut, Emin;Atlar, Mehmet;Wang, Dazheng
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제5권1호
    • /
    • pp.81-100
    • /
    • 2013
  • During the final quarter of the last century considerable efforts have been spent to reduce the hull pressure fluctuations caused by unsteady propeller cavitation. This has resulted in further changes in propeller design characteristics including increased skew, tip unloading and introduction of "New Blade Sections" (NBS) designed on the basis of the so-called Eppler code. An experimental study was carried out to investigate flow characteristics of alternative two-dimensional (2-D) blade sections of rectangular planform, one of which was the New Blade Section (NBS) developed in Newcastle University and other was based on the well-known National Advisory Committee for Aeronautics (NACA) section. The experiments comprised the cavitation observations and the measurements of the local velocity distribution around the blade sections by using a 2-D Laser Doppler Anemometry (LDA) system. Analysis of the cavitation tests demonstrated that the two blade sections presented very similar bucket shapes with virtually no width at the bottom but relatively favourable buckets arms at the suction and pressure sides for the NACA section. Similarly, pressure analysis of the sections displayed a slightly larger value for the NBS pressure peak. The comparative overall pressure distributions around the sections suggested that the NBS might be more susceptible to cavitation than the NACA section. This can be closely related to the fundamental shape of the NBS with very fine leading edge. Therefore a further investigation into the modification of the leading edge should be considered to improve the cavitation behaviour of the NBS.

반자율무인잠수정의 수중 복합항법 시스템 성능평가를 위한 회전팔 시험 (Rotating Arm Test for Assessment of an Underwater Hybrid Navigation System for a Semi-Autonomous Underwater Vehicle)

  • 이종무;이판묵;김시문;홍석원;서재원;성우제
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.141-148
    • /
    • 2003
  • This paper presents a rotating ann test for assessment of an underwater hybrid navigation system for a semi-autonomous underwater vehicle. The navigation system consists of an inertial measurement unit (IMU), an ultra-short baseline (USBL) acoustic navigation sensor and a doppler velocity log (DVL) accompanying a magnetic compass. The errors of inertial measurement units increase with time due to the bias errors of gyros and accelerometers. A navigational system model is derived to include the error model of the USBL acoustic navigation sensor and the scale effect and bias errors of the DVL, of which the state equation composed of the navigation states and sensor parameters is 25 in the order. The conventional extended Kalman filter was used to propagate the error covariance, update the measurement errors and correct the state equation when the measurements are available. The rotating ann tests are conducted in the Ocean Engineering Basin of KRISO, KORDI to generate circular motion in laboratory, where the USBL system was absent in the basin. The hybrid underwater navigation system shows good tracking performance against the circular planar motion. Additionally this paper checked the effects of the sampling ratio of the navigation system and the possibility of the dead reckoning with the DVL and the magnetic compass to estimate the position of the vehicle.

  • PDF

자연형 수로 내 식생흐름 분석을 위한 실험적 연구 (Experimental Study of Vegetated Flows in the Stream-scale Natural Channel)

  • 류용욱;김지현;지운;강준구
    • 대한토목학회논문집
    • /
    • 제39권5호
    • /
    • pp.587-594
    • /
    • 2019
  • 하천 내 흐름에 대한 식생 밀도의 영향을 조사하기 위해 버드나무가 활착된 하천 규모의 자연형 수로에서 유동 측정 실험을 수행하였다. 식생 내 흐름에 대한 하천 규모 실험은 식생의 반 잠김 조건에 대해 수행되었다. 수로 내 식생대(vegetation patch)는 교차로 형성된 사주의 형상으로 배열되었고 식생 구간과 비식생 구간에서의 흐름을 비교하였다. 3차원 유동 구조는 초음파 유속계(Acoustic Doppler Velocimeter)에 의해 측정되었고 종방향 속도의 연직 분포는 다양한 지점에서의 측정값으로부터 분석되었다. 유속은 식생대의 밀도에 따라 다른 양상을 보여 주는데, 식생 구간와 비식생 구간에서의 흐름 속도의 차이는 밀집된 식생대 주변에서 크게 나타나며 흐름 분포의 형태는 식생대의 하류방향 하단에서 복잡한 모습을 나타낸다. 하류에 위치한 식생대 주변의 흐름은 상류에 설치된 식생대에 의해 교란된 흐름에도 불구하고 유사한 분포를 보여준다.

무선 중계시스템의 무선 궤환 간섭 채널 측정 및 특성 분석 (Characterization of Wireless Feedback Interference Channels of a Wireless Repeater Using Sounding Measurements)

  • 문우식;임성빈;김현채;권낙원
    • 대한전자공학회논문지TC
    • /
    • 제46권1호
    • /
    • pp.40-47
    • /
    • 2009
  • 본 논문에서는 송신안테나에서 송신된 신호가 자신의 수신안테나로 수신되어 발생하는 궤환 간섭 채널을 측정하는 방법과 측정된 데이터를 통해 궤환 간섭 채널을 분석한 결과에 대하여 기술한다. 2 GHz 대역의 WCDMA 신호를 사용하여 고속도로변에서 측정 실험을 하였다. 고속도로변은 고속으로 이동하는 차량에 의해 높은 도플러 주파수와 에너지가 큰 궤환 신호가 발생한다. 채널 측정은 신호발생기의 신호와 수신된 신호를 중간주파수로 다운 컨버트하고 동시에 샘플링하여 저장하였고 저장된 데이터를 LS(Least Square) 알고리즘으로 채널의 계수 값을 구하였다. 채널 분석을 위해 시간에 따른 전력 지연 프로파일과 산란 함수를 계산하고, 지연 확산, 도플러 확산, 핑거의 수, 지연에 따른 감쇄에 대하여 분석한다. 궤환 간섭 채널은 송신안테나와 수신안테나가 고정되어 있고 주위에 있는 이동하는 물체와 고정된 물체에 의해 형성된 다중경로를 통해 발생하는 채널로, 일반적인 기지국과 이동국의 채널 모델과는 다른 특성을 가지고 있다. 따라서 분석된 결과를 이용하여 무선 중계시스템의 설계와 성능검증을 위한 지침을 제시한다.

제주도 하수처리장 해양방류구 인근해역의 늦은 봄철 조류 특성과 조석잔차류에 의한 오염물질의 분포 특성 (Characteristics of Tide-induced Flow and its Effect on Pollutant Patterns Near the Ocean Outfall of Wastewater Treatment Plants in Jeju Island in Late Spring)

  • 김준택;홍지석;문재홍;김상현;김태훈;김수강
    • 한국해양학회지:바다
    • /
    • 제26권2호
    • /
    • pp.63-81
    • /
    • 2021
  • 이 연구에서는 2018년 늦은 봄철을 대상으로, 제주도내 위치한 제주와 보목 하수처리장의 해양방류구 주변 해역의 하수처리 방류수의 이동 특성을 파악하기 위하여 다층 유향·유속계 (Acoustic Doppler Current Meter; ADCP)와 지역규모 해양 수치모델의 가상 추적자 실험을 활용한 분석을 수행하였다. ADCP관측 결과에 의하면 두 하수처리장 모두 방류구 인근 해역의 해수 유동은 비조석 성분 보다 조석 성분이 컸고, 조류는 등수심선과 평행한 방향의 왕복성 운동이 지배적이었다. 조화 분석결과는 제주와 보목 하수처리장 해역 모두 반일주기 유속 성분이 우세한 혼합형 조석특성이 지배적이지만, 보목 하수처리장 주변의 유속 세기가 제주 하수처리장 유속의 50% 정도로 느리고, 조류의 회전성이 제주는 시계 방향, 보목의 경우 반시계 방향으로 지역적으로 차이를 보인다. 특히, 보목 하수처리장 방류구 주변해역은 상대적으로 느린 유속과 더불어 잔차류가 등수심선을 가로질러 연안으로 향하기 때문에 해안을 따라 오염물질이 집적되는데 유리한 환경이다. 고해상도 수치실험은 유속·유향 현장 관측 결과와 유사한 해수 유동 특성을 잘 모의하였으며, 오염물질의 이동확산을 파악하기 위한 추적자 실험을 통하여 잔차성분이 연안을 향하는 보목 하수처리장 연안에서 오염물질 잔류량이 상대적으로 높아질 수 있음을 제시하였다. 이러한 결과는 늦은 봄철에 보목 하수처리장 인근 해역이 상대적으로 약한 조류와 연안을 향하는 잔차성분의 영향으로 하수처리 방류수에 의한 연안 오염 가능성이 높은 환경임을 제시하는 결과이다. 퇴적유기물 조사에서도 보목하수처리장 인근 연안은 중간오염 단계를 보임으로써 조석 잔자류에 의한 연안 오염물질 축적과 그에 따른 연안환경오염의 가능성을 뒷받침하고 있다.

실험적으로 유발된 급성 췌장염 견에서 컬러도플러 초음파를 이용한 전방 십이지장 동맥 혈류의 혈역학적 변화에 대한 평가 (Use of the Color Doppler Ultrasonography for the Evaluation of the Hemodynamic Changes of the Cranial Pancreaticoduodenal Arterial Flow in Experimentally Induced Acute Pancreatitis Dogs)

  • 이해운;엄기동;성윤상;이정민;이종원;이근우;김명철;김두;박선일
    • 한국임상수의학회지
    • /
    • 제20권3호
    • /
    • pp.334-340
    • /
    • 2003
  • For the study of the hemodynamic changes of the cranial pancreaticoduodenal arterial flow(cPDAF) in the dog with acute pancreatitis, acute pancreatitis was experimentally induced in 10 dogs by the injection of oleic acid into the accessory pancreatic duct. The parameters of cPDAF were measured by transcutaneous pulsed-wave Doppler ultrasonography. The hemodynamic changes included resistive indexe(RI), pulsatility index(PI) and maximum velocity (Vmax). Ultrasonographic scans were performed before the induction of pancreatitis and once daily for five days after the induction. The RI, PI and Vmax were increased with day as follows; the RI prior to induction was 0.625$\pm$0.096 (mean$\pm$SD), the PI was 1.117$\pm$0.289 and the Vmax was 0.349$\pm$0.094 m/s. After five days, the RI was 0.727$\pm$0.051 (p<0.0l), the PI was 1.480$\pm$0.284 (p<0.0l) and the Vmax was 0.585:$\pm$0.114 m/s (p<0.00l). These results show that there is some relation between the increase of the RI, PI and Vmax of cPDAF and the progress of acute pancreatitis in dogs. Therefore, the measurements of the hemodynamic changes of cPDAF may be a valuable technique for the evaluation of acute pancreatitis in dogs.

구름레이더를 이용한 대기 공기의 연직속도 추정연구 (Study on the Retrieval of Vertical Air Motion from the Surface-Based and Airborne Cloud Radar)

  • 정은실
    • 대기
    • /
    • 제29권1호
    • /
    • pp.105-112
    • /
    • 2019
  • 대기 중에 지름이 약 1.68 mm 이상인 물방울이 존재하는 경우, 연직방향으로 주사하는 구름레이더에서 미(Mie) 기법을 사용하여 공기의 연직속도를 구할 수 있다. 이 리뷰논문에서는 강수가 있는 작은 적운 구름에서 구름레이더를 사용하여 공기의 연직속도를 구할 수 있는 방법을 정리하였다. 공기의 연직속도는 첫 번째 미(Mie) 최소치가 이론적으로 가지는 낙하속도와 스펙트럼상에서 첫 번째 미(Mie) 최소치가 실제로 관측된 시선속도와의 차이로 추정할 수 있다. 구름레이더가 항공기에 탑재된 경우에는, 항공기의 운동 및 자세각이, 관측된 도플러속도의 연직성분에 영향을 미치므로 이 항들을 보정하여 공기의 연직속도를 구할 수 있다. 항공용 도플러 레이더의 경우, 미(Mie)기법으로 구한 공기의 연직속도는 구름입자로부터 직접 후방산란 되어 관측된 연직속도 및 항공기 운항시스템으로부터 구한 연직속도와 잘 일치하는 결과를 보여주었다. 구름 레이더로부터 미(Mie) 산란 특징을 이용하여 연직속도를 추정하는 이 기술은 강수 및 비강수 구름시스템에서의 연직속도장 매핑(mapping)에 응용할 수 있다. 또한 여러 고도에서의 항공기 관측을 통하여, 연직속도의 총체적인 구조뿐 만 아니라 폭풍우의 성장, 발달, 소멸 주기(life cycle)를 재구성할 수 있을 것으로 기대된다.

탄도형 충격파 치료기의 음향 출력 시험을 위한 Dry Test Bench의 신뢰성 및 유용성 (Reliability and utility of a Dry Test Bench for testing the acoustic output from a ballistic shock wave therapeutic device)

  • 전성중;이민영;권오빈;김종민;최민주
    • 한국음향학회지
    • /
    • 제41권5호
    • /
    • pp.589-600
    • /
    • 2022
  • 탄도형 체외 충격파 치료기의 출력 에너지를 측정하는 Dry Test Bench(DTB)의 신뢰성을 검증하기 위해, 상용 탄도형 충격파 치료기에 대해 Laser Doppler Vibrometer(LDV)로 측정된 충격파의 음향 에너지와 비교했다. 실험 결과, DTB로 측정된 역학적 에너지는, 동일한 출력 설정에서, 5 % 이내의 변동성을 보이며, 치료기의 전 출력 설정 범위에서 LDV로 측정된 충격파의 음향 에너지와 선형적인 상관성(adj. R2 = 0.991)을 확인했다. 두 측정 방법의 상관성과, LDV을 이용하여 공기 및 수중에서 측정된 충격파 음향 에너지의 상관성(adj. R2 = 0.995)을 통합하면, DTB 측정으로부터 수중에서 발생된 충격파의 energy flux density를 평균 7.85 % 오차로 추정된다. DTB는 치료기의 출력에너지에 대한 정보만 제공하기 때문에, IEC61846 및 IEC63045에서 요구하는 다양한 충격파의 음향 출력을 시험하는 도구로 적합하지 않다. 그러나 측정 원리가 단순하고 사용이 용이한 DTB는 제조사 및 사용자가 탄도형 Extracorporeal Shock Wave Therapy(ESWT) 치료기의 성능을 관리하는 목적으로 유용하게 사용될 수 있을 것으로 기대된다.

ADCP 자료의 공간평균을 이용한 평균유속장 산정에 대한 검증 (Validation of Assessment for Mean Flow Field Using Spatial Averaging of Instantaneous ADCP Velocity Measurements)

  • 김동수;강부식
    • 한국환경과학회지
    • /
    • 제20권1호
    • /
    • pp.107-118
    • /
    • 2011
  • While the assessment of mean flow field is very important to characterize the hydrodynamic aspect of the flow regime in river, the conventional methodologies have required very time-consuming efforts and cost to obtain the mean flow field. The paper provides an efficient technique to quickly assess mean flow field by developing and applying spatial averaging method utilizing repeatedly surveyed acoustic Doppler current profiler(ADCP)'s cross-sectional measurements. ADCP has been widely used in measuring the detailed velocity and discharge in the last two decades. In order to validate the proposed spatial averaging method, the averaged velocity filed using the spatial averaging was compared with the bench-mark data computed by the time-averaging of the consistent fix-point ADCP measurement, which has been known as a valid but a bit inefficient way to obtain mean velocity field. The comparison showed a good agreement between two methods, which indicates that the spatial averaging method is able to be used as a surrogate way to assess the mean flow field. Bed shear stress distribution, which is a derived hydrodynamic quantity from the mean velocity field, was additionally computed by using both spatial and time-averaging methods, and they were compared each other so as to validate the spatial averaging method. This comparison also gave a good agreement. Therefore, such comparisons proved the validity of the spatial averaging to quickly assess mean flow field. The mean velocity field and its derived riverine quantities can be actively used for characterizing the flow dynamics as well as potentially applicable for validating numerical simulations.

Assessment of Tissue Perfusion Following Conventional Liposuction of Perforator-Based Abdominal Flaps

  • Dogan, Zeynep Deniz Akdeniz;Sacak, Bulent;Yalcin, Dogus;Pilanci, Ozgur;Tuncer, Fatma Betul;Celebiler, Ozhan
    • Archives of Plastic Surgery
    • /
    • 제44권2호
    • /
    • pp.109-116
    • /
    • 2017
  • Background The effect of liposuction on the perforators of the lower abdominal wall has been investigated in several studies. There are controversial results in the literature that have primarily demonstrated the number and patency of the perforators. The aim of this study was to determine the effect of liposuction on the perfusion of perforator-based abdominal flaps using a combined laser-Doppler spectrophotometer (O2C, Oxygen to See, LEA Medizintechnik). Methods Nine female patients undergoing classical abdominoplasty were included in the study. Perforators and the perfusion zones of the deep inferior epigastric artery flap were marked on the patient's abdominal wall. Flap perfusion was quantitatively assessed by measuring blood flow, velocity, capillary oxygen saturation, and relative amount of hemoglobin for each zone preoperatively, after tumescent solution infiltration, following elevation of the flap on a single perforator, and after deep and superficial liposuction, respectively. Results The measurements taken after elevation of the flap were not significantly different than measurements taken after the liposuction procedures. Conclusions The liposuction procedure does not significantly alter the perfusion of perforator-based abdominal flaps in the early period. The abdominal tissue discarded in a classic abdominoplasty operation can be raised as a perforator flap and has been demonstrated to be a unique model for clinical research.