• Title/Summary/Keyword: domestic wastewater

Search Result 322, Processing Time 0.029 seconds

A Study on Phosphorus and Nitrogen Removal with Unit Operation in the Ferrous Nutrient Removal Process (철전기분해장치(FNR)에서 단위공정에 따른 질소와 인의 제거)

  • Kim, Soo Bok;Kim, Young-Gyu
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.1
    • /
    • pp.83-89
    • /
    • 2013
  • Objectives: The purpose of this experiment was to illuminate the relationship between the phosphorus removal rate of unit operation and the phosphorus removal rate of phosphorus volume loading in the Ferrous Nutrient Removal process, which consists of an anoxic basin, oxic basin, and iron precipitation apparatus. Methods: This study was conducted in order to improve the effect of nitrogen and phosphorus removal in domestic wastewater using the FNR (Ferrous Nutrient Removal) process which features an iron precipitation reactor in anoxic and oxic basins. The average concentration of TN and TP was analyzed in a pilot plant ($50m^3/day$). Results: The removal rate of T-N and T-P were 66.5% and 92.8%, respectively. The $NH_3-N$ concentration of effluent was 2.62 mg/l with nitrification in the oxic basin even though the influent was 17.7 mg/l. The $NO_3$-N concentration of effluent was 5.83 mg/l through nitrification in oxic basin even though the influent and anoxic basin were 0.82 mg/l and 1.00 mg/l, respectively. The specific nitrification of the oxic basin ($mg.NH_3$-Nremoved/gMLVSSd) was 16.5 and specific de-nitrification ($mg.NO_3$-Nremoved/gMLVSSd) was 90.8. The T-P removal rate was higher in the oxic basin as T-P of influent was consumed at a rate of 56.3% in the anoxic basin but at 90.3% in the oxic basin. The TP removal rate (mg.TP/g.MLSS.d) ranged from 2.01 to 4.67 (3.06) as the volume loading of T-P was increased, Conclusions: The test results showed that the electrolysis of iron is an effective method of phosphorus removal. Regardless of the temperature and organic matter content of the influent, the quality of phosphorus in the treated water was both relatively stable and high due to the high removal efficiency. Nitrogen removal efficiency was 66.5% because organic matter from the influent serves as a carbon source in the anoxic basin.

Assessment of water quality index suitability of domestic watersheds (국내유역의 수질지수 적합성 평가)

  • Lee, Sangung;Jo, Bugeon;Kim, Young Do
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.5
    • /
    • pp.371-381
    • /
    • 2022
  • Since tributaries have greater water quality variability than main streams, a comprehensive evaluation method that considers the effects of various parameters rather than one water quality parameter has been introduced for effective water quality management of tributaries, but the characteristic of the watershed is not considered. In this study, the urbanization rate, livestock excreta generation, and industrial wastewater discharge in the Hantan River middle-watershed classify urban and non-urban watersheds, and evaluate the suitability of water quality indexes by watershed characteristics by analyzing water quality characteristics and calculating CCME WQI, RTWQI, and NSFWQI. Factor analysis was used to understand the effect of water quality parameters used to calculate the water quality index on the water quality index results. As a result of the factor analysis, the relationship between CCME WQI, TC, and FC was derived, and the relationship between RTWQI and DO, SS in urban watersheds and NSFWQI and FC in non-urban watersheds was revealed. As a result of evaluating suitability through comparison with BOD and T-P grades, it was interpreted that the suitability of the water quality index was low in urban watersheds and that comprehensive water quality evaluation using RTWQI was possible in non-urban watersheds.

Water Management Plan for the Nakdong River Using TOC and COD (총유기탄소와 화학적산소요구량을 이용한 낙동강 물관리 방안)

  • Bo Eun Kim;Meea Kang;Gyo-Cheol Jeong
    • The Journal of Engineering Geology
    • /
    • v.33 no.1
    • /
    • pp.51-59
    • /
    • 2023
  • The Nakdong river is both a natural resource crucial to underwater ecosystems and a water source for its basin's residents. Industrial wastewater and domestic sewage must meet the relevant standards for discharged water before they can flow into the river. The correlation between old and new measures of organic matter was examined using water quality data from 50 monitoring locations in the main stream of the Nakdong river. The coefficient of determination (R2) for total organic carbon (TOC), the new measure of organic matter, and chemical oxygen demand (COD), the old measure of organic matter, in the main stream of the Nakdong river was 0.6134, indicating high correlation. Water quality at each location assessed using TOC and COD showed disparities that cannot be ignored: quality appeared higher when evaluating the main stream of the Nakdong river using TOC instead of COD. Therefore, there remains a need to review water quality ratings based on TOC; continuous monitoring of COD is also required. In addition, the cause of the difference should be clearly identified to help assess artificial sources of pollution and natural factors affecting organic matter. Water management of the Nakdong river will then be possible using the water quality rating.

Life Cycle Environmental Analysis of Valuable Metal (Ag) Recovery Process in Plating Waste Water (폐도금액내 유가금속(Ag) 회수 공정에 대한 전과정 환경성 분석)

  • Da Yeon Kim;Seong You Lee;Yong Woo Hwang;Taek Kwan Kwon
    • Resources Recycling
    • /
    • v.32 no.2
    • /
    • pp.12-18
    • /
    • 2023
  • In 2018, the demand for silver (referred to as Ag) in the electrical and electronics sector was 249 million tons. The demand stood at 81 million tons in the solar module production sector. Currently, due to the rapid increase in solar module installation, the demand for silver is increasing drastically in Korea. However, Korea's natural metal resources and reserves are insufficient in comparison to their consumption, and the domestic silver ore self-sufficiency rate was as low as 2.2% as of 2021. This implies that a recycling technology is necessary to recover valuable metal resources contained in the waste plating solution generated in the metal industry. Therefore, this study compared and analyzed, the results of the impact evaluation through life cycle assessment according to an improvement in the process of recovery of valuable metals in the waste plating solution. The process improvement resulted in reducing GWP (Global Warming Potential) and ADP(Abiotic Depletion Potential) by 50% and 67%, respectively. The GWP of electricity and industrial water was reduced by 98% and 93%, respectively, which significantly contributed to the minimization of energy and water consumption. Thus, the improvement in recycling technology has a high potential to reduce chemical and energy use and improve resource productivity in the urban mining industry.

Changes of Nitrifying Bacteria Depending on the Presence and Absence of Organic Pollutant in Nak-Dong River (낙동강에서의 유기성 오염 유무에 따른 질화세균의 변화)

  • Jin, Seon-Yeong;Lee, Young-Ok
    • Korean Journal of Microbiology
    • /
    • v.49 no.2
    • /
    • pp.137-145
    • /
    • 2013
  • This study was performed at 2 sites of Nak-Dong River to investigate the changes of nitrifiers depending on the presence and absence of organic pollutants (due to the effluents of domestic wastewater treatment plant, WWTP). Conventional chemical parameters such as T-N, $NH_4$-N, $NO_2$-N, $NO_3$-N were measured and the quantitative nitrifiers at the 2 sites were analyzed comparatively by fluorescent in situ hybridization (FISH) with NSO190 and NIT3, after checking the presence of gene amoA of ammonia oxidizing bacteria (AOB) and 16S rDNA signature sequence for Nitrobacter sp. that belongs to nitrite oxidizing bacteria (NOB). Also ${\alpha}{\cdot}{\beta}{\cdot}{\gamma}$-Proteobacteria were detected using FISH to get a glimpse of the general bacterial community structure of the sites. Based on the distribution structure of the ${\alpha}{\cdot}{\beta}{\cdot}{\gamma}$-Proteobacteria and the measurement of nitrogen in different phases, it could be said that the site 2 was more polluted with organics than site 1. Corresponding to the above conclusion, the average numbers of AOB and NOB detected by NSO160 and NIT3, respectively, at site 2 [AOB, $9.3{\times}10^5$; NOB, $1.6{\times}10^6$ (cells/ml)] was more than those at site 1 [AOB, $7.8{\times}10^5$; NOB, $0.8{\times}10^6$ (cells/ml)] and also their ratios to total counts were higher at site 2 (AOB, 27%; NOB, 34%) than those at site 1 (AOB, 18%; NOB, 23%). Thus, it could be concluded that the nitrification at site 2 was more active due to continuous loading of organics from the effluents of domestic WWTP, compared to site 1 located closed to raw drinking water supply and subsequently less polluted with organics.

Chemical Compositions of Sewage Sludges and Nitrogen Mineralization in Sewage Sludge Applied Soil (하수오니의 화학적 조성과 토양중 질소 무기화)

  • Park, Mi-Hyun;Lee, Seung-Heon;Yoo, Sun-Ho;Kim, Kye-Hoon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.31 no.2
    • /
    • pp.189-196
    • /
    • 1998
  • Swage sludge cakes produced from domestic wastewater treatment plants were collected from 21 different sites throughout Korea, and chemical properties of the sludge samples were determined. Inorganic nutrient contents did not indicate great differences among swage sludges from each sites, whereas the toxic heavy metal contents differed greatly. T-N, $NH_4{^+}-N$ and $NO_3{^-}-N$ contents from 21 sites sludges ranged 2.3-6.0, 291-4284, $1.4-58.8mg\;kg^{-1}$, respectively. Heavy metal (Cd, Cu, Pb and Zn) contents ranged 2.86-58.22, 144.0-5417.3, N.D.-943.5, and $N.D.-8,083mg\;kg^{-1}$, respectively. One of the sludges was treated to soils at rates of 12.5, 25, 50. and 100, $Mg\;ha^{-1}$ and incubated for 12 weeks to determine nitrogen materialization rate. Ammoniun nitrogen content decreased sharply at higher rates of sludge treatment up to 8 weeks after treatment and did not change much, while $NO_3{^-}$ increased at all treatment levels. The net amount of mineralized N of sludge treatment rates (12.5, 25, 50, and $100Mg\;ha^{-1}$) during 12weeks incubation were 189.0, 277.2, 303.8 and $376.6mg\;kg^{-1}$.

  • PDF

Proximate Compositions Changed Before and After Fermentation of Rice Spent Water (발효 전후 쌀뜨물의 일반성분 변화)

  • Kim, Min-Ju;Park, Sung-Soo;Kim, Dong-Ho;Kim, Keun-Sung
    • Journal of Food Hygiene and Safety
    • /
    • v.26 no.3
    • /
    • pp.192-197
    • /
    • 2011
  • Rice spent water (RSW) is generated when rice is rinsed before cooking. RSW has been discarded into sewerages due to its low usage in our daily life and become a major domestic wastewater for many years. But RSW can be used as a value-added resource because it contains various beneficial bioactive components. Therefore, fermented rice spent water (FRSW) has been already produced in our previous value-added fermentation process. In this study, proximate compositions and contents of other typical fermentation products were compared between RSW and FRSW. Both RSW and FRSW contain approximately 99.3% moisture and 0.7% total solids. Compared to those of RSW on a dry basis, carbohydrate content of FRSW was decreased by 44.8% and crude protein, lipid, and ash contents of FRSW were increased by 16.4%, 18.8%, and 36.6%, respectively. In addition, starch granules of RSW were intact as those of rice flour were, but those of FRSW were not. RSW did not have lactic acid, but FRSW had 212.13 and 181.25 g/kg D- and L-lactic acid, respectively. Free amino and ammoniacal nitrogen contents of FRSW were 12 and 7 times higher than those of RSW, respectively. Lactic acid, free amino, and ammonical nitrogen contents were considered to be increased in FRSW because carbohydrates could be disintegrated into lactic acids and proteins into free amino or ammoniacal nitrogens during the fermentation process.

The Analysis of Kinetic Parameters for BNR Process Simulation in Domestic Wastewater (국내하수에 적합한 BNR 공정 시뮬레이션을 위한 최적 동력학적 계수 산출)

  • Kim, Dae-Sung;Park, Myung-Gyun;Ahn, Ho-Chul;Ahn, Won-Sik;Lee, Eui-Sin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1385-1390
    • /
    • 2006
  • 외국에서 ASM 모델의 BNR 적용 연구결과를 국내 하수에 적용하기에는 하수농도, 온도, 슬러지농도 등이 국내와는 달라 적용상 무리가 있다. 본 연구에서 BNR 시뮬레이션을 위한 입력 자료로 활용되는 인자들은 IAWPRC task group에서 제안하는 값들을 사용하되 국내 하수성상에서 필요로 하는 인자들은 직접 실험을 통하여 부분적으로 구해냄으로써 모델 시뮬레이션의 신뢰도를 높이고자 하였다. F/M비의 변화량과 1/SRT과의 관계로부터, 종속영양미생물 생산계수 $Y_H$값을 구한결과, 0.40mg VSS/mg COD였다. 이것을 ASM No.2d에 적용하기 위하여 mg cell COD formed/mg COD oxidized 단위로 환산한 결과 0.58을 나타냈다. H 하수처리장의 1차 침전지 하수를 이용하여 호기성상태에서 OUR Test를 통한 미생물에 의한 유기물 섭취시 산소섭취율 변화를 측정하였다. 호기성상태와 무산소상태에서 구한 쉽게 분해되는 용존성유기물(Ss)값을 비교해보면 각각 35.5mg/L와 39.9mg/L로 약간의 차이는 있으나 유사한 값을 보여주고 있다. 시뮬레이션을 위한 동력학적 계수 중 무산소 상태에서 종속영양미생물의 ${\mu}_{max,H}$$3.56d^{-1}$로 나타났고, 호기성상태에서는 구하면 ${\mu}_{max,H}$$4.2d^{-1}$로 산출되었다. 종속영양미생물의 사멸계수 $b_H$를 구하기 위한 실험에서 초기 OUR의 10%이내가 될 때까지 걸린 시간은 7일정도가 걸렸으며, 사멸률 $b_H$$0.043hr^{-1}$로 나타났다. 독립영양미생물의 최대비성장률 ${\mu}_{max,A}$는 최대암모니아 섭취률을 이용하여 구한 결과 $0.65d^{-1}$로 나타났다.EX>$60%{\sim}87%$가 수심 10m 이내에 분포하였고, 녹조강과 남조강이 우점하는 하절기에는 5m 이내에 주로 분포하였다. 취수탑 지점의 수심이 연중 $25{\sim}35m$를 유지하는 H호의 경우 간헐식 폭기장치를 가동하는 기간은 물론 그 외 기간에도 취수구의 심도를 표층 10m 이하로 유지 할 경우 전체 조류 유입량을 60% 이상 저감할 수 있을 것으로 조사되었다.심볼 및 색채 디자인 등의 작업이 수반되어야 하며, 이들을 고려한 인터넷용 GIS기본도를 신규 제작한다. 상습침수지구와 관련된 각종 GIS데이타와 각 기관이 보유하고 있는 공공정보 가운데 공간정보와 연계되어야 하는 자료를 인터넷 GIS를 이용하여 효율적으로 관리하기 위해서는 단계별 구축전략이 필요하다. 따라서 본 논문에서는 인터넷 GIS를 이용하여 상습침수구역관련 정보를 검색, 처리 및 분석할 수 있는 상습침수 구역 종합정보화 시스템을 구축토록 하였다.N, 항목에서 보 상류가 높게 나타났으나, 철거되지 않은 검전보나 안양대교보에 비해 그 차이가 크지 않은 것으로 나타났다.의 기상변화가 자발성 기흉 발생에 영향을 미친다고 추론할 수 있었다. 향후 본 연구에서 추론된 기상변화와 기흉 발생과의 인과관계를 확인하고 좀 더 구체화하기 위한 연구가 필요할 것이다.게 이루어질 수 있을 것으로 기대된다.는 초과수익률이 상승하지만, 이후로는 감소하므로, 반전거래전략을 활용하는 경우 주식투자기간은 24개월이하의 중단기가 적합함을 발견하였다. 이상의 행태적 측면과 투자성과측면의 실증결과를 통하여 한국주식시장에 있어서 시장수익률을 평균적으로 초과할 수 있는 거래전략은 존재하므로 이러한 전략을 개발 및 활용할 수 있으며, 특히, 한국주식시장에 적합한 거래전략은 반전거래전략이고, 이 전략의 유용성은 투자자가 설정한 투자기간보다 더욱 긴 분석기간의 주식가격정보에 의하여 최대한 발휘될 수 있음을 확인하였다.(M1), 무역적자의 폭, 산업의 생산

  • PDF

End-use analysis of household water by metering (가정용수의 용도별 사용량 조사 및 원단위 분석)

  • Kim, Hwa-Soo;Lee, Doo-Jin;Kim, Ju-Whan;Kim, Jung-Hyun;Jung, Kwan-Soo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.869-877
    • /
    • 2008
  • The purpose of this study is to investigate the trends and patterns of variou kind of water uses in a household by metering in Korea. Water use components are classified by toilet, washbowl, bathing, laundry, kitchen, etc. Flow meters are installed in 146 household selected by sampling in all around Korea. The data are gathered by web-based data collection system from the year 2002 to 2006, considering pre-investigated data such as occupation, revenue, family members, housing types, age, floor area, water saving devices, education, etc. Reliable data are selected by upper fence method for each observed water use component and statistical characteristics are estimated for each residential type to determine liter per capita per day. Estimated domestic per capita day show an indoor water use with the range from $150{\ell}pcd$ to $169{\ell}pcd$ for each housing type as the order of high rise apartment, multi-house, and single house. As the order of consuming amount among water use components, it is investigated that toilet($38.5{\ell}pcd$) is the first, and the second is laundry water($30.8{\ell}pcd$), the third is kitchen($28.4{\ell}pcd$), the fourth is bathtub($24.7{\ell}pcd$), the next is washbowl($15.4{\ell}pcd$). The results are compared with water uses in U.K. and U.S. As life style has been changed into western style, pattern of water use in Korea is tend to be similar with the U.S. water use pattern. Compared with the surveying results by Bradley, on 1985. Thirty liter of total use increased with the advancement of economic level, and a little change of water use pattern can be found. Especially, toilet water take almost half part of total water use and laundry water shows lowest as 11% in surveying at the year of 1985. But, this study shows that 39 liter, 28% of toilet water, has been decreased by the spread of saving devices and campaign. It is supposed that the spread large sized laundry machine make by-hand laundry has been decreased and water use increased. Unit water amount of each end-use in household can be applied to design factor for water and wastewater facilities, and it play a role as information in establishing water demand forecasting and conservation policy.

  • PDF

Eco-friendly and efficient in situ restoration of the constructed sea stream by bioaugmentation of a microbial consortium (복합미생물 생물증강법을 이용한 인공해수하천의 친환경 효율적 현장 수질정화)

  • Yoo, Jangyeon;Kim, In-Soo;Kim, Soo-Hyeon;Ekpeghere, Kalu I.;Chang, Jae-Soo;Park, Young-In;Koh, Sung-Cheol
    • Korean Journal of Microbiology
    • /
    • v.53 no.2
    • /
    • pp.83-96
    • /
    • 2017
  • A constructed sea stream in Yeongdo, Busan, Republic of Korea is mostly static due to the lifted stream bed and tidal characters, and receives domestic wastewater nearby, causing a consistent odor production and water quality degradation. Bioaugmentation of a microbial consortium was proposed as an effective and economical restoration technology to restore the polluted stream. The microbial consortium activated on site was augmented on a periodic basis (7~10 days) into the most polluted site (Site 2) which was chosen considering the pollution level and tidal movement. Physicochemical parameters of water qualities were monitored including pH, temperature, DO, ORP, SS, COD, T-N, and T-P. COD and microbial community analyses of the sediments were also performed. A significant reduction in SS, COD, T-N, and COD (sediment) at Site 2 occurred showing their removal rates 51%, 58% and 27% and 35%, respectively, in 13 months while T-P increased by 47%. In most of the test sites, population densities of sulfate reducing bacterial (SRB) groups (Desulfobacteraceae_uc_s, Desulfobacterales_uc_s, Desulfuromonadaceae_uc_s, Desulfuromonas_g1_uc, and Desulfobacter postgatei) and Anaerolinaeles was observed to generally decrease after the bioaugmentation while those of Gamma-proteobacteria (NOR5-6B_s and NOR5-6A_s), Bacteroidales_uc_s, and Flavobacteriales_uc_s appeared to generally increase. Aerobic microbial communities (Flavobacteriaceae_uc_s) were dominant in St. 4 that showed the highest level of DO and least level of COD. These microbial communities could be used as an indicator organism to monitor the restoration process. The alpha diversity indices (OTUs, Chao1, and Shannon) of microbial communities generally decreased after the augmentation. Fast uniFrac analysis of all the samples of different sites and dates showed that there was a similarity in the microbial community structures regardless of samples as the augmentation advanced in comparison with before- and early bioaugmentation event, indicating occurrence of changing of the indigenous microbial community structures. It was concluded that the bioaugmentation could improve the polluted water quality and simultaneously change the microbial community structures via their niche changes. This in situ remediation technology will contribute to an eco-friendly and economically cleaning up of polluted streams of brine water and freshwater.