• 제목/요약/키워드: distribution system an)

검색결과 6,324건 처리시간 0.036초

22.9kV 배전선로 중성선 설치 구조에 따른 유도뢰 차폐효과 분석 (Analysis on the Induced Lightning Shielding Effect According to the Neutral Wire Installation Structure of a 22.9kV Distribution Line)

  • 김점식;김도영;박용범
    • 전기학회논문지P
    • /
    • 제59권2호
    • /
    • pp.191-196
    • /
    • 2010
  • The electricity distribution system in Korea is adopting a multi-grounding system. Protection of this distribution system against lightning is performed by installing overhead ground wires over the high voltage wires, and connecting the overhead ground wires to the ground every 200 m. The ground resistance in this system is limited not to exceed $50\Omega$ and overhead ground wire and neutral wire are multiple parallel lines. Although overhead ground wire and neutral wire are installed in different locations on the same pole, this circuit configuration has duplicated functions of providing a return path for unbalanced currents and protecting the distribution system against induced lightning. Therefore, the purpose of this study is to analyze the induced lightning shielding effect according to the neutral wire installation structure of a 22.9kV distribution line in order to present a new 22.9kV distribution line structure model and characteristics. This study calculated induced lightning voltage by performing numerical analysis when an overhead ground wire is present in the multi-grounding type 22.9kV distribution line structure, and calculated the induced lightning shielding effect based on this calculated induced lightning voltage. In addition, this study proposed and analyzed an improved distribution line model allowing the use of both overhead wire and neutral wire to be installed in the current distribution lines. The result of MATLAB simulation using the conditions applied by Yokoyama showed almost no difference between the induced lightning voltage developed in the current line and that developed in the proposed line. This signifies that shielding the induced lightning voltage through overhead wire makes no difference between current and proposed distribution line structures. That is, this study found that the ground resistance of the overhead wire had an effect on the induced lightning voltage, and that the induced lightning shielding effect of overhead wire is small.

블록체인 기술을 이용한 학교문서위조 예방모델의 연구 (Study of a prevention model against institutional documentation forgery using blockchain technology)

  • 김기홍;김동철
    • 한국중재학회지:중재연구
    • /
    • 제28권2호
    • /
    • pp.165-178
    • /
    • 2018
  • Exchanging information with a person without credentials over the Internet does not pose any problems. A decentralized system based on blockchain technology enables the user to exchange new value(currency) with other uncredited users. The blockchain technology creates a new paradigm in which the distribution system can be founded on trust. Various applied distribution systems are being developed based on this paradigm. This study analyzed the problems between an institute's grading system and the central administration system. The limitations of an institute's current central management system were presented through actual cases. To improve the problem, a decentralized system based on block chain technology was presented in order to overcome the fundamental limitations by utilizing blockchain technology, peer-to-peer network, and the distribution system. In the central system, a malicious moderator could create a malicious edit that becomes the cause of a dispute, but in a decentralized system, a problem cannot be created even if there were to be a malicious moderator. However, it is difficult for a single college institute to create a distribution system in order to actualize an effective system. Comparatively, it would be possible to create a decentralized system in which all educational institutes in Korea (elementary schools, middle schools, high schools, colleges) took part in. The application of a decentralized system would improve the public transparency and reliability of educational institutes.

A Techno-Economic Feasibility Analysis on LVDC Distribution System for Rural Electrification in South Korea

  • Afamefuna, David;Chung, Il-Yop;Hur, Don;Kim, Ju-Yong;Cho, Jintae
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권5호
    • /
    • pp.1501-1510
    • /
    • 2014
  • Low voltage direct current (LVDC) distribution system is a suitable techno-economic candidate which can create an innovative solution for distribution network development with respect to rural electrification. This research focuses on the use of LVDC distribution system to replace some of KEPCO's existing traditional medium voltage alternating current (MVAC) distribution network for rural electrification in South Korea. Considering the technical and economic risks and benefits involved in such project, a comparative techno-economic analysis on the LVDC and the MVAC distribution networks is conducted using economic assessment method such as the net present value (NPV) on a discounted cash flow (DCF) basis as well as the sensitivity analysis technique. Each would play a role in an economic performance indicator and a measure of uncertainty and risk involved in the project. In this work, a simulation model and a computational tool are concurrently developed and employed to aid the techno-economic analysis, evaluation, and estimation of the various systems efficiency and/or performance.

뇌충격전류에 의한 산화아연형 피뢰기 소자의 전기적 특성과 피뢰기 열화진단 전문가 시스템 (Electrical Characteristics of ZnO Blocks by a Lightning Impulse Current and the Expert System to Diagnose Arrester Deterioration)

  • 길경석;한주섭;송재용;김명진;김정배;조한구
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권4호
    • /
    • pp.152-157
    • /
    • 2002
  • This paper describes an effect of a single- and a quadruple-lightning impulse currents on electrical characteristics of ZnO blocks, and an expert system to diagnose arrestor deterioration. To deduce the parameters needed for diagnosing arrester deterioration, an accelerate deterioration teat is carried out. In the experiment, leakage current components are measured. Also, wave height distribution of the leakage current according to the progress of arrester deterioration is analyzed. From the experimental results, the wave height distribution of the leakage current showed conspicuous difference even in an immaterial leakage current increase. Therefore, the use of wave height distribution of the leakage current in deterioration diagnostic technique makes more accurate diagnosis than the conventional method by using only a leakage currant value. Finally, the expert system based on the experimental results is developed and the system can diagnose arrestor deterioration by measuring the leakage current and its wade height distribution.

고장전류의 누적 에너지를 이용한 저압직류 배전계통의 고저항 지락고장 검출 알고리즘 개발 (Development of an Algorithm for Detecting High Impedance Fault in Low Voltage DC Distribution System using Accumulated Energy of Fault Current)

  • 오윤식;노철호;김두웅;권기현;한준;김철환
    • 조명전기설비학회논문지
    • /
    • 제29권5호
    • /
    • pp.71-79
    • /
    • 2015
  • Recently, new Low Voltage DC (LVDC) power distribution systems have been constantly researched as uses of DC in end-user equipment are increased. As in conventional AC distribution system, High Impedance Fault (HIF) which may cause a failure of protective relay can occur in LVDC distribution system as well. It, however, is hard to be detected since change in magnitude of current due to the fault is too small to detect the fault by the protective relay using overcurrent element. In order to solve the problem, this paper presents an algorithm for detecting HIF using accumulated energy in LVDC distribution system. Wavelet Singular Value Decomposition (WSVD) is used to extract abnormal high frequency components from fault current and accumulated energy of high frequency components is considered as the element to detect the fault. LVDC distribution system including AC/DC and DC/DC converter is modeled to verify the proposed algorithm using ElectroMagnetic Transient Program (EMTP) software. Simulation results considering various conditions show that the proposed algorithm can be utilized to effectively detect HIF.

방향성 계전기를 고려한 루프 배전계통 신뢰도 평가에 관한 연구 (A Study on the Reliability Estimation of Loop Distribution System Considering Directional Relay)

  • 박진현;조성민;조보현;신희상;김재철
    • 전기학회논문지
    • /
    • 제59권11호
    • /
    • pp.1942-1948
    • /
    • 2010
  • Recently, the radial distribution system is operating as one-way power flow. These are popular because of their simple design and relatively low cost. However, radial systems are sensitive to outages due to single contingencies. Also, reliability of supply is becoming increasingly important. Accordingly, an appearance of the loop distribution system is inevitable and the other countries such as Macau, Florida, Taiwan are actively working on. The reliability of distribution system is estimated with reliability indices. In this paper, comparing with the radial distribution system, we evaluate and analyse the reliability of loop distribution system quantitatively considering directional relay.

신재생에너지원이 연계된 22.9[kV] 배전계통의 양방향 리클로저와 섹셔널라이저 보호협조 방안 (A study of the directional recloser and sectionalizer protective coordination at 22.9[kV] distribution system with new renewable energy generation)

  • 이연화;최준호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.525-526
    • /
    • 2007
  • Recently, there has been growing interest in utilizing distributed generation (DG). However, an insertion of DG to existing distribution system can cause several problems such as voltage variations, harmonics, protective coordination, increasing fault current etc,. The typical protection system of the existing distribution system is designed for radial network. But penetration of DG to distribution system changes existing unidirectional power flow to bidirectional power flow. Therefore, investigation to cover whole field of distribution system must be accomplished such as changing of protection devices rating by increasing fault current, reevaluation of protective coordination. This paper presents that PSCAD/EMTDC simulations was accomplished to analyze effect of DG on the distribution protective coordination. In addition, directional recloser-sectionalizer coordination are evaluates distribution system with DG by using PSCAD/EMTDC simulation.

  • PDF

M/G/c 대기행렬시스템의 대기고객수 분석에 대한 근사법 (An Approximation for the System Size of M/G/c Queueing Systems)

  • 허선;이호현
    • 한국경영과학회지
    • /
    • 제25권2호
    • /
    • pp.59-66
    • /
    • 2000
  • In this paper we propose an approximation analysis for the system size distribution of the M/G/c system which is transform-free,. At first we borrow the system size distribution from the Markovian service models and then introduce a newly defined parameter in place of traffic intensity. In this step we find the distribution of the number of customers up to c. Next we concentrate on each waiting space of the queue separately rather than consider the entire queue as a whole. Then according to the system state of the arrival epoch we induce the probability distribution of the system size recursively. We discuss the effectiveness of this approximation method by comparing with simulation for the mean system size.

  • PDF

Multy-agent system을 애용한 배전계통 최적 보호시스템 연구 (A study on An Optimal Protection System for Power Distribution Networks by Applying Multi-Agent System)

  • 정광호;민병운;이승재;최면송;강상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.299-301
    • /
    • 2003
  • In this paper, a protection system using Multi-Agent concept for power distribution network is proposed. Multi agent system consist of Feeder agent, OCR(Over Current Relay) agent, Recloser agent and Switch agent. An agent calculates and corrects its parameter by itself through communication with neighboring agents and its own intelligence algorithm. Simulations in a simple distribution network show the effectiveness of the suggested protection system. Multi-Agent System, protection of distribution network, Communication.

  • PDF

SCM환경에서의 물류센터의 최적 서비스 수준 결정 방법 (A study on the Method to Determine Optimal Service Level of a Distribution Center in Supply Chain Management Environment)

  • 조용욱;박명규
    • 대한안전경영과학회지
    • /
    • 제3권3호
    • /
    • pp.55-64
    • /
    • 2001
  • The main objective of this research is to develop a model to select the optimal input service level for a distribution center-multi branch inventory distribution system. With the continuous review policy, the distribution center places an order for specific order quantity to an outside supplier, and the order quantity is replenished after a certain lead time Also, each branch places an order for particular order quantity to the distribution center to satisfy the customer demands, and receives the replenishment after a lead time. When an out of stock condition occurs during an order cycle, a backorder is placed to the upper level to fill the unfilled demands. With these situation, variable demand and variable lead time are used for better industrial practice. Further, actual lead times with a generic lead time distribution are used in developing the control model. Under the actual lead time model, the customer service measures actually attained for the distribution center and each branch are explained as the effective customer service measures. Thus, throughout the optimal control (using computer search procedures), we can select the optimal input service levels for the distribution center and each branch to attain the effective service levels for each branch which is consistent with the goal level of service for each branch. At the same time, the entire distribution system keeps minimum inventories.

  • PDF