• 제목/요약/키워드: distribution system an)

검색결과 6,324건 처리시간 0.04초

Complementary Power Control of the Bipolar-type Low Voltage DC Distribution System

  • Byeon, Gilsung;Hwang, Chul-Sang;Jeon, Jin-Hong;Kim, Seul-Ki;Kim, Jong-Yul;Kim, Kisuk;Ko, Bokyung;Kim, Eung-Sang
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.786-794
    • /
    • 2015
  • In this paper, a new power control strategy for the bipolar-type low voltage direct current (LVDC) distribution system is being proposed. The dc distribution system is considered as an innovative system according to the increase of dc loads and dc output type distribution energy resources (DERs) such as photovoltaic (PV) systems and energy storage systems (ESS). Since the dc distribution system has many advantages such as feasible connection of DERs, reduction of conversion losses between dc output sources and loads, no reactive power issues, it is very suitable solution for new type buildings and residences interfaced with DERs and ESSs. In the bipolar-type, if it has each grid-interfaced converter, both sides (upper, lower-side) can be operated individually or collectively. A complementary power control strategy using two ESSs in both sides for effective and reliable operation is proposed in this paper. Detailed power control methods of the host controller and local controllers are described. To verify the performances of the proposed control strategy, simulation analysis using PSCAD/EMTDC is being performed where the results show that the proposed strategy provides efficient operations and can be applied to the bipolar-type dc distribution system.

다단계 반복기법을 이용한 관로시스템의 최적관경 결정 (determination of Optimum Pipe diameter Using Multi-Stage Iterative Method in Water Distribution system)

  • 한건연;박재홍
    • 한국수자원학회논문집
    • /
    • 제31권3호
    • /
    • pp.327-335
    • /
    • 1998
  • 상수관망은 상수공급시스템에서 핵심적인 부분이다. 주어진 상수공급시스템에서 배수관망에 대한 비용은 사업전체 비용에 대한 대부분을 차지하고 있다. 관망에 대한 설계과정 중에서 최적화기법을 사용하여 비용을 절감하기 위한 연구가 시도되었다. 주어진 상수관망 시스템의 설계시 고려되는 관경의 결정을 위해 유량해석과 최적화 기법이 연계되어 해석하는 반복기법이 적용되었다. 유량해석을 위해서 선형화기법이 되입되었고 관경의 최적화를 위해서 선형계획법에 기초한 개정 단체법을 이용하였다. 22개 관로와 35개 관로를 가진 실제관망에 본 모형을 적용한 결과 짧은 계산시간으로 최적화된 상용관을 결정할 수 있었다.

  • PDF

로봇 Off-Line Programming을 위한 페인트 스프레이 시뮬레이션 방법론 개발 (An Accurate and Efficient Method of the Spray Paint Simulation for Robot OLP)

  • 이승찬;송인호;범진환
    • 한국CDE학회논문집
    • /
    • 제13권4호
    • /
    • pp.296-304
    • /
    • 2008
  • Recently, various attempts are being done to apply off-line programming system to field of paint robot. But most commercial simulation softwares have problems that are slow simulation speed and not support various painting paramenters on simulation. This paper proposes enhanced paint simulation method for off-line programming system. For these, this method used the mathematical model of flux field from a previous research. The flux field has the flux distribution function, which reflects on the feature of paint spray. A previous research derived this flux distribution function for an integral function and calculated paint thickness function for an integral function. But if flux distribution function is defined as an integral function, it is inadequate to use for real-time simulation because a number of calculation is needed for estimation of paint thickness distribution. Therefore, we defined the flux distribution function by numerical method for reducing a mount of calculation for estimation of paint thickness. We derived the equation of paint thickness function analytically for reducing a mount of calculation from the paint distribution function defined by numerical method. In order to prove proposed paint simulation method this paper compares the simulated and measured thickness. From this comparison this paper show that paint thickness distribution is predicted precisely by proposed spray paint simulation process.

GPH 분포에 의한 확률적 근사화 (Probabilistic approximations based on GPH distributions)

  • 윤복식;박광우;이창훈
    • 한국경영과학회지
    • /
    • 제19권1호
    • /
    • pp.85-98
    • /
    • 1994
  • The distribution of random sum of i. i. d. exponential random variables is called GHP (Generalized Phase-Type) distribution. The class of GPH distributions is large enough to include PH (Phase-Type) distributions and has several properties which can be applied conveniently for computational purposes. In this paper, we show that any distribution difined on R$^{+}$ can be app-roximated by the GPH distribution and demonstrate the accuracy of the approximation through various numerical examples. Also, we introduce an efficient way to compute the delay and waiting various numerical examples. Also, we introduce an efficient way to compute the delay and waiting time distributions of the GPH/GPH/1 queueing system which can be used as an approximation model for the GI/G/1 system, and validate its accuracy through numerical examples. The theoretical and experimental results of this paper help us accept the usefulness of the approximations based on GPH distribution.n.

  • PDF

배전운영 시스템에서 상시개방 연계 스위치 투입에 의한 루프 운전 중 구간전압 계산 방법 (Section Voltage Calculation while a Loop Operation by Tie-Switch Close in a Distribution Management System)

  • 서정수;임일형;박종호;신용학;최면송
    • 전기학회논문지
    • /
    • 제65권3호
    • /
    • pp.397-403
    • /
    • 2016
  • Generally, an electrical distribution configuration is a radial system with one-way current in a distribution management system (DMS). All feeders in a DMS have tie-switches to make radial system. Sometimes, DMS should change a tie-switch for operation. In that case, the tie-switch has to be closed first; then a switch is opened as another tie-switch in order to prevent blackout for customers. At the moment when the tie-switch is closed, distribution system is operated in a loop state, not radial. Before the loop operation, DMS operator has to check any expected events for stable distribution system operation; and the most important event is a mis-operation of a protection relay. In addition, DMS operator should check voltage profile violation but a calculation method of section voltages had not been used. Thus, this paper proposes a calculation method of section voltages at a loop operation in a DMS. The proposed calculation algorithm is verified by Matlap Simulink.

DC배전 시스템에서 컨버터 특성에 따른 수용가측 고장 영향 분석 (A Research on the Fault Current of DC distribution system considering Converter Characteristics)

  • 윤태영;변길성;이한상;장길수;채우규;김주용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.366-367
    • /
    • 2011
  • The DC distribution system iis a new promising topologies in a field of future smart distribution system. This system has high efficiency and reliability. So it is expected that there would be an increase in the installation of DC distribution systems. In this paper, the parameter of the DC/DC converter impact on customer's the power quailty in the DC distribution system when the fault occurred. For the analysis, DC network to be modeled using PSCAD/EMTDC. The fault is occurred at phase A in secondary side of MTR which is AC system. Then compared voltage and power at the customer side by varying the capacity of capcitor in the DC/DC converter.

  • PDF

전력 품질 향상을 위한 LVDC 양극성 배전 시스템의 불평형 전압 제어 (Unbalancing Voltage Control of LVDC Bipolar Distribution System for High Power Quality)

  • 이희준;신수철;강진욱;원충연
    • 전력전자학회논문지
    • /
    • 제21권6호
    • /
    • pp.486-496
    • /
    • 2016
  • The voltage unbalance of an LVDC bipolar distribution system was controlled for high power quality. Voltage unbalance may occur in a bipolar distribution system depending on the operation of the converter and load usage. Voltage unbalance can damage sensitive load and lead to converter accidents. The conditions that may cause voltage unbalance in a bipolar distribution system are as follows. First, three-level AC/DC converters in bipolar distribution systems can lead to voltage unbalance. Second, bipolar distribution systems can be at risk for voltage unbalance because of load usage. In this paper, the output DC link of a three-level AC/DC converter was analyzed for voltage unbalance, and the bipolar voltage was controlled with algorithms. In the case of additional voltage unbalance according to load usage, the bipolar voltage was controlled using the proposed converter. The proposed converter is a dual half-bridge converter, which was improved from the secondary circuit of a dual half-bridge converter. A control algorithm for bipolar voltage control without additional converters was proposed. The balancing control of the bipolar distribution system with distributed power was verified through experiments.

ESTIMATION OF SYSTEM RELIABLITY FOR REDUNDANT STRESS-STRENGTH MODEL

  • Choi, In-Kyeong
    • Journal of applied mathematics & informatics
    • /
    • 제5권2호
    • /
    • pp.277-284
    • /
    • 1998
  • The reliability and an estimate for it are derived for series-parallel and parallel-deries stress-strength model under assumption that all components are subjected to a common stress. We also obtain the asymptotic normal distribution of the estimate.

A Model for a Continuous State System with (s,S) Repair Policy

  • Park, Won-J.;Kim, Eui-Yong;Kim, Hong-Gie
    • Journal of the Korean Statistical Society
    • /
    • 제25권1호
    • /
    • pp.111-122
    • /
    • 1996
  • A model for a system whose state changes continuously with time is introduced. It is assumed that the system is modeled by a Brownian motion with negative drift and an absorbing barrier at the origin. A repairman arrives according to a Poisson process and repairs the system according to an (s,S) policy, i.e., he increases the state of the system up to S if and only if the state is below s. A partial differential equation is derived for the distribution function of X(t), the state of the system at time t, and the Laplace-Stieltjes transform of the distribution function is obtained by solving the partial differential equation. For the stationary case the explicit expression is deduced for the distribution function of the stationary state of the system.

  • PDF

GMA 용접공정에서 용접부의 표면 및 이면의 온도분포 (Temperature distribution of top and back surface in GMA welding process)

  • 김영선;조형석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.1408-1411
    • /
    • 1996
  • In arc welding processes, because of the complexity and nonlinearity of heat transfer phenomena, it is often difficult to design an effective control system based upon an exact mathematic model. In this paper, we simulated the welding process for various welding conditions and positions to investigate the variations of temperature distribution for those cases. Those will be used as a preinformation for developing quality control system for arc welding process.

  • PDF