• Title/Summary/Keyword: distribution method

Search Result 17,562, Processing Time 0.054 seconds

ON BAYESIAN ESTIMATION AND PROPERTIES OF THE MARGINAL DISTRIBUTION OF A TRUNCATED BIVARIATE t-DISTRIBUTION

  • KIM HEA-JUNG;KIM Ju SUNG
    • Journal of the Korean Statistical Society
    • /
    • v.34 no.3
    • /
    • pp.245-261
    • /
    • 2005
  • The marginal distribution of X is considered when (X, Y) has a truncated bivariate t-distribution. This paper mainly focuses on the marginal nontruncated distribution of X where Y is truncated below at its mean and its observations are not available. Several properties and applications of this distribution, including relationship with Azzalini's skew-normal distribution, are obtained. To circumvent inferential problem arises from adopting the frequentist's approach, a Bayesian method utilizing a data augmentation method is suggested. Illustrative examples demonstrate the performance of the method.

A Study for the Voltage Analysis Method of Distribution Systems with Distributed Generation (분산전원이 도입된 배전계통의 전압해석 방법에 관한 연구)

  • 김태응;김재언
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.2
    • /
    • pp.69-78
    • /
    • 2003
  • This paper presents a voltage analysis method of distribution systems interconnected with DG(Distributed Generation). Nowadays, small scale DG becomes to be introduced into power distribution systems. But in that case, it is difficult to properly maintain the terminal voltage of low voltage customers by using only ULTC(Under Load Tap Changer). This paper presents a voltage analysis method of distribution systems with DC for proper voltage regulation of power distribution systems with ULTC. In order to develop the voltage analysis method, distribution system modeling method and advanced loadflow method are proposed. Proposed method has been applied to a 22.9 kV practical power distribution systems.

A Study on Power Flow Method of Radial Distribution System using a measured data from FRTU in Distribution Automation System (배전자동화 시스템의 단말장치(FRTU)로부터 취득되는 데이터를 이용한 방사상 배전계통 조류계산 방법에 관한 연구)

  • Kim, Hyung-Seung;Choi, Myeon-Song;Lee, Seung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.286-287
    • /
    • 2015
  • Currently, Studies on improving the reliability of power supply is becoming an important issue because of the increase in demand of the electric power system. Therefore necessity of automation in distribution system is increasing day by day. However, a measured voltage data from FRTU of distribution automation system is incorrect because of installation space limits. Therefore there is a need of system analysis method by considering the characteristics of the distribution system. For a distribution system, applying the power flow method of transmission system has some problems, as distribution is radial system and it has unbalanced load. Therefore power flow by considering the characteristics of the distribution system have been studied. Existing power flow analysis of the distribution system has different methods like direct analysis method, backward/forward sweep method, modified method of newton raphson etc. In this paper, an improved power flow analysis method based on backward/forward sweep method is proposed in order to efficiently operate the distribution automation system. The proposed method of power flow has been verified through the result of case study.

  • PDF

Blank Design for Optimized Thickness Distribution for Axi-symmetric Superplastic Blow Forming (축대칭 초소성 블로성형의 두께분포 최적화를 위한 블랭크 설계)

  • 이정민;홍성석;김용환
    • Transactions of Materials Processing
    • /
    • v.8 no.1
    • /
    • pp.92-100
    • /
    • 1999
  • A procedure is proposed for determining the initial thickness distribution in oder to produce a specified final thickness distribution for the axisymmetrical superplastic blow forming processes. Weighted parameter is introduced to improve the simple ad $d_traction method and the initial blank thickness distribution is obtained by optimizing the weighted parameter. This method is applied to superplastic free bulging process with the uniform thickness distribution of final shape to confirm its validity. The optimum initial blank thickness distributions is obtained from arbitrary axisymmetrical superplastic blow forming processes such as dome, cone and cylindrical cup forming with die contact. It is concluded that the ad $d_traction method with weighted parameter is an effective method for an optimum blank thickness distribution design.esign.

  • PDF

A Study on the Posterior Density under the Bayes-empirical Bayes Models

  • Sohn, Joong-K.Sohn;Kim, Heon-Joo-Kim
    • Communications for Statistical Applications and Methods
    • /
    • v.3 no.3
    • /
    • pp.215-223
    • /
    • 1996
  • By using Tukey's generalized lambda distribution, appoximate posterior density is derived under the Bayes-empirical Bayes model. The sensitivity of posterior distribution to the hyperprior distribution is examined by using Tukey's generalized lambda distriburion which approximate many well-knmown distributions. Based upon Monte Varlo simulation studies it can be said that posterior distribution is sensitive to the cariance of the prior distribution and to the symmetry of the hyperprior distribution. Also posterior distribution is approximately obtained by using the following methods : Lindley method, Laplace method and Gibbs sampler method.

  • PDF

A New Distribution System Power Flow Method Using Symmetrical Components (대칭성분을 이용한 3상 배전계통 조류계산 기법)

  • Choe, Jeong-Hwan;Jeong, Seong-Il;Park, Je-Yeong;Kim, Gwang-Ho;Kim, Jae-Eon;Park, Jong-Geun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.1
    • /
    • pp.15-22
    • /
    • 2002
  • This paper proposes a new power flow method for distribution system analysis by modifying the conventional back/forward sweep method using symmetrical components. Since the proposed method backward and forward sweeps with the variables expressed by symmetrical components, this method reduces computation time for matrix calculations; therefore, it is able to reduce the computational burden for real-time distribution network analysis. The proposed method was also developed to effectively analyze the unbalanced distribution system installing AVR(Auto Voltage Regulator), shunt capacitors. The proposed algorithm was compared with the conventional Back/forward Sweep method by applying both methods to three phase unbalanced distribution system of IEEE 123-bus model, and the test results showed that the proposed method would outperformed the conventional method in real-time distribution system analysis.

DVFS Algorithm Exploiting Correlation in Runtime Distribution

  • Kim, Jung-Soo;Yoo, Sung-Joo;Kyung, Chong-Min
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.9 no.2
    • /
    • pp.80-84
    • /
    • 2009
  • Dynamic voltage and frequency scaling (DVFS) is an effective method to achieve low power design. In our work, we present an analytical DVFS method which judiciously exploits correlation information in runtime distribution while satisfying deadline constraints. The proposed method overcomes the previous distribution-aware DVFS method [2] which has pessimistic assumption on which runtime distributions are independent. Experimental results show the correlation-aware DVFS offers 13.3% energy reduction compared to existing distribution-aware DVFS [2].

Load Flow Algorithm Analysis of Distribution System (배전계통 부하조류계산 알고리즘 비교 분석)

  • Kwak, Do-Il;Kim, Tae-Eung;Ryu, Jae-Hong;Kim, Jae-Eon
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.134-136
    • /
    • 1999
  • Not much work has been carried out on the load flow analysis of distribution networks. This paper introduces Newton-Raphson method using Distflow equation and Forward Sweeping method in the distribution networks. And that efficient solution scheme in a radial distribution network is presented. Also, simulation results of both Newton-Raphson method and Forward Sweeping method applied to a 22.9kV distribution system model with 120 load buses are analized and evaluated.

  • PDF

ANALYSIS OF LOOPED WATER DISTRIBUTION NETWORK

  • Ioan Sarbu
    • Water Engineering Research
    • /
    • v.2 no.3
    • /
    • pp.171-178
    • /
    • 2001
  • There are three methods for analyzing flow and pressure distribution in looped water distribution networks (the loop method, the node method, the element method) taking into consideration hydraulic parameters chosen as unknown. For all these methods the non-linear system of equations can be solved by iterative procedures. The paper presents a different approach to this problem by using the method of variational formulations for hydraulic analysis of water distribution networks. This method has the advantage that it uses a specialized optimization algorithm which minimizes directly an objective multivariable function without constraints, implemented in a computer program. The paper compares developed method to the classic Hardy-Cross method. This shows the good performance of the new method.

  • PDF

Discharge Estimation Using Non-dimensional Velocity Distribution and Index-Velocity Method in Natural Rivers (자연하천에서 무차원 유속분포-지표유속법을 이용한 유량산정)

  • Kim, Chang-Wan;Lee, Min-Ho;Jung, Sung-Won;Yoo, Dong-Hoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.855-859
    • /
    • 2007
  • It is essential to obtain accurate and highly reliable streamflow data for water resources planning, evaluation and management as well as design of hydraulic structures. A new discharge estimation method, which is named 'non-dimensional velocity distribution and index-velocity method,' was proposed in this research. This method showed very close channel discharges which were calculated with the exiting velocity-area method. When velocity-area method is used to estimate channel discharge, it is required to observe point velocities at every desired point and vertical using a current meter like Price-AA. However 'non-dimensional velocity distribution and index-velocity method' is used, it become optional to observe point velocities at every desired point and vertical. But this method can not be applied for the cases of very complex and strongly asymmetric channel cross-sections because non-dimensional velocity distribution by entropy concept may be quite biased from that of natural rivers.

  • PDF