• 제목/요약/키워드: distribution System

검색결과 15,350건 처리시간 0.048초

열화상 이미지를 이용한 배전 설비 검출 및 진단 (Detection and Diagnosis of Power Distribution Supply Facilities Using Thermal Images)

  • 김주식;최규남;이형근;강성우
    • 대한안전경영과학회지
    • /
    • 제22권1호
    • /
    • pp.1-8
    • /
    • 2020
  • Maintenance of power distribution facilities is a significant subject in the power supplies. Fault caused by deterioration in power distribution facilities may damage the entire power distribution system. However, current methods of diagnosing power distribution facilities have been manually diagnosed by the human inspector, resulting in continuous pole accidents. In order to improve the existing diagnostic methods, a thermal image analysis model is proposed in this work. Using a thermal image technique in diagnosis field is emerging in the various engineering field due to its non-contact, safe, and highly reliable energy detection technology. Deep learning object detection algorithms are trained with thermal images of a power distribution facility in order to automatically analyze its irregular energy status, hereby efficiently preventing fault of the system. The detected object is diagnosed through a thermal intensity area analysis. The proposed model in this work resulted 82% of accuracy of detecting an actual distribution system by analyzing more than 16,000 images of its thermal images.

APPLICATION OF DIGITAL ULTRASONIC IMAGE CONSTRUCTION SYSTEM FOR THE DETECTION OF CRACKS IN WATER DISTRIBUTION SYSTEM

  • Lee, Hyun-Dong;Kwak, Phill-Jae;Shin, Hyeon-Jae;Jang, You-Hyun
    • Environmental Engineering Research
    • /
    • 제11권2호
    • /
    • pp.99-105
    • /
    • 2006
  • A digital ultrasonic image construction system was developed for the nondestructive detection of cracks in water distribution pipes. The system consists of PC based ultrasonic testing system and a scanning device. The PC based ultrasonic system has an ultrasonic pulse/receive board for the generation and reception of ultrasonic signals, an analogue to digital conversion board for the digitization of the received ultrasonic signals, and transducers for the ultrasonic sensors. Using this system, the digitized ultrasonic signals were properly constructed in accordance with the position information obtained by scanning device that moves an ultrasonic transducer along the outer surface of pipes. In the construction of the ultrasonic signals, signal processing concepts, such as spatial average and array concept, were considered to enhance the resolution of ultrasonic images of pipe wall. Using the developed system, crack detection experiments were performed in both laboratory and field, which shows promise for crack detection in the water distribution system.

엑티브필터를 사용한 태양광 발전시스템의 출력제어 (Control Method of Output of PV Generation System using Shunt Active Filter)

  • 성낙권;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.225-227
    • /
    • 2002
  • In this paper, novel concept of a photovoltaic(PV) power generation system adding the function of active filter(AF) is proposed. Even PV power generation system can be treated to a harmonics source for the power distribution system, it is necessary that the function of AF system in grid connected PV power generation system. Active Filters intended for harmonic solutions are expending their functions from harmonic compensation of nonlinear loads into harmonic isolation between utilities and consumer, and harmonic damping throughout power distribution system. So, the PV system combined the function of AF system can be usefully applied in power distribution system. Here, the control strategy of PV-AF system is introduced.

  • PDF

22.9kV 배전선로 적용을 위한 DVR 제어시스템 설계 (DVR Control System Design applied to 22.9kV Distribution System)

  • 김희중;정용호;권기현;박태범;전영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.30-32
    • /
    • 2004
  • This paper describes control system design for the DH(dynamic voltage restorer) consisted of a diode rectifier and series inverter applied to 22.9kV distribution system. The DVR control system is consisted of the main two parts. One is a voltage event detector using a neural network and the other is deadbeat controller for the output voltage and current control of the DVR. A simulation model was developed for analyzing performance of the controller and the whole system. The results confirm that the DVR can restore load voltage under the fault of the distribution system.

  • PDF

로지스틱스관리에서 배송센터의 입지선정 (Determining the Location of Distribution Center in Business Logistics)

  • 한수희;오형술
    • 산업경영시스템학회지
    • /
    • 제20권44호
    • /
    • pp.33-46
    • /
    • 1997
  • The location decision problem for distribution center is one of the most important problem in business logistics system. Because the proportion of holding and transportation cost to physical distribution cost in our country exceed the 60%, a corporation must feel strong pressure to investigate the location problem for distribution center. This paper presents an algorithm for determining the best location of distribution center in consideration with physical distribution cost, demand, and customer location. The methods of determining the distribution center location is that firstly many of proposed sites are built up where demand position is distributed, and then optimal location of distribution center is selected.

  • PDF

다구찌의 피드백 제어시스템 내 다수 함수 품질특성 고찰 (Evaluation of Quality Levels with Multiple Probability Distributions Under the Taguchi's Feedback Control System)

  • 송도현;이상헌
    • 경영과학
    • /
    • 제24권1호
    • /
    • pp.77-90
    • /
    • 2007
  • Taguchi assumed that a product characteristic has the uniform distribution in its preventive maintenance limit when deriving the expected loss generated by the quality deviation. But it is reasonable to assume that a product characteristic has the normal distribution than the uniform distribution. On this paper, we first find the optimum inspection interval and the optimum preventive maintenance limit under the truncated triangular distribution. Secondly we use the beta-general distribution and compare with the truncated triangular distribution. By using the numerical examples, we find the optimum inspection interval and the optimum preventive maintenance limit under their distributions. As a result, we find that the beta-general distribution gives the best solution and easy calculation.

분산전원이 도입된 배전계통의 전압해석 방법에 관한 연구 (A Study for the Voltage Analysis Method of Distribution Systems with Distributed Generation)

  • 김태응;김재언
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권2호
    • /
    • pp.69-78
    • /
    • 2003
  • This paper presents a voltage analysis method of distribution systems interconnected with DG(Distributed Generation). Nowadays, small scale DG becomes to be introduced into power distribution systems. But in that case, it is difficult to properly maintain the terminal voltage of low voltage customers by using only ULTC(Under Load Tap Changer). This paper presents a voltage analysis method of distribution systems with DC for proper voltage regulation of power distribution systems with ULTC. In order to develop the voltage analysis method, distribution system modeling method and advanced loadflow method are proposed. Proposed method has been applied to a 22.9 kV practical power distribution systems.

다단계분배시스템에서의 동적 발주계획 수립방안 (A Dynamic Inventory Scheduling Method in Multi-Echelon Distribution Systems)

  • 유영준;이종배
    • 산업공학
    • /
    • 제11권2호
    • /
    • pp.13-24
    • /
    • 1998
  • A distribution system is composed of multiple levels from a producer to customers, and it's objective is to supply customers with goods timely with a prescribed level of quality at a minimum cost. For the installation and operation of multi-echelon distribution system, DRP(Distribution Resource Planning) is widely used. However, because of the characteristic difference of material flow dynamic of each distribution center, it is almost impossible to get the optimal distribution scheduling. In this paper, an improved DRP method to schedule multi-echelon distribution network is proposed so that the lot-size and order point is dynamically obtained to meet the change of demand rate and timing. The experiment is done with various demand pattern, forecast errors of demand and lead times of central distribution center. The proposed method is compared with traditional statistical approach.

  • PDF

라이프라인의 Smart-Pipe 시스템 도입을 위한 이익정량화 방안 (A Methodology to Quantifying Benefit for Implementing Smart-Pipe to Lifeline Systems)

  • 전환돈;김중훈;조문수;백천우;유도근
    • 한국방재학회 논문집
    • /
    • 제8권4호
    • /
    • pp.61-66
    • /
    • 2008
  • 상수관망의 노후화에 따른 잦은 파괴로 인해 보다 효율적인 상수관망 모니터링시스템 구축이 중요한 문제가 되었다. 상수관망의 모니터링 시스템의 하나인 "Smart-Pipe 시스템"은 영구적이며 포괄적인 자동화된 형태의 SIM 시스템으로 기존의 모니터링 시스템에 비해 많은 장점을 가지고 있다. Smart-pipe를 도입하기 위해서는 상수관 파괴를 미리 예측하여 갑작스러운 상수관 파괴를 막는 것과 같이 smart-pipe 설치를 통해 발생하는 간접적 이익의 정량화가 우선되어야 한다. 그러나 이와 관련된 연구는 국내외적으로 매우 미비한 실정이다. 본 연구에서는 smart-pipe의 개념을 기존 상수관 모니터링 시스템과 비교하였으며 smartpipe 설치에 따른 이익을 수용가불편시간으로 정량화하는 방안을 제시하였다. 제안된 방법을 고양시의 상수관망에 적용하여 적용성을 검증하였으며, smart-pipe시스템의 도입을 위한 기초자료로 활용될 수 있을 것으로 판단되었다.

모의배전계통에 초전도한류기의 도입위치에 따른 전류제한 특성 (Current Limiting Characteristics due to Application Location of a Superconducting Fault Current Limiter in a Simulated Power Distribution System)

  • 유일경;김진석;김명후;김재철;임성훈
    • 조명전기설비학회논문지
    • /
    • 제23권12호
    • /
    • pp.90-95
    • /
    • 2009
  • 배전계통에서 전력수요의 증가와 분산전원의 증가로 대용량 변압기의 적용이 불가피하게 되었다. 하지만, 대용량 변압기로 교체할 경우 배전계통에 고장발생시 고장전류의 크기가 증가되어 기존에 설치된 차단기 및 보호기기의 차단용량 초과로 인해 교체에 따른 경제적 비용 상승이 우려된다. 따라서, 대용량 변압기의 교체시 고장전류 증가 문제를 해결하기 위한 방안 중 하나로 초전도한류기를 설치하는 방안을 검토하고 있다. 하지만, 초전도한류기는 도입위치에 따라 ��치 발생 시 초전도한류기의 저항 크기가 다르게 되며, 이로 인해 고장전류 제한효과가 다르게 되며 기존의 보호 장치들의 동작에 영향을 주게 된다. 본 논문에서는 모의 배전계통에 초전도한류기를 적용하였을 경우 도입위치에 따라 전류제한효과를 포함하여, 모선 전압강하, 고장제거에 따른 초전도한류기의 회복특성을 실험을 통해 비교 분석하였다.