• 제목/요약/키워드: distribution System

검색결과 15,350건 처리시간 0.04초

대규모 배전자동화 시스템의 데이터베이스 구축을 위한 시스템 연계 연구 (The study of linkage between systems to make the database of distribution automation system)

  • 하복남;강문호;조남훈;정창수;김재성;이흥호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.419-421
    • /
    • 2001
  • The large distribution automation system for metropolitan city was developed in KEPCO just recently. This system has many functions for remote control and data acquisition, and it will be linked the other computer aided system such as NDIS(new distribution automation system) and SCADA(supervisory control and data acquisition) to construct the database of DAS(distribution automation system).

  • PDF

배전계통에서 분산전원 운전가능 범위에 대한 연구 (A Study on Permissible Operation Limit of Distributed Generation System in Distribution System)

  • 정원재;김태응;김재언
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.19-21
    • /
    • 2001
  • Nowadays, small scale DGS(Distributed Generation System), as a wind power generation or photovoltaic generation, becomes to be introduced into the power distribution system. But in that case it is difficult to properly maintain the terminal voltage of low voltage customers by using only LDC(Line Drop Compensator). So, it is necessary to determine the permissible operation limit of the introduced DGS for proper voltage in distribution system. In this paper clarifies the relationship between LDC voltage regulation principle and real, reactive power of DGS, and examines the permissible operation limit of the introduced DGS in distribution system which the voltage is controlled by LDC.

  • PDF

배전계통 복구능력 평가방안 및 응용 (A New Evaluation Methodology of Service Restoration Capability in Distribution Systems)

  • 임성일;진보건;이승재
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권7호
    • /
    • pp.333-340
    • /
    • 2002
  • To secure a service continuity is one of the most important mission in the ower distribution system operation. In this paper the necessary and sufficient condition to guarantee 100% service restoration capability for any fault on the system is reported. An evaluation methodology of the restoration capability(or restorability) is developed based on the developed restoration conditions. Applications of the developed concept to the system operation in the normal and emergency states, that would enhance the supply reliability of the system are described. They include enhancement of restoration capability adapting to load change, identification of best open switch and supervised switch positions.

휴리스틱 탐색전략을 이용한 배전계통 계획의 급전선 최적 경로 선정 (Optimal Feeder Routing for Distribution System Planning Using a Heuristic Strategy)

  • 최남진;김병섭;신중린
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권11호
    • /
    • pp.566-574
    • /
    • 2000
  • This paper propose a heuristic algorithm based on the Branch-Exchange (BE) method to solve Optimal feeder Routing(OFR) problem for the distribution system planning. The cost function of the OFR problem is consisted of the investment cost representing the feeder installation and the system operation cost representing the system power loss. We propose a properly designed heuristic strategy, which can handle the horizon-year expansion planning problem of power distribution network. We also used the loop selection method which can define the maximum loss reduction in the network to reduce calculation time, and proposed a new index of power loss which is designed to estimate the power loss reduction in the BE. The proposed index, can be considered with both sides, the low voltage side and voltage side branch connected with tie one. The performances of the proposed algorithms and loss index were shown with 32, 69 example bus system.

  • PDF

표면 검사를 위한 조도 균제도 기반 하이브리드 조명계 설계 (Hybrid Illumination System Design based on Illuminance Uniformity for Surface Inspection)

  • 조은덕;김경범
    • 반도체디스플레이기술학회지
    • /
    • 제18권3호
    • /
    • pp.60-65
    • /
    • 2019
  • In this paper, the hybrid illumination system for effectively detecting surface defects in steel plate with lowcontrast, non-uniformity and featureless is designed based on illuminance uniformity. First of all, characteristics of steel plate defects were considered and typical inspection illumination system is implemented. Optimum illumination parameters for uniformly illuminating an inspection area in the typical illumination system are selected based on the illuminance uniformity and illuminance distribution measurement. The illuminance uniformity and illuminance distribution are measured using an illuminometer based on the arduino. Through illuminance distribution analysis of the typical illumination, an hybrid illumination is designed by fusing bi-directional illumination and coaxial illumination. The hybrid illumination showed higher uniformity ratio and illuminance distribution than the typical illuminations. The hybrid illumination system showed the ability to uniformly illuminate the entire inspection region of steel plate surface.

신뢰성이 향상된 배전지능화 시스템의 복구해 알고리즘 (Distributed Restoration Solution Algorithm Improving Reliability in Intelligent Distribution Management System)

  • 임일형;최면송;이승재;이성우;권성철
    • 전기학회논문지
    • /
    • 제58권9호
    • /
    • pp.1651-1657
    • /
    • 2009
  • In this paper, restoration solution algorithm to improve reliability better than restoration system of DAS(Distribution Automation System) is proposed in IDMS(Intelligent Distribution Management System). A strategy of IDMS restoration system to improve reliability and efficiency is proposed by analysis restoration system in DAS. Restoration sequence algorithm, distributed restoration solution algorithm considering a characteristic and a suitable restoration solution algorithm in IDMS are proposed. In the case study, algorithms have testified with example distribution network by C language

System RBDO of truss structures considering interval distribution parameters

  • Zaeimi, Mohammad;Ghoddosian, Ali
    • Structural Engineering and Mechanics
    • /
    • 제70권1호
    • /
    • pp.81-96
    • /
    • 2019
  • In this paper, a hybrid uncertain model is applied to system reliability based design optimization (RBDO) of trusses. All random variables are described by random distributions but some key distribution parameters of them which lack information are defined by variation intervals. For system RBDO of trusses, the first order reliability method, as well as monotonicity analysis and the branch and bound method, are utilized to determine the system failure probability; and Improved (${\mu}+{\lambda}$) constrained differential evolution (ICDE) is employed for the optimization process. System reliability assessment of several numerical examples and system RBDO of different truss structures are proposed to verify our results. Moreover, the effect of different classes of interval distribution parameters on the optimum weight of the structure and the reliability index are also investigated. The results indicate that the weight of the structure is increased by increasing the uncertainty level. Moreover, it is shown that for a certain random variable, the optimum weight is more increased by the translation interval parameters than the rotation ones.

방송 콘텐츠를 위한 안전한 유통 시스템 설계 및 구현 (Design and Implementation of Secure Distribution System for Broadcasting Contents)

  • 이진흥;이혜주;신상욱
    • 정보보호학회논문지
    • /
    • 제17권2호
    • /
    • pp.19-27
    • /
    • 2007
  • HBTV용 방송 콘텐츠 보호 시스템은 기존의 DRM 시스템에서 이용하는 파일 암호화 기술을 적용하기에는 상당한 어려움을 가진다. 따라서 TS 등과 같은 방송 콘텐츠 포맷에 대하여 적응적이면서, 효율적인 암호화 기술과 임의 접근 모드가 제공되어야 한다. 또한, 방송 환경에 적합한 키 분배 메커니즘이 제공되어야 한다. 본 논문에서는 기존의 MPEG 시스템을 변경하지 않고 인코더/디코더에 적용 가능한 암호 기법과 브로드캐스트 키 분배 메커니즘을 제안하고 구현하였다.

국내계통 보호시스템을 고려한 22.9kV 초전도케이블/한류기 설계사양 제안 (Specifications of 22.9kV HTS cables and FCLs considering protection systems in Korean power distribution system)

  • 이승렬;박종영;윤재영;이병준;양병모
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권3호
    • /
    • pp.50-54
    • /
    • 2009
  • In Korea, 22.9kV 50MVA HTS (High Temperature Superconducting) cables and 630A/3kA hybrid SFCLs (Superconducting Fault Current Limiters) have been or are being developed by LS Cable, LS Industrial System, and Korea Electric Power Research Institute. They will be installed at Icheon 154kV Substation for real-power-distribution-system operation in 2010. This paper proposes specification of current limiting resistor/reactor for the SFCL and fault current condition of the HTS cable for applying the superconducting devices to Korean power distribution system, from the viewpoint of power system protection.

배전선로 운전용량 상향에 따른 개폐기 설치 기준 분석 (Analysis of the Switch Installation Criteria by Increasing Operating Capacity in Distribution Line)

  • 조남훈;하복남;이흥호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권6호
    • /
    • pp.290-295
    • /
    • 2002
  • The present assignment in installing the number of switches for distribution line was made on the basis of a normal feeder capacity 7,000kVA in KEPCO(Korea Electric Power Corporation), Korea. But the normal capacity is revised to 10000kVA in 1998. Even increasing limit of the operating capacity of the distribution lines enables us to give some benefit for the operation flexibility and investment cost of the distribution system. It is disadvantageous in the viewpoint of supply reliability. In distribution systems, switches are equipped to improve the reliability of distribution systems by minimizing the outage section due to fault and maintenance. Utility generally improves the reliability by minimizing the length of outage section, which is caused by fault and maintenance, through switch equipment on distribution system. In order to cope with the changes such as operation capacity, it is necessary to study whether the present criteria is reasonable or not, also to confirm whether the present criteria of installing switches in line is improved or not. In this study, we proposes the number of switch per feeder on the basis of present operation capacity in distribution system.