• 제목/요약/키워드: distribution System

검색결과 15,350건 처리시간 0.04초

전력 변환 손실 저감을 위한 하이브리드 주거배전시스템 (A Study on Residential Hybrid Distribution System for Reducing Power Conversion Loss)

  • 변병주;서현욱;최중묵;이영진;최규하
    • 전력전자학회논문지
    • /
    • 제18권5호
    • /
    • pp.413-421
    • /
    • 2013
  • This paper proposes residential hybrid distribution system that can supply AC power and DC power to AC load and DC load at the same time. This hybrid distribution system consists of three parts: bidirectional inverter, step-up converter and step-down converter. Also that is used to supply voltage to home application is classified of AC load and DC load as load characteristics. The performance of proposed hybrid distribution system is validated through the hardware implementation and the experimental results.

CIM 기반의 배전자동화 시뮬레이터 (CIM based Distribution Automation Simulator)

  • 박지승;임성일
    • 조명전기설비학회논문지
    • /
    • 제27권3호
    • /
    • pp.87-94
    • /
    • 2013
  • The main purpose of the distribution automation system (DAS) is to achieve efficient operation of primary distribution systems by monitoring and control of the feeder remote terminal unit(FRTU) deployed on the distribution feeders. DAS simulators are introduced to verify the functions of the application software installed in the central control unit(CCU) of the DAS. Because each DAS is developed on the basis of its own specific data model, the power system data cannot be easily transferred from the DAS to the simulator or vice versa. This paper presents a common information model(CIM)-based DAS simulator to achieve interoperability between the simulator and the DASs developed by different vendors. The CIM-based data model conversion between Smart DMS (SDMS) and Total DAS (TDAS) has been performed to establish feasibility of the proposed scheme.

지역특성을 고려한 배전설비 고장률 산출에 관한 연구 (A Study on Failure Rate Extraction of Distribution System Equipment considering Regional Characteristics)

  • 최규완;채희석;문종필
    • 전기학회논문지P
    • /
    • 제65권3호
    • /
    • pp.199-203
    • /
    • 2016
  • The cost needed to managing equipment is constantly increasing because of increase of power equipment. The regulations such as PAS 55 and ISO 55000 were enacted to manage equipment assets. The advanced management methods such as real-time monitoring, condition evaluation, and health indices are avalable in generation system, transmission system, and substation transformers. However, These methods can not be applied to distribution equipment because of a lot of equipment. Therefore reliability assessment is very important in case of distribution equipment. In this paper, failure rates are extracted considering characteristics of regions, and which are the essential factors to reliability evaluation.

배전계통 부하조류계산 알고리즘 비교 분석 (Load Flow Algorithm Analysis of Distribution System)

  • 곽도일;김태응;류재홍;김재언
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.134-136
    • /
    • 1999
  • Not much work has been carried out on the load flow analysis of distribution networks. This paper introduces Newton-Raphson method using Distflow equation and Forward Sweeping method in the distribution networks. And that efficient solution scheme in a radial distribution network is presented. Also, simulation results of both Newton-Raphson method and Forward Sweeping method applied to a 22.9kV distribution system model with 120 load buses are analized and evaluated.

  • PDF

물류서비스를 고려한 수송-배치문제에 관한 연구 (Distribution-Location Problem with Physical Distribution Service)

  • 강인선;윤덕균
    • 산업경영시스템학회지
    • /
    • 제14권23호
    • /
    • pp.1-6
    • /
    • 1991
  • The physical distribution service(PDS) is essential to evaluate the business logistics system. The PDS combines the inventory service with the lead time to deliver. This paper is presented to model Mixed Zero-One integer programming which is to determine distribution center location and to allocation products, considering delivery lead time, from given candidate locations to given customer markets. A numerical example is given to demonstrate the applicability of Mixed Zero-One integer programming for Distribution-Location problem.

  • PDF

Discrimination of Arcing Faults from Normal Distribution Disturbances by Wave form Distortion Analysis

  • Kim, C. J.
    • Journal of Electrical Engineering and information Science
    • /
    • 제1권2호
    • /
    • pp.52-57
    • /
    • 1996
  • Detection of arcing high impedance faults has been a perplexing in the power distribution protection. Transient analysis of distribution disturbances for fault discrimination from other normal events is important for a secure protection of the power system. A simple parameter of wave form distortion quantification is used to analyze the behaviors of arcing faults and normal distribution disturbances. Theoretical perspectives of the transients were studied and actual disturbances were examined. From this investigation, a discrimination guideline based on the revised crest factor is developed. The discrimination method has a high potential to enhance the reliability and security for the distribution system protection.

  • PDF

Applicability of Messenger Wire for Purpose of Lightning Protection

  • Seo, Hun Chul;Han, Joon;Choi, Sun Kyu;Lee, Byung Sung;Rhee, Sang Bong;Kim, Chul Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.167-174
    • /
    • 2016
  • The Korean distribution line currently consists of overhead ground wires (OHGW), overhead distribution lines, neutral wires (NW), and messenger wires (MW). The MW is installed under the NW. The lightning protection system in Korea is focused on OHGW and lightning arrester and the MW are not considered. Therefore, this paper proposes the applicability of MW for purpose of lightning protection. For this, we analyzed the effects of lightning overvoltage according to the existence of OHGW and MW and the grounding conditions of the MW in the Korean distribution system. The grounding conditions of the MW that we took into consideration were the common or separate grounding of the MW and NW. The analysis based on the equivalent circuit of the distribution pole at each condition was performed. The distribution lines and lightning were modeled using the Electromagnetic Transients Program (EMTP). For each of the installation conditions of the OHGW and MW, the various lightning conditions were simulated and analyzed for both direct and indirect lightning. The simulation results showed that, if the OHGW was not installed in the Korean distribution system, the lightning overvoltage could be reduced by the common grounding of the MW and NW.

농산물 통합유통정보관리시스템 표준화 추진 방향 (The standardization directions on integrated distribution information management system of agricultural products)

  • 민재홍;허미영;박주영
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 춘계학술대회
    • /
    • pp.617-620
    • /
    • 2016
  • 국내 농산물 유통분야는 농산물의 유통효율성 제고와 수급 및 가격의 불안정 문제를 해결하기 위해서는 기존의 농산물 유통 단계별 주체별 기능별로 개별적이고 독립적인 유통 및 물류관리 체계의 한계를 극복하고 전체 공급 사슬의 참여주체 간 상품 물류 정보 자금흐름 등에서 통합 연계 협력체계를 바탕으로 수급안정과 물류효율성 제고를 실현할 수 있는 방안 제시가 필요하다. 따라서 본고는 이러한 방안제시의 일환으로 농산물 유통 프로세스 상의 정보 관리 현황과 문제점을 살펴보고, 이를 기반으로 농산물 유통 정보를 통합 연계 체계를 구축할 수 있는 농산물 통합유통정보시스템 구조에 대한 참조 표준 모델 및 정보 구조의 표준화 방안을 제시하고자 한다.

  • PDF

지중배전시스템의 개선된 중성점 접지방식 제안과 실효성에 대한 해석적 평가 (Proposition of Improved Neutral Grounding Method and Analytical Evaluation on Practicality in Underground Distribution System)

  • 정석산;이종범;장성환;김용갑;권신남
    • 전기학회논문지
    • /
    • 제60권3호
    • /
    • pp.479-485
    • /
    • 2011
  • In 22.9kV underground distribution system, power cables are provided with multiple-point ground in which each neutral line of the distribution cable(A, B, C phases) and three-wire common grounded at every connecting section. But in such grounding methods, circulating current flows between the neutral wire and grounding wire. And power loss due to circulating current also occurs in all conductors. Therefore it is getting necessary reducing circulating current in underground distribution system. This paper presents improved grounding method to overcome such problems. The proposed grounding method eliminates circulating current in the neutral line effectively and is verified that there is no electrical problem or any ineffectiveness of operating protection systems. These analyses are carried out by EMTP/ATPDraw to compare each grounding methods in steady and transient state. This grounding method suggested in this paper can be applied on real distribution system after field tests considering elimination of circulating current was implemented.

Configurations of AC and DC-type Quality Control Center for a New Distribution System FRIENDS

  • Hayashi Yusuke;Saisyo Masaki;Ise Toshifumi;Tsuji Kiichiro
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.497-501
    • /
    • 2001
  • Unbundled power quality service is paid much attention under the circumstances of deregulation and diversification of needs of customers for quality and price of electric power. Moreover, distributed generators (DGs) such as photovoltaic generations and wind turbines will be introduced to distribution system more and more, and reverse flow of active power has possibility to cause new problems in the distribution system such as voltage rise of distribution line and protection problem. Flexible, Reliable and Intelligent Electrical eNergy Delivery System, which is called FRIENDS, has been proposed as one of promising distribution system for such requirements, and intensive studies are under way. One of features of the system is introducing Quality Control Center (QCC) into the system for unbundled power quality service and easy installation of DGs. Two types of QCCs for such purposes are proposed, and simulation results are shown in this paper.

  • PDF