• Title/Summary/Keyword: distribution System

Search Result 15,379, Processing Time 0.037 seconds

A Study on the Effects of Neutral Current by Unbalanced Load in Two Step Type Pole using KEPCO's Distribution System (한전 배전 계통을 이용한 2단장주의 불평형 부하에 따른 중성선 전류의 영향에 관한 연구)

  • Park, K.W.;Seo, H.C.;Kim, C.H.;Jung, C.S.;Yoo, Y.P.;Lim, Y.H.;Lee, W.J.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.3
    • /
    • pp.465-471
    • /
    • 2007
  • The one step type pole and two step type pole are used in KEPCO's distribution system. The neutral current increases in three-phase four-wire distribution system due to unbalanced load. Usually, power line and communication line are installed at contiguity by effect of topography in Korea. To this end, the damages such as electrostatic induction, electromagnetic induction and harmonic induction generated by induced voltage and current are occured in power line and communication line. This paper calculates the neutral current in KEPCO's distribution system using EMTP by composing various simulated conditions. Also, these results are verified by vector analysis.

A Study on the Optimal Warehouse Location Problem by Using the Branch & Bound Algorithm (창고입지선정문제(倉庫立地選定問題)의 최적해법(最適解法)에 관한 연구(硏究))

  • Lee, Deuk-U;Lee, Sang-Yong
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.12 no.1
    • /
    • pp.73-80
    • /
    • 1986
  • This paper deals with the problem of the optimal location of warehouses in the two stage distribution system, i.e., the distribution system where the product is transported from plants to customer areas via warehouses. The Problem is formulated with a zero-one mixed integer programming and an efficient branch and bound algorithm is then used to solve the problem. In order to obtain the solution of this problem, this paper shows the procedure of conversion of two stage distribution system into one stage distribution system. An improved method of solving the linear programming at the nodes and branching decision rule is also showed by this study.

  • PDF

A Study on the New Distribution System of the Customer Inside (새로운 수용가내의 배전시스템에 대한 연구)

  • Park, Hyung-Joon;Kwon, Si-Hyun;Lee, Seung-Whan;Chung, Chan-Soo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.229-232
    • /
    • 2004
  • This paper is about the new Distribution System of the electric customers. The Power loss in the Distribution System is disregarded and rarely managed so far. But, economically, this loss is not small quantity to Ignore. So, in this paper, we suggest that the new Distribution System of the electric customer by simply changing the locations of Power Transformer and other power facilities which is located inside of the customer. And we also show that the Power loss is decreased with this systematic changing by approximated calculation.

  • PDF

Power Distribution System Planning with Demand Uncertainty Consideration

  • Wattanasophon, Sirichai;Eua-arporn, Bundhit
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.20-28
    • /
    • 2008
  • This paper proposes a method for solving distribution system planning problems taking into account demand uncertainty and geographical information. The proposed method can automatically select appropriate location and size of a substation, routing of feeders, and appropriate sizes of conductors while satisfying constraints, e.g. voltage drop and thermal limit. The demand uncertainty representing load growth is modeled by fuzzy numbers. Feeder routing is determined with consideration of existing infrastructure, e.g. streets and canals. The method integrates planner's experience and process optimization to achieve an appropriate practical solution. The proposed method has been tested with an actual distribution system, from which the results indicate that it can provide satisfactory plans.

The Application of a Genetic Algorithm with a Chromosome Limites Life for the Distribution System Loss Minimization Re-Configuration Problem

  • Choi, Dai-Seub
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.111-117
    • /
    • 2007
  • This paper presents a new approach to evaluate reliability indices of electric distribution systems using genetic Algorithm (GA). The use of reliability evaluation is an important aspect of distribution system planning and operation to adjust the reliability level of each area. In this paper, the reliability model is based on the optimal load transforming problem to minimize load generated load point outage in each sub-section. This approach is one of the most difficult procedures and become combination problems. A new approach using GA was developed for this problem. GA is a general purpose optimization technique based on principles inspired from the biological evolution using metaphors of mechanisms such as natural selection, genetic recombination and survival of the fittest. Test results for the model system with 24 nodes 29 branches are reported in the paper.

A Study of the Order of Precedence Investment in Distribution System Using Interruption Cost with Facility Failure Rate (정전비용과 설비고장률을 이용한 배전계통의 설비 투자 순위평가 분석)

  • Chu, Cheol-Min;Kim, Jae-Chul;Moon, Jong-Fil;Lee, Hee-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.258-260
    • /
    • 2005
  • Recently, it is focused on a methodology to estimate a order of precedence investment in distribution power system under competitive electricity market. This paper suggests methodology to evaluate the order as using a sensitivity of system interruption cost in distribution system regarding a failure rate of distribution components. In this paper, by using one of feeder in RBTS model, the order is assessed to compare valuation about sensitivity of interruption cost with valuation about sensitivity of estimated reliability indices. In conclusion, it is shown that results of precedence investment based on each methods are difference.

  • PDF

Fault location identification and protective coordination schemes presentation of distribution system interconnected Distributed Generation (분산전원이 연계된 배전계통의 사고지점 확인 및 보호협조 방안 제시)

  • Choi, Dong-Man;Choi, Joon-Ho;Ro, Kyoung-Soo;Moon, Seung-Il;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.313-315
    • /
    • 2005
  • Recently There has been growing interest in new renewable energy systems with high-energy efficiency due to the increasing energy consumption and environmental pollution problems. But an insertion of new distributed generation to existng power distribution systems can cause several problems such as voltage variations, harmonics, protective coordination, increasing fault current etc, because of reverse power. This paper was applied to fault location defecting a method as each Relay sensing fault current value and carried out short-circuit analysis by MATLAB and PSCAD/EMTDC programs and identity the faulted section o f22.9[kV] distribution system interconnected a large number of distributed generation. The existing protection system of 22.9[kV] power distribution system analyzed and the study on protective coordination recloser and Sectionalzer accomplished

  • PDF

Load Flow Calculation and Short Circuit Fault Transients in AC Electrified Railways

  • Hosseini, Seyed Hossein;Shahnia, Farhad
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2203-2206
    • /
    • 2005
  • A load flow and short circuit fault simulation of AC electrified railway distribution systems is presented with DIgSILENT PowerFactory software. Load flow of electrified railways distribution system with concerning multi train lines and dynamic characteristics of train load is studied for different time laps. The dynamic characteristics of train load in starting and braking conditions with different starting and stopping times and its moving positions makes the load flow complicated so there is a great need in studying the effects of electrified railways on load flow. Short circuit fault transients is also studied and simulated for both power system or traction distribution system and their effects on the operation of the train sets is investigated.

  • PDF

Topology Optimization of Connection Component System Using Density Distribution Method (밀도분포법을 이용한 부재의 연결구조 최적화)

  • 한석영;유재원
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.4
    • /
    • pp.50-56
    • /
    • 2003
  • Most engineering products contain more than one component. Failure occurs either at the connection itself or in the component at the point of attachment of the connection in many engineering structures. The allocation and design of connections such as bolts, spot-welds, adhesive etc. usually play an important role in the structure of multi-components. Topology optimization of connection component provides more practical solution in design of multi-component connection system. In this study, a topology optimization based on density distribution approach has been applied to optimal location of fasteners such as T-shape, L-shape and multi-component connection system. From the results, it was verified that the number of iteration was reduced, and the optimal topology was obtained very similarly comparing with ESO method. Therefore, it can be concluded that the density distribution method is very suitable for topology optimization of multi-component structures.

Topology Design of Connection Component System Using Density Distribution Method (밀도분포법을 이용한 부재의 연결구조 최적화)

  • 한석영;유재원;박재용
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.15-20
    • /
    • 2003
  • Most engineering products contain more than one component. Failure occurs either at the connection itself or in the component at the point of attachment of the connection in many engineering structures. The allocation and design of connections such as bolts, spot-welds, adhesive etc. usually play an important role in the structure of multi-components. Topology optimization of connection component provides more practical solution in design of multi-component connection system. In this study, a topology optimization based on density distribution approach has been applied to optimal location of fasteners such as T-shape, L-shape and multi-component connection system. From the results, it was verified that the number of iteration was reduced, and the optimal topology was obtained very similarly comparing with ESO method. Therefore, it can be concluded that the density distribution method is very suitable for topology optimization of multi-component structures.

  • PDF