• Title/Summary/Keyword: distributed parameter system

Search Result 218, Processing Time 0.027 seconds

A Voltage Bus Conditioner for a High Voltage DC Power Distribution System using High Performance Hysteresis Control (고성능 히스테리 제어를 이용한 고전압 DC 전력시스템을 위한 Voltage Bus Conditioner)

  • La, Jae-Du
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.2
    • /
    • pp.90-98
    • /
    • 2007
  • More and All-Electric Aircraft (AEA) carry many loads with varied functions. In particular, there may be large pulsed loads with short duty ratio, which can affect the normal operation of other loads. In this paper, a bi-directional converter with inductive storage is used as a voltage bus conditioner (VBC) to mitigate voltage transients on the bus. In addition, the constant frequency hysteresis control technique for a VBC is presented. A simple and fast prediction of the hysteresis band-width is implemented by the phase-lock loop control, keeping constant switching frequency. This technique offers the excellent dynamic response in load or parameter variation. The control performance is illustrated by simulated results with the SABER package, The proposed hysteresis control results in the shortest and the smallest excursions.

Heuristics for selecting machine types and determining buffer capacities in assembly/disassembly systems

  • Jeong, Keun-Chae;Kim, Yeong-Dae
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1996.04a
    • /
    • pp.51-54
    • /
    • 1996
  • We deal with a design problem of assembly/disassembly (AD) systems with finite buffer capacities where the times between failures, the times to repair, and the processing times are exponentially distributed with different parameter values. We present a solution procedure for finding the minimum cost configuration which achieves a desired throughput rate for an AD system. The configuration is defined by the types of machines to be used and capacities of buffers in the AD system. Results of computational experiments on randomly generated test problems show that the proposed heuristics give relatively good configurations in a reasonable amount of time.

  • PDF

Fault Location Algorithm with Ground Capacitance Compensation for Long Parallel Transmission Line (장거리 병렬 송전선로용 대지 정전용량 보상에 의한 고장점 표정 알고리즘)

  • Park, Chul-Won;Kim, Sam-Ryong;Shin, Myong-Chul
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.4
    • /
    • pp.163-170
    • /
    • 2005
  • This paper deals with an improved fault location algorithm with compensation ground capacitance through distributed parameter for a long parallel T/L. For the purpose of fault locating algorithm non-influenced by source impedance and fault resistance, the loop method was used in the system modeling analysis. This algorithm uses a positive and negative sequence of the fault current for high accuracy of fault locating calculation. Power system model of 160km and 300km long parallel T/L was simulated using EMTP software. To evaluate of the proposed algorithm, we used the several different cases 64 sampled data per cycle. The test results show that the proposed algorithm was minimized the error factor and speed of fault location estimation.

An Algorithm of fault Location Technique for Long Transmission Line (송전선로의 고장점 표정 알고리즘)

  • Park, C.W.;Kim, S.R.;Shin, M.C.;Nam, S.B.;Lee, B.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.145-147
    • /
    • 2002
  • In this paper, the improved fault locating method using distributed parameter which calculating the reduced voltage and current according to the ground capacitance in long transmission line was proposed. For the purpose of the fault locating algorithm non influenced source impedance, the loop method was used in the system modeling analysis. To enhance the fault locating, zero sequence of the fault current which is variable according to ground capacitance was not used but positive and negative sequence. System model was simulated using EMTP software. To verify the accuracy of proposed method, in different cases 64 sampled data per cycle was used and 160km and 300km long transmission line has fault resistance $0{\Omega}\;and\;100{\Omega}$ respectively was compared.

  • PDF

Transcutaneous Electrical Nerve Stimulation System for Treating Tinnitus based on the Cortex-M4 Microcontroller

  • Lee, Jaeung;Yeom, Hojun
    • International journal of advanced smart convergence
    • /
    • v.5 no.4
    • /
    • pp.10-14
    • /
    • 2016
  • Among the methods of treating tinnitus, the transcutaneous clectrical nerve stimulation (TENS) method of treating by electrical stimulation is common. However, there is a problem that surgical operation is required to stimulate the vagus nerve (VN) main trunk near most of the bronchus. Alternatively, we found that the same effect could be achieved by electrically stimulating the vagus nerve VN branch (Arnold's nerve) distributed in the outer ear. The TENS system for stimulation of vagus nerve has been developed, but it has not been able to implement to stimulate as a parameter optimized for the patient by simultaneously playing the sound of eliminating the tinnitus frequency. Therefore, in this paper, it is important to develop a safe and practical TENS device for tinnitus treatment based on a 32-bit microprocessor that simultaneously applies non-invasive and notched sounds and to develop optimal treatment methods for treating tinnitus.

On State Estimation Using Remotely Sensed Data and Ground Measurements -An Overview of Some Useful Tools-

  • Seo, Dong-Jun
    • Korean Journal of Remote Sensing
    • /
    • v.7 no.1
    • /
    • pp.45-67
    • /
    • 1991
  • An overview is given on stochastic techniques with which remotely sensed data may be used together with ground measurements for purposes of state estimation and prediction. They can explicitly account for spatiotemporal differences in measurement characteristics between ground measurements and remotely sensed data, and are suitable for highly variant space or space-time processes, such as atmosperic processes, which may be viewed as (containing) a random process. For state estimation of static ststems, optimal linear estimation is described. As alternatives, various co-kriging estimation techniques are also described, including simple, ordinary, universal, lognormal, disjunctive, indicator, and Bayesian extersion to simple and lognormal. For illustrative purposes, very simple examples of optimal linear estimation and simple co-kriging are given. For state estimation and prediction of dynamic system, distributed-parameter kalman filter is described. Issues concerning actual implemention are given, and with application potential are described.

Free Vibrations of Arbitrary Tapered Beams with Static Deflections due to Arbitrary Distributed Dead Loads (임의분포 사하중에 정적변위를 갖는 변단면 보의 자유진동)

  • Lee, Byoung-Koo;Lee, Yong
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.38 no.3
    • /
    • pp.50-57
    • /
    • 1996
  • A numerical method is presented to obtain the natural frequencies and mode shapes of the arbitrary tapered beams with static deflection due to arbitrary distributed dead loads. The differential equation governing free vibration of such beams is derived and solved numerically. The double integration method using the trapezoidal rule is used to solve the static behaviour of beams loaded arbitrary distributed dead load. Also, the Improved Euler method and the determinant search method are used to integrate the differential equation subjected to the boundary conditions and to determine the natural frequencies of the beams, respectively. In the numerical examples, the various geometries of the beams are considered : (1) linearly tapered beams as the arbitrary variable cross-section, (2) the triangular, sinusoidal and uniform loads as the arbitrary distributed dead loads and (3) the hinged-hinged, clamped-clamped and hinged-clamped ends as the end constraints. All numerical results are shown as the non-dimensional forms of the system parameters. The lowest three natural frequencies versus load parameter, slenderness ratio and section ratio are reported in figures. And for the comparison purpose, the typical mode shapes with and without the effects of static deflection are presented in the figure. According to the numerical results obtained in this analysis, the following conclusions may be drawn : (1) the natural frequencies increase when the effects of static deflections are included, (2) the effects are larger at the lower modes than the higher ones and (3) it should be betteF to include the effect of static deflection for calculating the frequencies when the beams are supported by both hinged ends or one hinged end.

  • PDF

Energy Efficient Sequential Sensing in Multi-User Cognitive Ad Hoc Networks: A Consideration of an ADC Device

  • Gan, Xiaoying;Xu, Miao;Li, He
    • Journal of Communications and Networks
    • /
    • v.14 no.2
    • /
    • pp.188-194
    • /
    • 2012
  • Cognitive networks (CNs) are capable of enabling dynamic spectrum allocation, and thus constitute a promising technology for future wireless communication. Whereas, the implementation of CN will lead to the requirement of an increased energy-arrival rate, which is a significant parameter in energy harvesting design of a cognitive user (CU) device. A well-designed spectrum-sensing scheme will lower the energy-arrival rate that is required and enable CNs to self-sustain, which will also help alleviate global warming. In this paper, spectrum sensing in a multi-user cognitive ad hoc network with a wide-band spectrum is considered. Based on the prospective spectrum sensing, we classify CN operation into two modes: Distributed and centralized. In a distributed network, each CU conducts spectrum sensing for its own data transmission, while in a centralized network, there is only one cognitive cluster header which performs spectrum sensing and broadcasts its sensing results to other CUs. Thus, a wide-band spectrum that is divided into multiple sub-channels can be sensed simultaneously in a distributed manner or sequentially in a centralized manner. We consider the energy consumption for spectrum sensing only of an analog-to-digital convertor (ADC). By formulating energy consumption for spectrum sensing in terms of the sub-channel sampling rate and whole-band sensing time, the sampling rate and whole-band sensing time that are optimal for minimizing the total energy consumption within sensing reliability constraints are obtained. A power dissipation model of an ADC, which plays an important role in formulating the energy efficiency problem, is presented. Using AD9051 as an ADC example, our numerical results show that the optimal sensing parameters will achieve a reduction in the energy-arrival rate of up to 97.7% and 50% in a distributed and a centralized network, respectively, when comparing the optimal and worst-case energy consumption for given system settings.

Numerical Simulation of a System Heat Pump Adopting an Integral Optimum Regulating Controller (적분형 최적 레귤레이터 적용 시스템 히트펌프 제어 시뮬레이션 연구)

  • Kim, Yongchan;Choi, Jong Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.7
    • /
    • pp.398-405
    • /
    • 2013
  • Small and medium-size buildings employ a multi-distributed individual air-conditioning system that utilizes package air conditioners instead of centralized cooling systems, which can allow easier building management and maintenance, along with a diversification of facility use. Inverter driven system heat pumps have been developed to achieve not only an easy distribution control, allowing free combination of indoor units with different models and different capacities, but also wide applications to intelligent air conditioning. However, the control algorithms of the system heat pump are limited in the open literature, due to complicated operating conditions. In this paper, an inverter-driven system heat pump having two indoor units with electronic expansion valves (EEV) was simulated in the cooling mode. An integral optimum regulating controller employing the state space control method was also simulated, and applied to the system-heat pump system, to obtain efficient control of the MIMO (multi input multi output) system. The simulation model for the controller yielded satisfactory prediction results. The new control model can be successfully utilized as a basic tool in controller design.

Distributed evacuation guide system based on positioning information of passengers in the subway station (승객 위치정보 기반 지하철 분산대피 안내 시스템)

  • Kim, Nammoon;Kim, Youngok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4528-4535
    • /
    • 2014
  • In this paper, a distributed evacuation system based on the positioning information of subway passengers is proposed. Recently, the subway station is becoming complicated by combining with shopping malls, and movie theaters. Compared to the increasing complexity of subway stations, evacuation systems are less complex. Subway passengers in each cell were estimated to use the access point in the subway cells and statistics information. The evacuation route is provided through a direction indicator and push alarm of a smart phone based on estimated the number of passengers and exit information of the subway station. Based on this schemes, a quick and safe evacuation system of subway passengers was proposed. The number of connection passengers was estimated using AP with OpenWrt embedded OS installed. The average error rate of the number of passenger was confirmed to be 15%, 17% and 23% at the confidence parameter of $1{\sigma}$, $2{\sigma}$, and $3{\sigma}$, respectively, through a simulation. The possibility of the system through a simple experiment was examined.