• Title/Summary/Keyword: distortion measure

Search Result 271, Processing Time 0.022 seconds

Introduction of a recent active loudspeaker measurement and assessment method based on IEC60268-21 (IEC60268-21 기반 최신 액티브 스피커 측정 및 분석 기법 소개)

  • LEE, Sinlyul
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.3
    • /
    • pp.241-246
    • /
    • 2021
  • Modern loudspeaker systems are changing an active loudspeaker system that have multiple input channels and power amplifier. So, we cannot measure these active loudspeakers with IEC 60268-5 standard. This paper introduces an IEC 60268-21 standard that can measure an active loudspeaker having many analog and digital and wireless or wired inputs and having various control parameters.

Staff-line and Measure Detection using a Convolutional Neural Network for Handwritten Optical Music Recognition (손사보 악보의 광학음악인식을 위한 CNN 기반의 보표 및 마디 인식)

  • Park, Jong-Won;Kim, Dong-Sam;Kim, Jun-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.7
    • /
    • pp.1098-1101
    • /
    • 2022
  • With the development of computer music notation programs, when drawing sheet music, it is often drawn using a computer. However, there are still many use of hand-written notations for educational purposes or to quickly draw sheet music such as listening and dictating. In previous studies, OMR focused on recognizing the printed music sheet made by music notation program. the result of handwritten OMR with camera is poor because different people have different writing methods, and lens distortion. In this study, as a pre-processing process for recognizing handwritten music sheet, we propose a method for recognizing a staff using linear regression and a method for recognizing a bar using CNN. F1 scores of staff recognition and barline detection are 99.09% and 95.48%, respectively. This methodologies are expected to contribute to improving the accuracy of handwriting.

Metal Artifact Caused by Magnetic Field Strength and Sequence on T1WI-MRI (자기공명영상에서 자장세기와 시퀀스에 따른 아티팩트 변화)

  • Ko, Seong-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.9
    • /
    • pp.302-308
    • /
    • 2010
  • In MRI, the Ferromagnetic artifact is generated by the metalization within in which the before inspection removal is impossible and the distortion of an image is brought. The distortion measure according to the steel for each sequence of T1 image and magnetic field intensity are analyzed and minimized method is looked into. We used SIEMENS 1.5T and 3.0T MRI for experiment equipment. First, it places within the Phantom making a metalization(Ti+Al, Stainless, Nitinol) on 1.5T, 3.0T MRI and the T1 weighted image for each Sequence is acquired. The distortion of an image and about adjacent portion change of the metal material were compared through the obtained image, we analyzed. In all metalizations, a distortion was generated and a distortion was few in particularly, and Titanium-Aluminium alloy. And the extent of a distortion was worse image in the Turbo spin Echo. The use of the Titanium-Aluminium alloy the inserted in an internal material of the metalization is recommend. and, equipment of 1.5T the patient inserting a metal in an internal is used in an inspection than equipment of 3.0T. Also, the sequence is suitable when it obtains the optimum T1 weighted image of an impersonate to use the Turbo spin Echo.

System Design for Real-Time Measuring of Power Quality and Harmonics Distortion using Digital Signal Processor (Digital Signal Processor를 이용한 실시간 전력 요소와 왜율 측정 시스템 설계)

  • kim, Geun-Jun;Kang, Bongsoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.7
    • /
    • pp.1283-1289
    • /
    • 2016
  • Electrical energy is the essential resource for modern society. Recently, the demand for power was significantly increased. Increase of power demand has lead to a decrease in the power quality. Power quality in modern society has been an important factor that can cause a major problem throughout the home and general industry. Therefore, we need a system for preventing the power quality problems. To avoid power issues, it is important that the measurement of the power quality and initial response. In this paper, we propose real-time power quality measurement system and harmonics monitoring system. We design the system using DM240001 board include dsPIC33FJ256GP710A of microchip. This system can adapt three-phase three-wire system. And optimized the algorithm, we can measure momentary changes of the power system. In addition, designed system can measure harmonics distortion like to VTHD, ITHD and ITDD for 31th harmonics.

No-Reference Image Quality Assessment Using Complex Characteristics of Shearlet Transform (쉬어렛 변환의 복소수 특성을 이용하는 무참조 영상 화질 평가)

  • Mahmoudpour, Saeed;Kim, Manbae
    • Journal of Broadcast Engineering
    • /
    • v.21 no.3
    • /
    • pp.380-390
    • /
    • 2016
  • The field of Image Quality Measure (IQM) is growing rapidly in recent years. In particular, there was a significant progress in No-Reference (NR) IQM methods. In this paper, a general-purpose NR IQM algorithm is proposed based on the statistical characteristics of natural images in shearlet domain. The method utilizes a set of distortion-sensitive features extracted from statistical properties of shearlet coefficients. A complex version of the shearlet transform is employed to take advantage of phase and amplitude features in quality estimation. Furthermore, since shearlet transform can analyze the images at multiple scales, the effect of distortion on across-scale dependencies of shearlet coefficients is explored for feature extraction. For quality prediction, the features are used to train image classification and quality prediction models using a Support Vector Machine (SVM). The experimental results show that the proposed NR IQM is highly correlated with human subjective assessment and outperforms several Full-Reference (FR) and state-of-art NR IQMs.

Study on dose and image quality by Added filter and Grid change when exam abdominal fluoroscopy (복부투시조영 검사 시 Added filter와 Grid 변화에 따른 선량 및 화질에 관한 연구)

  • Hong, Seon Sook;Kang, Kyeong Mi;Seong, Min Suk;Lee, Jong Woong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.47-56
    • /
    • 2012
  • Amount of radiation exposure by seeing through fluoroscopy examination while is many patient exposure administration and unprepared misgovernment be. In this study, abdominal fluoroscopy during the scan, the dose and image quality change according to the use of grid and added filter optimized by measuring the test condition is proposed. Uses seeing through fluoroscopy examination equipment of Image Intensifier of Easy Diagnost Eleva (Philips), under tube type and uses Human phantom and measures average area dose according to grid insertion existence and nonexistence and added filter kind change. Measure sum of 29 organ dose and effective dose through PCXMC imagination simulation program and image J program through noise, SNR, image distortion was measured. Resolution, sharpness, and analyzed using the MTF curves. Fluorography the grid to insert the filter thickness and thickening and increased the average area dose and organ doses and effective dose. In the case of spot examination, when inserted grid, average area dose and organ dose and effective dose increased. Filter thickens the average area dose decreased, but the organ doses and effective dose were increased when use 0.2mmCu+1mmAl filter, decreased slightly. Noise and SNR measurements without inserting the gird, if you do not use the added filter was the lowest and when measure the distortion, 0.1mmCu+1mmAl filter was no difference of image quality in case insert grid was judged that when did not use occasion added filter that do not use grid, difference of image quality does not exist. Did not show a big difference, according to the grid and uses of the added filter sharpness, and resolution. Patient dose increases with factors that reduce the quality of the image so reckless grid and the use of the added filter when abdominal fluoroscopy examination should be cautious in using.

  • PDF

An Objective Speech Quality Measure using Masking Effect under Digital Mobile Telephone Network Environment (디지털 이동통신망 환경 하에서 마스킹 효과를 이용한 객관적 음질 평가 척도)

  • 김광수;김민정;석수영;정호열;정현일
    • Journal of Korea Multimedia Society
    • /
    • v.5 no.4
    • /
    • pp.405-414
    • /
    • 2002
  • In this paper, we propose a new objective speech quality measure using noise masking threshold for speech quality assessment of mobile telephone network environments, and verify the effectiveness of the proposed method through the experiments. For such a purpose, well known objective speech quality measures such as BSD and PSQM are first evaluated for digital mobile telephone network environments. However, these conventional methods does not have good performance under mobile networks environments compared to literary results. To be mote effective objective speech quality measure under mobile telephone environments, the proposed method employs human psychoacoustic masking effect. The DMOS, instead of MOS, is used as a subjective speech quality measure for performance evaluation. The performance comparison are carried out with speech data collected from digital mobile telephone environments. As results, the proposed measure have and average 4% higher performance, in terms of correlation, than existing objective speech quality measures such as BSD and PSQM.

  • PDF

An Efficient Image Matching Scheme Based on Min-Max Similarity for Distorted Images (왜곡 영상을 위한 효과적인 최소-최대 유사도(Min-Max Similarity) 기반의 영상 정합 알고리즘)

  • Heo, Young-Jin;Jeong, Da-Mi;Kim, Byung-Gyu
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.12
    • /
    • pp.1404-1414
    • /
    • 2019
  • Educational books commonly use some copyrighted images with various kinds of deformation for helping students understanding. When using several copyrighted images made by merging or editing distortion in legal, we need to pay a charge to original copyright holders for each image. In this paper, we propose an efficient matching algorithm by separating each copyrighted image with the merged and edited type including rotation, illumination change, and change of size. We use the Oriented FAST and Rotated BRIEF (ORB) method as a basic feature matching scheme. To improve the matching accuracy, we design a new MIN-MAX similarity in matching stage. With the distorted dataset, the proposed method shows up-to 97% of precision in experiments. Also, we demonstrate that the proposed similarity measure also outperforms compared to other measure which is commonly used.

Turbomachinery Inlet Flow Measurement without the Effect of Instrumentation (입구 Instrumentation의 영향을 최소화하는 터보기계 성능측정방법)

  • Kang, Jeong-Seek;Ahn, Iee-Ki
    • Aerospace Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.8-12
    • /
    • 2009
  • It is absolutely necessary to measure the inlet pressure and temperature of a turbine or a compressor to evaluate the performance of it. And to measure the representative-averaged pressure and temperature of turbine inlet flow, rake is normally used. Rake has several elements for temperature and pressure and several rakes are installed at the inlet to average the radial and circumferential distribution of inlet flow. However the rakes cause unexpected losses and flow distortion at the turbine inlet which make the measured rake data different from true inlet value. So the evaluation of a turbine or a compressor performance becomes not accurate. This study suggest a correlation method which measure the loss by inlet rake and incorporates it in evaluating the performance of turbomachinery.

  • PDF

The Study of Standard Deviation of Gray Scale Histogram in Digital Subtraction Radiography as a Test Parameter for SuperimpoSition Error (중첩 불일치 평가기준으로서의 계수공제영상의 계조도 표준편차 연구)

  • Cho Bong-Hae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.2
    • /
    • pp.417-422
    • /
    • 1999
  • Purpose : The aim of this study was to assess the validity of standard deviation of gray scale histogram in digital subtraction radiography as a test parameter for superimposition error. Materials and Methods : Twenty periapical radiographs were used as baseline images and they were copied to exclude the influence of exposure geomety and contrast differences. These subsequent images were linearly displaced by 0.1-0.5 mm in the x-. y- and xy-directions, rotated by 0.5-3° and distorted by angular contraction of 1-5° in x- and y-axis before subtraction. The standard deviations of gray levels in the subtraction images were obtained and paired t-tests were performed. Pearson correlation coefficients(r) were calculated between the standard deviations and the superimposition errors. Results : Linear displacement showed high correlation coefficients of 0.997, 0.997 and 0.995 in x-. y- and xy-axis respectively. Statistically significant different standard deviation existed among all linearly displaced groups(p<0.05). Distortion showed relatively low correlation coefficients of 0.982 and 0.959 in x- and y-axis. The standard deviations between the two distortion groups were statistically significant different(p<0.05). Conclusion : Standard deviation of gray level distribution in digital subtraction images is satisfactory but not perfect similarity measure to assess the superimposition errors.

  • PDF